Zhang N, Lan C, Du Z, Lin G, Zhong Y, Fei J, Liu K, Ji J, Lu C. Using Computed Tomography Coronary Angiography to Differentiate Atypical Cardiac Myxoma From Thrombus. J Comput Assist Tomogr 2025:00004728-990000000-00427. [PMID: 40008956 DOI: 10.1097/rct.0000000000001708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Accepted: 10/29/2024] [Indexed: 02/27/2025]
Abstract
OBJECTIVE Atypical cardiac myxoma usually presents as an isolated mass attached to the atrial septum on imaging, with no movement and a wider attachment base. It is difficult to distinguish it from cardiac thrombus through conventional echocardiography or computed tomography (CT). The purpose of this study is to evaluate the value of CT coronary angiography imaging features in distinguishing atypical cardiac myxoma from cardiac thrombus. MATERIALS AND METHODS This retrospective study included patients with atypical myxoma of the heart confirmed by histopathology (n = 18) and with thrombus disappearance after anticoagulation treatment (n = 23). All patients underwent a third-generation dual-source CT coronary angiography. We compared the clinical features and CT coronary angiography image characteristics of the 2 groups and used maximum-intensity projection and multiplanar reconstruction to show neovascularization of atypical cardiac myxoma. RESULTS There are significant differences in the origin, surface, and enhancement patterns between atypical cardiac myxoma and thrombus (P < 0.05, respectively). Specifically, supplied vessels were observed in the atypical cardiac myxoma group, while no neovascularization was detected in the thrombus group (83.33% vs. 0%, P < 0.001). CONCLUSIONS Noninvasive CT coronary angiography can help distinguish atypical cardiac myxoma and cardiac thrombus through imaging features, especially by detecting the supplying vessels. However, supplementary examinations such as cardiac magnetic resonance imaging are still needed to identify different cardiac tumors.
Collapse
Affiliation(s)
- Nannan Zhang
- Key Laboratory of Imaging Diagnosis and Minimally Invasive Intervention Research, Imaging Diagnosis and Interventional Minimally Invasive Institute, Department of Radiology, The Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, Zhengjiang, China
- Center for Rehabilitation Medicine, Department of Pain Management, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Chuanqiang Lan
- Key Laboratory of Imaging Diagnosis and Minimally Invasive Intervention Research, Imaging Diagnosis and Interventional Minimally Invasive Institute, Department of Radiology, The Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, Zhengjiang, China
| | - Zeliu Du
- Key Laboratory of Imaging Diagnosis and Minimally Invasive Intervention Research, Imaging Diagnosis and Interventional Minimally Invasive Institute, Department of Radiology, The Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, Zhengjiang, China
| | - Guihan Lin
- Key Laboratory of Imaging Diagnosis and Minimally Invasive Intervention Research, Imaging Diagnosis and Interventional Minimally Invasive Institute, Department of Radiology, The Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, Zhengjiang, China
| | - Yi Zhong
- Key Laboratory of Imaging Diagnosis and Minimally Invasive Intervention Research, Imaging Diagnosis and Interventional Minimally Invasive Institute, Department of Radiology, The Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, Zhengjiang, China
| | - Jingle Fei
- Key Laboratory of Imaging Diagnosis and Minimally Invasive Intervention Research, Imaging Diagnosis and Interventional Minimally Invasive Institute, Department of Radiology, The Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, Zhengjiang, China
| | - Kan Liu
- Division of Cardiology and Heart and Vascular Center, Washington University in St Louis, School of Medicine, Saint Louis, MO
| | - Jiansong Ji
- Key Laboratory of Imaging Diagnosis and Minimally Invasive Intervention Research, Imaging Diagnosis and Interventional Minimally Invasive Institute, Department of Radiology, The Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, Zhengjiang, China
| | - Chenying Lu
- Key Laboratory of Imaging Diagnosis and Minimally Invasive Intervention Research, Imaging Diagnosis and Interventional Minimally Invasive Institute, Department of Radiology, The Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, Zhengjiang, China
| |
Collapse
|
2
|
Hu L, Ouyang R, Li J, Zhang G, Li J, Guo C, Wang Q, Zhong Y. From age-specific to size-specific dose protocol for paediatric head computed tomography: a simple practical strategy for necessity assessment and parameter setting. RADIATION PROTECTION DOSIMETRY 2024; 200:1981-1989. [PMID: 39422532 DOI: 10.1093/rpd/ncae202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 07/23/2024] [Accepted: 10/03/2024] [Indexed: 10/19/2024]
Abstract
This study proposes a practical approach to assessing the need for and determining the transitioning parameters from age-specific to size-specific dose protocols in paediatric head computed tomography examinations. It was designed to begin with the two different age-specific protocols currently applied on paediatric patients of 1 y ≤ age ≤ 6 y (21.34 mGy) and those of age >6 y (34.73 mGy). One characteristic size (HDthreshold) was found by measuring anteroposterior head diameter on historical topograms and used with age to set 135 cases into four groups for investigation (A, ≤6y, ≤HDthreshold; B, ≤6y, >HDthreshold; C, >6y, ≤HDthreshold; and D, >6 y, >HDthreshold). The image quality was compared in both subjective and objective manners. Results suggest patients in Group C may have received a potential overdose (38%), while the exposure setting for Group D may replace that for B. The proposed strategy was sufficient to assess the necessity and determine the transitioning parameters from age- to size-specific dose protocols.
