Liu J, Wang C, Li Q, Duan X, Zhu X, Wang J, Du X, Lu J, Li K. Free-Breathing, Non-Gated Heart-To-Brain CTA in Acute Ischemic Stroke: A Feasibility Study on Dual-Source CT. Front Neurol 2022; 13:616964. [PMID: 35273552 PMCID: PMC8902348 DOI: 10.3389/fneur.2022.616964] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Accepted: 01/19/2022] [Indexed: 11/20/2022] Open
Abstract
Purpose To validate the feasibility of free-breathing, non-gated, high-pitch heart-to-brain computed tomography arteriography (CTA) in acute ischemic stroke and the capability of non-gated heart-to-brain CTA in showing cardiac anatomy. Materials and Methods The study protocol was approved by the institutional medical ethics review board. Free-breathing, non-gated, high-pitch heart-to-brain CTA was performed on patients with acute ischemic stroke referred for multimodal CT using a third-generation dual-source CT. Patients scheduled for ECG-triggered heart-to-brain CTA served as controls. Quantitative and/or qualitative image quality of the four cardiac chambers, left atrial appendage, interventricular and interatrial septa, carotid arteries, and coronary arteries were evaluated and compared between the two groups. Results Free-breathing, non-gated, high-pitch heart-to-brain CTA was performed on 30 patients with acute ischemic stroke, whereas the control group included 31 cases. There is no significant difference in the image quality of CTAs between the two groups at cardiac chambers and carotid arteries. The image quality of coronary arteries also showed no significant difference between the two groups. The mean dose length products of CTA in the two groups were 129.1 ± 30.5 mGy cm and 121.6 ± 30.3 mGy cm, respectively. Cardiac abnormality can be shown in patients with acute ischemic stroke. Conclusion It is feasible to use free-breathing, non-gated, high-pitch heart-to-brain CTA with dual-source CT in acute ischemic stroke for cardiac etiology screening.
Collapse
Affiliation(s)
- Jiabin Liu
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China.,Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China
| | - Chen Wang
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Qing Li
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Xianggong Duan
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Xiaolian Zhu
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Jiahong Wang
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Xiangying Du
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China.,Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China
| | - Jie Lu
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China.,Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China
| | - Kuncheng Li
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China.,Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China
| |
Collapse
|
2
|
Systolic High-Pitch Coronary CT Angiography for Evaluation of the Coronary Arteries in Heart Transplant Recipients. AJR Am J Roentgenol 2020; 215:828-833. [PMID: 32783558 DOI: 10.2214/ajr.19.22639] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
OBJECTIVE. The purpose of this study was to evaluate the feasibility, image quality, and radiation dose of high-pitch coronary CT angiography (CCTA) in orthotopic heart transplant (OHT) recipients. SUBJECTS AND METHODS. Twenty-two consecutive OHT recipients (16 men, six women; median age, 66.5 years [interquartile range, 51.3-70.3 years]; median heart rate, 91 beats/min [interquartile range, 79.3-97.3 beats/min]) underwent CCTA with a third-generation dual-source CT scanner in high-pitch mode to rule out coronary allograft vasculopathy. Data acquisition was triggered at 30% of the R-R interval. Two independent observers blindly assessed image quality on a per-segment, per-vessel, and per-patient basis using a 4-point scale (4, excellent; 1, not evaluative). Scores 2-4 indicated diagnostic quality. Studies were compared with previously performed retrospective ECG-gated examinations, when available. Interobserver agreement on the image quality was assessed with kappa statistics. Radiation dose was recorded. RESULTS. A total of 322 coronary segments were evaluated. Diagnostic image quality was observed in 97.5% of the segments. Interobserver agreement for image quality assessment was very good on a per-patient (κ = 0.82), per-vessel (κ = 0.83), and per-segment basis (κ = 0.89). The median per-patient image quality score was 4.0 (3.0-4.0) for the entire coronary tree. A comparison of image quality scores between high-pitch and retrospective ECG-gated CCTA examinations showed no significant differences, but the estimated mean radiation dose was significantly lower for the high-pitch mode (median dose-length product, 31.6 mGy × cm [interquartile range, 23.1-38.8 mGy × cm] vs 736.5 mGy × cm [interquartile range, 655.5-845.7 mGy × cm], p < 0.001). CONCLUSION. Performing single-heartbeat high-pitch CCTA during the systolic phase of the cardiac cycle in OHT recipients results in diagnostic image quality in coronary angiograms at very low radiation dose.
