1
|
Zhu JE, Sheng CJ, Zhang HL, Li JX, Bo XW, Yin JJ, Yang P, Yu SY, Sun LP. Ultrasound-guided percutaneous microwave ablation of primary hyperthyroidism: security and efficacy analysis. Int J Hyperthermia 2024; 41:2424903. [PMID: 39532294 DOI: 10.1080/02656736.2024.2424903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 10/10/2024] [Accepted: 10/24/2024] [Indexed: 11/16/2024] Open
Abstract
OBJECTIVES This study aimed to analyze the safety, efficacy, and application prospects of ultrasound-guided microwave ablation (MWA) in the treatment of primary hyperthyroidism. METHODS Eight patients with primary hyperthyroidism who underwent ultrasound-guided glandular volume reduction between January 2021 and December 2022 were included in this study. Pre- and postablative examinations, including grayscale ultrasound, contrast-enhanced ultrasound (CEUS), laboratory examination, antithyroid drug (ATD) dosage, and quality of life (QoL) assessment via Thyroid-Specific Patient-Reported Outcome Short-Form (ThyPRO-39), were analyzed retrospectively. The main ultrasound follow-up times were 1, 3, 6, and 12 months after ablation. Thyroid function was reviewed 1 week after ablation, and the subsequent reexamination time was determined according to the patient's specific test results and ATD adjustment. The final efficacy was comprehensively analyzed according to the patient's medication status, thyroid function, thyroid volume, and QoL score. RESULTS All 8 patients successfully received MWA for primary hyperthyroidism, and none of them experienced serious complications. By the end of the follow-up, 5 of the 8 patients had stopped taking ATDs, 3 of the 8 patients had reduced ATD dosages, and all of them maintained stable thyroid function. Although descriptive analysis was performed because of the small sample size, patients' thyroid volume reduction, and obvious improvements in goiter symptoms, hyperthyroid symptoms, anxiety, etc., were observed during our follow-up. CONCLUSION Ultrasound-guided MWA for reducing thyroid gland volume in primary hyperthyroidism patients is a new, safe, and effective minimally invasive treatment method that is a good choice for patients who cannot or refuse traditional treatment methods.
Collapse
Affiliation(s)
- Jing-E Zhu
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Chun-Jun Sheng
- Treatment Center for Thyroid Disease, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China
| | - Hui-Li Zhang
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Jia-Xin Li
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Xiao-Wan Bo
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Jia-Jing Yin
- Treatment Center for Thyroid Disease, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China
| | - Peng Yang
- Treatment Center for Thyroid Disease, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China
| | - Song-Yuan Yu
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Li-Ping Sun
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| |
Collapse
|
2
|
Liu X, Liu D, Long M, Chen F. Application value of ultrasonic contrast imaging and ultrasonic parameters in post-transplant renal surgery. Front Med (Lausanne) 2024; 11:1397884. [PMID: 39257889 PMCID: PMC11383778 DOI: 10.3389/fmed.2024.1397884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Accepted: 07/30/2024] [Indexed: 09/12/2024] Open
Abstract
Objective Utilize VUEBOX quantitative analysis software to perform quantitative analysis dynamic ultrasound contrast images of post-transplant renal patients were assessed quantitatively five parameters of ultrasonic contrast and two-dimensional ultrasound are examined to explore their six value in Diagnosing Renal Graft Dysfunction. Methods A retrospective analysis was conducted on 73 post-transplant renal patients who underwent ultrasound contrast examinations at Yiyang Central Hospital from July 2022 to December 2023, They were diagnosed clinically and pathologically. Based on pathological and clinical diagnostic results, the patients were divided into three groups: 47 cases in the stable renal function group, 18 cases in the acute rejection (AR) group, and 8 cases in the delayed graft function (DGF) group. All patients underwent routine ultrasound and ultrasound contrast examinations post-transplantation. By comprehensively assessing renal function test results, clinical course, and pathological findings, differences in ultrasonic contrast quantitative parameters were analyzed. Additionally, ROC curves were constructed to evaluate the diagnostic efficacy of ultrasound contrast in discriminating between transplant renal rejection reactions and delayed renal function recovery. Results Statistically significant differences in characteristics, such as renal segmental artery resistance index, were observed among the stable renal function group, AR group, and DGF group (all P < 0.05), while peak systolic velocity showed no statistical significance (P > 0.05). Differences in cortical time to peak (TTP), medullary time to peak(TTP), main renal artery rise time (RT), main renal artery(TTP), and main renal artery fall time (FT) were statistically significant among the stable renal function group, AR group, and DGF group (P < 0.05). ROC curve analysis demonstrated that the accuracy of quantitative parameters for the DGF group and AR group was as follows: Renal artery TTP = Renal artery RT > Renal artery FT > Medulla TTP > Cortex TTP (with respective area under the curve values of 0.828, 0.828, 0.758, 0.742, 0.719). Among these, Renal artery TTP and Renal artery RT exhibited larger AUC values, with sensitivities of 87.5% each and specificities of 81.2 and 87.5%, respectively. Conclusion There are discernible differences in VUEBOX quantitative parameters between post-transplant AR and DGF cases, thereby providing imaging references for diagnosing of acute rejection and functional impairment following renal transplantation.
Collapse
Affiliation(s)
- Xinwei Liu
- The Affiliated Yiyang Central Hospital, Hunan University of Chinese Medicine, Yiyang, China
| | - Dikuan Liu
- The Affiliated Yiyang Central Hospital, Hunan University of Chinese Medicine, Yiyang, China
| | - Meizhen Long
- The Affiliated Yiyang Central Hospital, Hunan University of Chinese Medicine, Yiyang, China
| | - Feng Chen
- The Affiliated Yiyang Central Hospital, Hunan University of Chinese Medicine, Yiyang, China
| |
Collapse
|
3
|
Li HJ, Sui GQ, Teng DK, Lin YQ, Wang H. Incorporation of CEUS and SWE parameters into a multivariate logistic regression model for the differential diagnosis of benign and malignant TI-RADS 4 thyroid nodules. Endocrine 2024; 83:691-699. [PMID: 37889469 PMCID: PMC10902020 DOI: 10.1007/s12020-023-03524-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Accepted: 09/03/2023] [Indexed: 10/28/2023]
Abstract
PURPOSE To investigate the diagnostic value of contrast-enhanced ultrasound (CEUS) quantitative analysis parameters combined with shear wave elastography (SWE) quantitative parameters in the differentiation of benign and malignant ACR TI-RADS category 4 thyroid nodules and to provide a more effective reference for clinical work. METHODS We analyzed 187 category 4 nodules, including 132 nodules in the development cohort and 55 nodules in the validation cohort, divided the development cohort into benign and malignant groups, and analyzed the differences in all CEUS and SWE quantitative parameters between the two groups. We selected the highest AUC of the two parameters, performed binary logistic regression analysis with the ACR TI-RADS score and constructed a diagnostic model. ROC curves were applied to evaluate their diagnostic efficacy. RESULTS 1) The diagnostic model had an AUC of 0.926, sensitivity of 87.5%, specificity of 86.8%, diagnostic threshold of 3, accuracy of 87.12%, positive predictive value of 86.15%, and negative predictive value of 88.06%. 2) The diagnostic model had an AUC of 0.890 in the validation cohort, sensitivity of 81.5%, specificity of 79.6%, and accuracy of 80.00%. CONCLUSION The combined multiparameter construction of the nodule diagnostic model can effectively improve the diagnostic efficacy of 4 types of thyroid nodules and provide a new reference index for clinical diagnostic work.
Collapse
Affiliation(s)
- Hong-Jing Li
- Department of Ultrasound, China-Japan Union Hospital of Ji Lin University, Changchun, Jilin, China
| | - Guo-Qing Sui
- Department of Ultrasound, China-Japan Union Hospital of Ji Lin University, Changchun, Jilin, China
| | - Deng-Ke Teng
- Department of Ultrasound, China-Japan Union Hospital of Ji Lin University, Changchun, Jilin, China
| | - Yuan-Qiang Lin
- Department of Ultrasound, China-Japan Union Hospital of Ji Lin University, Changchun, Jilin, China.
| | - Hui Wang
- Department of Ultrasound, China-Japan Union Hospital of Ji Lin University, Changchun, Jilin, China.
| |
Collapse
|
4
|
Li LL, Su QL, Deng YX, Guo WW, Lun HM, Hu Q. Contrast-enhanced ultrasound for the preoperative prediction of pathological characteristics in breast cancer. Front Oncol 2024; 14:1320714. [PMID: 38487727 PMCID: PMC10937469 DOI: 10.3389/fonc.2024.1320714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Accepted: 02/13/2024] [Indexed: 03/17/2024] Open
Abstract
Objective We aimed to investigate the value of contrast-enhanced ultrasound (CEUS) in the preoperative prediction of the histological grades and molecular subtypes of breast cancer. Methods A total of 183 patients with pathologically confirmed breast cancer were included. Contrast enhancement patterns and quantitative parameters were compared in different groups. The receiver operating characteristic (ROC) curve was used to analyze the efficacy of CEUS in the preoperative prediction of pathological characteristics, including histologic grade and molecular subtypes. Results Heterogeneous enhancement, perfusion defects, and peripheral radial vessels were mostly observed in higher histologic grade (grade III) breast cancer. Heterogeneous enhancement and perfusion defect were the most effective indicators for grade III breast cancer, with the areas under the ROC curve of 0.768 and 0.756, respectively. There were significant differences in the enhancement intensity, post-enhanced margin, perfusion defects, and peripheral radial vessel among the different molecular subtypes of breast cancer (all P < 0.01). Perfusion defects and clear edge after enhancement were the best qualitative criteria for the diagnosis of HER-2 overexpressed and triple-negative breast cancers, and the corresponding areas under the ROC curves were 0.804 and 0.905, respectively. There were significant differences in PE, WiR, WiPI, and WiWoAUC between grade III vs grade I and II breast cancer (P < 0.05). PE, WiR, WiPI, and WiWoAUC had good efficiency in the diagnosis of high-histologic-grade breast cancer. PE had the highest diagnostic efficiency in Luminal A, while WiPI had the highest diagnostic efficiency in Luminal B subtype breast cancer, and the areas under the ROC curve were 0.825 and 0.838, respectively. WiWoAUC and WiR were the most accurate parameters for assessing triple-negative subtype breast cancers, and the areas under the curve were 0.932 and 0.922, respectively. Conclusion Qualitative and quantitative perfusion analysis of contrast-enhanced ultrasound may be useful in the non-invasive prediction of the histological grade and molecular subtypes of breast cancers.
