1
|
Marbacher S, Kienzler JC, Mendelowitsch I, D'Alonzo D, Andereggen L, Diepers M, Remonda L, Fandino J. Comparison of Intra- and Postoperative 3-Dimensional Digital Subtraction Angiography in Evaluation of the Surgical Result After Intracranial Aneurysm Treatment. Neurosurgery 2021; 87:689-696. [PMID: 31748795 DOI: 10.1093/neuros/nyz487] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Accepted: 08/20/2019] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Postoperative three-dimensional digital subtraction angiography (3D-DSA) is the gold standard in evaluating intracranial aneurysm (IA) remnants after clipping. Should intraoperative 3D-DSA image quality be equally good as postoperative 3D-DSA, it could supplant the latter as standard of care for follow-up of clipped IA. OBJECTIVE To directly compare the quality of assessment of clipped IA by intraoperative and postoperative 3D-DSA. METHODS From a prospective cohort of 221 consecutive patients who underwent craniotomy for IA treatment in a hybrid operating room, we retrospectively studied 26 patients who had both intraoperative and postoperative 3D-DSA imaging of their clipped aneurysm. Comparison of intraoperative and postoperative 3D-DSA images (blinded for review) included parameters that affected image quality and differences between the 2 periods. RESULTS In the 26 patients with 32 clipped IAs, the mean interval was 11 ± 7 mo between intraoperative and postoperative imaging 3D-DSA examinations. Reconstruction with multiple clips was used in 14 (44%) cases. Of 15 remnants, 9 (60%) were small (<2 mm). In comparing intraoperative and postoperative 3D-DSA, no discordance or discrepancy in assessment of the surgical result was noted for any clipped IA, and overall imaging quality was excellent for both modalities. Factors affecting minor differences in image quality were not identified. CONCLUSION Compared with postoperative 3D-DSA, intraoperative 3D-DSA images achieved equally high quality and effective, immediate interpretation of the surgical clipping result. With comparable imaging quality and no discordant findings, intraoperative 3D-DSA could replace postoperative 3D-DSA to become the standard of care in IA surgery.
Collapse
Affiliation(s)
- Serge Marbacher
- Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland
| | - Jenny C Kienzler
- Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland
| | | | - Donato D'Alonzo
- Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland
| | - Lukas Andereggen
- Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland
| | - Michael Diepers
- Division of Neuroradiology, Department of Radiology, Kantonsspital Aarau, Aarau, Switzerland
| | - Luca Remonda
- Division of Neuroradiology, Department of Radiology, Kantonsspital Aarau, Aarau, Switzerland
| | - Javier Fandino
- Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland
| |
Collapse
|
2
|
Ozaydin B, Dawkins DW, Armstrong SA, Aagaard-Kienitz B, Baskaya MK. Intraoperative application of a new-generation 3D IV-DSA technology in resection of a hemorrhagic cerebellar AVM. NEUROSURGICAL FOCUS: VIDEO 2021; 4:V10. [PMID: 36284616 PMCID: PMC9542237 DOI: 10.3171/2020.10.focvid2086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Accepted: 10/20/2020] [Indexed: 12/03/2022]
Abstract
Although intravenous digital subtraction angiography (IV-DSA), cone-beam CT, and rotational angiography are well-established technologies, using them in a single system in the hybrid operating room to acquire high-quality noninvasive 3D images is a recent development. This video demonstrates microsurgical excision of a ruptured cerebellar arteriovenous malformation (AVM) in a 66-year-old male followed by intraoperative IV-DSA acquisition using a new-generation system (Artis Icono). IV-DSA confirmed in real time that no residual remained following excision without the need to reposition the patient. To the best of the authors’ knowledge, this is the first surgical video to demonstrate the simplified workflow and application of this technology in neurovascular surgery. The video can be found here: https://youtu.be/bo5ya9DQQPw
Collapse
Affiliation(s)
| | | | | | - Beverly Aagaard-Kienitz
- Departments of Neurological Surgery and
- Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | | |
Collapse
|
3
|
Marbacher S, Mendelowitsch I, Grüter BE, Diepers M, Remonda L, Fandino J. Comparison of 3D intraoperative digital subtraction angiography and intraoperative indocyanine green video angiography during intracranial aneurysm surgery. J Neurosurg 2019; 131:64-71. [PMID: 30004279 DOI: 10.3171/2018.1.jns172253] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2017] [Accepted: 01/16/2018] [Indexed: 11/06/2022]
