1
|
Demirci M, Tuncer S, Tekçe N, Baydemir C. The effect of different application modes of a 1-step self-etch adhesive on the clinical performance of Class I composite restorations: A randomized controlled clinical trial. J ESTHET RESTOR DENT 2022; 34:1039-1050. [PMID: 35604035 DOI: 10.1111/jerd.12933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 05/01/2022] [Accepted: 05/02/2022] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To evaluate the clinical performance of a 1-step self-etch dentin adhesive that was applied according to the manufacturers' recommendations, doubling the adhesive application time and layer in Class I cavities with a composite resin. MATERIALS AND METHODS A total of 39 patients aged between 14 and 43 (mean age: 19.1) years were enrolled in the study. Each patient received three restorations. In these three restorations, a 1-step self-etch adhesive was applied according to the manufacturer's recommendations (control group), by doubling the adhesive application time, and with double layers. The restorations were evaluated according to modified USPHS criteria at baseline, and 1, 2, 3, and 4-year recalls. RESULTS After 4 years, the success rate was 100% for restorations with the adhesive applied according to the manufacturers' recommendations, 96.9% for restorations applied by doubling the adhesive application time, and 93.8% for restorations applied with double adhesive layers. There was no significant difference between the three application methods among all the evaluation periods regarding the evaluation criteria. CONCLUSIONS The 4-year success rates of a 1-step self-etch dentin adhesive that was applied according to the manufacturers' recommendation, by doubling the adhesive application time, and with double layers were excellent. CLINICAL SIGNIFICANCE It is not recommended to double the adhesive application time nor apply a double layer of a 1-step self-etch adhesive because it does not improve the clinical performance of Class I composite restorations.
Collapse
Affiliation(s)
- Mustafa Demirci
- Department of Restorative Dentistry, Faculty of Dentistry, Istanbul University, Istanbul, Turkey
| | - Safa Tuncer
- Department of Restorative Dentistry, Faculty of Dentistry, Istanbul University, Istanbul, Turkey
| | - Neslihan Tekçe
- Department of Restorative Dentistry, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey
| | - Canan Baydemir
- Department of Biostatistics and Medical Informatics, Faculty of Medicine, Kocaeli University, Kocaeli, Turkey
| |
Collapse
|
2
|
Chen H, Feng S, Jin Y, Hou Y, Zhu S. Comparison of bond strength of universal adhesives using different etching modes: A systematic review and meta-analysis. Dent Mater J 2021; 41:1-10. [PMID: 34471040 DOI: 10.4012/dmj.2021-111] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This review aims to evaluate whether the etch-and-rinse or self-etch mode is the better protocol for dentin adhesion by universal adhesives. A total of 15 articles were included in the meta-analysis. Two reviewers performed a literature search up to October 2020in four databases: PubMed, Web of Science, Embase, and the Cochrane Library. Without considering the difference in aging mode, the analysis of the immediate and long-term bond strength of dentin showed that there was no statistical significance between the etch-and-rinse and self-etch mode of universal adhesive, and the long-term bond strength decreased relative to the immediate. In vitro studies suggest that prior acid etching did not improve bond performance. Whether from the perspective of long-term bonding performance or simplifying operating procedures, the self-etch mode is preferred.