Collapse
|
3
|
Monica MP, Merkely B, Szilveszter B, Drobni ZD, Maurovich-Horvat P. Computed Tomographic Angiography for Risk Stratification in Patients with Acute Chest Pain - The Triple Rule-out Concept in the Emergency Department. Curr Med Imaging 2020; 16:98-110. [PMID: 32003310 DOI: 10.2174/1573405614666180604095120] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 06/20/2017] [Accepted: 03/19/2018] [Indexed: 12/26/2022]
Abstract
BACKGROUND Acute chest pain is one of the most common reasons for Emergency Department (ED) visits and hospital admissions. As this could represent the first symptom of a lifethreatening condition, urgent identification of the etiology of chest pain is of utmost importance in emergency settings. Such high-risk conditions that can present with acute chest pain in the ED include Acute Coronary Syndromes (ACS), Pulmonary Embolisms (PE) and Acute Aortic Syndromes (AAS). DISCUSSION The concept of Triple Rule-out Computed Tomographic Angiography (TRO-CTA) for patients presenting with acute chest pain in the ED is based on the use of coronary computed tomographic angiography as a single imaging technique, able to diagnose or exclude three lifethreatening conditions in one single step: ACS, AAS and PE. TRO-CTA protocols have been proved to be efficient in the ED for diagnosis or exclusion of life-threatening conditions and for differentiation between various etiologies of chest pain, and application of the TRO-CTA protocol in the ED for acute chest pain of uncertain etiology has been shown to improve the further clinical evaluation and outcomes of these patients. CONCLUSION This review aims to summarize the main indications and techniques used in TRO protocols in EDs, and the role of TRO-CTA protocols in risk stratification of patients with acute chest pain.
Collapse
Affiliation(s)
- Marton-Popovici Monica
- Department of Internal Medicine and Critical Care, Swedish Medical Center, Edmonds, Washington, United States
| | - Béla Merkely
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Bálint Szilveszter
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Zsófia Dora Drobni
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Pál Maurovich-Horvat
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| |
Collapse
|
4
|
Richards CE, Obaid DR. Low-Dose Radiation Advances in Coronary Computed Tomography Angiography in the Diagnosis of Coronary Artery Disease. Curr Cardiol Rev 2019; 15:304-315. [PMID: 30806322 PMCID: PMC8142354 DOI: 10.2174/1573403x15666190222163737] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 12/24/2018] [Accepted: 12/26/2018] [Indexed: 01/16/2023] Open
Abstract
Background
Coronary computed tomography angiography (CCTA) is now widely used in the diagnosis of coronary artery disease since it is a rapid, minimally invasive test with a diagnostic accuracy comparable to coronary angiography. However, to meet demands for increasing spatial and temporal resolution, higher x-ray radiation doses are required to circumvent the resulting increase in image noise. Exposure to high doses of ionizing radiation with CT imaging is a major health concern due to the potential risk of radiation-associated malignancy. Given its increasing use, a number of dose saving algorithms have been implemented to CCTA to minimize radiation exposure to “as low as reasonably achievable (ALARA)” without compromising diagnostic image quality. Objective
The purpose of this review is to outline the most recent advances and current status of dose saving techniques in CCTA. Method
PubMed, Medline, EMBASE and Scholar databases were searched to identify feasibility studies, clinical trials, and technology guidelines on the technical advances in CT scanner hardware and reconstruction software. Results
Sub-millisievert (mSv) radiation doses have been reported for CCTA due to a combination of strategies such as prospective electrocardiogram-gating, high-pitch helical acquisition, tube current modulation, tube voltage reduction, heart rate reduction, and the most recent novel adaptive iterative reconstruction algorithms. Conclusion
Advances in radiation dose reduction without loss of image quality justify the use of CCTA as a non-invasive alternative to coronary catheterization in the diagnosis of coronary artery disease.