Abstract
OBJECTIVE During the last decade, improvements in real-time, high-resolution imaging of surgically exposed cerebral vasculature have been realized with the successful introduction of intraoperative indocyanine green video angiography (ICGVA) and technical advances in intraoperative digital subtraction angiography (DSA). With the availability of 3D intraoperative DSA (3D-iDSA) in hybrid operating rooms, the present study offers a contemporary comparison for rates of accuracy and discordance. METHODS In this retrospective study of prospectively collected data, 140 consecutive patients underwent microsurgical treatment of intracranial aneurysms (IAs) in a hybrid operating room. Variables analyzed included patient demographics, aneurysm-specific characteristics, intraoperative ICGVA and 3D-iDSA findings, and the need for intraoperative clip readjustment. The authors defined the discordance rate of the two modalities as a false-negative finding that necessitated clip repositioning after 3D-iDSA. RESULTS In 120 patients, ICGVA and 3D-iDSA were used to evaluate 134 IA obliterations. Of 215 clips used, 29 (14%) were repositioned intraoperatively, improving the surgical result in all 29 patients (24%). Repositioning was prompted by visual inspection and microvascular Doppler ultrasonography in 8 (28%), ICGVA in 13 (45%), and 3D-iDSA in 7 (24%) patients. Clip repositioning was needed in 7 patients (6%) based on 3D-iDSA, yielding an ICGVA accuracy rate of 94%. Five (71%) of the ICGVA-3D-iDSA discordances that prompted clip repositioning occurred at the anterior communicating artery complex. CONCLUSIONS A combination of vascular monitoring techniques most often achieved correct intraoperative interpretation of complete IA occlusion and parent artery integrity. Compared with 3D-iDSA imaging, ICGVA demonstrated high accuracy. Despite the relatively low discordance rate, iDSA was confirmed to be the gold standard. Improved imaging quality, including 3D-iDSA, supports its routine use in IA surgery, obviating the need for postoperative DSA.
Collapse
Affiliation(s)
| | | | | | - Michael Diepers
- 2Division of Neuroradiology, Department of Radiology, Kantonsspital Aarau, Switzerland
| | - Luca Remonda
- 2Division of Neuroradiology, Department of Radiology, Kantonsspital Aarau, Switzerland
| | | |
Collapse
|
4
|
Kotowski M, Farzin B, Fahed R, Guilbert F, Chagnon M, Darsaut TE, Daniel RT, Raymond J. Residual Cerebral Aneurysms After Microsurgical Clipping: A New Scale, an Agreement Study, and a Systematic Review of the Literature. World Neurosurg 2018; 121:e302-e321. [PMID: 30261387 DOI: 10.1016/j.wneu.2018.09.100] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 09/10/2018] [Accepted: 09/12/2018] [Indexed: 12/16/2022]
Abstract
OBJECTIVE The surgical repair of a cerebral aneurysm does not always lead to complete occlusion. A standardized repeatable method of reporting results of surgical clipping is desirable. Our purpose was to systematically review methods of classifying aneurysm remnants, provide a new scale with precise definitions of categories, and perform an agreement study to assess the variability in adjudicating remnants after aneurysm clipping. METHODS A systematic review was performed to identify ways to report angiographic results of surgical clipping between 1963 and 2017. Postclipping angiographic results of 43 patients were also independently evaluated by 10 raters of various experience and backgrounds using a new 4-category scale. Agreement between responses were analyzed using κ statistics. RESULTS The systematic review yielded 63 articles with 37 different nomenclatures using 2-6 categories. The reliability of judging the presence of an aneurysm remnant on catheter angiography was studied only twice, with only 2 raters each time, with contradictory results. Interobserver agreement using the new 4-category scale was moderate (κ = 0.52; 95% confidence interval, 0.43-0.62) for all observers, but improved to substantial (κ = 0.62; 95% confidence interval, 0.47-0.76) when results were dichotomized (grade 0/1 vs. 2/3). CONCLUSIONS Various classification schemes to evaluate angiographic results after surgical clipping exist in the literature, but they lack standardization. Adjudication using fewer, better defined categories may yield more reliable agreement.
