Yu W, Zou D, Tan J, Zheng N, Ma X, Cheng R, Chen Y, Tsai TY. Medial-pivot total knee arthroplasty enhances tibiofemoral axial rotation stability in weight-bearing mid-range flexion compared to posterior-stabilised system. Knee Surg Sports Traumatol Arthrosc 2024. [PMID: 38713882 DOI: 10.1002/ksa.12200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 04/03/2024] [Accepted: 04/07/2024] [Indexed: 05/09/2024]
Abstract
PURPOSE Total knee arthroplasty (TKA) stands as a primary intervention for severe knee ailments, yet concerns remain regarding postoperative patient satisfaction and flexion instability. This study aims to evaluate the in-vivo kinematics of medial-pivot (MP) and posterior-stabilised (PS) designs during step-up activity, in comparison to the kinematics of the nonoperated contralateral knee. METHODS Sixteen patients with PS-TKA and 14 with MP-TKA were retrospectively examined. Clinical outcomes were assessed using patient-completed questionnaires. Motion during step-up was captured using a dual fluoroscopic system. Statistical analysis was applied to evaluate the in-vivo tibiofemoral six-degree-of-freedom kinematics and articular contact positions between the two groups. RESULTS Despite being older, patients in the MP group reported higher postoperative subjective scores for weight-bearing functional activities. The axial rotation centres of MP-TKA located on the medial tibial plateau exhibited less variance compared to PS-TKA and contralateral knees. Compared to the contralateral knee (contralateral to medial-pivot [C-MP] or contralateral to posterior-stabilised [C-PS]), the MP group exhibited limited range of motion in terms of anteroposterior translation (MP: 3.6 ± 1.3 mm vs. C-MP: 7.4 ± 2.5 mm, p < 0.01) and axial rotation (MP: 6.6 ± 1.9° vs. C-MP: 10.3 ± 4.9°, p = 0.02), as well as in the PS group for anteroposterior translation (PS: 3.9 ± 1.7 mm vs. C-PS: 7.2 ± 3.7 mm, p < 0.01). CONCLUSION The MP group with better postoperative ratings demonstrated a more stable MP axial rotation pattern during step-up activity compared to the PS group, underscoring the pivotal role of prosthetic design in optimising postoperative rehabilitation and functional recovery. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Wanxin Yu
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Diyang Zou
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jiaqi Tan
- Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Nan Zheng
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xin Ma
- Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Rongshan Cheng
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yunsu Chen
- Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Tsung-Yuan Tsai
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Research and Development Division, TAOiMAGE Medical Technologies Corporation, Shanghai, China
| |
Collapse
|
2
|
Guo N, Smith CR, Schütz P, Trepczynski A, Moewis P, Damm P, Maas A, Grupp TM, Taylor WR, Hosseini Nasab SH. Posterior tibial slope influences joint mechanics and soft tissue loading after total knee arthroplasty. Front Bioeng Biotechnol 2024; 12:1352794. [PMID: 38686117 PMCID: PMC11056792 DOI: 10.3389/fbioe.2024.1352794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 03/26/2024] [Indexed: 05/02/2024] Open
Abstract
As a solution to restore knee function and reduce pain, the demand for Total Knee Arthroplasty (TKA) has dramatically increased in recent decades. The high rates of dissatisfaction and revision makes it crucially important to understand the relationships between surgical factors and post-surgery knee performance. Tibial implant alignment in the sagittal plane (i.e., posterior tibia slope, PTS) is thought to play a key role in quadriceps muscle forces and contact conditions of the joint, but the underlying mechanisms and potential consequences are poorly understood. To address this biomechanical challenge, we developed a subject-specific musculoskeletal model based on the bone anatomy and precise implantation data provided within the CAMS-Knee datasets. Using the novel COMAK algorithm that concurrently optimizes joint kinematics, together with contact mechanics, and muscle and ligament forces, enabled highly accurate estimations of the knee joint biomechanics (RMSE <0.16 BW of joint contact force) throughout level walking and squatting. Once confirmed for accuracy, this baseline modelling framework was then used to systematically explore the influence of PTS on knee joint biomechanics. Our results indicate that PTS can greatly influence tibio-femoral translations (mainly in the anterior-posterior direction), while also suggesting an elevated risk of patellar mal-tracking and instability. Importantly, however, an increased PTS was found to reduce the maximum tibio-femoral contact force and improve efficiency of the quadriceps muscles, while also reducing the patellofemoral contact force (by approximately 1.5% for each additional degree of PTS during walking). This study presents valuable findings regarding the impact of PTS variations on the biomechanics of the TKA joint and thereby provides potential guidance for surgically optimizing implant alignment in the sagittal plane, tailored to the implant design and the individual deficits of each patient.