Collapse
Affiliation(s)
- Liwei Hu
- Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, 1678 Dongfang Road, Shanghai 200127, China
- Pediatric Imaging Advanced Technology Research Center, 1678 Dongfang Road, Shanghai 200127, China
| | - Rongzhen Ouyang
- Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, 1678 Dongfang Road, Shanghai 200127, China
| | - Jing Li
- Pediatric Imaging Advanced Technology Research Center, 1678 Dongfang Road, Shanghai 200127, China
- United Imaging Healthcare, 2258 Chengbei Road, Shanghai 201815, China
| | - Guozhi Zhang
- Pediatric Imaging Advanced Technology Research Center, 1678 Dongfang Road, Shanghai 200127, China
- United Imaging Healthcare, 2258 Chengbei Road, Shanghai 201815, China
| | - Jiong Li
- Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, 1678 Dongfang Road, Shanghai 200127, China
| | - Chen Guo
- Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, 1678 Dongfang Road, Shanghai 200127, China
| | - Qian Wang
- Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, 1678 Dongfang Road, Shanghai 200127, China
| | - Yumin Zhong
- Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, 1678 Dongfang Road, Shanghai 200127, China
- Pediatric Imaging Advanced Technology Research Center, 1678 Dongfang Road, Shanghai 200127, China
| |
Collapse
|
3
|
Wang XP, Zhu XM, Zhu YS, Liu WY, Yang XH, Huang WW, Xu Y, Tang LJ. Automatic tube potential selection with tube current modulation in coronary CT angiography: Can it achieve consistent image quality among various individuals? Exp Ther Med 2018; 16:253-259. [PMID: 29896246 PMCID: PMC5995055 DOI: 10.3892/etm.2018.6158] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Accepted: 04/06/2018] [Indexed: 11/06/2022] Open
Abstract
The present study included a total of 111 consecutive patients who had undergone coronary computed tomography (CT) angiography, using a first-generation dual-source CT with automatic tube potential selection and tube current modulation. Body weight (BW) and body mass index (BMI) were recorded prior to CT examinations. Image noise and attenuation of the proximal ascending aorta (AA) and descending aorta (DA) at the middle level of the left ventricle were measured. Correlations between BW, BMI and objective image quality were evaluated using linear regression. In addition, two subgroups based on BMI (BMI ≤25 and >25 kg/m2) were analyzed. Subjective image quality, image noise, the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were all compared between those. The image noise of the AA increased with the BW and BMI (BW: r=0.453, P<0.001; BMI: r=0.545, P<0.001). The CNR and SNR of the AA were inversely correlated with BW and BMI, respectively. The image noise of the DA and the CNR and SNR of the DA exhibited a similar association to those with the BW or BMI. The BMI >25 kg/m2 group had a significant increase in image noise (33.1±6.9 vs. 27.8±4.0 HU, P<0.05) and a significant reduction in CNR and SNR, when compared with those in the BMI ≤25 kg/m2 group (CNR: 18.9±4.3 vs. 16.1±3.7, P<0.05; SNR: 16.0±3.8 vs. 13.6±3.2, P<0.05). Patients with a BMI of ≤25 kg/m2 had more coronary artery segments scored as excellent, compared with patients with a BMI of >25 kg/m2 (P=0.02). In conclusion, this method is not able to achieve a consistent objective image quality across the entire patient population. The impact of BW and BMI on objective image quality was not completely eliminated. BMI-based adjustment of the tube potential may achieve a more consistent image quality compared to automatic tube potential selection, particularly in patients with a larger body habitus.
