1
|
Vladev G, Sirakov A, Matanov S, Sirakova K, Ninov K, Sirakov S. Subacute Stent Deformities as an Underlying Reason for Vessel Stenosis after Flow Diversion with the p64 Stent: Review and Discussion of Biologic Mechanisms and Consequences. AJNR Am J Neuroradiol 2025; 46:712-719. [PMID: 40113252 DOI: 10.3174/ajnr.a8564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Accepted: 09/29/2024] [Indexed: 03/22/2025]
Abstract
BACKGROUND AND PURPOSE Flow-diverter stents are a potent and efficient tool in the instrumentarium of neurointerventional radiologists for the treatment of intracranial aneurysms. With their implementation, some adverse effects and complications such as hemorrhagic and ischemic ones, have been seen as a potential downfall of the method. In-stent stenosis is one such complication, which until now has not received enormous attention due to its seemingly benign characteristic. In our study we propose a different point of view on this matter and aim to establish a potential mechanism for its development: a subacute postprocedural stent deformation, due to segmental vessel constriction as a reaction to the implant. MATERIALS AND METHODS We enrolled 48 patients between the ages of 31 and 71 (8 men) with aneurysms on the distal portions of the ICA, all of whom were treated with the p64 flow-diverter stent, to assess the incidence of this phenomenon, as well as establish a correlation between it and subsequent clinical symptoms. A protocol for short-term follow-up, consisting only of a high-dose fluoroscopy image of the implant (conducted on the 14th postprocedural day) was implemented to assess the state of the implant before endothelization was to be expected. RESULTS Stent deformities were seen in 58% of cases. One patient with an observed stent deformity presented with several episodes of acute contralateral 1-sided weakness of the limbs. Seventy-one percent of those patients presented with a mild/moderate unilateral headache postprocedurally. A correlation between the deformity and a subsequent narrowing of the parent vessel diameter was established on follow-ups. Notable in-stent stenosis was reported in 35% of all cases. CONCLUSIONS Cases with subacute stent deformities are presented in a nonnegligible percent of flow-diversion therapies with the p64 stent. A statistically significant association between the observed deformation and subsequent in-stent stenosis was observed on follow-up.
Collapse
Affiliation(s)
- G Vladev
- From the Radiology Department (G.V., A.S., S.M., S.S.), UH St Ivan Rilski, Sofia, Bulgaria
- Radiology Department (K.S., G.V., A.S., S.S.), Medical University of Sofia, Bulgaria
| | - A Sirakov
- From the Radiology Department (G.V., A.S., S.M., S.S.), UH St Ivan Rilski, Sofia, Bulgaria
- Radiology Department (K.S., G.V., A.S., S.S.), Medical University of Sofia, Bulgaria
| | - S Matanov
- From the Radiology Department (G.V., A.S., S.M., S.S.), UH St Ivan Rilski, Sofia, Bulgaria
| | - K Sirakova
- Radiology Department (K.S., G.V., A.S., S.S.), Medical University of Sofia, Bulgaria
| | - K Ninov
- Neurosurgery Department (K.N.), UH St Ivan Rilski, Sofia, Bulgaria
| | - S Sirakov
- From the Radiology Department (G.V., A.S., S.M., S.S.), UH St Ivan Rilski, Sofia, Bulgaria
- Radiology Department (K.S., G.V., A.S., S.S.), Medical University of Sofia, Bulgaria
| |
Collapse
|
2
|
Liu Q, Lassila T, Lin F, MacRaild M, Patankar T, Islim F, Song S, Xu H, Chen X, Taylor ZA, Sarrami-Foroushani A, Frangi AF. Key influencers in an aneurysmal thrombosis model: A sensitivity analysis and validation study. APL Bioeng 2025; 9:016107. [PMID: 39959383 PMCID: PMC11826514 DOI: 10.1063/5.0223753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Accepted: 01/09/2025] [Indexed: 02/18/2025] Open
Abstract
Thrombosis is a biological response closely related to intracranial aneurysms, and the formation of thrombi inside the aneurysm is an important determinant of outcome after endovascular therapy. As the regulation of thrombosis is immensely complicated and the mechanisms governing thrombus formation are not fully understood, mathematical and computational modeling has been increasingly used to gain insight into thrombosis over the last 30 years. To have a robust computational thrombosis model for possible clinical use in the future, it is essential to assess the model's reliability through comprehensive sensitivity analysis of model parameters and validation studies based on clinical information of real patients. Here, we conduct a global sensitivity analysis on a previously developed thrombosis model, utilizing thrombus composition, the flow-induced platelet index, and the bound platelet concentration as output metrics. These metrics are selected for their relevance to thrombus stability. The flow-induced platelet index quantifies the effect of blood flow on the transport of platelets to and from the site of thrombus formation and thus on the final platelet content of the formed thrombus. The sensitivity analysis of the thrombus composition indicates that the concentration of resting platelets most influences the final thrombus composition. Then, for the first time, we validate the thrombosis model based on a real patient case using patient-specific resting platelet concentration and two previously calibrated trigger thresholds for thrombosis initiation. We show that our thrombosis model is capable of predicting thrombus formation both before and after endovascular treatment.