Collapse
Affiliation(s)
- Huan Chen
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
| | - Shanshan Feng
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
| | - Yifu Jin
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
| | - Yanyan Hou
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
| | - Song Zhu
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University.,Department of Prosthodontics, Hospital of stomatology, Jilin University
| |
Collapse
|
3
|
Hardan L, Bourgi R, Kharouf N, Mancino D, Zarow M, Jakubowicz N, Haikel Y, Cuevas-Suárez CE. Bond Strength of Universal Adhesives to Dentin: A Systematic Review and Meta-Analysis. Polymers (Basel) 2021; 13:814. [PMID: 33799923 PMCID: PMC7961712 DOI: 10.3390/polym13050814] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 03/03/2021] [Accepted: 03/04/2021] [Indexed: 02/07/2023] Open
Abstract
Currently, the availability of a wide variety of universal adhesives makes it difficult for clinicians to choose the correct system for specific bonding situations to dentin substrate. This study aimed to determine whether there are any alternative techniques or additional strategies available to enhance the bond strength of universal adhesives to dentin through a systematic review and meta-analysis. Two reviewers executed a literature search up to September 2020 in four electronic databases: PubMed, ISI Web of Science, Scopus, and EMBASE. Only in vitro studies that reported the dentin bond strength of universal adhesives using additional strategies were included. An analysis was carried out using Review Manager Software version 5.3.5 (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). The methodological quality of each in vitro study was assessed according to the parameters of a previous systematic. A total of 5671 potentially relevant studies were identified. After title and abstract examination, 74 studies remained in systematic review. From these, a total of 61 studies were included in the meta-analysis. The bond strength of universal adhesives to dentin was improved by the use of one of the following techniques: Previous application of matrix metalloproteinases (MMP) inhibitors (p < 0.001), prolonged application time (p = 0.007), scrubbing technique (p < 0.001), selective dentin etching (p < 0.001), non-atmospheric plasma (p = 0.01), ethanol-wet bonding (p < 0.01), prolonged blowing time (p = 0.02), multiple layer application (p = 0.005), prolonged curing time (p = 0.006), and hydrophobic layer coating (p < 0.001). On the other hand, the use of a shortened application time (p = 0.006), and dentin desensitizers (p = 0.01) impaired the bond strength of universal adhesives to dentin. Most of the analyses performed showed a high heterogenicity. The in vitro evidence suggests that the application of universal adhesives using some alternative techniques or additional strategies may be beneficial for improving their bonding performance to dentin. This research received no external funding. Considering that this systematic review was carried out only with in vitro studies, registration was not performed.
Collapse
Affiliation(s)
- Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, 1107 2180 Beirut, Lebanon; (L.H.); (R.B.)
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, 1107 2180 Beirut, Lebanon; (L.H.); (R.B.)
| | - Naji Kharouf
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Biomaterials and Bioengineering, 67000 Strasbourg, France; (D.M.); (Y.H.)
- Department of Endodontics, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France
| | - Davide Mancino
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Biomaterials and Bioengineering, 67000 Strasbourg, France; (D.M.); (Y.H.)
- Department of Endodontics, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France
| | - Maciej Zarow
- Private Practice, “NZOZ SPS Dentist” Dental Clinic and Postgraduate Course Centre, pl. Inwalidow 7/5, 30-033 Cracow, Poland; (M.Z.); (N.J.)
| | - Natalia Jakubowicz
- Private Practice, “NZOZ SPS Dentist” Dental Clinic and Postgraduate Course Centre, pl. Inwalidow 7/5, 30-033 Cracow, Poland; (M.Z.); (N.J.)
| | - Youssef Haikel
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Biomaterials and Bioengineering, 67000 Strasbourg, France; (D.M.); (Y.H.)
| | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, Circuito Ex Hacienda La Concepción S/N, San Agustín Tlaxiaca, Hidalgo 42160, Mexico
| |
Collapse
|
4
|
Chen Y, Yan X, Li K, Zheng S, Sano H, Zhan D, Fu J. Effect of air-blowing temperature and water storage time on the bond strength of five universal adhesive systems to dentin. Dent Mater J 2020; 40:116-122. [PMID: 32863373 DOI: 10.4012/dmj.2019-280] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to evaluate the air-blowing temperature and water storage time on the micro-tensile bond strength (μTBS) of five universal adhesive systems to dentin. The bond strength with two different air-blowing temperatures (60±2ºC and 23±2ºC) was measured after water storage at 37ºC for 24 h and 100 days respectively. The fracture surface on dentin side was observed by scanning electron microscope (SEM). Three-way ANOVA revealed a significant effect of universal system (p<0.001) and air-blowing temperature (p<0.001) on bond strength to dentin except water-storage time (p=0.145). The interaction within three factors was significantly different (p<0.001). It could be concluded that the μTBS of universal systems to dentin was material-depended. The higher and more stable bonding performance of universal systems on dentin could be achieved by air-blowing at 60±2ºC temperature. In addition, the quantity of voids in the adhesive layer of aceton-based universal adhesive was significantly reduced by higher temperature.