Collapse
Affiliation(s)
- Caryl E Richards
- Department of Cardiology, Morriston Hospital, Heol Maes Eglwys, Morriston, Swansea, SA6 6NL, United Kingdom
| | - Daniel R Obaid
- Department of Cardiology, Morriston Hospital, Heol Maes Eglwys, Morriston, Swansea, SA6 6NL, United Kingdom.,Swansea University Medical School, Swansea University, Grove Building, Singleton Park, Sketty, Swansea SA2 8PP, United Kingdom
| |
Collapse
|
5
|
Image quality and diagnostic value of ultra low-voltage, ultra low-contrast coronary CT angiography. Eur Radiol 2019; 29:3678-3685. [DOI: 10.1007/s00330-019-06111-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Revised: 01/28/2019] [Accepted: 02/13/2019] [Indexed: 10/27/2022]
|
6
|
Forte E, Monti S, Parente CA, Beyer L, De Rosa R, Infante T, Cavaliere C, Cademartiri F, Salvatore M, Stroszczynski C, Tedeschi C. Image Quality and Dose Reduction by Dual Source Computed Tomography Coronary Angiography: Protocol Comparison. Dose Response 2018; 16:1559325818805838. [PMID: 30349426 PMCID: PMC6194939 DOI: 10.1177/1559325818805838] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 09/06/2018] [Accepted: 09/18/2018] [Indexed: 01/18/2023] Open
Abstract
Purpose: To compare image quality and radiation dose among different protocols in patients who underwent a 128-slice dual source computed tomography coronary angiography (DSCT-CTCA). Methods: Ninety patients were retrospectively grouped according to heart rate (HR): 26 patients (group A) with stable HR ≤60 bpm were acquired using high pitch spiral mode (FLASH); 48 patients (group B) with irregular HR ≤60 bpm or stable HR between 60 and 70 bpm using step and shoot mode; and 16 patients (group C) with irregular HR >60 bpm or stable HR ≥70 bpm by retrospective electrocardiogram pulsing acquisition. Signal to noise ratio (SNR) and contrast to noise ratio (CNR) were measured for the main vascular structures. Moreover, the dose-length product and the effective dose were assessed. Results: Both SNR and CNR were higher in group A compared to group C (18.27 ± 0.32 vs 11.22 ± 0.50 and 16.75 ± 0.32 vs 10.17 ± 0.50; P = .001). The effective dose was lower in groups A and B (2.09 ± 1.27 mSv and 4.60 ± 2.78 mSv, respectively) compared to group C (9.61 ± 5.95 mSv) P < .0001. Conclusion: The correct selection of a low-dose, HR-matched CTCA scan protocol with a DSCT scanner provides substantial reduction of radiation exposure and better SNR and CNR.