Collapse
Affiliation(s)
- Qiongyao Liu
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, United Kingdom
| | - Toni Lassila
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, United Kingdom
| | - Fengming Lin
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, United Kingdom
| | | | | | - Fathallah Islim
- Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | - Shuang Song
- School of Computer and Communication Engineering, University of Science and Technology Beijing, Beijing, China
| | - Huanming Xu
- School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Xiang Chen
- College of Electrical and Information Engineering, Hunan University, Changsha, China
| | - Zeike A. Taylor
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | | | | |
Collapse
|
3
|
Shiravand A, Richter K, Willmann P, Eulzer P, Lawonn K, Hundertmark A, Cattaneo G. Fabrication, characterization and numerical validation of a novel thin-wall hydrogel vessel model for cardiovascular research based on a patient-specific stenotic carotid artery bifurcation. Sci Rep 2024; 14:16301. [PMID: 39009618 PMCID: PMC11251049 DOI: 10.1038/s41598-024-66777-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 07/03/2024] [Indexed: 07/17/2024] Open
Abstract
In vitro vascular models, primarily made of silicone, have been utilized for decades for studying hemodynamics and supporting the development of implants for catheter-based treatments of diseases such as stenoses and aneurysms. Hydrogels have emerged as prominent materials in tissue-engineering applications, offering distinct advantages over silicone models for fabricating vascular models owing to their viscoelasticity, low friction, and tunable mechanical properties. Our study evaluated the feasibility of fabricating thin-wall, anatomical vessel models made of polyvinyl alcohol hydrogel (PVA-H) based on a patient-specific carotid artery bifurcation using a combination of 3D printing and molding technologies. The model's geometry, elastic modulus, volumetric compliance, and diameter distensibility were characterized experimentally and numerically simulated. Moreover, a comparison with silicone models with the same anatomy was performed. A PVA-H vessel model was integrated into a mock circulatory loop for a preliminary ultrasound-based assessment of fluid dynamics. The vascular model's geometry was successfully replicated, and the elastic moduli amounted to 0.31 ± 0.007 MPa and 0.29 ± 0.007 MPa for PVA-H and silicone, respectively. Both materials exhibited nearly identical volumetric compliance (0.346 and 0.342% mmHg-1), which was higher compared to numerical simulation (0.248 and 0.290% mmHg-1). The diameter distensibility ranged from 0.09 to 0.20% mmHg-1 in the experiments and between 0.10 and 0.18% mmHg-1 in the numerical model at different positions along the vessel model, highlighting the influence of vessel geometry on local deformation. In conclusion, our study presents a method and provides insights into the manufacturing and mechanical characterization of hydrogel-based thin-wall vessel models, potentially allowing for a combination of fluid dynamics and tissue engineering studies in future cardio- and neurovascular research.
Collapse
Affiliation(s)
- Ashkan Shiravand
- Institute of Biomedical Engineering, University of Stuttgart, Stuttgart, Germany.
| | - Kevin Richter
- Faculty of Natural and Environmental Sciences, University of Kaiserslautern-Landau, Landau, Germany
| | - Pia Willmann
- Institute of Biomedical Engineering, University of Stuttgart, Stuttgart, Germany
| | - Pepe Eulzer
- Faculty of Mathematics and Computer Science, University of Jena, Jena, Germany
| | - Kai Lawonn
- Faculty of Mathematics and Computer Science, University of Jena, Jena, Germany
| | - Anna Hundertmark
- Faculty of Natural and Environmental Sciences, University of Kaiserslautern-Landau, Landau, Germany
| | - Giorgio Cattaneo
- Institute of Biomedical Engineering, University of Stuttgart, Stuttgart, Germany
| |
Collapse
|
4
|
Ngwenya T, Grundlingh D, Ngoepe MN. Influence of vortical structures on fibrin clot formation in cerebral aneurysms: A two-dimensional computational study. J Biomech 2024; 165:111994. [PMID: 38394954 DOI: 10.1016/j.jbiomech.2024.111994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 02/09/2024] [Accepted: 02/12/2024] [Indexed: 02/25/2024]
Abstract
Thrombosis is an important contributor to cerebral aneurysm growth and progression. A number of sophisticated multiscale and multiphase in silico models have been developed with a view towards interventional planning. Many of these models are able to account for clotting outcomes, but do not provide detailed insight into the role of flow during clot development. In this study, we present idealised, two-dimensional in silico cerebral fibrin clot model based on computational fluid dynamics (CFD), biochemical modelling and variable porosity, permeability, and diffusivity. The model captures fibrin clot growth in cerebral aneurysms over a period at least 1000 s in five different geometries. The fibrin clot growth results were compared to an experiment presented in literature. The biochemistry was found to be more sensitive to mesh size compared to the haemodynamics, while larger timesteps overpredicted clot size in pulsatile flow. When variable diffusivity was used, the predicted clot size was 25.4% lesser than that with constant diffusivity. The predicted clot size in pulsatile flow was 14.6% greater than in plug flow. Different vortex modes were observed in plug and pulsatile flow; the latter presented smaller intermediate modes where the main vortex was smaller and less likely to disrupt the growing fibrin clot. Furthermore, smaller vortex modes were seen to support fibrin clot propagation across geometries. The model clearly demonstrates how the growing fibrin clot alters vortical structures within the aneurysm sac and how this changing flow, in turn, shapes the growing fibrin clot.
Collapse
Affiliation(s)
- Tinashe Ngwenya
- Centre for Research in Computational and Applied Mechanics (CERECAM), University of Cape Town, South Africa; Department of Mechanical Engineering, University of Cape Town, South Africa
| | - Divan Grundlingh
- Department of Mechanical Engineering, University of Cape Town, South Africa
| | - Malebogo N Ngoepe
- Centre for Research in Computational and Applied Mechanics (CERECAM), University of Cape Town, South Africa; Department of Mechanical Engineering, University of Cape Town, South Africa.
| |
Collapse
|
5
|
Suzuki Y, Toma N, Inoue K, Ichikawa T, Nishikawa H, Miura Y, Fujimoto M, Yasuda R, Maeda M, Suzuki H. Evaluation of Intra-Aneurysmal Residual Blood Flow with the iMSDE T1-Black Blood Imaging after Flow Diverter Treatment. JOURNAL OF NEUROENDOVASCULAR THERAPY 2023; 17:159-166. [PMID: 37609573 PMCID: PMC10442175 DOI: 10.5797/jnet.oa.2023-0016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 05/25/2023] [Indexed: 08/24/2023]
Abstract
Objective We aimed to evaluate the efficacy of the "improved motion-sensitized driven-equilibrium (iMSDE)"-prepared T1-weighted black blood (T1-BB) MRI for monitoring treatment effect with a flow diverter (FD) for cerebral aneurysms. Methods Following the exclusion of concomitant coiling and retreatment cases from 60 consecutive cases of cerebral aneurysms treated with FDs at our institution, 32 with imaging data were included in the analysis. Detectability of residual blood flow within the aneurysms was validated as follows: 1) comparison of MRI sequences (iMSDE-prepared T1-BB images, T1-weighted images [ T1WI], and time-of-flight [ TOF]-MRA) in cases of incompletely occluded aneurysms and 2) comparison of angiography and MRI sequences in the same period. Results 1) The probability of diagnosing intra-aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB (iMSDE-prepared T1-BB vs. T1WI, p <0.001; iMSDE-prepared T1-BB vs. TOF-MRA, p <0.001). 2) The diagnostic accuracy of residual aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB than that with T1WI (p = 0.032). Furthermore, in cases of incomplete occlusion, the probability of detecting intra-aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB (iMSDE-prepared T1-BB vs. T1WI, p <0.001; iMSDE-prepared T1-BB vs. TOF-MRA, p = 0.023). Conclusion Our results demonstrated that iMSDE-prepared T1-BB could help distinguish between blood flow and thrombus within the aneurysms after FD treatment, especially in the early stages of FD treatment.
