1
|
PARK CHUNKYU, KIM JUNGHUN. DEVELOPMENT OF A THREE-DIMENSIONAL-PRINTED HEART MODEL REPLICATING THE ELASTICITY, TEAR RESISTANCE, AND HARDNESS OF PIG HEART USING AGILUS AND TANGO. J MECH MED BIOL 2022. [DOI: 10.1142/s0219519422400073] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
This study proposes a manufacturing method for reproducing some physical properties of the heart by comparing the elasticity, tear resistance, and hardness of a pig heart and three-dimensional printing materials, Agilus and Tango. A Digital Force Gauge was used to analyze elastic modulus and tear resistance, whereas a Shore A hardness meter was used to measure hardness. Agilus and Tango had 10 and 5 times higher elasticity, respectively, 2 and 4 times higher tear resistance, and a higher Shore A hardness than the pig heart. In summary, the pig heart had a more similar elasticity and Shore A hardness than the Tango sample, whereas more tear resistance was similar to the Agilus sample. Therefore, we proposed elasticity and tear resistance equations that can be used to build a heart model and a conversion table for heart fabrication at various thicknesses.
Collapse
Affiliation(s)
- CHUN-KYU PARK
- Department of Biomedical Engineering, Kyungpook National University, Sangyeok-dong, Buk-gu, Daegu, Republic of Korea
| | - JUNGHUN KIM
- Bio-Medical Research Institute, Kyungpook National University Hospital, Sangyeok-dong, Buk-gu, Daegu, Republic of Korea
| |
Collapse
|