Collapse
Affiliation(s)
- Ling-Ling Li
- Departments of Ultrasound, The People’s Hospital of Guangxi Zhuang Autonomous Region, Nanning, Guangxi, China
| | - Quan-Li Su
- Departments of Ultrasound, The People’s Hospital of Guangxi Zhuang Autonomous Region, Nanning, Guangxi, China
| | - Yun-Xia Deng
- Departments of Ultrasound, The People’s Hospital of Guangxi Zhuang Autonomous Region, Nanning, Guangxi, China
| | - Wen-Wen Guo
- Departments of Pathology, The People’s Hospital of Guangxi Zhuang Autonomous Region, Nanning, Guangxi, China
| | - Hai-Mei Lun
- Departments of Ultrasound, The People’s Hospital of Guangxi Zhuang Autonomous Region, Nanning, Guangxi, China
| | - Qiao Hu
- Departments of Ultrasound, The People’s Hospital of Guangxi Zhuang Autonomous Region, Nanning, Guangxi, China
| |
Collapse
|
5
|
Dietrich CF, Correas JM, Cui XW, Dong Y, Havre RF, Jenssen C, Jung EM, Krix M, Lim A, Lassau N, Piscaglia F. EFSUMB Technical Review - Update 2023: Dynamic Contrast-Enhanced Ultrasound (DCE-CEUS) for the Quantification of Tumor Perfusion. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2024; 45:36-46. [PMID: 37748503 DOI: 10.1055/a-2157-2587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Dynamic contrast-enhanced ultrasound (DCE-US) is a technique to quantify tissue perfusion based on phase-specific enhancement after the injection of microbubble contrast agents for diagnostic ultrasound. The guidelines of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) published in 2004 and updated in 2008, 2011, and 2020 focused on the use of contrast-enhanced ultrasound (CEUS), including essential technical requirements, training, investigational procedures and steps, guidance regarding image interpretation, established and recommended clinical indications, and safety considerations. However, the quantification of phase-specific enhancement patterns acquired with ultrasound contrast agents (UCAs) is not discussed here. The purpose of this EFSUMB Technical Review is to further establish a basis for the standardization of DCE-US focusing on treatment monitoring in oncology. It provides some recommendations and descriptions as to how to quantify dynamic ultrasound contrast enhancement, and technical explanations for the analysis of time-intensity curves (TICs). This update of the 2012 EFSUMB introduction to DCE-US includes clinical aspects for data collection, analysis, and interpretation that have emerged from recent studies. The current study not only aims to support future work in this research field but also to facilitate a transition to clinical routine use of DCE-US.
Collapse
Affiliation(s)
- Christoph F Dietrich
- Department General Internal Medicine, Kliniken Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland
- Zentrum der Inneren Medizin, Johann Wolfgang Goethe Universitätsklinik Frankfurt, Frankfurt, Germany
| | - Jean-Michel Correas
- Department of Adult Radiology, Assistance Publique Hôpitaux de Paris, Necker University Hospital, Paris, France
- Paris Cité University, Paris, France
- CNRS, INSERM Laboratoire d'Imagerie Biomédicale, Sorbonne Université, Paris, France
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yi Dong
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Roald Flesland Havre
- Department of Medicine, National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Christian Jenssen
- Department of Internal Medicine, Krankenhaus Märkisch Oderland Strausberg/ Wriezen, Wriezen, Germany
- Brandenburg Institute for Clinical Ultrasound (BICUS), Medical University Brandenburg, Neuruppin, Brandenburg, Germany
| | - Ernst Michael Jung
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Martin Krix
- Global Medical & Regulatory Affairs, Bracco Imaging, Konstanz, Germany
| | - Adrian Lim
- Department of Imaging, Imperial College London and Healthcare NHS Trust, Charing Cross Hospital Campus, London, United Kingdom of Great Britain and Northern Ireland
| | - Nathalie Lassau
- Imaging Department. Gustave Roussy cancer Campus. Villejuif, France. BIOMAPS. UMR 1281. CEA. CNRS. INSERM, Université Paris-Saclay, France
| | - Fabio Piscaglia
- Division of Internal Medicine, Hepatobiliary and Immunoallergic Diseases, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
- Dept of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| |
Collapse
|
6
|
Zhou BY, Liu H, Pu YY, Wang LF, Sun YK, Yin HH, Lu D, Ye X, Hu XY, Wang X, Han H, Xia HS, Zhao CK, Xu HX. Quantitative analysis of pre-treatment dynamic contrast-enhanced ultrasound for assessing the response of colorectal liver metastases to chemotherapy plus targeted therapy: a dual-institutional study. Abdom Radiol (NY) 2024; 49:414-424. [PMID: 37853236 DOI: 10.1007/s00261-023-04055-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 09/09/2023] [Accepted: 09/11/2023] [Indexed: 10/20/2023]
Abstract
OBJECTIVES To investigate the clinical value of pre-treatment quantitative contrast-enhanced ultrasound (CEUS) in assessing the response of colorectal liver metastases (CRLM) to chemotherapy plus targeted therapy. METHODS This study retrospectively enrolled 50 CRLM patients from the Zhongshan Hospital, Fudan University as the training cohort and 14 patients from Shanghai Tenth People's Hospital as the testing cohort. Patients underwent the CEUS examination before receiving chemotherapy (CAPOX, FOLFOX, FOLFIRI, or FOLFOXIRI) plus targeted therapy (Bevacizumab or Cetuximab). The therapy response was determined according to Response Evaluation Criteria in Solid Tumors version 1.1 based on pre-treatment CT and 3-month follow-up CT after therapy. Dynamic analysis was performed by VueBox® software. Time-intensity curves with quantitative perfusion parameters were obtained. In the training cohort, univariable and multivariable logistic regression analyses were used to develop the predictive model of therapy response. The predictive performance of the developed model was validated in the testing cohort. RESULTS After the logistic regression analyses, the peak enhancement (PE) (odds ratio = 1.640; 95% confidence intervals [CI] 1.022-2.633) and time to peak (TTP) (odds ratio = 0.495; 95% CI 0.246-0.996) were determined as independent predictive factors. PE and TTP generated from VueBox® were not affected by ultrasound instruments and contrast agent dosage in therapy response evaluation (P > 0.05). The logistic regression model achieved satisfactory prediction performance (area under the curve: 0.923 in the training cohort and 0.854 in the testing cohort). CONCLUSION CEUS with dynamic quantitative perfusion analysis, which presents high consistency, has potential practical value in predicting the response of CRLM to chemotherapy plus targeted therapy.
Collapse
Affiliation(s)
- Bo-Yang Zhou
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China
| | - Hui Liu
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, 200072, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, 200072, China
| | - Yin-Ying Pu
- Central Laboratory and Department of Medical Ultrasound, Sichuan Academy of Medical Sciences, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, 610072, China
| | - Li-Fan Wang
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Yi-Kang Sun
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Hao-Hao Yin
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Dan Lu
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Xing Ye
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Xin-Yuan Hu
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Xi Wang
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Hong Han
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Han-Sheng Xia
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China.
| | - Chong-Ke Zhao
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China.
| | - Hui-Xiong Xu
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China
| |
Collapse
|
7
|
Pang W, Wang Y, Zhu Y, Jia Y, Nie F. Predictive value for axillary lymph node metastases in early breast cancer: Based on contrast-enhanced ultrasound characteristics of the primary lesion and sentinel lymph node. Clin Hemorheol Microcirc 2024; 86:357-367. [PMID: 37955082 DOI: 10.3233/ch-231973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2023]
Abstract
OBJECTIVE To evaluate the value of contrast-enhanced ultrasound (CEUS) characteristics based on primary lesion combined with lymphatic contrast-enhanced ultrasound (LCEUS) patterns of SLN in predicting axillary lymph node metastasis (ALNM) with T1-2N0 breast cancer. METHODS A retrospective study was conducted in 118 patients with clinically confirmed T1-2N0 breast cancer. Conventional ultrasound (CUS) and CEUS characteristics of the primary lesion and enhancement patterns of SLN were recorded. The risk factors associated with ALNM were selected by univariate and binary logistic regression analysis, and the receiver operating characteristic (ROC) curve was drawn for the evaluation of predictive ALNM metastasis performance. RESULTS Univariate analysis showed that age, HER-2 status, tumor size, nutrient vessels, extended range of enhancement lesion, and the enhancement patterns of SLN were significant predictive features of ALNM. Further binary logistic regression analysis indicated that the extended range of enhancement lesion (p < 0.001) and the enhancement patterns of SLN (p < 0.001) were independent risk factors for ALNM. ROC analysis showed that the AUC of the combination of these two indicators for predicting ALNM was 0.931 (95% CI: 0.887-0.976, sensitivity: 75.0%, specificity: 99.8%). CONCLUSION The CEUS characteristics of primary lesion combined with enhancement patterns of SLN are highly valuable in predicting ALNM and can guide clinical axillary surgery decision-making in early breast cancer.
Collapse
Affiliation(s)
- Wenjing Pang
- Ultrasound Medical Center, Lanzhou University Second Hospital, Lanzhou, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Yao Wang
- Ultrasound Medical Center, Lanzhou University Second Hospital, Lanzhou, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Yangyang Zhu
- Ultrasound Medical Center, Lanzhou University Second Hospital, Lanzhou, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Yingying Jia
- Ultrasound Medical Center, Lanzhou University Second Hospital, Lanzhou, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Fang Nie
- Ultrasound Medical Center, Lanzhou University Second Hospital, Lanzhou, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| |
Collapse
|
8
|
Jung EM, Kaiser U, Herr W, Stroszczynski C, Jung F. Novel high-resolution contrast agent ultrasound techniques HiFR CEUS and SR CEUS in combination with shear wave elastography, fat assessment and viscosity of liver parenchymal changes and tumors. Clin Hemorheol Microcirc 2024; 86:263-273. [PMID: 38489171 DOI: 10.3233/ch-249103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2024]
Abstract
BACKGROUND The continuous development of ultrasound techniques increasingly enables better description and visualization of unclear lesions. New ultrasound systems must be evaluated with regard to all these diagnostic possibilities. METHODS A multifrequency C1-7 convex probe (SC7-1M) with the new high-end system Resona A20 Series was used. Modern technologies, including HiFR CEUS, SR CEUS and multimodal tissue imaging with shear wave elastography (SWE), fat evaluation and viscosity measurements (M-Ref) were applied. RESULTS Of n = 70 (mean value 48,3 years±20,3 years, range 18-84 years) cases examined, a definitive diagnosis could be made in n = 67 cases, confirmed by reference imaging and/or follow-up. Of these, n = 22 cases were malignant changes (HCC (hepatocellular carcinoma) n = 9, CCC (cholangiocellular carcinoma) n = 3, metastases of colorectal carcinomas or recurrences of HCC n = 10). In all 12 cases of HCC or CCC, the elastography measurements using the shear wave technique (with values >2 m/s to 3.7 m/s) showed mean values of 2.3±0.31 m/s and a degree of fibrosis of F2 to F4. In n = 14 cases, changes in the fat measurement (range 0.51 to 0.72 dB/cm/MHz, mean values 0.58±0.12 dB/cm/MHz) in the sense of proportional fatty changes in the liver were detected. In the 4 cases of localized fat distribution disorders, the values were >0.7 dB/cm/MHz in the sense of significant fatty deposits in the remaining liver tissue. Relevant changes in the viscosity measurements with values >1.8 kPa were found in n = 31 cases, in n = 5 cases of cystic lesions with partially sclerosing cholangitis, in n = 13 cases of malignant lesions and in n = 9 cases post-interventionally, but also in n = 4 cases of benign foci with additional systemic inflammation. CONCLUSIONS The results are promising and show a new quality of ultrasound-based liver diagnostics. However, there is a need for further investigations with regard to the individual aspects, preferably on a multi-center basis.