Collapse
Affiliation(s)
- Marc Kotowski
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada; Faculty of Biology and Medicine, Université de Lausanne, Lausanne, Switzerland
| | - Behzad Farzin
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada
| | - Robert Fahed
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada; Interventional Neuroradiology Unit, Fondati Rothschild Hospital, Paris, France
| | - François Guilbert
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada
| | - Miguel Chagnon
- Department of Mathematics and Statistics, Université de Montréal, Montreal, Quebec, Canada
| | - Tim E Darsaut
- University of Alberta Hospital, Mackenzie Health Sciences Centre, Division of Neurosurgery, Department of Surgery, Edmonton, Canada
| | - Roy T Daniel
- Faculty of Biology and Medicine, Université de Lausanne, Lausanne, Switzerland; Department of Clinical Neurosciences, Neurosurgery Unit, Centre hospitalier universitaire vaudois (CHUV), Lausanne, Switzerland
| | - Jean Raymond
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada.
| |
Collapse
|
5
|
The application of the unruptured intracranial aneurysm treatment score: a retrospective, single-center study. Neurosurg Rev 2018; 41:1021-1028. [DOI: 10.1007/s10143-018-0944-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Revised: 12/29/2017] [Accepted: 01/04/2018] [Indexed: 01/11/2023]
|
6
|
Yamaguchi S, Takemoto K, Takeda M, Kajihara Y, Mitsuhara T, Kolakshyapati M, Mukada K, Kurisu K. The Position and Role of Four-Dimensional Computed Tomography Angiography in the Diagnosis and Treatment of Spinal Arteriovenous Fistulas. World Neurosurg 2017; 103:611-619. [DOI: 10.1016/j.wneu.2017.03.100] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 03/20/2017] [Accepted: 03/21/2017] [Indexed: 11/24/2022]
|
7
|
Ott S, Gölitz P, Adamek E, Royalty K, Doerfler A, Struffert T. Flat-detector computed tomography evaluation in an experimental animal aneurysm model after endovascular treatment: A pilot study. Interv Neuroradiol 2015; 21:490-8. [PMID: 26111985 DOI: 10.1177/1591019915590364] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
We compared flat-detector computed tomography angiography (FD-CTA) to multislice computed tomography (MS-CTA) and digital subtracted angiography (DSA) for the visualization of experimental aneurysms treated with stents, coils or a combination of both.In 20 rabbits, aneurysms were created using the rabbit elastase aneurysm model. Seven aneurysms were treated with coils, seven with coils and stents, and six with self-expandable stents alone. Imaging was performed by DSA, MS-CTA and FD-CTA immediately after treatment. Multiplanar reconstruction (MPR) was performed and two experienced reviewers compared aneurysm/coil package size, aneurysm occlusion, stent diameters and artifacts for each modality.In aneurysms treated with stents alone, the visualization of the aneurysms was identical in all three imaging modalities. Residual aneurysm perfusion was present in two cases and visible in DSA and FD-CTA but not in MS-CTA. The diameter of coil-packages was overestimated in MS-CT by 56% and only by 16% in FD-CTA compared to DSA (p < 0.05). The diameter of stents was identical for DSA and FD-CTA and was significantly overestimated in MS-CTA (p < 0.05). Beam/metal hardening artifacts impaired image quality more severely in MS-CTA compared to FD-CTA.MS-CTA is impaired by blooming and beam/metal hardening artifacts in the visualization of implanted devices. There was no significant difference between measurements made with noninvasive FD-CTA compared to gold standard of DSA after stenting and after coiling/stent-assisted coiling of aneurysms. FD-CTA may be considered as a non-invasive alternative to the gold standard 2D DSA in selected patients that require follow up imaging after stenting.