Collapse
Affiliation(s)
| | | | | | - Lukas Beyer
- Department of Radiology, Universitätsklinikum Regensburg, Regensburg, Germany
| | | | | | | | | | | | | | - Carlo Tedeschi
- Department of Radiology, Universitätsklinikum Regensburg, Regensburg, Germany.,P.S.I. Napoli Est, ASL Napoli 1 Centro, Naples, Italy
| |
Collapse
|
7
|
Goo HW. Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering. Korean J Radiol 2018; 19:1031-1041. [PMID: 30386135 PMCID: PMC6201980 DOI: 10.3348/kjr.2018.19.6.1031] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 05/08/2018] [Indexed: 12/27/2022] Open
Abstract
Objective To compare image quality and radiation dose of high-pitch dual-source spiral cardiothoracic computed tomography (CT) between non-electrocardiography (ECG)-synchronized and prospectively ECG-triggered data acquisitions in young children with congenital heart disease. Materials and Methods Eighty-six children (≤ 3 years) with congenital heart disease who underwent high-pitch dual-source spiral cardiothoracic CT were included in this retrospective study. They were divided into two groups (n = 43 for each; group 1 with non-ECG-synchronization and group 2 with prospective ECG triggering). Patient-related parameters, radiation dose, and image quality were compared between the two groups. Results There were no significant differences in patient-related parameters including age, cross-sectional area, body density, and water-equivalent area between the two groups (p > 0.05). Regarding radiation dose parameters, only volume CT dose index values were significantly different between group 1 (1.13 ± 0.09 mGy) and group 2 (1.07 ± 0.12 mGy, p < 0.02). Among image quality parameters, significantly higher image noise (3.8 ± 0.7 Hounsfield units [HU] vs. 3.3 ± 0.6 HU, p < 0.001), significantly lower signal-to-noise ratio (105.0 ± 28.9 vs. 134.1 ± 44.4, p = 0.001) and contrast-to-noise ratio (84.5 ± 27.2 vs. 110.1 ± 43.2, p = 0.002), and significantly less diaphragm motion artifacts (3.8 ± 0.5 vs. 3.7 ± 0.4, p < 0.04) were found in group 1 compared with group 2. Image quality grades of cardiac structures, coronary arteries, ascending aorta, pulmonary trunk, lung markings, and chest wall showed no significant difference between groups (p > 0.05). Conclusion In high-pitch dual-source spiral pediatric cardiothoracic CT, additional ECG triggering does not substantially reduce motion artifacts in young children with congenital heart disease.
Collapse
Affiliation(s)
- Hyun Woo Goo
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| |
Collapse
|
8
|
High-Pitch Coronary Computed Tomographic Angiography Using the Third-Generation Dual-Source Computed Tomography. J Comput Assist Tomogr 2018; 42:248-255. [DOI: 10.1097/rct.0000000000000678] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
9
|
Baumann S, Kryeziu P, Rutsch M, Lossnitzer D. Coronary Computed Tomography Angiography. Interv Cardiol 2017. [DOI: 10.5772/67800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
|
10
|
Hachulla AL, Ronot M, Noble S, Becker CD, Montet X, Vallée JP. ECG-triggered high-pitch CT for simultaneous assessment of the aorta and coronary arteries. J Cardiovasc Comput Tomogr 2016; 10:407-13. [DOI: 10.1016/j.jcct.2016.07.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Accepted: 07/10/2016] [Indexed: 12/21/2022]
|
11
|
Utility of dual source CT with ECG-triggered high-pitch spiral acquisition (Flash Spiral Cardio mode) to evaluate morphological features of ventricles in children with complex congenital heart defects. Jpn J Radiol 2016; 34:284-91. [DOI: 10.1007/s11604-016-0522-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2015] [Accepted: 01/17/2016] [Indexed: 10/22/2022]
|
12
|
Koplay M, Celik M, Avcı A, Erdogan H, Demir K, Sivri M, Nayman A. Comparison Between Prospectively Electrocardiogram-Gated High-Pitch Mode and Retrospectively Electrocardiogram-Gated Mode for Dual-Source CT Coronary Angiography. Pol J Radiol 2015; 80:561-8. [PMID: 26767072 PMCID: PMC4699622 DOI: 10.12659/pjr.895232] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2015] [Accepted: 08/04/2015] [Indexed: 01/01/2023] Open
Abstract
Background We aimed to report the image quality, relationship between heart rate and image quality, amount of contrast agent given to the patients and radiation doses in coronary CT angiography (CTA) obtained by using high-pitch prospectively ECG-gated “Flash Spiral” technique (method A) or retrospectively ECG-gated technique (method B) using 128×2-slice dual-source CT. Material/Methods A total of 110 patients who were evaluated with method A and method B technique with a 128×2-detector dual-source CT device were included in the study. Patients were divided into three groups based on their heart rates during the procedure, and a relationship between heart rate and image quality were evaluated. The relationship between heart rate, gender and radiation dose received by the patients was compared. Results A total of 1760 segments were evaluated in terms of image quality. Comparison of the relationship between heart rate and image quality revealed a significant difference between heart rate <60 beats/min group and >75 beats/min group whereas <60 beats/min and 60–75 beats/min groups did not differ significantly. The average effective dose for coronary CTA was calculated as 1.11 mSv (0.47–2.01 mSv) for method A and 8.22 mSv (2.19–12.88 mSv) for method B. Conclusions Method A provided high quality images with doses as low as <1 mSv in selected patients who have low heart rates with a high negative predictive value to rule out coronary artery disease. Although method B increases the amount of effective dose, it provides high diagnostic quality images for patients who have a high heart rate and arrhythmia which makes it is difficult to obtain images.