Collapse
Affiliation(s)
- Ernst Michael Jung
- Interdisciplinary Ultrasound Department, Institute of Diagnostic Radiology, University Hospital Regensburg, Regensburg, Germany
| | - Ulrich Kaiser
- Clinic and Polyclinic for Internal Medicine III, University Hospital Regensburg, Regensburg, Germany
| | - Wolfgang Herr
- Clinic and Polyclinic for Internal Medicine III, University Hospital Regensburg, Regensburg, Germany
| | - Christian Stroszczynski
- Interdisciplinary Ultrasound Department, Institute of Diagnostic Radiology, University Hospital Regensburg, Regensburg, Germany
| | - Friedrich Jung
- Molecular Cell Biology, Institute of Biotechnology, Brandenburg University of Technology, Senftenberg, Germany
| |
Collapse
|
9
|
Chen R, Liu D, Zhao H, Wang X. Renal medullary perfusion differs from that in renal cortex in patients with sepsis associated acute kidney injury and correlates with renal function prognosis: A prospective cohort study. Clin Hemorheol Microcirc 2024; 88:181-198. [PMID: 39121113 PMCID: PMC11492038 DOI: 10.3233/ch-242296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/11/2024]
Abstract
BACKGROUND Renal perfusion status remains poorly studied at the bedside during sepsis associated acute kidney injury (AKI). The aim of the study is to examine renal cortical and medullary perfusion using renal contrast enhanced ultrasound (CEUS) in septic patients. METHODS In this single-center, prospective longitudinal study, septic patients were enrolled. Renal ultrasonography was performed within 24 hours of ICU admission (D1), then repeated at D3, D5 and D7. Each measurement consisted of three destruction replenishment sequences that were recorded for delayed analysis with dedicated software (Vuebox). Renal cortex and medulla perfusion were quantified by measuring time to peak (TTP). Receiver operating characteristic (ROC) analysis was used to evaluate 28-day renal prognosis. RESULTS The study included 149 septic patients, including 70 non-AKI patients and 79 AKI patients. Both renal cortical and medullary TTP was longer in the AKI group than in the non-AKI group. The difference of TTP between renal cortex and medulla in AKI group was higher than that in the non-AKI group (p = 0.000). Medullary TTP on day 3 had the best performance in predicting the prognosis of 28-day renal function (AUC 0.673, 95% confidence interval 0.528-0.818, p = 0.024), and its cut-off value was 45 s with a sensitivity 52.2% and a specificity of 82.1%. Cortical TTP on day 3 also had the performance in predicting the prognosis of 28-day renal function (AUC 0.657, 95% confidence interval 0.514-0.800, p = 0.039), and its cut-off value was 33 s with a sensitivity 78.3% and a specificity of 55.0%. CONCLUSION Renal medullary perfusion alterations differ from those in cortex, with the medulla is worse. Simultaneous and dynamic assessment of cortical and medullary microcirculatory flow alterations necessary. TTP on day 3, especially medullary TTP, seems to be a relatively stable and useful indicator, which correlates with 28-day renal function prognosis in septic patients. Early correction of renal cortical and medullary perfusion alterations reduces the incidence of adverse renal events.
Collapse
Affiliation(s)
- Rongping Chen
- Peking Union Medical College Hospital, Beijing, China
| | - Dawei Liu
- Peking Union Medical College Hospital, Beijing, China
| | - Hua Zhao
- Peking Union Medical College Hospital, Beijing, China
| | - Xiaoting Wang
- Peking Union Medical College Hospital, Beijing, China
| |
Collapse
|
10
|
Zhang XL, Wang HT, Tang Y, Lu Q, Yuan HX, Wang X, Liu LH, Zhu DX, Wang WP. Colorectal liver metastases: Correlations of contrast-enhanced ultrasound features with tumor clinicopathological factors and clinical outcomes following conversion therapy. Clin Hemorheol Microcirc 2024; 86:339-356. [PMID: 37927253 DOI: 10.3233/ch-231963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2023]
Abstract
OBJECTIVE To explore the prognostic impact of contrast-enhanced ultrasound (CEUS) features for initially unresectable colorectal liver metastases (CLMs) in a clinical setting of conversion therapy. METHODS Between March 2015 and November 2020, consecutive patients with CLMs who received conversion treatment were prospectively enrolled. All participants underwent liver CEUS at baseline. The primary endpoint was conversion resection rate (R0 and overall resection). Secondary endpoints were objective response rate (ORR), overall survival (OS), and progression-free survival (PFS). RESULTS 104 participants who completed conversion treatment were included. CEUS enhancement pattern was correlated with index lesion (size and echogenicity), primary (site, differentiation, perineural invasion, and RAS genotype) and serum (CA19-9 level) characteristics (P = <0.001-0.016). CEUS enhancement pattern was significantly associated with R0 resection rate, ORR, PFS, and OS (P = 0.001-0.049), whereas enhancement degree was associated with PFS and OS (P = 0.043 and 0.045). Multivariate analysis showed that heterogeneous enhancement independently predicted R0 and overall resection (P = 0.028 and 0.024) while rim-like enhancement independently predicted ORR and OS (P = 0.009 and 0.026). CONCLUSION CEUS enhancement pattern was significantly associated with tumor characteristics and clinical outcomes following conversion therapy, and thus might be of prognosis impact for initially unresectable CLMs.
Collapse
Affiliation(s)
- Xiao-Long Zhang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Hang-Tao Wang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Yang Tang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Qing Lu
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Hai-Xia Yuan
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xi Wang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Li-Heng Liu
- Department of Radiology and Multi-Disciplinary Team of Colorectal Cancer, Zhongshan Hospital, Fudan University, Shanghai, China
| | - De-Xiang Zhu
- Department of General Surgery and Multi-Disciplinary Team of Colorectal Cancer, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Wen-Ping Wang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
11
|
Grynkiewicz M, Wiewióra M. A current role status of micro-ultrasound imaging in prostate cancer diagnosis. Clin Hemorheol Microcirc 2024; 87:89-100. [PMID: 38160349 DOI: 10.3233/ch-232024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
Recently diagnostic field in medicine was enriched by advances in ultrasonography (US) technology, which led to establishment of novel modalities, one of which is micro-ultrasound. Results demonstrated by early studies have been promising, simultaneously rising a question if those new modalities could become an alternative in diagnosis of prostatic carcinoma (PCa). To answer this question, several studies have been conducted where micro-ultrasound have been compared to standard diagnostic tools, such as conventional TRUS or mpMRI. Nevertheless, new technology presents with some limitations, which include inconsistent results, necessity for specialized equipment, need of training for investigators to understand the findings, and external validation. In this publication, we have identified studies that provided evaluation of the accuracy and efficiency of the micro-ultrasound technology. Additionally, analysis of the results provided a better understanding of the novel imaging tool when compared standard modalities in diagnosis of PCa. Increasing number of studies demonstrated that micro-ultrasound carries high detection rate of PCa and clinically significant prostatic cancer (csPCa), suggesting a similar performance to mpMRI and even showing superiority over conventional TRUS. Recent studies have also showed that micro-ultrasound takes active role in improving the detection of csPCa and guidance for prostate biopsy (PBx) as well as further treatment. Moreover, certain practical aspects such as lower costs, decreased waiting time, real-time imaging and application of the imaging tool for patients that are not suitable for mpMRI (contrast allergy, prosthetics etc.) are significant advantages. Analysis of the results still does not provide clear answer whether micro-ultrasound outperforms mpMRI. Further studies are necessary in order to completely understand the potential of this new technology.
Collapse
Affiliation(s)
- Michael Grynkiewicz
- Department of Urology, Pediatric Urology and Robot Assisted Minimally Invasive Urology, Sozialstiftung Bamberg, Hospital Bamberg, Bamberg, Germany
| | - Maciej Wiewióra
- Department of Cardiac Vascular and Endovascular Surgery and Transplantology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, Katowice, Poland
| |
Collapse
|
12
|
Kopyto E, Czeczelewski M, Mikos E, Stępniak K, Kopyto M, Matuszek M, Nieoczym K, Czarnecki A, Kuczyńska M, Cheda M, Drelich-Zbroja A, Jargiełło T. Contrast-Enhanced Ultrasound Feasibility in Assessing Carotid Plaque Vulnerability-Narrative Review. J Clin Med 2023; 12:6416. [PMID: 37835061 PMCID: PMC10573420 DOI: 10.3390/jcm12196416] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 09/25/2023] [Accepted: 09/28/2023] [Indexed: 10/15/2023] Open
Abstract
The risk assessment for carotid atherosclerotic lesions involves not only determining the degree of stenosis but also plaque morphology and its composition. Recently, carotid contrast-enhanced ultrasound (CEUS) has gained importance for evaluating vulnerable plaques. This review explores CEUS's utility in detecting carotid plaque surface irregularities and ulcerations as well as intraplaque neovascularization and its alignment with histology. Initial indications suggest that CEUS might have the potential to anticipate cerebrovascular incidents. Nevertheless, there is a need for extensive, multicenter prospective studies that explore the relationships between CEUS observations and patient clinical outcomes in cases of carotid atherosclerotic disease.