Collapse
Affiliation(s)
- Sabine Ott
- Department of Neuroradiology, University of Erlangen-Nuremberg, Germany
| | - Philipp Gölitz
- Department of Neuroradiology, University of Erlangen-Nuremberg, Germany
| | - Edyta Adamek
- Department of Neuroradiology, University of Erlangen-Nuremberg, Germany
| | - Kevin Royalty
- Department of Biomedical Engineering and School of Medicine and Public Health, University of Wisconsin, USA
| | - Arnd Doerfler
- Department of Neuroradiology, University of Erlangen-Nuremberg, Germany
| | - Tobias Struffert
- Department of Neuroradiology, University of Erlangen-Nuremberg, Germany
| |
Collapse
|
8
|
Gölitz P, Struffert T, Ganslandt O, Lang S, Knossalla F, Doerfler A. Contrast-enhanced angiographic computed tomography for detection of aneurysm remnants after clipping: a comparison with digital subtraction angiography in 112 clipped aneurysms. Neurosurgery 2015; 74:606-13; discussion 613-4. [PMID: 24584137 DOI: 10.1227/neu.0000000000000326] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND For preclusion of remnants after aneurysm clipping, a reliable, noninvasive imaging technique is desirable. OBJECTIVE To evaluate the reliability of optimized angiographic computed tomography with intravenous contrast agent injection (ivACT) in detecting remnants after aneurysmal clipping compared with digital subtraction angiography (DSA), the gold standard. METHODS We included 84 patients with 112 clipped cerebral aneurysms of the anterior circulation. For treatment, 116 clips of cobalt and 57 clips of titanium alloy were used. In each patient, we performed an ivACT with dual rotational acquisition and a DSA. Data from ivACT were postprocessed with a dual-volume technique with newly implemented reconstructions modes. Aneurysm remnants were measured, classified, and correlated with DSA by 2 raters. RESULTS In total, 12 remnants were revealed by DSA, meaning a prevalence of 11%. IvACT demonstrated a sensitivity of 75% to 92% and a specificity of 99% in detecting remnants up to a minimal size of 0.7 × 0.3 mm. Classification of remnants by ivACT was identical to that by DSA, and assessment of size showed a significant correlation with DSA (P < .001). No significant differences between cobalt and titanium alloy were revealed concerning artifacts. CONCLUSION Optimized ivACT with enhanced postprocessing demonstrated high sensitivity and specificity in detecting remnants after aneurysm clipping in the anterior circulation. Classification and assessment of remnant size and detection of relevant parent artery stenosis showed high accuracy of ivACT compared with DSA. Our results indicate that ivACT might become a noninvasive alternative to DSA for postsurgical control.
Collapse
Affiliation(s)
- Philipp Gölitz
- *Department of Neuroradiology, ‡Department of Neurosurgery, §Department of Neurology, University of Erlangen-Nuremberg, Erlangen, Germany
| | | | | | | | | | | |
Collapse
|
9
|
Intravenous flat-detector computed tomography angiography for symptomatic cerebral vasospasm following aneurysmal subarachnoid hemorrhage. ScientificWorldJournal 2014; 2014:315960. [PMID: 25383367 PMCID: PMC4212549 DOI: 10.1155/2014/315960] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2014] [Revised: 08/28/2014] [Accepted: 09/13/2014] [Indexed: 11/18/2022] Open
Abstract
The study evaluated the diagnostic accuracy of intravenous flat-detector computed tomography (IV FDCT) angiography in assessing hemodynamically significant cerebral vasospasm in patients with subarachnoid hemorrhage (SAH) with digital subtraction angiography (DSA) as the reference. DSA and IV FDCT were conducted concurrently in patients suspected of having symptomatic cerebral vasospasm postoperatively. The presence and severity of vasospasm were estimated according to location (proximal versus distal). Vasospasm >50% was defined as having hemodynamic significance. Vasospasms <30% were excluded from this analysis to avoid spectrum bias. Twenty-nine patients (311 vessel segments) were measured. The intra- and interobserver agreements were excellent for depicting vasospasm (k = 0.84 and 0.74, resp.). IV FDCT showed a sensitivity of 95.7%, specificity of 92.3%, positive predictive value of 93.6%, and negative predictive value of 94.7% for detecting vasospasm (>50%) with DSA as the reference. Bland-Altman plots revealed good agreement of assessing vasospasm between the two tests. The discrepancy of vasospasm severity was more noted in the distal location with high-severity. However, it was not statistically significant (Spearman's rank test; r = 0.15, P = 0.35). Therefore, IV FDCT could be a feasible noninvasive test to evaluate suspected significant vasospasm in SAH.