Collapse
Affiliation(s)
- Yume Suzuki
- Department of Neurosurgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Naoki Toma
- Department of Neurosurgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Katsuhiro Inoue
- Department of Radiology, Mie University Hospital, Tsu, Mie, Japan
| | - Tomonori Ichikawa
- Department of Neurosurgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Hirofumi Nishikawa
- Department of Neurosurgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Yoichi Miura
- Department of Neurosurgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Masashi Fujimoto
- Department of Neurosurgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Ryuta Yasuda
- Department of Neurosurgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Masayuki Maeda
- Department of Neuroradiology, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Hidenori Suzuki
- Department of Neurosurgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| |
Collapse
|
6
|
Mezali F, Naima K, Benmamar S, Liazid A. Study and modeling of the thrombosis of small cerebral aneurysms, with and without flow diverter, by the lattice Boltzmann method. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 233:107456. [PMID: 36924532 DOI: 10.1016/j.cmpb.2023.107456] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Revised: 02/28/2023] [Accepted: 03/01/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND AND OBJECTIVE Small cerebral aneurysms are currently commonly treated non-invasively by flow diverter device. These stents lead to thrombotic occlusion of the aneurysm soon after their placement. The purpose of this work is to model clotting into intracranial aneurysms with and without stents, using a non-Newtonian of blood behavior, and to investigate the importance of stent to generate desired thrombus in intracranial aneurysms. METHOD The description of blood flow is made by the Boltzmann lattice equations, while thrombosis is modeled by the "fluid age" model. The lattice Boltzmann method is a computational technique for simulating fluid dynamics. The method is based on a mesoscopic approach, where the fluid is represented by a set of particles that move and interact on a grid. The model for blood coagulation is described by lattice Boltzmann Method, and it doesn't take into account the complicated coagulation pathway, this main idea is developed using the model of residence time of blood: all fluid in the domain is assumed to be capable of clotting, given enough time. The fluid age is measured by a passive scalar using a transport equation, and the node coagulates if the fluid age increases enough. Three small aneurysms of different sizes and shapes with three stents of various porosities were used to test the ability of the model to predict thrombosis. The "occlusion rate" parameter is used to assess the effectiveness of the flow diverter device. RESULTS For the large aspect ratio factor, the occlusion is: 91% for flow diverter devise with seven struts. For medium aspect ratio, a rate of 80% is achieved. An occlusion rate of slightly more than 30% is obtained for very small aneurysms with low aspect ratio. The Newtonian model underestimates the volume of thrombosis generated. The difference in the prediction of the thrombosis volume between the Newtonian and no-Newtonian Carreau-Yasuda models is approximately 10%. CONCLUSION The occlusion rate is proportional to the aspect ratio form factor. For the large and medium aspect ratio factors, the occlusion is satisfactory. Concerning very small aneurysms with low aspect ratio, aneurysm occlusion is low. This rate can be improved to almost complete occlusion if the flow diverter device is doubled. The generality of the model suggests its extensibility toward any other type of thrombosis (stenosis, thrombosis in aortic aneurysms).
Collapse
Affiliation(s)
- Farouk Mezali
- Water Sciences Research laboratory: LRS-Eau, National Polytechnic School, El Harrach, Algiers; Hydraulics department, Faculty of Technology, BP 166, M'sila 28000, Algeria
| | - Khatir Naima
- Department of Technology, University Centre of Naama (Ctr Univ Naama), P.O. Box 66, Naama 45000, Algeria.
| | - Saida Benmamar
- Water Sciences Research laboratory: LRS-Eau, National Polytechnic School, El Harrach, Algiers
| | - Abdelkrim Liazid
- Departement of physics, Faculty of Technology Faculty, Abou Bekr Belkaid University, 22 Rue Abi Ayed Abdelkrim, Tlemcen 13000, Algeria
| |
Collapse
|
7
|
Effect of Pulsatility on the Transport of Thrombin in an Idealized Cerebral Aneurysm Geometry. Symmetry (Basel) 2022. [DOI: 10.3390/sym14010133] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Computational models of cerebral aneurysm thrombosis are designed for use in research and clinical applications. A steady flow assumption is applied in many of these models. To explore the accuracy of this assumption a pulsatile-flow thrombin-transport computational fluid dynamics (CFD) model, which uses a symmetrical idealized aneurysm geometry, was developed. First, a steady-flow computational model was developed and validated using data from an in vitro experiment, based on particle image velocimetry (PIV). The experimental data revealed an asymmetric flow pattern in the aneurysm. The validated computational model was subsequently altered to incorporate pulsatility, by applying a data-derived flow function at the inlet boundary. For both the steady and pulsatile computational models, a scalar function simulating thrombin generation was applied at the aneurysm wall. To determine the influence of pulsatility on thrombin transport, the outputs of the steady model were compared to the outputs of the pulsatile model. The comparison revealed that in the pulsatile case, an average of 10.2% less thrombin accumulates within the aneurysm than the steady case for any given time, due to periodic losses of a significant amount of thrombin-concentrated blood from the aneurysm into the parent vessel’s bloodstream. These findings demonstrate that pulsatility may change clotting outcomes in cerebral aneurysms.
Collapse
|
8
|
Ngoepe MN, Pretorius E, Tshimanga IJ, Shaikh Z, Ventikos Y, Ho WH. Thrombin-Fibrinogen In Vitro Flow Model of Thrombus Growth in Cerebral Aneurysms. TH OPEN 2021; 5:e155-e162. [PMID: 34007954 PMCID: PMC8116173 DOI: 10.1055/s-0041-1728790] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 02/01/2021] [Indexed: 12/16/2022] Open
Abstract
Cerebral aneurysms are balloon-like structures that develop on weakened areas of cerebral artery walls, with a significant risk of rupture. Thrombi formation is closely associated with cerebral aneurysms and has been observed both before and after intervention, leading to a wide variability of outcomes in patients with the condition. The attempt to manage the outcomes has led to the development of various computational models of cerebral aneurysm thrombosis. In the current study, we developed a simplified thrombin–fibrinogen flow system, based on commercially available purified human-derived plasma proteins, which enables thrombus growth and tracking in an idealized cerebral aneurysm geometry. A three-dimensional printed geometry of an idealized cerebral aneurysm and parent vessel configuration was developed. An unexpected outcome was that this phantom-based flow model allowed us to track clot growth over a period of time, by using optical imaging to record the progression of the growing clot into the flow field. Image processing techniques were subsequently used to extract important quantitative metrics from the imaging dataset, such as end point intracranial thrombus volume. The model clearly demonstrates that clot formation, in cerebral aneurysms, is a complex interplay between mechanics and biochemistry. This system is beneficial for verifying computational models of cerebral aneurysm thrombosis, particularly those focusing on initial angiographic occlusion outcomes, and will also assist manufacturers in optimizing interventional device designs.