Collapse
Affiliation(s)
- Ewa Kopyto
- Students’ Scientific Society, Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (E.K.); (E.M.); (K.S.); (M.K.); (M.M.); (K.N.); (A.C.)
| | - Marcin Czeczelewski
- Students’ Scientific Society, Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (E.K.); (E.M.); (K.S.); (M.K.); (M.M.); (K.N.); (A.C.)
| | - Eryk Mikos
- Students’ Scientific Society, Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (E.K.); (E.M.); (K.S.); (M.K.); (M.M.); (K.N.); (A.C.)
| | - Karol Stępniak
- Students’ Scientific Society, Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (E.K.); (E.M.); (K.S.); (M.K.); (M.M.); (K.N.); (A.C.)
| | - Maja Kopyto
- Students’ Scientific Society, Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (E.K.); (E.M.); (K.S.); (M.K.); (M.M.); (K.N.); (A.C.)
| | - Małgorzata Matuszek
- Students’ Scientific Society, Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (E.K.); (E.M.); (K.S.); (M.K.); (M.M.); (K.N.); (A.C.)
| | - Karolina Nieoczym
- Students’ Scientific Society, Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (E.K.); (E.M.); (K.S.); (M.K.); (M.M.); (K.N.); (A.C.)
| | - Adam Czarnecki
- Students’ Scientific Society, Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (E.K.); (E.M.); (K.S.); (M.K.); (M.M.); (K.N.); (A.C.)
| | - Maryla Kuczyńska
- Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (M.K.); (M.C.); (A.D.-Z.); (T.J.)
| | - Mateusz Cheda
- Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (M.K.); (M.C.); (A.D.-Z.); (T.J.)
| | - Anna Drelich-Zbroja
- Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (M.K.); (M.C.); (A.D.-Z.); (T.J.)
| | - Tomasz Jargiełło
- Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, 20-594 Lublin, Poland; (M.K.); (M.C.); (A.D.-Z.); (T.J.)
| |
Collapse
|
13
|
Jung EM, Stroszczynski C, Jung F. Advanced multimodal imaging of solid thyroid lesions with artificial intelligence-optimized B-mode, elastography, and contrast-enhanced ultrasonography parametric and with perfusion imaging: Initial results. Clin Hemorheol Microcirc 2023:CH239102. [PMID: 37092219 PMCID: PMC10357218 DOI: 10.3233/ch-239102] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
Goal of the study was the assessment of AI-assisted diagnosis of solid thyroid foci with multimodal modern ultrasound imaging. 50 patients (26-81 years, 54.7±13.1 years) were included in the study. Multimodal ultrasound imaging by means of B-mode with linear probe (4-12 MHz) with option of automated documentation of findings by means of AI, with supplementary Ultra MicroAngiography (UMA) was used. Macrovascularisation was assessed by dynamic contrast ultrasonography (CEUS) with parametric evaluation and perfusion analysis, and microvascularization was assessed by combined strain and shear wave elastography on a novel high-performance ultrasound system (Resono R9/Mindray) by an experienced examiner with independent reading. The evaluation was performed according to TI-RADS III-V.The volume of the thyroid lobes on both sides averaged 39 ml±5 ml (27 to 69 ml). The 13 cases of histologically confirmed thyroid carcinomas (8 papillary, 2 medullary, 2 microfollicular, 1 anaplastic CA) with a mean size of 15 mm±6 mm (9-21 mm) were correctly evaluated by TI-RADS V on the basis of irregular shape, induration > 2.5 m or > 30kPA and striking wash-out kinetics. Tumor lymph nodes could only be correctly detected preoperatively in one case of medullary carcinoma according to the surgical findings, based on irregular vascularization with UMA in roundish shape with cortex > 4 mm, transverse diameter up to 11 mm. In 25 cases of inhomogeneous nodular goiter an evaluation with TI-RADS III was performed in 31 cases, in 4 cases with incomplete marginal contour, partial marginal vascularization with UMA and partial wash out with indurations up to 2.5 m/s 30 kPA an evaluation with TI-RADS IV and surgical excision for nodular goiter. In 12 cases regressive nodular changes without relevant malignancy criteria resulted in nodular goiter, with focal changes up to 1.5 cm in diameter, classified as requiring control with TI-RADS III. There were no relevant changes in findings in the controls after 6 months. From the AI tool, the 20/25 goiter nodes were assessed as TI-RADS III, 7/12 adenomas, 5 goiter nodes, and 5 adenomas as TI-RADS IV, 5/13 carcinomas as TI-RADS IV, and 8/13 carcinomas as TI-RADS V.Multimodal ultrasound diagnostics supported by AI has a high diagnostic potential for the evaluation of solid thyroid lesions and standardizes the reporting with digital representative image documentation. CEUS perfusion and modern elastography techniques allow targeted follow-up of TI-RADS III findings.
Collapse
Affiliation(s)
- E M Jung
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| | - C Stroszczynski
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| | - F Jung
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| |
Collapse
|
14
|
He M, Gao Q, Xiang J, Mao Q, Jiang T. Diagnostic Value of Qualitative and Quantitative Contrast-Enhanced Ultrasound for Pathological Subtypes of Small Solid Renal Masses. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023. [PMID: 36591796 DOI: 10.1002/jum.16169] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 12/16/2022] [Accepted: 12/19/2022] [Indexed: 06/17/2023]
Abstract
OBJECTIVES To assess the diagnostic value of qualitative and quantitative contrast-enhanced ultrasound (CEUS) for pathological subtypes of small solid renal masses (sSRMs). METHODS Patients with sSRMs confirmed by surgical pathology from January 2019 to November 2021 were retrospectively identified. All patients were divided into 3 groups: clear cell renal cell carcinoma (ccRCC) group, none-ccRCC group (renal cell carcinoma other than ccRCC), and angiomyolipoma (AML) group. The mass position, size, echogenicity and blood flow signals were compared. The speed of wash-in, wash-out, the degree of peak enhancement and the homogeneity at peak enhancement, the presence of pseudocapsule sign in CEUS imaging were qualitatively evaluated. Peak enhancement, wash-in area under the curve (WiAUC), rise time, time to peak, wash-in rate (WiR), wash-in perfusion index (WiPI) and tumor-to-cortex enhancement ratio of the above parameters in CEUS imaging were quantitatively evaluated. RESULTS Of 105 patients, 105 sSRMs (66 ccRCC, 18 none-ccRCC, 21 AML) were enrolled in this study. No significant differences were found on location, size and echogenicity among 3 groups (all P > .05). The proportion of fast-washout and hypo-enhancement were highest in none-ccRCC group. Heterogeneous enhancement was detected in 87.88% in ccRCC group which is significantly higher than other 2 groups. Hundred percent of the AML showed no pseudocapsule sign, which is the highest among the 3 groups. Peak enhancement, WiAUC, WiR, WiPI of ccRCC group were the highest among the 3 groups. CONCLUSIONS Qualitative and quantitative CEUS not only has the diagnostic value in distinguishing AML from malignant sSRMs, but also helps to differentiate the pathological subtypes of sSRMs.
Collapse
Affiliation(s)
- Mengna He
- Department of Ultrasound, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Qiong Gao
- Department of Ultrasound, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Jianjian Xiang
- Department of Ultrasound, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Qiqi Mao
- Department of Urinary Surgery, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Tian'an Jiang
- Department of Ultrasound, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
15
|
Jung EM, Dong Y, Jung F. Current aspects of multimodal ultrasound liver diagnostics using contrast-enhanced ultrasonography (CEUS), fat evaluation, fibrosis assessment, and perfusion analysis - An update. Clin Hemorheol Microcirc 2023; 83:181-193. [PMID: 36776044 PMCID: PMC9986700 DOI: 10.3233/ch-239100] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
Current ultrasound multifrequency probes allow both improved detail resolution and depth of penetration when examining the liver. Also, new developments in vascular diagnostics, elastography with fibrosis assessment, evaluation of possible steatosis, and parametric and time intensity curve (TIC) analysis of dynamic microvascularization of the liver with contrast-enhanced ultrasound sonography (CEUS) complement ultrasound-guided diagnostics. State-of-the-art high-resolution technology includes a high frame rate (HiFR) mode for CEUS, fast shear wave measurements with the sound touch quantify (STQ) mode, artifact-free flow detection using HR flow and glazing flow in combination with a special flow-adapted imaging (Ultra Micro Angiography, UMA) and additionally different assessments of possible fatty liver (UltraSound ATtenuation Imaging Technology, USAT). In 50 cases with focal liver lesions, a multimodal liver diagnosis was performed with a still new high-performance ultrasound system as part of the clarification of questions from the university liver consultation and tumor outpatient clinic.
Collapse
Affiliation(s)
- E M Jung
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Yi Dong
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - F Jung
- Institute of Biotechnology, Brandenburg University of Technology, Senftenberg, Germany
| |
Collapse
|
16
|
Kaiser U, Herr W, Greiner B, Stroszczynski C, Jung EM. Mobile handheld ultrasound with VScan Air for the diagnosis of deep vein thrombosis. Clin Hemorheol Microcirc 2023; 83:149-161. [PMID: 36278343 DOI: 10.3233/ch-221598] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE This study aimed to evaluate a new W-Lan-supported ultrasound mobile technology for the diagnosis of vascular peripheral thrombosis. MATERIAL AND METHODS Fifty patients were examined by an experienced reference sonographer using high-end technology and a W-Lan supported device (VScan Air) to evaluate its diagnostic capabilities for peripheral thrombosis. RESULTS Fifty patients were examined (age, 25-88 years; male, n = 27, female n = 23). Thromboses were diagnosed in the neck (n = 1), upper leg (n = 7), lower leg (n = 49), and muscle veins (n = 25). VScan Air technique also allows the diagnosis of circumscribed deep vein thrombosis with a sufficient diagnostic certainty. Moreover, for superficial thrombi that can be well-delineated, a maximum image quality is possible compared to high-end technology. CONCLUSION The mobile VScan technology opens up new possibilities for near-patient and location-independent imaging in cases of deep vein thrombosis.
Collapse
Affiliation(s)
- Ulrich Kaiser
- Medical Clinic and Polyclinic III, University Hospital Regensburg, Regensburg, Germany
| | - Wolfgang Herr
- Medical Clinic and Polyclinic III, University Hospital Regensburg, Regensburg, Germany
| | - Barbara Greiner
- Institute for Diagnostic Radiology and Interdisciplinary Ultrasound, University Hospital Regensburg, Regensburg, Germany
| | - Christian Stroszczynski
- Institute for Diagnostic Radiology and Interdisciplinary Ultrasound, University Hospital Regensburg, Regensburg, Germany
| | - Ernst-Michael Jung
- Institute for Diagnostic Radiology and Interdisciplinary Ultrasound, University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
17
|
Li N, Hu Z, Liu Y, Ding J, Han P, Jing X, Kan Y. Dynamic contrast-enhanced ultrasound characteristics of renal tumors: VueBox™ quantitative analysis. Clin Hemorheol Microcirc 2023; 85:341-354. [PMID: 37742629 DOI: 10.3233/ch-231750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/26/2023]
Abstract
BACKGROUND VueBoxtrademark has been used for contrast analysis in DCE-US-based quantitative research. OBJECTIVE Aim of this study was to use the enhancement-mode and VueBoxtrademark parameters to further evaluate the differential diagnostic value of DCE-US for renal tumors. METHODS 24 patients with renal tumors, including 7 benign and 17 malignant, were retrospectively analyzed.The DCE-US enhancement-mode and VueBoxtrademark parameters correlated with the histological analyses of tumors were obtained and analyzed. RESULTS The benign and malignant renal tumors showed significant differences in enhancement degree (P = 0.017) and presence of a pseudocapsule (P = 0.009) and in the VueBoxtrademark parameters FT (P = 0.045) and RT (P = 0.039). Receiver operating characteristic analysis for differential diagnosis of benign and malignant renal tumors showed that AUC for a combination of enhancement degree and presence of a pseudocapsule was greater (AUC = 0.815) than the values for either parameter of enhancement mode alone. Similarly, the AUC for a combination of RT and FT was greater (AUC = 0.798) than the values for RT or FT alone. A comprehensive index obtaining by combining the enhancement-mode and VueBoxtrademark parameters showed the largest AUC (AUC = 0.916) with relatively high accuracy (87.50%), sensitivity (76.50%), and specificity (85.70%). CONCLUSIONS DCE-US with enhancement mode and quantitative analysis can facilitate preoperative differential diagnosis of benign and malignant renal tumors.