Collapse
Affiliation(s)
- Ning Guo
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland
| | - Colin R. Smith
- Department of Biomedical Engineering, Steadman Philippon Research Institute, Vail, CO, United States
| | - Pascal Schütz
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland
| | - Adam Trepczynski
- Julius Wolff Institute, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Philippe Moewis
- Julius Wolff Institute, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Philipp Damm
- Julius Wolff Institute, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Allan Maas
- Aesculap AG, Tuttlingen, Germany
- Department of Orthopaedic and Trauma Surgery, Ludwig Maximilians University Munich, Musculoskeletal University Center Munich (MUM), Munich, Germany
| | - Thomas M. Grupp
- Aesculap AG, Tuttlingen, Germany
- Department of Orthopaedic and Trauma Surgery, Ludwig Maximilians University Munich, Musculoskeletal University Center Munich (MUM), Munich, Germany
| | - William R. Taylor
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland
| | | |
Collapse
|
3
|
Glenday JD, Vigdorchik JM, Sculco PK, Kahlenberg CA, Mayman DJ, Debbi EM, Lipman JD, Wright TM, González FJQ. A novel computational workflow to holistically assess total knee arthroplasty biomechanics identifies subject-specific effects of joint mechanics on implant fixation. J Biomech 2024; 164:111973. [PMID: 38325192 DOI: 10.1016/j.jbiomech.2024.111973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 12/04/2023] [Accepted: 01/29/2024] [Indexed: 02/09/2024]
Abstract
Computational studies of total knee arthroplasty (TKA) often focus on either joint mechanics (kinematics and forces) or implant fixation mechanics. However, such disconnect between joint and fixation mechanics hinders our understanding of overall TKA biomechanical function by preventing identification of key relationships between these two levels of TKA mechanics. We developed a computational workflow to holistically assess TKA biomechanics by integrating musculoskeletal and finite element (FE) models. For our initial study using the workflow, we investigated how tibiofemoral contact mechanics affected the risk of failure due to debonding at the implant-cement interface using the four available subjects from the Grand Challenge Competitions to Predict In Vivo Knee Loads. We used a musculoskeletal model with a 12 degrees-of-freedom knee joint to simulate the stance phase of gait for each subject. The computed tibiofemoral joint forces at each node in contact were direct inputs to FE simulations of the same subjects. We found that the peak risk of failure did not coincide with the peak joint forces or the extreme tibiofemoral contact positions. Moreover, despite the consistency of joint forces across subjects, we observed important variability in the profile of the risk of failure during gait. Thus, by a combined evaluation of the joint and implant fixation mechanics of TKA, we could identify subject-specific effects of joint kinematics and forces on implant fixation that would otherwise have gone unnoticed. We intend to apply our workflow to evaluate the impact of implant alignment and design on TKA biomechanics.
Collapse
Affiliation(s)
- Jonathan D Glenday
- Hospital for Special Surgery, 535 East 71st Street, New York 10021, NY, USA
| | | | - Peter K Sculco
- Hospital for Special Surgery, 535 East 71st Street, New York 10021, NY, USA
| | | | - David J Mayman
- Hospital for Special Surgery, 535 East 71st Street, New York 10021, NY, USA
| | - Eytan M Debbi
- Hospital for Special Surgery, 535 East 71st Street, New York 10021, NY, USA
| | - Joseph D Lipman
- Hospital for Special Surgery, 535 East 71st Street, New York 10021, NY, USA
| | - Timothy M Wright
- Hospital for Special Surgery, 535 East 71st Street, New York 10021, NY, USA
| | | |
Collapse
|
4
|
Kim S, Han S, Kim S, Moon J. The effects of knee ligament load using simulated hip abductor and hamstring muscle strengthening during cutting maneuver. Medicine (Baltimore) 2023; 102:e35742. [PMID: 37986289 PMCID: PMC10659627 DOI: 10.1097/md.0000000000035742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 09/03/2023] [Accepted: 09/29/2023] [Indexed: 11/22/2023] Open
Abstract
BACKGROUND This study aimed to analyze knee ligament of load and joint moment to simulate the strengthening of the hip abductor and hamstring muscles using musculoskeletal modeling, thereby contributing to decrease of knee ligament load. METHODS Forty participants (age: 21.85 ± 1.90 years; height: 1.76 ± 0.06 m; body mass: 68.5 ± 7.06 kg) were instructed to run at 4.5 ± 0.2 m/s from a 5 m distance posterior to the force plate, land their feet on the force plate, and perform the cutting maneuver on the left. In the musculoskeletal modeling, the hip abductor and hamstring muscles were targeted to construct a model with a 30% increase in the contraction force of the hip abductor, hamstring, and both 2 muscles. The variables were the ligament force and knee joint moment. One-way repeated measure ANOVA and Bonferroni test were used to compare the abductor/hamstring, abductor, hamstring and control models. RESULTS There were significant differences in anterior bundle of the anterior cruciate ligament (ACL) (P = .001), inferior bundle of the superficial layer of the medial collateral ligament (MCL) (P = .016), and posterior bundle of the superficial layer of the MCL (P = .022) force. The post hoc showed that the hamstring model had lower anterior bundle of the ACL and inferior bundle of the superficial layer of the MCL than the abductor/hamstring and abductor models (P < .05) and lower posterior bundle of the superficial layer of the MCL than the abductor and control models (P < .05). There was a significant difference in the adduction (P = .028) and internal rotation moments (P = .014). The post hoc showed that both moments were lower in the hamstring model than in the other models (P < .05). CONCLUSIONS The hamstring strengthening may contribute significantly to preventing ACL or MCL injury by reducing knee ligament load.