Collapse
Affiliation(s)
- Malebogo N Ngoepe
- Department of Mechanical Engineering, University of Cape Town, Cape Town, South Africa.,Stellenbosch Institute for Advanced Study, Wallenberg Research Centre, Stellenbosch University, Stellenbosch, South Africa
| | - Etheresia Pretorius
- Department of Physiological Sciences, Stellenbosch University, Stellenbosch, South Africa
| | - Ilunga J Tshimanga
- Department of Mechanical Engineering, University of South Africa, Johannesburg, South Africa
| | - Zahra Shaikh
- Department of Mechanical Engineering, University of South Africa, Johannesburg, South Africa
| | - Yiannis Ventikos
- Department of Mechanical Engineering, University College London, London, United Kingdom
| | - Wei Hua Ho
- Department of Mechanical Engineering, University of South Africa, Johannesburg, South Africa.,School of Mechanical, Industrial and Aeronautical Engineering, University of the Witwatersrand, Johannesburg, South Africa
| |
Collapse
|
9
|
McCulloch A, Turcott A, Graham G, Frenklakh S, Cardinal KO. Endothelialized silicone aneurysm models for in vitro evaluation of flow diverters. J Neurointerv Surg 2020; 13:727-731. [PMID: 33106319 PMCID: PMC8292603 DOI: 10.1136/neurintsurg-2020-016859] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 10/06/2020] [Accepted: 10/06/2020] [Indexed: 01/11/2023]
Abstract
Objective The goal of this work was to endothelialize silicone aneurysm tubes for use as in vitro models for evaluating endothelial cell interactions with neurovascular devices. The first objective was to establish consistent and confluent endothelial cell linings and to evaluate the silicone vessels over time. The second objective was to use these silicone vessels for flow diverter implantation and assessment. Methods Silicone aneurysm tubes were coated with fibronectin and placed into individual bioreactor systems. Human umbilical vein endothelial cells were deposited within tubes to create silicone vessels, then cultivated on a peristaltic pump and harvested at 2, 5, 7, or 10 days to evaluate the endothelial cell lining. A subset of silicone aneurysm vessels was used for flow diverter implantation, and evaluated for cell coverage over device struts at 3 or 7 days after deployment. Results Silicone vessels maintained confluent, PECAM-1 (platelet endothelial cell adhesion molecule 1) positive endothelial cell linings over time. These vessels facilitated and withstood flow diverter implantation, with robust cell linings disclosed after device deployment. Additionally, the endothelial cells responded to implanted devices through coverage of the flow diverter struts with increased cell coverage over the aneurysm seen at 7 days after deployment as compared with 3 days. Conclusions Silicone aneurysm models can be endothelialized and successfully maintained in vitro over time. Furthermore, these silicone vessels can be used for flow diverter implantation and assessment.
Collapse
Affiliation(s)
- Alyssa McCulloch
- Biomedical Engineering Department, Cal Poly, San Luis Obispo, California, USA
| | - Ashley Turcott
- Biomedical Engineering Department, Cal Poly, San Luis Obispo, California, USA
| | - Gabriella Graham
- Biomedical Engineering Department, Cal Poly, San Luis Obispo, California, USA
| | - Sergey Frenklakh
- Research and Development, Stryker Neurovascular Intervention, Fremont, California, USA
| | | |
Collapse
|
10
|
Ding A, Braschkat A, Guber A, Cattaneo G. New Concept of Patient-specific Flow Diversion Treatment of Intracranial Aneurysms : Design Aspects and in vitro Fluid Dynamics. Clin Neuroradiol 2020; 31:671-679. [PMID: 32651611 DOI: 10.1007/s00062-020-00930-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 06/20/2020] [Indexed: 11/29/2022]
Abstract
PURPOSE Current flow diverter (FD) designs limit the possibilities to achieve ideal functional parameters for intra-aneurysmal flow alteration in the implanted state. In this work, we evaluate the technical feasibility of a new patient-specific FD concept and the impact on intra-aneurysmal flow reduction compared to standard FD. METHODS Based on a literature review, we defined functional requirements, followed by the design and manufacturing of two different prototypes, which we implanted in a patient-specific phantom model. Functional porosity distributions and contour parameters were evaluated in the implanted state and compared to standard FD. Subsequently, we carried out a series of particle image velocimetry (PIV) measurements, in order to assess the impact on intra-aneurysmal flow. RESULTS With both patient-specific prototypes, it was possible to achieve stronger intra-aneurysmal flow reductions in terms of maximum and mean velocity and vorticity than a standard FD; however, one design showed a strong sensitivity against malpositioning. Overall, fluid dynamics parameters correlated with geometrical aspects such as the porosity and its grade of homogeneity. Beyond that, we found influences by the FD contour projection within the aneurysm, especially connected to the formation of in-jets. CONCLUSION Our results show that there is a technically feasible concept, which enables a more specific adjustment of functional FD parameters and more effective intra-aneurysmal flow reduction. This could potentially lead to improvements in the efficacy of aneurysm occlusion in cases with challenging fluid dynamics.
Collapse
Affiliation(s)
- Andreas Ding
- Acandis GmbH, R&D, Pforzheim, Baden-Württemberg, Germany. .,, Weltzienstr. 24, 76135, Karlsruhe, Germany.
| | | | - Andreas Guber
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Karlsruhe, Baden-Württemberg, Germany
| | - Giorgio Cattaneo
- Institute of Biomedical Engineering, University of Stuttgart, Stuttgart, Baden-Württemberg, Germany
| |
Collapse
|
11
|
Chodzyǹski KJ, Uzureau P, Nuyens V, Rousseau A, Coussement G, Zouaoui Boudjeltia K. The impact of arterial flow complexity on flow diverter outcomes in aneurysms. Sci Rep 2020; 10:10337. [PMID: 32587308 PMCID: PMC7316819 DOI: 10.1038/s41598-020-67218-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Accepted: 05/28/2020] [Indexed: 12/03/2022] Open
Abstract
The flow diverter is becoming a standard device for treating cerebral aneurysms. The aim of this in vitro study was to evaluate the impact of flow complexity on the effectiveness of flow diverter stents in a cerebral aneurysm model. The flow pattern of a carotid artery was decomposed into harmonics to generate four flow patterns with different pulsatility indexes ranging from 0.72 to 1.44. The effect of flow diverters on the aneurysm was investigated by injecting red dye or erythrocytes as markers. The recorded images were postprocessed to evaluate the maximum filling of the aneurysm cavity and the washout time. There were significant differences in the cut-off flows between the markers, linked to the flow complexity. Increasing the pulsatility index altered the performance of the flow diverter. The red dye was more sensitive to changes in flow than the red blood cell markers. The flow cut-off depended on the diverter design and the diverter deployment step was crucial for reproducibility of the results. These results strongly suggest that flow complexity should be considered when selecting a flow diverter.