Collapse
Affiliation(s)
- Ning Li
- Department of Ultrasound, North China University of Science and Technology Affiliated Hospital, Tangshan, Hebei, China
| | - Ziyue Hu
- Department of Ultrasound, The Third Central Hospital of Tianjin, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
| | - Yang Liu
- Department of Ultrasound, North China University of Science and Technology Affiliated Hospital, Tangshan, Hebei, China
| | - Jianmin Ding
- Department of Ultrasound, The Third Central Hospital of Tianjin, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
| | - Pengcheng Han
- College of Stomatology, Tianjin Medical University, Tianjin, China
| | - Xiang Jing
- Department of Ultrasound, The Third Central Hospital of Tianjin, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
| | - Yanmin Kan
- Department of Ultrasound, North China University of Science and Technology Affiliated Hospital, Tangshan, Hebei, China
- Department of Ultrasound, The Third Central Hospital of Tianjin, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
| |
Collapse
|
18
|
Jung EM, Moran VO, Engel M, Krüger-Genge A, Stroszczynski C, Jung F. Modified contrast-enhanced ultrasonography with the new high-resolution examination technique of high frame rate contrast-enhanced ultrasound (HiFR-CEUS) for characterization of liver lesions: First results. Clin Hemorheol Microcirc 2023; 83:31-46. [PMID: 35466932 PMCID: PMC9986702 DOI: 10.3233/ch-221449] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AIM To examine to what extent the high frame rate contrast-enhanced ultrasound (HiFR) diagnostic enables the conclusive diagnosis of liver changes with suspected malignancy. MATERIAL/METHODS Ultrasound examinations were performed by an experienced examiner using a multifrequency probe (SC6-1) on a high-end ultrasound system (Resona 7, Mindray) to clarify liver changes that were unclear on the B-scan. A bolus of 1-2.4 ml of the Sulphur hexafluoride ultrasound microbubbles contrast agent SonoVue™ (Bracco SpA, Italy) was administered with DICOM storage of CEUS examinations from the early arterial phase (5-15 s) to the late phase (5-6 min). Based on the image files stored in the PACS, an independent reading was performed regarding image quality and finding-related diagnostic significance (0 not informative/non-diagnostic to 5 excellent image quality/confident diagnosis possible). References were clinical follow-up, if possible, comparison to promptly performed computed tomography or magnetic resonance imaging, in some cases also to histopathology. RESULTS We examined 100 patients (42 women, 58 men, from 18 years to 90 years, mean 63±13 years) with different entities of focal and diffuse liver parenchymal changes, which could be detected in all cases with sufficient image quality with CEUS and with high image quality with HiFR-CEUS. Proportionally septate cysts were found in n = 19 cases, scars after hemihepatectomy with local reduced fat in n = 5 cases, scars after microwave ablation in n = 19 cases, hemangiomas in n = 9 cases, focal nodular hyperplasia in n = 8 cases, colorectal metastases in n = 15 cases, hepatocellular carcinoma (HCC) in n = 11 cases, Osler disease in n = 8 cases. The size of lesions ranged from 5 mm to 200 mm with a mean value of 33.1±27.8 mm. Conclusive diagnoses could be made by the experienced investigator in 97/100 cases with CEUS, confirmed by reference imaging, in parts by histopathology or follow-up. The image quality for HiFR CEUS was rated with a score of 3 to 5; 62 cases were assessed with an average of good (4 points), 27 cases with very good (5 points), and in 11 cases (3 points) still satisfactory despite aggravated acoustic conditions. The specificity of HIFR-CEUS was 97%, the sensitivity 97%, the positive predictive value 94%, the negative predictive value 99% and the accuracy 97%. CONCLUSION HIFR-CEUS has demonstrated has demonstrated an improved image quality resulting in a high diagnostic accuracy. In the hands of an experienced investigator, HiFR-CEUS allows the assessment of focal and diffuse unclear liver parenchymal changes on B-scan and dynamic assessment of microcirculation in solid and vascular changes.
Collapse
Affiliation(s)
- Ernst Michael Jung
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Valentina Ocaña Moran
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Martin Engel
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Anne Krüger-Genge
- Department of Healthcare, Biomaterials and Cosmeceuticals, Fraunhofer-Institute for Applied Polymer Research, Potsdam-Golm, Germany
| | - Christian Stroszczynski
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Friedrich Jung
- Institute of Biotechnology, Molecular Cell Biology, Brandenburg University of Technology, Senftenberg, Germany
| |
Collapse
|
19
|
Kaiser U, Dropco I, Reuthner K, Ertl M, Schlitt HJ, Herr W, Stroszczynski C, Jung EM. Wireless handheld focused ultrasound in student teaching during the COVID-19 pandemic: Initial results of a pilot study1. Clin Hemorheol Microcirc 2023; 85:297-305. [PMID: 36502312 DOI: 10.3233/ch-229104] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVE The study aim was to investigate the use of a novel device, the Vscan Air™, for rapidly and effectively performing ultrasound in student teaching during the COVID-19 pandemic. MATERIAL AND METHODS As part of the ultrasound practical course with integrated hands-on activity required by the regular medical curriculum, 100 medical students were instructed in the use of the Vscan Air™, including duplex mode. They then evaluated the quality of the ultrasound images obtained by the Vscan Air™ from previously selected organs. RESULTS 100 students were interviewed (female n = 68, male n = 32; age >18 years n = 100). The rated image quality never fell below a mean of 3 for the examined organs and portal vein flow (liver 4,58; spleen 3,99; kidneys 4,29; aorta 4,16; Douglas/rectovesical space 4,14; portal vein 4,43; pancreas 3,53; Focused Assessment with Sonography for Trauma 4,38). Scores below 3 were found sporadically in ultrasounds of the spleen (n = 4), kidneys (n = 3), Douglas/rectovesical space (n = 2), and pancreas (n = 15). The liver was rated the lowest for 59 ratings. The portal vein was evaluated in 68 cases. The hepatic artery and hepatic veins could be also visualized in all 68 examinations. The aorta was evaluated in 62 cases. CONCLUSION The Vscan Air™ technology offered adequate image quality and provided a new, fast and patient-oriented technique to support continuous ultrasound examinations and education of students, especially during a pandemic. Particularly noteworthy is the uncomplicated compliance with the required high level of hygiene.
Collapse
Affiliation(s)
- Ulrich Kaiser
- Medical Clinic and Polyclinic III, University Hospital Regensburg, Regensburg, Germany
| | - Ivor Dropco
- Clinic and Polyclinic for Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Kathrin Reuthner
- Medical Clinic and Polyclinic III, University Hospital Regensburg, Regensburg, Germany
| | - Michael Ertl
- Department of Medical Technology, University Hospital Regensburg, Regensburg, Germany
| | - Hans Jürgen Schlitt
- Clinic and Polyclinic for Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Wolfgang Herr
- Medical Clinic and Polyclinic III, University Hospital Regensburg, Regensburg, Germany
| | - Christian Stroszczynski
- Institute for Diagnostic Radiology and Interdisciplinary Ultrasound, University Hospital Regensburg, Regensburg, Germany
| | - Ernst Michael Jung
- Institute for Diagnostic Radiology and Interdisciplinary Ultrasound, University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
20
|
Huang X, Nie F, Zhu J, Liu L, Wang N. Application value of shear-wave elastography combined with monochrome superb microvascular imaging in renal allograft chronic rejection. Clin Hemorheol Microcirc 2022; 82:303-311. [PMID: 36057814 DOI: 10.3233/ch-221443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
BACKGROUND Conventional ultrasound (US), which include gray scale US and Doppler US, is the first-line imaging modality for the evaluation of renal allograft; however, conventional US indicators have limitations. OBJECTIVE To explore the application value of shear-wave elastography (SWE) combined with monochrome superb microvascular imaging (mSMI) in renal allograft chronic rejection (CR). METHODS From November 2021 to February 2022 in the Lanzhou University Second Hospital, the US features of 54 patients with renal allograft were retrospectively analyzed. Patients were categorized into two groups: stable group(n = 44) and CR group(n = 10), with clinical diagnosis as reference standard. The vascular index (VI) on mSMI and parenchymal stiffness were measured in the middle cortex of all renal allografts and receiver operating characteristic (ROC) curves were drawn to evaluate the feasibility of differentiation. Statistically significant US features and biochemical indicators such as creatinine were scored, and the results of the scores were analyzed by ROC curve. RESULTS The VI on mSMI of the stable group (49.5±2.0) was significantly greater than that of the CR group (33.8±5.9) (P = 0.028). There was a statistically significant difference in parenchymal stiffness between stable group (16.2kPa±1.2) and CR group (33.9kPa±6.6) (P = 0.027). The sensitivity was 90% and specificity was 81.8% of the scores in the differentiation of stable group from CR group (cut-off value, 2; P = 0.000). CONCLUSION SWE combined with mSMI may help differentiate stable renal allograft from renal allograft CR and have the potential application value in the diagnosis of renal allograft CR.
Collapse
Affiliation(s)
- Xiao Huang
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China.,Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Fang Nie
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China.,Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Ju Zhu
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China.,Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Luping Liu
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China.,Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Nan Wang
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China.,Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| |
Collapse
|
21
|
Wang D, Zhao CK, Wang HX, Lu F, Li XL, Guo LH, Sun LP, Fu HJ, Zhang YF, Xu HX. Ultrasound-based computer-aided diagnosis for cytologically indeterminate thyroid nodules with different radiologists. Clin Hemorheol Microcirc 2022; 82:217-230. [PMID: 35848013 DOI: 10.3233/ch-221423] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
PURPOSE To evaluate a computer-aided diagnosis (CAD) technique in predicting malignancy for cytologically indeterminate thyroid nodules (TNs) as compared with different experienced radiologists. METHOD 436 patients with 436 cytologically indeterminate TNs on fine-needle aspiration cytology (FNAC) were included and all were confirmed by surgical pathology. They were retrospectively analyzed with respect to ultrasound (US) characteristics using a commercially available CAD system (AmCAD-UT; AmCad BioMed, Taiwan, China) and reviewed by one junior and one senior radiologists.The CAD system and different experienced radiologists stratified the risk of malignancy using ACR TI-RADS category. The diagnostic performance by different experienced radiologists independently and after consulting the CAD (different experienced radiologists + CAD) and by the CAD alone were compared. RESULTS The different experienced radiologists showed significantly higher specificities than the CAD system alone. The combination of radiologist and CAD system showed improved diagnostic performance with an AUC (Area under the curve) of 0.740 in the senior radiologist and 0.677 in the junior radiologist, as compared with CAD (AUC: 0.585) alone (all P < 0.05). The combination of senior radiologist and CAD system had the highest diagnostic performance (AUC: 0.740) and specificity (68.9%) compared to the others (all P < 0.05). CONCLUSION The CAD system may play the potential role as a decision-making assistant alongside radiologists for differential diagnosis of TNs with indeterminate cytology.