Collapse
|
10
|
Budai C, Cirillo L, Patruno F, Dall'olio M, Princiotta C, Leonardi M. Flat panel angiography images in the post-operative follow-up of surgically clipped intracranial aneurysms. Neuroradiol J 2014; 27:203-6. [PMID: 24750710 DOI: 10.15274/nrj-2014-10022] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Accepted: 02/01/2014] [Indexed: 11/12/2022] Open
Abstract
Cerebral aneurysms must be monitored for varying periods after surgical and/or endovascular treatment and the duration of follow-up will depend on the type of therapy and the immediate post-operative outcome. Surgical clipping for intracranial aneurysms is a valid treatment but the metal clips generate artefacts so that follow-up monitoring still relies on catheter angiography. This study reports our preliminary experience with volumetric angiography using a Philips Allura Xper FD biplane system in the post-operative monitoring of aneurysm residues or major vascular changes following the surgical clipping of intracranial aneurysms. Volumetric angiography yields not only volume-rendered (VR) images, but a volume CT can also be reconstructed at high spatial and contrast resolution from a single acquisition, significantly enhancing the technique's diagnostic power. Between August 2012 and April 2013, we studied 19 patients with a total of 26 aneurysms treated by surgical clipping alone or in combination with endovascular treatment. All patients underwent standard post-operative angiographic follow-up including a rotational volumetric acquisition. Follow-up monitoring disclosed eight aneurysm residues whose assessment was optimal after surgical clipping both in patients with one metal clip and in those with two or more clips. In addition, small residues (1.3 mm) could be monitored together with any change in the calibre or course of vessels located adjacent to the clips. In conclusion, flat panel volume CT is much more reliable than the old 3D acquisitions that yielded only VR images. This is particularly true in patients with small aneurysm residues or lesions with multiple metal clips.
Collapse
Affiliation(s)
- Caterina Budai
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy -
| | - Luigi Cirillo
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy - Department of Experimental, Diagnostic and Specialty Medicine (DIMES), University of Bologna; Bologna, Italy
| | - Francesco Patruno
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy
| | - Massimo Dall'olio
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy
| | - Ciro Princiotta
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy
| | - Marco Leonardi
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy - Department of Experimental, Diagnostic and Specialty Medicine (DIMES), University of Bologna; Bologna, Italy
| |
Collapse
|
11
|
Angiographic C-arm CT visualization of the Woven EndoBridge Cerebral Aneurysm Embolization Device (WEB): First Experience in an Animal Aneurysm Model. Clin Neuroradiol 2013; 24:43-9. [PMID: 23712863 DOI: 10.1007/s00062-013-0224-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Accepted: 04/30/2013] [Indexed: 10/26/2022]
|
12
|
Impact of a new metal artefact reduction algorithm in the noninvasive follow-up of intracranial clips, coils, and stents with flat-panel angiographic CTA: initial results. Neuroradiology 2013; 55:813-8. [PMID: 23588613 DOI: 10.1007/s00234-013-1165-6] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2012] [Accepted: 03/01/2013] [Indexed: 10/27/2022]
Abstract
INTRODUCTION Flat-panel angiographic CT after intravenous contrast agent application (ivACT) is increasingly used as a follow-up examination after coiling, clipping, or stenting. The purpose of this study was to evaluate the feasibility of a new metal artefact reduction algorithm (MARA) in patients treated for intracranial aneurysms and stenosis. METHODS IvACT was performed on a flat-panel detector angiography system after intravenous application of 80 ml contrast media. The uncorrected raw images were transferred to a prototype reconstruction workstation where the MARA was applied. Two experienced neuroradiologists examined the corrected and uncorrected images on a commercially available workstation. RESULTS Artefacts around the implants were detected in all 16 uncorrected cases, while eight cases showed remaining artefacts after correction with the MARA. In the cases without correction, there were 11 cases with "extensive" artefacts and five cases with "many" artefacts. After correction, seven cases showed "few" and only one case "many" artefacts (Wilcoxon test, P < 0.001). Parent vessels were characterized as "not identifiable" in 62% of uncorrected images, while the delineation of parent vessels were classified as "excellent" in 50% of the cases after correction (Wilcoxon test, P = 0.001). CONCLUSIONS Use of the MARA in our study significantly reduced artefacts around metallic implants on ivACT images and allowed for the delineation of surrounding structures.