Collapse
Affiliation(s)
- Kamil Jerzy Chodzyǹski
- Laboratoire de Médecine Expérimentale (ULB222), CHU Charleroi, Université Libre de Bruxelles, 6110, Montigny le Tilleul, Belgium.
| | - Pierrick Uzureau
- Laboratoire de Médecine Expérimentale (ULB222), CHU Charleroi, Université Libre de Bruxelles, 6110, Montigny le Tilleul, Belgium
| | - Vincent Nuyens
- Laboratoire de Médecine Expérimentale (ULB222), CHU Charleroi, Université Libre de Bruxelles, 6110, Montigny le Tilleul, Belgium
| | - Alexandre Rousseau
- Laboratoire de Médecine Expérimentale (ULB222), CHU Charleroi, Université Libre de Bruxelles, 6110, Montigny le Tilleul, Belgium
| | | | - Karim Zouaoui Boudjeltia
- Laboratoire de Médecine Expérimentale (ULB222), CHU Charleroi, Université Libre de Bruxelles, 6110, Montigny le Tilleul, Belgium
| |
Collapse
|
12
|
Villadolid C, Puccini B, Dennis B, Gunnin T, Hedigan C, Cardinal KO. Custom tissue engineered aneurysm models with varying neck size and height for early stage in vitro testing of flow diverters. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2020; 31:34. [PMID: 32172490 PMCID: PMC7072062 DOI: 10.1007/s10856-020-06372-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 02/28/2020] [Indexed: 05/03/2023]
Abstract
Endovascular techniques for treating cerebral aneurysms are rapidly advancing and require testing to optimize device configurations. The purpose of this work was to customize tissue-engineered aneurysm "blood vessel mimics" (aBVMs) for early stage in vitro assessment of vascular cell responses to flow diverters and other devices. Aneurysm scaffolds with varying neck size and height were created through solid modeling, mold fabrication, mandrel creation, and electrospinning. Scaffold dimensions and fiber morphology were characterized. aBVMs were created by depositing human smooth muscle and endothelial cells within scaffolds, and cultivating within perfusion bioreactors. These vessels were left untreated or used for flow diverter implantation. Cellular responses to flow diverters were evaluated at 3 days. Custom scaffolds were created with aneurysm neck diameters of 2.3, 3.5, and 5.5 mm and with aneurysm heights of 2, 5, and 8 mm. A set of scaffolds with varying neck size was used for aBVM creation, and dual-sodding of endothelial and smooth muscle cells resulted in consistent and confluent cellular linings. Flow diverters were successfully implanted in a subset of aBVMs, and initial cell coverage over devices was seen in the parent vessel at 3 days. Direct visualization of the device over the neck region was feasible, supporting the future use of these models for evaluating and comparing flow diverter healing. Tissue-engineered aneurysm models can be created with custom neck sizes and heights, and used to evaluate cellular responses to flow diverters and other endovascular devices.
Collapse
Affiliation(s)
- Camille Villadolid
- Biomedical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
| | - Brandon Puccini
- Mechanical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
| | - Benjamin Dennis
- Biomedical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
| | - Tessa Gunnin
- Biomedical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
| | - Conor Hedigan
- Biomedical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
| | | |
Collapse
|
13
|
Ho WH, Tshimanga IJ, Ngoepe MN, Jermy MC, Geoghegan PH. Evaluation of a Desktop 3D Printed Rigid Refractive-Indexed-Matched Flow Phantom for PIV Measurements on Cerebral Aneurysms. Cardiovasc Eng Technol 2019; 11:14-23. [PMID: 31820351 PMCID: PMC7002330 DOI: 10.1007/s13239-019-00444-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Accepted: 11/20/2019] [Indexed: 12/24/2022]
Abstract
PURPOSE Fabrication of a suitable flow model or phantom is critical to the study of biomedical fluid dynamics using optical flow visualization and measurement methods. The main difficulties arise from the optical properties of the model material, accuracy of the geometry and ease of fabrication. METHODS Conventionally an investment casting method has been used, but recently advancements in additive manufacturing techniques such as 3D printing have allowed the flow model to be printed directly with minimal post-processing steps. This study presents results of an investigation into the feasibility of fabrication of such models suitable for particle image velocimetry (PIV) using a common 3D printing Stereolithography process and photopolymer resin. RESULTS An idealised geometry of a cerebral aneurysm was printed to demonstrate its applicability for PIV experimentation. The material was shown to have a refractive index of 1.51, which can be refractive matched with a mixture of de-ionised water with ammonium thiocyanate (NH4SCN). The images were of a quality that after applying common PIV pre-processing techniques and a PIV cross-correlation algorithm, the results produced were consistent within the aneurysm when compared to previous studies. CONCLUSIONS This study presents an alternative low-cost option for 3D printing of a flow phantom suitable for flow visualization simulations. The use of 3D printed flow phantoms reduces the complexity, time and effort required compared to conventional investment casting methods by removing the necessity of a multi-part process required with investment casting techniques.