Collapse
Affiliation(s)
- Dan Wang
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China.,Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China.,Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
| | - Chong-Ke Zhao
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
| | - Han-Xiang Wang
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China.,Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China.,Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
| | - Feng Lu
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China.,Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China.,Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
| | - Xiao-Long Li
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China.,Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China.,Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
| | - Le-Hang Guo
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China.,Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China.,Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
| | - Li-Ping Sun
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China.,Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China.,Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
| | - Hui-Jun Fu
- Department of Pathology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Yi-Feng Zhang
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China.,Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China.,Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
| | - Hui-Xiong Xu
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
| |
Collapse
|
22
|
Imaging perfusion changes in oncological clinical applications by hyperspectral imaging: a literature review. Radiol Oncol 2022; 56:420-429. [PMID: 36503709 PMCID: PMC9784371 DOI: 10.2478/raon-2022-0051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Accepted: 11/02/2022] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Hyperspectral imaging (HSI) is a promising imaging modality that uses visible light to obtain information about blood flow. It has the distinct advantage of being noncontact, nonionizing, and noninvasive without the need for a contrast agent. Among the many applications of HSI in the medical field are the detection of various types of tumors and the evaluation of their blood flow, as well as the healing processes of grafts and wounds. Since tumor perfusion is one of the critical factors in oncology, we assessed the value of HSI in quantifying perfusion changes during interventions in clinical oncology through a systematic review of the literature. MATERIALS AND METHODS The PubMed and Web of Science electronic databases were searched using the terms "hyperspectral imaging perfusion cancer" and "hyperspectral imaging resection cancer". The inclusion criterion was the use of HSI in clinical oncology, meaning that all animal, phantom, ex vivo, experimental, research and development, and purely methodological studies were excluded. RESULTS Twenty articles met the inclusion criteria. The anatomic locations of the neoplasms in the selected articles were as follows: kidneys (1 article), breasts (2 articles), eye (1 article), brain (4 articles), entire gastrointestinal (GI) tract (1 article), upper GI tract (5 articles), and lower GI tract (6 articles). CONCLUSIONS HSI is a potentially attractive imaging modality for clinical application in oncology, with assessment of mastectomy skin flap perfusion after reconstructive breast surgery and anastomotic perfusion during reconstruction of gastrointenstinal conduit as the most promising at present.
Collapse
|
23
|
Brandenstein M, Wiesinger I, Künzel J, Hornung M, Stroszczynski C, Jung EM. Multiparametric Sonographic Imaging of Thyroid Lesions: Chances of B-Mode, Elastography and CEUS in Relation to Preoperative Histopathology. Cancers (Basel) 2022; 14:cancers14194745. [PMID: 36230668 PMCID: PMC9564296 DOI: 10.3390/cancers14194745] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 09/21/2022] [Accepted: 09/23/2022] [Indexed: 12/03/2022] Open
Abstract
Simple Summary As the incidence of thyroid lesions in Europe is rising, more and more people affected by thyroid pathologies seek treatment in a clinic. Every suspicious thyroid nodule needs to be confirmed as benign or malignant in order to be treated correctly. Unnecessary invasive diagnostics and thyroid surgery should be avoided. The aim of this retrospective study was to improve the distinction between benign and malignant nodules by using new high-performance multiparametric ultrasound examination techniques. By analyzing 122 thyroid nodules we created a score-based system combining B-mode, shear-wave elastography and contrast-enhanced ultrasound malignancy criteria. This system allows for a quite accurate detection of thyroid carcinomas with a sensitivity of 95% and specificity of 75.49%. Shear-wave elastography and contrast-enhanced ultrasound can detect unique malignancy features, which cannot be found in B-mode. Therefore, these criteria would present a relevant addition to the B-mode TI-RADS classification. Abstract Background: The aim was to improve preoperative diagnostics of solid non-cystic thyroid lesions by using new high-performance multiparametric ultrasound examination techniques. Methods: Multiparametric ultrasound consists of B-mode, shear-wave elastography and contrast enhanced ultrasound (CEUS) including Time-Intensity-Curve (TIC) analysis. A bolus of 1–2.4 mL Sulfur Hexafluorid microbubbles was injected for CEUS. Postoperative histopathology was the diagnostic gold standard. Results: 116 patients were included in this study. 102 benign thyroid nodules were diagnosed as well as 20 carcinomas. Suspicious B-mode findings like microcalcifications, a blurry edge and no homogeneous sonomorphological structure were detected in 60, 75 and 80% of all carcinomas but only in 13.7, 36.3 and 46.1% of all benign lesions. The average shear-wave elastography measurements of malignant lesions (4.6 m/s or 69.8 kPa centrally and 4.2 m/s or 60.1 kPa marginally) exceed the values of benign nodules. Suspicious CEUS findings like a not-homogeneous wash-in and a wash-out were detected almost twice as often in carcinomas. Conclusion: Multiparametric ultrasound offers new possibilities for the preoperative distinction between benign and malignant thyroid nodules. A score based system of B-mode, shear-wave and CEUS malignancy criteria shows promising results in the detection of thyroid carcinomas. It reaches a sensitivity of 95% and specificity of 75.49%.
Collapse
Affiliation(s)
- Moritz Brandenstein
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital, 93053 Regensburg, Germany
- Correspondence: ; Tel.: +49-17-647-793-303
| | - Isabel Wiesinger
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital, 93053 Regensburg, Germany
| | - Julian Künzel
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital of Regensburg, 93053 Regensburg, Germany
| | - Matthias Hornung
- Department of Surgery, University Hospital, 93053 Regensburg, Germany
| | - Christian Stroszczynski
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital, 93053 Regensburg, Germany
| | - Ernst-Michael Jung
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital, 93053 Regensburg, Germany
| |
Collapse
|
24
|
Li Q, Nie F, Yang D, Dong T, Liu T. Contrast-enhanced ultrasound (CEUS) - A new tool for evaluating blood supply in primary peripheral lung cancer. Clin Hemorheol Microcirc 2022; 83:61-68. [PMID: 36031889 DOI: 10.3233/ch-221484] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVES To explore the feasibility of contrast-enhanced ultrasound (CEUS) as a new tool for characterizing vascularization of primary peripheral lung cancer. METHODS 315 consecutive patients with definite primary peripheral lung cancers underwent CEUS examination from November 2016 to March 2022. CEUS parameters including time to enhancement (TE), time to peak (TP), time to wash-out (TW), distribution of vessels (DV), extent of enhancement (EE) and homogeneity of enhancement (HE) were obtained. RESULTS The lesions were grouped on the basis of TE which reflects tumor vascularization: early enhancement (pulmonary arterial vascularization) (n = 91) and delayed enhancement group (bronchial arterial vascularization) (n = 224). Overall, lung tumors commonly (71.1%) manifested a delayed enhancement which indicating blood supply originated from bronchial arteries, while an early enhancement was present in less than a third of the cases. Tumors with bronchial vascularization tended to show a delayed, reduced and heterogeneous enhancement. Correspondingly, it is characterized by a shorter TE, marked EE and a relatively infrequent occurrence of necrosis in tumors with pulmonary vascularization. CONCLUSIONS Providing micro-perfusion information, CEUS is a potentially imaging tool for evaluating blood supply in primary peripheral lung cancer.
Collapse
Affiliation(s)
- Qi Li
- Ultrasound Medical Center, Lanzhou University Second Hospital, Gansu, China
| | - Fang Nie
- Ultrasound Medical Center, Lanzhou University Second Hospital, Gansu, China
| | - Dan Yang
- Ultrasound Medical Center, Lanzhou University Second Hospital, Gansu, China
| | - Tiantian Dong
- Ultrasound Medical Center, Lanzhou University Second Hospital, Gansu, China
| | - Ting Liu
- Ultrasound Medical Center, Lanzhou University Second Hospital, Gansu, China
| |
Collapse
|
25
|
Yin L, Agyekum EA, Zhang Q, Pan L, Wu T, Xiao X, Qian XQ. Differentiation Between Granulomatous Lobular Mastitis and Breast Cancer Using Quantitative Parameters on Contrast-Enhanced Ultrasound. Front Oncol 2022; 12:876487. [PMID: 35912226 PMCID: PMC9335943 DOI: 10.3389/fonc.2022.876487] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 06/20/2022] [Indexed: 12/03/2022] Open
Abstract
Objective To investigate the Contrast-enhanced ultrasound (CEUS) imaging characteristics of granulomatous lobular mastitis (GLM) and the value of differentiating GLM from breast cancer. Materials and methods The study included 30 women with GLM (mean age 36.7 ± 5 years [SD]) and 58 women with breast cancer (mean age 48. ± 8 years [SD]) who were scheduled for ultrasound-guided tissue biopsy. All patients were evaluated with conventional US and CEUS prior to the biopsy. In both groups, the parameters of the quantitative and qualitative analysis of the CEUS were recorded and compared. The receiver-operating-characteristics curves (ROC) were created. Sensitivity, specificity, cut-off, and area under the curve (AUC) values were calculated. Results TTP values in GLM were statistically higher than in breast cancer (mean, 27.63 ± 7.29 vs. 20.10 ± 6.11), but WIS values were lower (mean, 0.16 ± 0.05 vs. 0.28 ± 0.17). Rich vascularity was discovered in 54.45% of breast cancer patients, but only 30.00% of GLM patients had rich vascularity. The AUC for the ROC test was 0.791 and 0.807, respectively. The optimal cut-off value for TTP was 24.5s, and the WIS cut-off value was 0.185dB/s, yielding 73.33% sensitivity, 84.48% specificity, and 86.21% sensitivity, 70% specificity respectively in the diagnosis of GLM. The lesion scores reduced from 4 to 3 with the addition of CEUS for the patients with GLM. However, the scores did not change for the patients with breast cancer. Conclusion CEUS could help distinguish GLM from breast cancer by detecting higher TTP and WIS values, potentially influencing clinical decision-making for additional biopsies.