Collapse
Affiliation(s)
- Mustafa Koplay
- Department of Radiology, Medical Faculty of Selcuk University, Konya, Turkey
| | - Mahmut Celik
- Department of Radiology, Medical Faculty of Selcuk University, Konya, Turkey
| | - Ahmet Avcı
- Department of Cardiology, Medical Faculty of Selcuk University, Konya, Turkey
| | - Hasan Erdogan
- Department of Radiology, Medical Faculty of Selcuk University, Konya, Turkey
| | - Kenan Demir
- Department of Cardiology, Medical Faculty of Selcuk University, Konya, Turkey
| | - Mesut Sivri
- Department of Radiology, Medical Faculty of Selcuk University, Konya, Turkey
| | - Alaaddin Nayman
- Department of Radiology, Medical Faculty of Selcuk University, Konya, Turkey
| |
Collapse
|
13
|
Radiation dose and diagnostic accuracy of high-pitch dual-source coronary angiography in the evaluation of coronary artery stenoses. Diagn Interv Imaging 2015; 97:461-9. [PMID: 26612669 DOI: 10.1016/j.diii.2015.10.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2015] [Revised: 10/06/2015] [Accepted: 10/19/2015] [Indexed: 11/23/2022]
Abstract
PURPOSE "Flash Spiral" imaging is a new prospective ECG-triggered spiral scan mode that uses a very high-pitch for coronary computed tomography angiography (CTA). This enables complete image acquisition within one cardiac cycle with a very low radiation exposure. The aim of this study was to investigate the diagnostic accuracy, image quality, and effective radiation dose of prospectively ECG-triggered high-pitch spiral method (Flash spiral mode) of coronary CTA using dual-source technology for the evaluation of coronary artery stenoses. MATERIAL AND METHODS The study included 186 consecutive patients (115men, 71women; mean age: 53.37 years) who underwent coronary CTA. Coronary CTA was performed with a 128×2-slice dual-source CT (Somatom Definition Flash, Siemens, Germany) using a prospectively ECG-triggered high-pitch spiral mode. Patients were divided into three groups according to heart rate (≤65bpm, 66-75bpm, ≥76bpm) and body mass index (BMI) (20-24kg/m(2), 25-29kg/m(2), 30-34kg/m(2)) values. The correlation between heart rates, image quality and BMI values are investigated. A four-point scale (1=excellent, 4=poor/non-diagnostic) was used to rank the comparative image quality. Effective radiation doses were calculated. Also the correlation between radiation dose, sex and BMI values were investigated. In addition, diagnostic accuracy of CTA for detection of significant (≥50%) coronary artery stenoses was compared with invasive coronary angiography findings of 612vessel segments in 38patients. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy rate were calculated. RESULTS A total of 2976coronary artery segments were present. Of all coronary artery segments, 2381 (80%) had an image quality score of 1, and 1.5% segments were rated as "poor/non-diagnostic". When the correlation between heart rate and image quality is investigated, there was a significant difference between ≤65bpm and ≥76bpm groups. However, there was no significant difference between ≤65bpm and 66-75bpm groups. The mean effective dose was found as 1.3mSv (min: 0.5, max: 2.4mSv). The correlation between effective radiation dose and BMI was moderate. However, the correlation between gender and radiation dose was significant. Sensitivity, specificity, negative predictive value and accuracy of coronary CTA on a per-vessel segment were 90.1%, 97.4%, 98.6%, and 96.5%, respectively. CONCLUSIONS Prospectively ECG-triggered high-pitch spiral mode coronary CTA provides high image quality and diagnostic accuracy, with very low radiation dose for evaluation and exclusion of coronary artery stenoses.