Collapse
|
13
|
Gölitz P, Struffert T, Ganslandt O, Saake M, Lücking H, Rösch J, Knossalla F, Doerfler A. Optimized angiographic computed tomography with intravenous contrast injection: an alternative to conventional angiography in the follow-up of clipped aneurysms? J Neurosurg 2012; 117:29-36. [PMID: 22519433 DOI: 10.3171/2012.3.jns111895] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
OBJECT The purpose of this study was to evaluate the diagnostic accuracy of an optimized angiographic CT (ACT) program with intravenous contrast agent injection (ivACT) in the assessment of potential aneurysm remnants after neurosurgical clipping compared with conventional digital subtraction angiography (DSA). METHODS The authors report on 14 patients with 19 surgically clipped cerebral aneurysms who were scheduled to undergo angiographic follow-up. For each patient, the authors performed ivACT with dual rotational acquisition and conventional angiography including a 3D rotational run. The ivACT and 3D DSA data were reconstructed with different imaging modes, including a newly implemented subtraction mode with motion correction. Thereafter, the data sets were merged by the dual-volume technique, and freely rotatable 3D images were obtained for further analysis. Observed aneurysm remnants were electronically measured and classified for each modality by 2 experienced neuroradiologists. RESULTS Digital subtraction angiography and ivACT both provided high-quality images without motion artifacts. Artifact disturbances from the aneurysm clips led to a compromised, but still sufficient, image quality in 1 case. The ivACT assessed all aneurysm remnants as true-positive up to a minimal size of 2.6×2.4 mm in accordance with the DSA findings. There was a tendency for ivACT to overestimate the size of the aneurysm remnants. All cases without aneurysm remnants on DSA were scored correctly as true-negative by ivACT. CONCLUSIONS By using an optimized image acquisition protocol as well as enhanced postprocessing algorithms, the noninvasive ivACT seems to achieve results comparable to those of conventional angiography in the follow-up of clipped cerebral aneurysms. The authors have shown that ivACT can provide reliable diagnostic information about potential aneurysm remnants after neurosurgical clipping with high sensitivity and specificity, sufficient for clinical decision making, at least for aneurysms in the anterior circulation located distal to the internal carotid artery. These preliminary results may be a promising step to replace conventional angiography by a noninvasive imaging technique in selected cases after aneurysm clipping.
Collapse
Affiliation(s)
- Philipp Gölitz
- Department of Neuroradiology, University of Erlangen-Nuremberg, Erlangen, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Pierot L, van der Bom IMJ, Wakhloo AK. Advances in stroke: advances in interventional neuroradiology. Stroke 2012; 43:310-3. [PMID: 22267828 DOI: 10.1161/strokeaha.111.642652] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Laurent Pierot
- Department of Neuroradiology, CHU Reims, Reims University, Reims, France
| | | | | |
Collapse
|