Collapse
Affiliation(s)
- Liang Yin
- Department of Breast Surgery, Jiangsu University Affiliated People’s Hospital, Zhenjiang, China
- *Correspondence: Liang Yin,
| | - Enock Adjei Agyekum
- Department of Ultrasound, Jiangsu University Affiliated People’s Hospital, Zhenjiang, China
| | - Qing Zhang
- Department of Ultrasound, Jiangsu University Affiliated People’s Hospital, Zhenjiang, China
| | - Lei Pan
- Department of Breast Surgery, Jiangsu University Affiliated People’s Hospital, Zhenjiang, China
| | - Ting Wu
- Department of Pathology, Jiangsu University Affiliated People’s Hospital, Zhenjiang, China
| | - Xiudi Xiao
- Department of Breast Surgery, Jiangsu University Affiliated People’s Hospital, Zhenjiang, China
| | - Xiao-qin Qian
- Department of Ultrasound, Jiangsu University Affiliated People’s Hospital, Zhenjiang, China
| |
Collapse
|
26
|
Li JX, Li XL, Zhu JE, Zhang HL, Yu SY, Xu HX. Ultrasound-guided microwave ablation for symptomatic abdominal wall endometriosis and treatment response evaluation with contrast-enhanced imaging: The first experience. Clin Hemorheol Microcirc 2022; 82:63-73. [PMID: 35662109 DOI: 10.3233/ch-211287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
INTRODUCTION: Abdominal wall endometriosis (AWE) is a relatively uncommon condition associated with diagnostic and therapeutic difficulties among all the extra pelvic endometriosis. The main therapies include surgery and oral contraceptive administration. Percutaneous cryoablation and high intensity focused ultrasound (HIFU) are also proven to be valid alternatives. Microwave ablation (MWA) as one of the thermal ablation methods has not been applied in the treatment of AWE yet. Herein the feasibility of ultrasound (US) –guided MWA for AWE was explored and treatment response evaluation was carried out using contrast-enhanced imaging. METHODS: Three consecutive patients who underwent US-guided MWA for AWE with typical symptoms were included in the retrospective study. US, magnetic resonance imaging (MRI), laboratory tests, and US-guided core-needle biopsy were conducted for pre-treatment assessment and ruling out malignancy. The interventional procedure was carried out under local anesthesia with the microwave system and the output power was 60w. Post-treatment contrast-enhanced ultrasound (CEUS) was performed to evaluate the instant treatment response. The follow-up intervals were 1 month, 6 months, and 12 months after treatment. The clinical symptoms and condition of AWE lesions were recorded in each follow-up. RESULTS: The MWA procedure was completed in all the patients with no blood perfusion inside each lesion by instant CEUS after treatment. The mean ablation time was 687 seconds (s) for a single patient (ranged from 660s to 742s). Clinical symptoms were relieved evidently at the end of the follow-up. The pain according to the visual analogue scale (VAS) decreased from 4–6 before treatment to 0–2 after treatment. Mild to moderate complications included slightly abdominal pain and fat liquefaction occurred. In terms of technical outcomes, the volume of all six lesions reduced in different degrees at the end of follow-up (ranged: 16.6% to 100% ). CONCLUSION: US-guided MWA may be a feasible and promising approach for symptomatic AWE.
Collapse
Affiliation(s)
- Jia-Xin Li
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Xiao-Long Li
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Jing-E Zhu
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Hui-Li Zhang
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Song-Yuan Yu
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Hui-Xiong Xu
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment
- National Clinical Research Center for Interventional Medicine, Shanghai, China
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
27
|
Hoek M, Schultz M, Alummoottil S, Aneck-Hahn N, Mathabe K, Bester J. Ex vivo Vitamin D supplementation improves viscoelastic profiles in prostate cancer patients. Clin Hemorheol Microcirc 2022; 81:221-232. [DOI: 10.3233/ch-211353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: Increased risk of thromboembolic events is associated with prostate cancer, specifically linked to activation of tissue factor. Vitamin D has potential anticoagulant effects by the downregulation of tissue factor expression. OBJECTIVES: To evaluate the effects on clot formation, the morphological and viscoelastic profiles of prostate cancer patients, before and after ex vivo supplementation of Vitamin D was studied. METHODS: Participants were recruited into a metastatic, non-metastatic and reference group. Whole blood samples were treated ex vivo with a dose of 0.5μg/kg Calcitriol. Clot kinetics were assessed using Thromboelastography ®. Morphology of the blood components were studied using scanning electron microscopy (SEM). RESULTS: Results from the Thromboelastography ® and SEM indicated no major differences between the non-metastatic group before and after treatment compared to the reference group. The Thromboelastography ® showed that the metastatic group had an increased viscoelastic profile relating to a hypercoagulable state. Visible changes with regards to platelet activation and fibrin morphology were demonstrated with SEM analysis of the metastatic group. The viscoelastic and morphological properties for the non-metastatic group after treatment improved to be comparable to the reference group. CONCLUSION: Vitamin D supplementation may lead to a more favorable viscoelastic profile, with less dangerous clots forming.
Collapse
Affiliation(s)
- Marinka Hoek
- Department of Urology, University of Pretoria, Pretoria, South Africa
| | - Michelle Schultz
- Department of Physiology, University of Pretoria, Pretoria, South Africa
| | - Sajee Alummoottil
- Department of Physiology, University of Pretoria, Pretoria, South Africa
| | - Natalie Aneck-Hahn
- Department of Urology, University of Pretoria, Pretoria, South Africa
- Environmental Chemical Pollution and Health Research Unit, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Kgomotso Mathabe
- Department of Urology, University of Pretoria, Pretoria, South Africa
| | - Janette Bester
- Department of Physiology, University of Pretoria, Pretoria, South Africa
| |
Collapse
|
28
|
Zhao D, He N, Shao YQ, Yu XL, Chu J, Yang G. The diagnostic value of contrast-enhanced ultrasound for cervical tuberculous lymphadenitis. Clin Hemorheol Microcirc 2022; 81:69-79. [PMID: 35001882 PMCID: PMC9108573 DOI: 10.3233/ch-211355] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE: To investigate the value of contrast-enhanced ultrasound (CEUS) for the diagnosis of cervical tuberculous lymphadenitis (CTL). METHODS: The cohort study included 203 consecutive patients diagnosed with cervical lymph node. Before pathological or laboratory confirmation, all patients underwent CEUS examination, and the imaging findings were analyzed afterward. The diagnostic efficiency of the CEUS imaging findings of CTL was evaluated. RESULTS: Nighty-seven patients of the 203 (47.8%) were pathologically or laboratory confirmed with a CTL diagnosis while the remainder (52.2%) were diagnosed with non-tuberculous lymphadenitis. Regarding the imaging findings of CEUS, it was more common in CTL patients to find a pattern of heterogeneous enhancement inside the lymph nodes relative to non-tuberculous patients [81.44% (79/97) vs 15.09% (16/106), P < 0.01]. The sensitivity of the feature in diagnosis for CTL was 81.44% and the specificity was 84.91%, resepectively. Furthermore, a pattern of peripheral rim-like enhancement had been notable in CTL patients compared with non-tuberculous patients [86.60% (84/97) vs 12.26% (13/106), P < 0.01], associating with a diagnostic sensitivity of 86.60% and a specificity of 87.74%. When it came to the combination of both imaging findings mentioned above, the features were more prominent in CTL patients than compared with non-tuberculous patients [74.23% (72/97) vs 5.66% (6/106), P < 0.01], with a diagnostic sensitivity of 74.23% and a high specificity of 94.34%. Regarding area under curve (AUC) for the ROC analysis, the feature of internal heterogeneous enhancement, peripheral rim-like enhancement, and both features were 0.832, 0.872, and 0.843. CONCLUSIONS: CEUS patterns of heterogeneous enhancement and peripheral rim-like enhancement of lymph nodes are helpful characteristics for the diagnosis of CTL.
Collapse
Affiliation(s)
- Dan Zhao
- Department of Ultrasonography, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou Red Cross Hospital, Tuberculosis Diagnostic and Treatment Center of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Ning He
- Department of Ultrasonography, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou Red Cross Hospital, Tuberculosis Diagnostic and Treatment Center of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Ya-Qin Shao
- Department of Ultrasonography, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou Red Cross Hospital, Tuberculosis Diagnostic and Treatment Center of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Xiu-Lei Yu
- Department of Ultrasonography, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou Red Cross Hospital, Tuberculosis Diagnostic and Treatment Center of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Jie Chu
- Department of Ultrasonography, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou Red Cross Hospital, Tuberculosis Diagnostic and Treatment Center of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Gaoyi Yang
- Department of Ultrasonography, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou Red Cross Hospital, Tuberculosis Diagnostic and Treatment Center of Zhejiang Province, Hangzhou, Zhejiang, China
| |
Collapse
|
29
|
Wang L, Nie F, Dong T, Yin C, Li M, Li Y. Nonhypovascular pancreatic ductal adenocarcinomas: CEUS imaging findings and differentiation from other types of solid pancreatic lesions. Clin Hemorheol Microcirc 2022; 81:163-176. [PMID: 35253738 DOI: 10.3233/ch-221397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVES To observe and assess the diagnostic value of contrast-enhanced ultrasound (CEUS) in patients with iso-/hypervascular solid pancreatic lesions. METHODS 70 pancreatic lesions (all confirmed by surgery or biopsy pathology) that manifested iso-/hyperenhancement on CEUS were retrospectively studied from January 2018 to January 2022, including 24 pancreatic ductal adenocarcinomas (PDAC), 15 mass-forming pancreatitis (MFP), 24 pancreatic neuroendocrine tumors (PNET) (14 hyper-PNETs, 10 iso-PNETs), and 7 solid pseudopapillary tumors of pancreas (SPTP). 65 pancreatic ductal adenocarcinomas (PDAC) that manifested hypoenhancement on CEUS were retrospectively studied from January 2020 to January 2022. CEUS patterns and the clinical and pathologic features were analyzed, and the diagnostic ability of CEUS for iso/hyperenhanced solid pancreatic lesions was assessed. RESULTS Centripetal enhancement, heterogeneous enhancement, early washout, and hypoenhancement in the late phase mostly appeared in iso-/hyper-PDACs (p < 0.05). Heterogeneous enhancement in small lesions (< 3 cm) as the diagnostic criterion for iso-/hyper-PDACs had an accuracy of 74.3% and a specificity of 91.3%. Iso-PNETs more commonly had larger tumor sizes and more often showed heterogeneous enhancement than hyper-PNETs (p = 0.007, p = 0.035, respectively). The characteristics of the combination of isoenhancement, homogeneous enhancement, and synchronous wash-in/out for MFP had a high accuracy of 90%. Capsular enhancement with heterogeneous enhancement inside for SPTP had an accuracy of 97.1%. CONCLUSION CEUS enhancement patterns have potentially great value in the differentiation of iso-/hyperenhanced pancreatic lesions.