Collapse
|
14
|
Zhang LJ, Wang Y, Schoepf UJ, Meinel FG, Bayer RR, Qi L, Cao J, Zhou CS, Zhao YE, Li X, Gong JB, Jin Z, Lu GM. Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography. Eur Radiol 2015; 26:797-806. [PMID: 26382844 DOI: 10.1007/s00330-015-3868-z] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 05/05/2015] [Accepted: 05/29/2015] [Indexed: 12/14/2022]
Abstract
PURPOSE To investigate image quality, radiation dose, and diagnostic performance of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) at 70 kVp compared to invasive coronary angiography (ICA) as reference standard. MATERIALS AND METHODS Forty-three patients underwent prospectively ECG-triggered high-pitch CCTA at 70 kVp using 30 cc (11 g iodine) contrast medium and ICA. Subjective and objective image quality was evaluated for each CCTA study. CCTA performance for diagnosing ≥50% stenosis was assessed. Results were stratified according to heart rate (HR), body mass index (BMI), Agatston score, and image quality. RESULTS At CCTA, 94.3% (500/530) of coronary segments were of diagnostic quality. Using ICA as reference standard, sensitivity and accuracy were 100% and 93.0% on a per-patient basis. Per-vessel and per-segment performances were 92.2% and 89.5%; 79.5% and 88.3%, respectively. No differences were found in diagnostic accuracy between different HR, BMI, and calcification subgroups (all P > 0.05) on a per-patient basis. However, low image quality reduced diagnostic accuracy on a per-patient, per-vessel and per-segment basis (all P < 0.05). The mean effective radiation dose was 0.2 ± 0.0 mSv. CONCLUSION Our presented protocol results in an effective radiation dose of 0.2 mSv and high diagnostic accuracy for stenosis detection in a selected, non-obese population. KEY POINTS Prospectively ECG-triggered high-pitch CCTA at 70 kVp is feasible. This protocol has a high diagnostic accuracy for stenosis detection. The mean effective radiation dose was 0.2 ± 0.0 mSv. Only 30 cc of contrast material is used in this protocol. Low image quality reduced diagnostic accuracy of CCTA.
Collapse
Affiliation(s)
- Long Jiang Zhang
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China.
| | - Yining Wang
- Department of Radiology, Peking Union Medical College Hospital, Beijing, China
| | - U Joseph Schoepf
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China.,Division of Cardiovascular Imaging, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr, Charleston, SC, 29425, USA
| | - Felix G Meinel
- Division of Cardiovascular Imaging, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr, Charleston, SC, 29425, USA.,Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - Richard R Bayer
- Division of Cardiovascular Imaging, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr, Charleston, SC, 29425, USA
| | - Li Qi
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - Jian Cao
- Department of Radiology, Peking Union Medical College Hospital, Beijing, China
| | - Chang Sheng Zhou
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - Yan E Zhao
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - Xie Li
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - Jian Bin Gong
- Department of Cardiology, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - Zhengyu Jin
- Department of Radiology, Peking Union Medical College Hospital, Beijing, China.
| | - Guang Ming Lu
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China.
