1
|
Paulus J, Pauls J, Radizzi L, Krecke L, Bury T, Goff CL, Laly A, Schwartz C, Forthomme B, Kaux JF, Croisier JL. Knee strength measurement: Can we switch between isokinetic dynamometers? ISOKINET EXERC SCI 2021. [DOI: 10.3233/ies-193193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: Isokinetic evaluation is considered the gold standard in muscle strength measurement due to its sensitivity, intra-dynamometer reproducibility and usefulness in the injury prevention screening and follow up of subjects with musculoskeletal pathologies, neurological disease or after surgical operation. However, can one switch among different isokinetic dynamometers for the purpose of knee muscles evaluation? OBJECTIVES: To comprehensively evaluate the compatibility of the isokinetic short concentric and eccentric strength evaluation protocol and of the fatigability resistance evaluation between three different isokinetic devices. METHODS: Eighteen recreationally active men underwent three isokinetic knee testing sessions on three different isokinetic devices with 7–10 days of rest between each session. Relative (Pearson’s r product-moment correlation coefficient – PCC) and absolute (standard error of measurement – SEM, Cohen effect sizes (d) and probabilistic inferences – MBI) parameters of reproducibility were determined to assess the inter-dynamometer agreement. RESULTS: For the short concentric and eccentric strength evaluation protocol, the extensors in concentric mode and the flexors in eccentric mode can be compared (eventually with transposition formulas provided) between Biodex, Con-Trex and Cybex (almost all PCC ⩾ 0.80). The DCR could be compared between Con-Trex and Cybex and between Biodex and Cybex pairs (eventually with transposition formula provided). For the fatigability resistance evaluation protocol, the total sum can be compared for extensors (eventually with transposition formulas provided) for PM for all dynamometer pairs considered and, in the case of MW, only for Biodex and Con-Trex (PCC ⩾ 0.80). CONCLUSIONS: Only some of the parameters derived either from the short concentric and eccentric strength evaluation protocol or the fatigability resistance evaluation protocol may be interchangeable providing transposition formulas are applied. Otherwise, isokinetic findings are largely system-dependent save some specific instances.
Collapse
Affiliation(s)
- Julien Paulus
- Department of Motricity Sciences and Physical Therapy and Rehabilitation, University of Liege, Liege, Belgium
- Laboratory of Human Motion Analysis, Clinical University of Liege, Liege, Belgium
| | - Jerome Pauls
- Medical Luxembourg Olympic Centre, Clinical Centre of Sport and Orthopaedic, Luxemburg, Duchy of Luxemburg
| | - Laurent Radizzi
- Medical Luxembourg Olympic Centre, Clinical Centre of Sport and Orthopaedic, Luxemburg, Duchy of Luxemburg
| | - Laurent Krecke
- Medical Luxembourg Olympic Centre, Clinical Centre of Sport and Orthopaedic, Luxemburg, Duchy of Luxemburg
| | - Thierry Bury
- Department of Motricity Sciences and Physical Therapy and Rehabilitation, University of Liege, Liege, Belgium
| | - Caroline Le Goff
- Multidisciplinary Medical and Sports Traumatology Service (SPORTS2), CHU, Liege, Belgium
| | - Arnaud Laly
- Training Centre of the Ligue Belge Francophone de Rugby, Liege, Belgium
| | - Cédric Schwartz
- Laboratory of Human Motion Analysis, Clinical University of Liege, Liege, Belgium
| | - Bénédicte Forthomme
- Department of Motricity Sciences and Physical Therapy and Rehabilitation, University of Liege, Liege, Belgium
- Laboratory of Human Motion Analysis, Clinical University of Liege, Liege, Belgium
- Multidisciplinary Medical and Sports Traumatology Service (SPORTS2), CHU, Liege, Belgium
| | - Jean-François Kaux
- Multidisciplinary Medical and Sports Traumatology Service (SPORTS2), CHU, Liege, Belgium
| | - Jean-Louis Croisier
- Department of Motricity Sciences and Physical Therapy and Rehabilitation, University of Liege, Liege, Belgium
- Laboratory of Human Motion Analysis, Clinical University of Liege, Liege, Belgium
- Multidisciplinary Medical and Sports Traumatology Service (SPORTS2), CHU, Liege, Belgium
| |
Collapse
|