Collapse
Affiliation(s)
- Yue Chen
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease
| | - Xiaoyuan Yan
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease
| | - Ke Li
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease
| | - Shize Zheng
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease.,School of Stomatology, Jilin University
| | - Hidehiko Sano
- Department of Restorative Dentistry, Division of Oral Health Science, Faculty of Dental Medicine, Hokkaido University
| | - Desong Zhan
- Department of Dental Materials Science, School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease
| | - Jiale Fu
- Department of Dental Materials Science, School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease
| |
Collapse
|
5
|
Manarte-Monteiro P, Domingues J, Teixeira L, Gavinha S, Manso MC. Multi-Mode adhesives performance and success/retention rates in NCCLs restorations: randomised clinical trial one-year report. Biomater Investig Dent 2019; 6:43-53. [PMID: 31998871 PMCID: PMC6964776 DOI: 10.1080/26415275.2019.1684199] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Accepted: 09/23/2019] [Indexed: 11/24/2022] Open
Abstract
Aim: Compare clinical performance and success/retention rates of two multi-mode (MM) adhesives, applied in self-etch (SE) or etch-and-rinse (ER) modes, with SE-all-in-one adhesive (SE/SE with enamel etching) in NCCL restorations at one-year follow-up. Material and methods: Prospective, double-blind RCT approved by the University Fernando Pessoa and the National-Clinical-Research-Ethics Committees (CEIC-20150305), ClinicalTrials.gov registered (NCT02698371), in 38 participants with 210 restorations (AdmiraFusion®) randomly allocated to six groups (Adhesives_Adhesion mode), each with 35 restorations: G1-Control Futurabond®DC_SE; G2-Control Futurabond®DC_SE with enamel etching; G3-Futurabond®U_ER; G4-Futurabond®U_SE; G5-Adhese®Universal_ER; G6-Adhese®Universal_SE. Restorations evaluated at baseline and one-year by three calibrated examiners (ICC ≥0.952) using FDI criteria and statistical analysis with nonparametric tests (alpha = 0.05). Results: At one-year recall 36 participants, 199 restorations were available for examination; five (2.5%) restorations (G1 n = 2; G2, G3, G4 n = 1) were lost due to retention (p > .05); G1 showed less satisfying marginal adaptation (p < .05) than G2 and MM adhesives groups, particularly G6. Overall success rates (p > .05) were: 93.9% (G1), 97.0% (G2; G3; G4) and 100.0% (G5; G6). Conclusions: MM adhesives (Futurabond®U and Adhese®Universal) showed similar and acceptable performance/success rates but also better clinical outputs than the SE-all-in-one adhesive (Futurabond®DC), particularly in SE mode. Success and retention rates were similar and not dependent on materials or adhesion modes.
Collapse
Affiliation(s)
- Patrícia Manarte-Monteiro
- Department of Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, Porto, Portugal
| | - Joana Domingues
- Department of Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, Porto, Portugal
| | - Liliana Teixeira
- Department of Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, Porto, Portugal
| | - Sandra Gavinha
- Department of Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, Porto, Portugal
| | - Maria Conceição Manso
- Biostatistics, Faculty of Health Sciences, UFP Energy, Environment and Health Research Unit (FP-ENAS), University Fernando Pessoa, Porto, Portugal
| |
Collapse
|