| |
Collapse
|
15
|
|
16
|
The Impact of Different Levels of Adaptive Iterative Dose Reduction 3D on Image Quality of 320-Row Coronary CT Angiography: A Clinical Trial. PLoS One 2015; 10:e0125943. [PMID: 25945924 PMCID: PMC4422621 DOI: 10.1371/journal.pone.0125943] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2015] [Accepted: 03/22/2015] [Indexed: 11/19/2022] Open
Abstract
Purpose The aim of this study was the systematic image quality evaluation of coronary CT angiography (CTA), reconstructed with the 3 different levels of adaptive iterative dose reduction (AIDR 3D) and compared to filtered back projection (FBP) with quantum denoising software (QDS). Methods Standard-dose CTA raw data of 30 patients with mean radiation dose of 3.2 ± 2.6 mSv were reconstructed using AIDR 3D mild, standard, strong and compared to FBP/QDS. Objective image quality comparison (signal, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), contour sharpness) was performed using 21 measurement points per patient, including measurements in each coronary artery from proximal to distal. Results Objective image quality parameters improved with increasing levels of AIDR 3D. Noise was lowest in AIDR 3D strong (p≤0.001 at 20/21 measurement points; compared with FBP/QDS). Signal and contour sharpness analysis showed no significant difference between the reconstruction algorithms for most measurement points. Best coronary SNR and CNR were achieved with AIDR 3D strong. No loss of SNR or CNR in distal segments was seen with AIDR 3D as compared to FBP. Conclusions On standard-dose coronary CTA images, AIDR 3D strong showed higher objective image quality than FBP/QDS without reducing contour sharpness. Trial Registration Clinicaltrials.gov NCT00967876
Collapse
|
17
|
Evaluation of high-pitch dual-source CT angiography for evaluation of coronary and carotid-cerebrovascular arteries. Eur J Radiol 2015; 84:398-406. [DOI: 10.1016/j.ejrad.2014.11.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2013] [Revised: 10/07/2014] [Accepted: 11/11/2014] [Indexed: 11/18/2022]
|
18
|
High-pitch prospective ECG-triggered helical coronary computed tomography angiography in clinical practice: image quality and radiation dose. Int J Cardiovasc Imaging 2014; 31:125-33. [DOI: 10.1007/s10554-014-0515-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2014] [Accepted: 08/06/2014] [Indexed: 10/24/2022]
|
19
|
Farshad-Amacker NA, Alkadhi H, Leschka S, Frauenfelder T. Effect of high-pitch dual-source CT to compensate motion artifacts: a phantom study. Acad Radiol 2013; 20:1234-9. [PMID: 24029055 DOI: 10.1016/j.acra.2013.07.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2013] [Revised: 06/24/2013] [Accepted: 07/02/2013] [Indexed: 11/19/2022]
Abstract
RATIONALE AND OBJECTIVES To evaluate the potential of high-pitch, dual-source computed tomography (DSCT) for compensation of motion artifacts. MATERIALS AND METHODS Motion artifacts were created using a moving chest/cardiac phantom with integrated stents at different velocities (from 0 to 4-6 cm/s) parallel (z direction), transverse (x direction), and diagonal (x and z direction combined) to the scanning direction using standard-pitch (SP) (pitch = 1) and high-pitch (HP) (pitch = 3.2) 128-detector DSCT (Siemens, Healthcare, Forchheim, Germany). The scanning parameters were (SP/HP): tube voltage, 120 kV/120 kV; effective tube current time product, 300 mAs/500 mAs; and a pitch of 1/3.2. Motion artifacts were analyzed in terms of subjective image quality and object distortion. Image quality was rated by two blinded, independent observers using a 4-point scoring system (1, excellent; 2, good with minor object distortion or blurring; 3, diagnostically partially not acceptable; and 4, diagnostically not acceptable image quality). Object distortion was assessed by the measured changes of the object's outer diameter (x) and length (z) and a corresponding calculated distortion vector (d) (d = √(x(2) + z(2))). RESULTS The interobserver agreement was excellent (k = 0.91). Image quality using SP was diagnostically not acceptable with any motion in x direction (scores 3 and 4), in contrast to HP DSCT where it remained diagnostic up to 2 cm/s (scores 1 and 2). For motion in the z direction only, image quality remained diagnostic for SP and HP DSCT (scores 1 and 2). Changes of the object's diameter (x), length (z), and distortion vectors (d) were significantly greater with SP (overall: x = 1.9 cm ± 1.7 cm, z = 0.6 cm ± 0.8 cm, and d = 1.4 cm ± 1.5 cm) compared to HP DSCT (overall: x = 0.1 cm ± 0.1 cm, z = 0.0 cm ± 0.1 cm, and d = 0.1 cm ± 0.1 cm; each P < .05). CONCLUSION High-pitch DSCT significantly decreases motion artifacts in various directions and improves image quality.
Collapse
Affiliation(s)
- Nadja A Farshad-Amacker
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 101, 8091 Zurich, Switzerland.
| | | | | | | |
Collapse
|