Collapse
Affiliation(s)
- W H Ho
- Department of Mechanical and Industrial Engineering, University of South Africa, Johannesburg, South Africa.,School of Mechanical Aerospace and Industrial Engineering, University of the Witwatersrand, Johannesburg, South Africa
| | - I J Tshimanga
- Department of Mechanical and Industrial Engineering, University of South Africa, Johannesburg, South Africa
| | - M N Ngoepe
- Department of Mechanical Engineering, University of Cape Town, Cape Town, South Africa
| | - M C Jermy
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - P H Geoghegan
- Department of Mechanical and Industrial Engineering, University of South Africa, Johannesburg, South Africa. .,Biomedical Engineering, School of Life and Health Sciences, Aston University, Birmingham, England.
| |
Collapse
|
14
|
Brina O, Bouillot P, Reymond P, Luthman AS, Santarosa C, Fahrat M, Lovblad KO, Machi P, Delattre BMA, Pereira VM, Vargas MI. How Flow Reduction Influences the Intracranial Aneurysm Occlusion: A Prospective 4D Phase-Contrast MRI Study. AJNR Am J Neuroradiol 2019; 40:2117-2123. [PMID: 31727755 PMCID: PMC6975363 DOI: 10.3174/ajnr.a6312] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Accepted: 09/20/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND AND PURPOSE Flow-diverter stents are widely used for the treatment of wide-neck intracranial aneurysms. Various parameters may influence intracranial aneurysm thrombosis, including the flow reduction induced by flow-diverter stent implantation, which is assumed to play a leading role. However, its actual impact remains unclear due to the lack of detailed intra-aneurysmal flow measurements. This study aimed to clarify this relationship by quantitatively measuring the intra-aneurysmal flow using 4D phase-contrast MR imaging. MATERIALS AND METHODS We acquired prospective pre- and post-stent implantation 4D phase-contrast MR imaging data of a consecutive series of 23 patients treated with flow-diverter stents. Velocity field data were combined with the intraprocedural 3D angiogram vessel geometries for precise intracranial aneurysm extraction and partial volume correction. Intra-aneurysmal hemodynamic modifications were compared with occlusion outcomes at 6 and 12 months. RESULTS The averaged velocities at systole were lower after flow-diverter stent implantation for all patients and ranged from 21.7 ± 7.1 cm/s before to 7.2 ± 2.9 cm/s after stent placement. The velocity reduction was more important for the group of patients with aneurysm thrombosis at 6 months (68.8%) and decreased gradually from 66.2% to 55% for 12-month thrombosis and no thrombosis, respectively (P = .08). CONCLUSIONS We propose an innovative approach to measure intracranial flow changes after flow-diverter stent implantation. We identified a trend between flow reduction and thrombosis outcome that brings a new insight into current understanding of the flow-diversion treatment response.
Collapse
Affiliation(s)
- O Brina
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - P Bouillot
- Department of Quantum Matter Physics (P.B.), University of Geneva, Geneva, Switzerland
| | - P Reymond
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - A S Luthman
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - C Santarosa
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - M Fahrat
- Laboratory for Hydraulic Machines (M.F.), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - K O Lovblad
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - P Machi
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - B M A Delattre
- Radiology (B.M.A.D.), Geneva University Hospitals, University of Geneva, Geneva, Switzerland
| | - V M Pereira
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
- Division of Neuroradiology (V.M.P.)
- Department of Medical Imaging (V.M.P.)
- Division of Neurosurgery (V.M.P.), Department of Surgery, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada
| | - M I Vargas
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| |
Collapse
|
15
|
Mühl-Benninghaus R, Abboud R, Ding A, Krajewski S, Simgen A, Tomori T, Bomberg H, Yilmaz U, Brochhausen C, Reith W, Cattaneo G. Preclinical Evaluation of the Accero Stent: Flow Remodelling Effect on Aneurysm, Vessel Reaction and Side Branch Patency. Cardiovasc Intervent Radiol 2019; 42:1786-1794. [DOI: 10.1007/s00270-019-02345-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Accepted: 09/19/2019] [Indexed: 10/25/2022]
|
16
|
Computational methods applied to analyze the hemodynamic effects of flow-diverter devices in the treatment of cerebral aneurysms: Current status and future directions. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2019. [DOI: 10.1016/j.medntd.2019.100018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
17
|
Thrombosis of Large Aneurysm Induced by Flow-Diverter Stent and Dissolved by Direct Factor Xa Inhibitor. World Neurosurg 2019; 131:209-212. [PMID: 31442658 DOI: 10.1016/j.wneu.2019.08.053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Revised: 08/08/2019] [Accepted: 08/09/2019] [Indexed: 12/25/2022]
Abstract
BACKGROUND Antiplatelet agents are typically administered before and after treatment using flow-diverter stents (FDS) to prevent thrombotic complications, but the effects of anticoagulants are unclear. We present a patient with a giant aneurysm treated with an FDS. The thrombus within the aneurysm was dissolved when a direct factor Xa inhibitor was administered to treat lower limb venous thrombosis that occurred secondary to steroid use. CASE DESCRIPTION A 60-year-old woman with a 30-mm giant thrombosed aneurysm in the cavernous segment of the right internal carotid artery presenting with headache and right abducens nerve palsy was treated by placing an FDS. Diplopia and increased pain in her right eye appeared on postoperative day 7, and both were alleviated by continuous oral administration of prednisolone. Angiography 3 months postoperatively revealed that the aneurysm thrombosis had progressed, and there were signs of healing. However, at the same time, lower limb venous thrombosis occurred, which was treated by continuous edoxaban. Six months after surgery, her headaches worsened and angiography showed that the aneurysm was again contrast enhanced and that the thrombus within the aneurysm had dissolved. After discontinuing edoxaban 9 months after surgery, the aneurysmal thrombosis had again rapidly progressed. CONCLUSIONS Administration of a direct factor Xa inhibitor during healing after placing an FDS may cause dissolution of an existing thrombus; therefore factor Xa inhibitors must be used with caution.
Collapse
|
18
|
Sarrami-Foroushani A, Lassila T, Hejazi SM, Nagaraja S, Bacon A, Frangi AF. A computational model for prediction of clot platelet content in flow-diverted intracranial aneurysms. J Biomech 2019; 91:7-13. [PMID: 31104921 DOI: 10.1016/j.jbiomech.2019.04.045] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Revised: 03/14/2019] [Accepted: 04/30/2019] [Indexed: 01/30/2023]
Abstract
Treatment of intracranial aneurysms with flow-diverting stents is a safe and minimally invasive technique. The goal is stable embolisation that facilitates stent endothelialisation, and elimination of the aneurysm. However, it is not fully understood why some aneurysms fail to develop a stable clot even with sufficient levels of flow reduction. Computational prediction of thrombus formation dynamics can help predict the post-operative response in such challenging cases. In this work, we propose a new model of thrombus formation and platelet dynamics inside intracranial aneurysms. Our novel contribution combines platelet activation and transport with fibrin generation, which is key to characterising stable and unstable thrombus. The model is based on two types of thrombus inside aneurysms: red thrombus (fibrin- and erythrocyte-rich) can be found in unstable clots, while white thrombus (fibrin- and platelet-rich) can be found in stable clots. The thrombus generation model is coupled to a CFD model and the flow-induced platelet index (FiPi) is defined as a quantitative measure of clot stability. Our model is validated against an in vitro phantom study of two flow-diverting stents with different sizing. We demonstrate that our model accurately predicts the lower thrombus stability in the oversized stent scenario. This opens possibilities for using computational simulations to improve endovascular treatment planning and reduce adverse events, such as delayed haemorrhage of flow-diverted aneurysms.