Collapse
Affiliation(s)
- Xiao-Ping Wang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Xiao-Mei Zhu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Yin-Su Zhu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Wang-Yan Liu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Xiao-Han Yang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Wei-Wei Huang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Yi Xu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Li-Jun Tang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| |
Collapse
|
4
|
Tan SK, Yeong CH, Raja Aman RRA, Ng KH, Abdul Aziz YF, Chee KH, Sun Z. Low tube voltage prospectively ECG-triggered coronary CT angiography: a systematic review of image quality and radiation dose. Br J Radiol 2018; 91:20170874. [PMID: 29493261 DOI: 10.1259/bjr.20170874] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively electrocardiography (ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) to compare the achievable dose reduction and image quality and (3) to propose appropriate scanning techniques and CM administration methods. METHODS A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods. RESULTS The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp. CONCLUSION This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.
Collapse
Affiliation(s)
- Sock Keow Tan
- 1 Department of Biomedical Imaging, Faculty of Medicine, University of Malaya , Kuala Lumpur , Malaysia
| | - Chai Hong Yeong
- 1 Department of Biomedical Imaging, Faculty of Medicine, University of Malaya , Kuala Lumpur , Malaysia
| | | | - Kwan Hoong Ng
- 1 Department of Biomedical Imaging, Faculty of Medicine, University of Malaya , Kuala Lumpur , Malaysia
| | - Yang Faridah Abdul Aziz
- 1 Department of Biomedical Imaging, Faculty of Medicine, University of Malaya , Kuala Lumpur , Malaysia
| | - Kok Han Chee
- 1 Department of Biomedical Imaging, Faculty of Medicine, University of Malaya , Kuala Lumpur , Malaysia.,2 Department of Medicine, Faculty of Medicine, University of Malaya , Kuala Lumpur , Malaysia
| | - Zhonghua Sun
- 3 Department of Medical Radiation Sciences, Curtin University , Perth, WA , Australia
| |
Collapse
|
5
|
Nazli SB, Aghamiri SMR, Gholizadeh Sendani N, Shams Akhtari A. EVALUATION OF RADIATION ABSORBED DOSE AND IMAGE QUALITY IN DIFFERENT RETROSPECTIVE-ECG GATING ACQUISITION METHODS OF CARDIAC CT ANGIOGRAPHY. RADIATION PROTECTION DOSIMETRY 2018; 178:304-309. [PMID: 28981808 DOI: 10.1093/rpd/ncx111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 07/28/2017] [Indexed: 06/07/2023]
Abstract
Cardiac computed tomography angiography (CCTA) studies have risen concern of radiobiological effects over the patients. Therefore, estimating radiation doses absorbed during CCTA is important. In this study, we compared radiation dose and image quality by using three different retrospective electrocardiography (ECG) protocols. A total of 123 patients undergoing CCTA were divided in three different groups. We used full-dose modulation (CareDose4D) technique in group (1); fixed tube current 200 mAs for group (2); and in group (3), chest circumference was used to adapt tube current (180-200 mAs) and tube potential (100-120 kVp). For groups (1) and (2), tube potential adapted depends on body mass index (BMI) in which it was 100 kVp for BMI < 27 kg/m2, and 120 kVp for BMI ≥ 27 kg/m2. Quantitive assessment of image quality was calculated by measuring signal intensity (SI) and image noise (IN) in the proximal segments of aorta root on left and right coronary arteries. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were also calculated by using SI and IN. Two experienced radiologists using a 4-point scale assessed the subjective image quality. Our results show that in group (1), the mean effective dose was 4.46 mSv (range: 1.75-8.6 mSv) and for group (2), the mean effective radiation dose was 5.07 mSv (range: 2.57-9.74 mSv) and in group (3), the mean effective dose was 5.85 mSv (range: 3.36-12.17 mSv). Group (1) representing 12% and 23% decrease in radiation dose comparing by groups (2) and (3). In multivariate analysis, adjusting for BMI, radiation dose for patients with BMI < 27 kg/m2 was significantly different; 2.53 mSv for group (1) compared to 3.54 mSv in group (2) and 5.207 in group (3) (p < 0.0001). In addition, lowering tube potential from 120 to 100 kVp in 200 mAs fixed tube current, represents 27% decrease in radiation dose. The quantitative image quality (IN, SI, SNR and CNR) was not statistically significant among the groups. To sum up, Retrospective-ECG gating may reduce radiation dose by using automatic tube current modulation and 100kVp tube potential with preservation of image quality in patient's whose BMI < 27 kg/m2.