Collapse
Affiliation(s)
- Lan Wang
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China. Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Fang Nie
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China. Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Tiantian Dong
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China. Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Ci Yin
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China. Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Ming Li
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China. Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Yuanyuan Li
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China. Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| |
Collapse
|
30
|
Qiu YJ, Zhao GC, Shi SN, Zuo D, Zhang Q, Dong Y, Lou WH, Wang WP. Application of dynamic contrast enhanced ultrasound in distinguishing focal-type autoimmune pancreatitis from pancreatic ductal adenocarcinoma. Clin Hemorheol Microcirc 2022; 81:149-161. [PMID: 35253737 DOI: 10.3233/ch-221390] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To explore the value of dynamic contrast enhanced ultrasound (DCE-US) in preoperative differential diagnosis of focal-type autoimmune pancreatitis (AIP) and pancreatic ductal adenocarcinoma (PDAC). PATIENTS AND METHODS From May 2016 to March 2020, patients with biopsy and histopathologically confirmed focal-type AIP (n = 9) were retrospectively included. All patients received contrast enhanced ultrasound (CEUS) examinations one week before surgery/biopsy. Dynamic analysis was performed by VueBox® software (Bracco, Italy). Eighteen cases of resection and histopathologically proved PDAC lesions were also included as control group. B mode ultrasound (BMUS) features, CEUS enhancement patterns, time intensity curves (TICs) and CEUS quantitative parameters were obtained and compared between AIP and PDAC lesions. RESULTS After injection of ultrasound contrast agents, most focal-type AIP lesions displayed hyper-enhancement (2/9, 22.2%) or iso-enhancement (6/9, 66.7%) during arterial phase of CEUS, while most of PDAC lesions showed hypo-enhancement (88.9%) (P < 0.01). During late phase, most of AIP lesions showed iso-enhancement (8/9, 88.9%), while most of PDAC lesions showed hypo-enhancement (94.4%) (P < 0.001). Compared with PDAC lesions, TICs of AIP lesions showed delayed and higher enhancement. Among all CEUS perfusion parameters, ratio of PE (peak enhancement), WiAUC (wash-in area under the curve), WiR (wash-in rate), WiPI (wash-in perfusion index, WiPI = WiAUC/ rise time), WoAUC (wash-out area under the curve), WiWoAUC (wash-in and wash-out area under the curve) and WoR (wash-out rate) between pancreatic lesion and surrounding normal pancreatic tissue were significantly higher in AIP lesions than PDAC lesions (P < 0.05). CONCLUSION DCE-US with quantitative analysis has the potential to make preoperative differential diagnosis between focal-type AIP and PDAC non-invasively.
Collapse
Affiliation(s)
- Yi-Jie Qiu
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Guo-Chao Zhao
- Department of Pancreas Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Shuai-Nan Shi
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Dan Zuo
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Shanghai Institute of Medical Imaging, Shanghai, China
| | - Qi Zhang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Yi Dong
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Wen-Hui Lou
- Department of Pancreas Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Wen-Ping Wang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
31
|
Zhang G, Liu D. Comparative the clinical value of contrast-enhanced ultrasonography, enhancement CT and MRI for diagnosing of liver lesions. Clin Hemorheol Microcirc 2021; 80:241-251. [PMID: 34958008 DOI: 10.3233/ch-211142] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND To investigate the accuracy of contrast-enhanced ultrasonography, CT-enhancement and MRI in the diagnosis of liver-occupying lesions. METHODS 176 patients with suspected liver lesions in our hospital were retrospectively studied from July 2014 to July 2016. All of the 176 patients were diagnosed by contrast-enhanced ultrasonography, enhanced CT and MRI, and the pathological examination was performed. The results of pathological examination were regarded as the results of the diagnosis. The diagnostic accuracywas then compared among contrast-enhanced ultrasound, enhanced CT and MRI of these patients. RESULTS The results of contrast-enhanced ultrasonography showed that 164 of the 176 patients had liver-occupying lesions, and the accuracy of the diagnosis was 95.35%, which was significantly higher than that of CT enhancement and MRI (80.23% 84.30%). The accuracy of contrast-enhanced ultrasonography, in the diagnosis of primary liver cancer was significantly higher than that of CT enhancement and MRI (P < 0.05), and the difference was significant difference (P < 0.05). CONCLUSIONS The examination of contrast-enhanced ultrasonography is relatively simple, and the patients can get duplicateexamination, so we should choose the contrast-enhanced ultrasonography as the preferred method of diagnosis in liver mass, especially primary liver cancer.
Collapse
Affiliation(s)
- Gang Zhang
- Department of Pediatric Surgery, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Dandan Liu
- Department of Ultrasound Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China
| |
Collapse
|
32
|
Abstract
In multimodal radiologic imaging, contrast-enhanced ultrasound (CEUS) is increasingly used. One of the advantages of CEUS is the possibility of repeated application of contrast media without decreasing renal function or affecting the thyroid gland. Small solid liver lesions can be diagnosed and detected with high accuracy. Moreover, solid lesions in other abdominal organs can also be characterized. Frequent applications for solid lesions in the near field concern thyroid tumors and lymph nodes. For prostate diagnostics, CEUS can be used with an endorectal probe and perfusion imaging. This review explains how the additional (semi-)quantitative perfusion analysis, especially time-intensity curve (TIC) analyses, and wash-in/wash-out kinetics of integrated or external perfusion software programs facilitate new options in dynamic assessment of microvascularization during tumor follow-up care and even minimally invasive tumor therapy.
Collapse
Affiliation(s)
- Ernst-Michael Jung
- Institute of Radiology, Interdisciplinary Department for Ultrasound, University Medical Center, Regensburg, Germany.
- Institut für Röntgendiagnostik/Interdisziplinäres Ultraschallzentrum, Universitätsklinikum Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
| | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Rostock, Germany
| | - Isabel Wiesinger
- Institute of Neuroradiology, Bezirksklinikum Regensburg, Regensburg, Germany
| |
Collapse
|
33
|
Xu W, Lv K, Huang Y, Wen Q, Pan M, Huang P. Features of ultrasound and contrast enhanced ultrasound in superficial desmoid-type fibromatosis: A series of 19 cases. Clin Hemorheol Microcirc 2021; 80:211-218. [PMID: 34511493 DOI: 10.3233/ch-211249] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
This study aimed to describe the characteristics of superficial desmoid fibromatosis (DF) using two-dimensional and contrast-enhanced ultrasonography, intending to improve diagnostic accuracy. We retrospectively analyzed 19 cases of superficial DF confirmed by surgery or core-needle biopsy in our hospital from January 2018 to August 2020. All patients underwent two-dimensional and contrast-enhanced ultrasound (CEUS) examination. Nineteen patients included 15 women and 4 men, with an average age of 33.37±12.13 years old. The mean size of lesions was 4.78±1.99 cm. On ultrasound, all lesions presented as solitary heterogeneous hypoechoic masses; 13 presented with ill-defined margins. Ten lesions (52.63%) presented with fusiform shapes, and 11 lesions (57.89%) presented with the "fascial tail" sign. CEUS suggested the tumors were hyperenhanced, with an enhanced pattern of rapid wash-in and slow wash-out. Four lesions (21.05%) showed an enlarged scope in the CEUS image compared with the grayscale ultrasound image. In conclusion, an ill-defined heterogeneous hyperechoic appearance with fusiform-shaped and "fascial tail" signs on US and heterogeneous hyperenhancement with an enlarged scope on CEUS are valuable clues in the diagnosis and treatment of superficial DF.
Collapse
Affiliation(s)
- Wen Xu
- Department of Ultrasound, Second Affiliated Hospital of Zhejiang University, School of Medicine, Hangzhou, China
| | - Kun Lv
- Department of Ultrasound, Second Affiliated Hospital of Zhejiang University, School of Medicine, Hangzhou, China
| | - Yunling Huang
- Department of Ultrasound, Second Affiliated Hospital of Zhejiang University, School of Medicine, Hangzhou, China
| | - Qing Wen
- Department of Ultrasound, Second Affiliated Hospital of Zhejiang University, School of Medicine, Hangzhou, China
| | - Minqiang Pan
- Department of Ultrasound, Second Affiliated Hospital of Zhejiang University, School of Medicine, Hangzhou, China
| | - Pintong Huang
- Department of Ultrasound, Second Affiliated Hospital of Zhejiang University, School of Medicine, Hangzhou, China
| |
Collapse
|
34
|
Zhao W, Lu R, Yin L, Guo R. The value of superb microvascular imaging (SMI) scoring assignment method in differentiating benign and malignant thyroid nodules by conventional ultrasound. Clin Hemorheol Microcirc 2021; 78:355-363. [PMID: 34366330 DOI: 10.3233/ch-211235] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To explore the application value of SMI scoring assignment method combined with 2017 American College of Radiology (ACR) Thyroid Imaging, Reporting and Data System (TI-RADS) in differentiating benign and malignant thyroid nodules. METHODS According to the 2017 ACR TI-RADS classification, the enrolled nodules were divided into 3 points group, 4 points group, 5 points group, 6 points group and≥7 points group. The nodules were assigned scores according to the echocity of the nodules and the microvessels detected by SMI and their distribution patterns based on ACR TI-RADS. Accompany with the scores increased or decreased after assignment, the thyroid nodules were re-grouped. RESULTS The AUC after the scores assignment is better than before (Z = 3.881, P < 0.001). The specificity, positive predictive value and accuracy after score assigned are better than those of before (Z = 8.323, P < 0.001; Z = 8.619, P < 0.001; Z = 5.345, P < 0.001), there is no statistical difference in sensitivity before and after score assigned (Z = -0.513, P = 0.60), and the negative predictive value before assigned score is better than that of after (Z = -3.826, P < 0.001). CONCLUSION The diagnostic efficacy after scoring was better than that of before.
Collapse
Affiliation(s)
- Wei Zhao
- Department of Ultrasound, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Ruigang Lu
- Department of Ultrasound, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Li Yin
- Department of Ultrasound, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Ruijun Guo
- Department of Ultrasound, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
35
|
Jung EM, Dinkel J, Verloh N, Brandenstein M, Stroszczynski C, Jung F, Rennert J. Wireless point-of-care ultrasound: First experiences with a new generation handheld device. Clin Hemorheol Microcirc 2021; 79:463-474. [PMID: 34151848 PMCID: PMC8764604 DOI: 10.3233/ch-211197] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
AIM: To evaluate the diagnostic reliability of a new generation wireless point-of care ultrasound device for abdominal and thoracic findings. MATERIAL AND METHODS: 40 patients (16 females, 24 males 19 –80 years, on average 56.1 years) were scanned by an experienced examiner using the new wireless Vscan Air device for abdominal and thoracic findings. The probe frequencies were 2–5 MHz (convex probe) and 3–12 MHz for the linear probe. As a reference standard, all patients were also examined using high-end ultrasound (LOGIQ E9/LOGIQ E10). Results were interpreted independently by two examiners in consensus, also with regard to the image quality (0–4, from not assessable = 0, to excellent 4). RESULTS: In all 40 patients (100%) examination with conventional high-end ultrasound and the Vscan Air ultrasound device was feasible. Sensitivity, specificity, positive and negative predictive value for the diagnosis of abdominal and thoracic findings were 63.3%, 100%, 100%, and 40%, respectively. Most main diagnostic findings were detected using the mobile device compared to the high-end ultrasound. Limitations were found regarding characterization and classification of hepatic and renal tumorous lesions. Image quality revealed mostly minor diagnostic limitations for the mobile device, mean 2.9 (SD ± 0.300) and was excellent or with only minor diagnostic limitations for conventional high-end ultrasound, mean 3.25 (SD ± 0.438). CONCLUSION: Due to its easy application and its high diagnostic reliability, point-of-care ultrasound systems of the latest generation represent a valuable imaging method for the primary assessment of abdominal and thoracic findings, especially in patients on intensive care units or in emergency situations.
Collapse
Affiliation(s)
- E M Jung
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| | - J Dinkel
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| | - N Verloh
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| | - M Brandenstein
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| | - C Stroszczynski
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| | - F Jung
- Institute of Biotechnology, Brandenburg University of Technology, Senftenberg, Germany
| | - J Rennert
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| |
Collapse
|