Collapse
Affiliation(s)
- Ali Sarrami-Foroushani
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK
| | - Toni Lassila
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK
| | - Seyed Mostafa Hejazi
- Department of Electronic and Electrical Engineering, The University of Sheffield, Sheffield, UK
| | | | - Andrew Bacon
- Department of Neurosurgery, Royal Hallamshire Hospital, Sheffield, UK
| | - Alejandro F Frangi
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK; Biomedical Imaging Department, Leeds Institute for Cardiovascular and Metabolic Medicine (LICAMM), School of Medicine, University of Leeds, Leeds, UK.
| |
Collapse
|
19
|
Reconstructing patient-specific cerebral aneurysm vasculature for in vitro investigations and treatment efficacy assessments. J Clin Neurosci 2018; 61:153-159. [PMID: 30470652 DOI: 10.1016/j.jocn.2018.10.103] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Accepted: 10/27/2018] [Indexed: 11/27/2022]
Abstract
Perianeurysmal hemodynamics play a vital role in the initiation, growth and rupture of intracranial aneurysms. In vitro investigations of aneurysmal hemodynamics are helpful to visualize and measure blood flow, and aiding surgical planning approaches. Improving in vitro model creation can improve the feasibility and accuracy of hemodynamic investigations and surgical planning, improving clinical value. In this study, in vitro models were created from three-dimensional rotational angiography (3DRA) of six patients harboring intracranial aneurysms using a multi-step process involving 3D printing, index of refraction matching and silicone casting that renders the models transparent for flow visualization. Each model was treated with the same commercially-available, patient-specific, endovascular devices (coils and/or stents). All models were scanned by synchrotron X-ray microtomography to obtain high-resolution imaging of the vessel lumen, aneurysmal sac and endovascular devices. Dimensional accuracy was compared by quantifying the differences between the microtomographic reconstructions of the fabricated phantoms and the original 3DRA obtained during patient treatment. True-scale in vitro flow phantoms were successfully created for all six patients. Optical transparency was verified by using an index of refraction matched working fluid that replicated the mechanical behavior of blood. Synchrotron imaging of vessel lumen, aneurysmal sac and endovascular devices was successfully obtained, and dimensional errors were found to be O(100 μm). The creation of dimensionally-accurate, optically-transparent flow phantoms of patient-specific intracranial aneurysms is feasible using 3D printing technology. Such models may enable in vitro investigations of aneurysmal hemodynamics to aid in treatment planning and outcome prediction to devise optimal patient-specific neurointerventional strategies.
Collapse
|
20
|
Roloff C, Stucht D, Beuing O, Berg P. Comparison of intracranial aneurysm flow quantification techniques: standard PIV vs stereoscopic PIV vs tomographic PIV vs phase-contrast MRI vs CFD. J Neurointerv Surg 2018; 11:275-282. [DOI: 10.1136/neurintsurg-2018-013921] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Revised: 06/22/2018] [Accepted: 06/29/2018] [Indexed: 12/21/2022]
Abstract
Image-based hemodynamic simulations to assess the rupture risk or improve the treatment planning of intracranial aneurysms have become popular recently. However, due to strong modeling assumptions and limitations, the acceptance of numerical approaches remains limited. Therefore, validation using experimental methods is mandatory.In this study, a unique compilation of four in-vitro flow measurements (three particle image velocimetry approaches using a standard (PIV), stereoscopic (sPIV), and tomographic (tPIV) setup, as well as a phase-contrast magnetic resonance imaging (PC-MRI) measurement) were compared with a computational fluid dynamics (CFD) simulation. This was carried out in a patient-specific silicone phantom model of an internal carotid artery aneurysm under steady flow conditions. To evaluate differences between each technique, a similarity index (SI) with respect to the velocity vectors and the average velocity magnitude differences among all involved modalities were computed.The qualitative comparison reveals that all techniques are able to provide a reasonable description of the global flow structures. High quantitative agreement in terms of SI and velocity magnitude differences was found between all PIV methods and CFD. However, quantitative differences were observed between PC-MRI and the other techniques. Deeper analysis revealed that the limited resolution of the PC-MRI technique is a major contributor to the experienced differences and leads to a systematic underestimation of overall velocity magnitude levels inside the vessel. This confirms the necessity of using highly resolving flow measurement techniques, such as PIV, in an in-vitro environment to individually verify the validity of the numerically obtained hemodynamic results.
Collapse
|
21
|
Ngoepe MN, Frangi AF, Byrne JV, Ventikos Y. Thrombosis in Cerebral Aneurysms and the Computational Modeling Thereof: A Review. Front Physiol 2018; 9:306. [PMID: 29670533 PMCID: PMC5893827 DOI: 10.3389/fphys.2018.00306] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Accepted: 03/13/2018] [Indexed: 01/26/2023] Open
Abstract
Thrombosis is a condition closely related to cerebral aneurysms and controlled thrombosis is the main purpose of endovascular embolization treatment. The mechanisms governing thrombus initiation and evolution in cerebral aneurysms have not been fully elucidated and this presents challenges for interventional planning. Significant effort has been directed towards developing computational methods aimed at streamlining the interventional planning process for unruptured cerebral aneurysm treatment. Included in these methods are computational models of thrombus development following endovascular device placement. The main challenge with developing computational models for thrombosis in disease cases is that there exists a wide body of literature that addresses various aspects of the clotting process, but it may not be obvious what information is of direct consequence for what modeling purpose (e.g., for understanding the effect of endovascular therapies). The aim of this review is to present the information so it will be of benefit to the community attempting to model cerebral aneurysm thrombosis for interventional planning purposes, in a simplified yet appropriate manner. The paper begins by explaining current understanding of physiological coagulation and highlights the documented distinctions between the physiological process and cerebral aneurysm thrombosis. Clinical observations of thrombosis following endovascular device placement are then presented. This is followed by a section detailing the demands placed on computational models developed for interventional planning. Finally, existing computational models of thrombosis are presented. This last section begins with description and discussion of physiological computational clotting models, as they are of immense value in understanding how to construct a general computational model of clotting. This is then followed by a review of computational models of clotting in cerebral aneurysms, specifically. Even though some progress has been made towards computational predictions of thrombosis following device placement in cerebral aneurysms, many gaps still remain. Answering the key questions will require the combined efforts of the clinical, experimental and computational communities.