Collapse
Affiliation(s)
| | | | | | - Amin Shams Akhtari
- Department of Emergency Medicine, Faculty of Medical Science, Shahid Beheshti Medical University, Tehran, Iran
| |
Collapse
|
6
|
Feng R, Tong J, Liu X, Zhao Y, Zhang L. High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium. Korean J Radiol 2017; 18:763-772. [PMID: 28860894 PMCID: PMC5552460 DOI: 10.3348/kjr.2017.18.5.763] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2016] [Accepted: 02/22/2017] [Indexed: 11/15/2022] Open
Abstract
Objective To evaluate the feasibility and image quality (IQ) of prospectively high-pitch coronary CT angiography (CCTA) with low contrast medium injection rate at 70 kVp. Materials and Methods One hundred and four patients with suspected coronary artery disease (body mass index < 26 kg/m2, sinus rhythm and heart rate < 70 beats/min) were prospectively enrolled and randomly divided into two groups. In group A and group B, 28 mL and 40 mL of 370 mgI/mL iodinated contrast media was administrated at a flow rate of 3.5 and 5 mL/s, respectively. CT values, noise, signal-to-noise ratio, contrast-to-noise ratio (CNR) of the proximal segments of coronary arteries and subjective IQ were evaluated. Results The CT values and noise in group A were significantly lower than those in group B (434–485 Hounsfield units [HU] vs. 772–851 HU, all p < 0.001; 17.8–22.3 vs. 23.3–26.4, all p < 0.005). The CNRs of the right coronary artery and left main artery showed no statistical difference between the two groups (42.1 ± 13.8 vs. 36.8 ± 16.0, p = 0.074; 38.7 ± 10.6 vs. 38.1 ± 17.0, p = 0.819). No statistical difference was observed between the two groups in IQ scores (3.04 ± 0.75 vs. 3.0 ± 0.79, p = 0.526) and diagnostic ratio (96.1% [50/52] vs. 94.2% [49/52], p = 0.647). Conclusion Prospective high-pitch CCTA at 70 kVp with 28 mL of contrast media and injection rate of 3.5 mL/s could provide diagnostic IQ for normal-weight patients with heart rate of < 70 beats/min.
Collapse
Affiliation(s)
- Ruiqi Feng
- Department of Radiology, The First Affiliated Hospital of China Medical University, Shenyang 110001, P.R. China
| | - Jiajie Tong
- Department of Radiology, Hebei General Hospital, Shijiazhuang 050051, P.R. China
| | - Xiaofei Liu
- Department of Radiology, The First Affiliated Hospital of China Medical University, Shenyang 110001, P.R. China
| | - Yu Zhao
- Department of Radiology, The First Affiliated Hospital of China Medical University, Shenyang 110001, P.R. China
| | - Liang Zhang
- Department of Radiology, The First Affiliated Hospital of China Medical University, Shenyang 110001, P.R. China
| |
Collapse
|
7
|
Zhang J, Kang S, Han D, Xie X, Deng Y. Application of intelligent optimal kV scanning technology (CARE kV) in dual-source computed tomography (DSCT) coronary angiography. Int J Clin Exp Med 2015; 8:17644-17653. [PMID: 26770354 PMCID: PMC4694254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2015] [Accepted: 09/10/2015] [Indexed: 06/05/2023]
Abstract
This study aims to evaluate the applications and values of dual-source computed tomography (DSCT) intelligent optimal kV scanning technology (CARE kV) in coronary CT angiography (CCTA). 150 patients with normal body mass index were performed DSCT coronary angiography, then randomly divided into the "Semi", 120,100 and 80 kV Group, and the 2 "on" groups, with 30 patients in each group. The first 5 groups used the reference voltage as 120 kV, and the reference current as 400 mAs, while the other group used the reference voltage as 100 kV, and the reference current as 400 mAs. The image quality, average CT value, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose were comparatively analyzed among the 5 groups. The image quality scores of the five groups showed no significant difference (P > 0.05); the average CT values and image noises had significance (P < 0.05), while SNR and CNR showed no significant difference (P > 0.05). The 80 kV group showed the biggest noise, with the CT value as 700 HU, while the radiation dose was the lowest, followed by the on group. As for the patients with normal body mass index (BMI), CARE kV-"on" could obtain high-quality images and lower radiation dose for CCTA, while the operation was simple and convenient.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Medical Imaging, The First Affiliated Hospital of Kunming Medical UniversityKunming 650032, China
- Department of Medical Imaging, Taizhou People’s HospitalTaizhou 225300, China
| | - Shaolei Kang
- Department of Medical Imaging, The First Affiliated Hospital of Kunming Medical UniversityKunming 650032, China
| | - Dan Han
- Department of Medical Imaging, The First Affiliated Hospital of Kunming Medical UniversityKunming 650032, China
| | - Xiaojie Xie
- Department of Medical Imaging, The First Affiliated Hospital of Kunming Medical UniversityKunming 650032, China
| | - Yaming Deng
- Department of Medical Imaging, The First Affiliated Hospital of Kunming Medical UniversityKunming 650032, China
| |
Collapse
|