Collapse
Affiliation(s)
- Malebogo N Ngoepe
- Department of Mechanical Engineering, University of Cape Town, Cape Town, South Africa.,Centre for High Performance Computing, Council for Scientific and Industrial Research, Cape Town, South Africa.,Stellenbosch Institute for Advanced Study, Wallenberg Research Centre at Stellenbosch University, Stellenbosch, South Africa
| | - Alejandro F Frangi
- Center for Computational Imaging and Simulation Technologies in Biomedicine, University of Sheffield, Sheffield, United Kingdom
| | - James V Byrne
- Department of Neuroradiology, John Radcliffe Hospital, Oxford, United Kingdom
| | - Yiannis Ventikos
- UCL Mechanical Engineering, University College London, London, United Kingdom
| |
Collapse
|
22
|
A Novel Plasma-Based Fluid for Particle Image Velocimetry (PIV): In-Vitro Feasibility Study of Flow Diverter Effects in Aneurysm Model. Ann Biomed Eng 2018; 46:841-848. [PMID: 29488139 DOI: 10.1007/s10439-018-2002-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Accepted: 02/22/2018] [Indexed: 10/17/2022]
|
23
|
In vitro, contrast agent-based evaluation of the influence of flow diverter size and position on intra-aneurysmal flow dynamics using syngo iFlow. Neuroradiology 2017; 59:1275-1283. [PMID: 28842742 DOI: 10.1007/s00234-017-1903-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Accepted: 08/09/2017] [Indexed: 10/19/2022]
|
24
|
Peach TW, Ventikos Y, Byrne JV, You Z. Porcine In Vivo Validation of a Virtual Contrast Model: The Influence of Contrast Agent Properties and Vessel Flow Rates. AJNR Am J Neuroradiol 2016; 37:2304-2309. [PMID: 27390316 DOI: 10.3174/ajnr.a4884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Accepted: 06/02/2016] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Accurately and efficiently modeling the transport of angiographic contrast currently offers the best method of verifying computational fluid dynamics simulations and, with it, progress toward the lofty goal of prediction of aneurysm treatment outcome a priori. This study specifically examines the influence of estimated flow rate and contrast properties on such in silico predictions of aneurysm contrast residence and decay. MATERIALS AND METHODS Four experimental sidewall aneurysms were created in swine, with aneurysm contrast flow patterns and decay rates observed under angiography. A simplified computational fluid dynamics model of the experimental aneurysm was constructed from 3D angiography and contrast residence predicted a priori. The relative influence of a number of estimated model parameters (contrast viscosity, contrast density, and blood flow rate) on contrast residence was then investigated with further simulations. RESULTS Contrast infiltration and washout pattern were accurately predicted by the a priori computational fluid dynamics model; however, the contrast decay rate was underestimated by ∼25%. This error was attributed to the estimated parent vessel flow rate alone, and the effects of contrast viscosity and density on the decay rate were found to be inconsequential. A linear correlation between the parent vessel flow rate and the corresponding contrast decay rate was observed. CONCLUSIONS In experimental sidewall aneurysms, contrast fluid properties (viscosity and density) were shown to have a negligible effect on variation in the modeled contrast decay rate. A strong linear correlation was observed between parent vessel flow rate and contrast decay over a physiologically reasonable range of flow rates.
Collapse
Affiliation(s)
- T W Peach
- From the Department of Mechanical Engineering (T.W.P., Y.V.), University College London, London, UK
| | - Y Ventikos
- From the Department of Mechanical Engineering (T.W.P., Y.V.), University College London, London, UK
| | - J V Byrne
- Department of Neuroradiology (J.V.B.), John Radcliffe Hospital, Oxford, UK
| | - Z You
- Department of Engineering Science (Z.Y.), University of Oxford, Oxford, UK
| |
Collapse
|
25
|
Peach T, Spranger K, Ventikos Y. Virtual flow-diverter treatment planning: The effect of device placement on bifurcation aneurysm haemodynamics. Proc Inst Mech Eng H 2016; 231:432-443. [PMID: 27780870 DOI: 10.1177/0954411916673674] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Bifurcation aneurysms account for a large fraction of cerebral aneurysms and often present morphologies that render traditional endovascular treatments, such as coiling, challenging and problematic. Flow-diverter stents offer a potentially elegant treatment option for such aneurysms, but clinical use of these devices remains controversial. Specifically, the deployment of a flow-diverter device in a bifurcation entails jailing one or more potentially vital vessels with a low-porosity mesh designed to restrict the flow. When multiple device placement configurations exist, the most appropriate clinical decision becomes increasingly opaque. In this study, three bifurcation aneurysm geometries were virtually treated by flow-diverter device. Each aneurysm was selected to offer two possible device deployment positions. Flow-diverters similar to commercially available designs were deployed with a fast-deployment algorithm before transient and steady state computational fluid dynamics simulations were performed. Reductions in aneurysm inflow, mean wall shear stress and maximum wall shear stress, all factors often linked with aneurysm treatment outcome, were compared for different device configurations in each aneurysm. In each of the three aneurysms modelled, a particular preferential device placement was shown to offer superior performance with the greatest reduction in the flow metrics considered. In all the three aneurysm geometries, substantial variations in inflow reduction (up to 25.3%), mean wall shear stress reduction (up to 14.6%) and maximum wall shear stress reduction (up to 12.1%) were seen, which were all attributed to device placement alone. Optimal device placement was found to be non-trivial and highly aneurysm specific; in only one-third of the simulated geometries, the best overall performance was achieved by deploying a device in the daughter vessel with the highest flow rate. Good correspondence was seen between transient results and steady state computations that offered a significant reduction in simulation run time. If accurate steady state computations are combined with the fast-deployment algorithm used, the modest run time and corresponding hardware make a virtual treatment pipeline in the clinical setting a meaningful possibility.
Collapse
Affiliation(s)
- Thomas Peach
- Department of Mechanical Engineering, University College London, London, UK
| | - Katerina Spranger
- Department of Mechanical Engineering, University College London, London, UK
| | - Yiannis Ventikos
- Department of Mechanical Engineering, University College London, London, UK
| |
Collapse
|