Collapse
Affiliation(s)
- Sungmin Kim
- Institute of School Physical Education, Korea National University of Education, Chungbuk, Republic of Korea
| | - Sanghyuk Han
- Human Performance Laboratory, Descente Innovation Studio Complex, Busan, Republic of Korea
| | - Seongyong Kim
- Futures R&D Center, SSG LANDERS, Incheon, Republic of Korea
| | - Jeheon Moon
- Department of Physical Education, Korea National University of Education, Chungbuk, Republic of Korea
| |
Collapse
|
5
|
Kono K, Inui H, Tomita T, Yamazaki T, Konda S, Taketomi S, Tanaka S, D'Lima DD. Bicruciate-retaining total knee arthroplasty procedure reduced tensile force in the middle and posterior components of lateral collateral ligament during deep knee flexion activities with no effect on tensile force of the medial collateral ligament. Knee Surg Sports Traumatol Arthrosc 2023; 31:3889-3897. [PMID: 36928366 DOI: 10.1007/s00167-023-07342-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Accepted: 02/05/2023] [Indexed: 03/18/2023]
Abstract
PURPOSE To analyse the effects of bicruciate-retaining total knee arthroplasty (BCR-TKA) on the tensile force of the collateral ligaments during two deep knee flexion activities, cross-leg sitting and squatting. METHODS Thirteen patients (15 knees) treated using bicruciate-retaining total knee arthroplasty (BCR-TKA) for knee joint osteoarthritis were analysed. Knee joint kinematics during cross-leg sitting (open-chain flexion) and squatting (closed-chain flexion) were evaluated through fluoroscopy. The tensile force was calculated in vivo based on the change in the distance between the femoral and tibial attachment areas for the anterior, middle, and posterior components of the superficial (sMCL) and deep (dMCL) medial collateral ligament and the lateral collateral ligament (LCL). Differences in the calculated tensile forces of the collateral ligaments were evaluated using repeated measures of analysis of variance, with post hoc pairwise comparison (Bonferroni test). Statistical significance was set at P ≤ 0.05. RESULTS The correction of the coronal alignment was related to the surgical technique, not to the implant design. No significant change in the tensile force in all three components of the sMCL from pre- to post-TKA (n.s.) was observed. For dMCL, a pre- to post-TKA change in the tensile force was observed only for the anterior dMCL component (p = 0.03). No change was observed in the tensile force of the anterior LCL with increasing flexion, with no difference in pre- to post-TKA and between activities (n.s.). In contrast, tensile force in the middle LCL slightly decreased with increasing flexion during squatting, pre- and post-TKA. After surgery, lower forces were generated at 40° of flexion (p = 0.04). Tensile force in the posterior LCL was higher in extension than flexion, which remained high in the extension post-TKA. However, after surgery, lower tensile forces were generated at 10° (p = 0.04) and 40° (p = 0.04) of flexion. CONCLUSIONS The in vivo change in tensile forces of the collateral ligaments of the knee before and after BCR-TKA can inform the development of appropriate ligament balancing strategies to facilitate recovery of deep knee flexion activities after TKA, as well as for continued improvement of BCR-TKA designs. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Kenichi Kono
- Department of Molecular Medicine Arthritis Research, The Scripps Research Institute, La Jolla, CA, USA
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Hiroshi Inui
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
| | - Tetsuya Tomita
- Department of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
- Master Course of Health Sciences, Graduate School of Health Sciences, Morinomiya University of Medical Sciences, Osaka, Japan
| | - Takaharu Yamazaki
- Department of Information Systems, Faculty of Engineering, Saitama Institute of T1echnology, Fukaya, Saitama, Japan
| | - Shoji Konda
- Department of Health and Sport Sciences, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Shuji Taketomi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Sakae Tanaka
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Darryl D D'Lima
- Department of Molecular Medicine Arthritis Research, The Scripps Research Institute, La Jolla, CA, USA
- Shiley Center for Orthopaedic Research & Education at Scripps Clinic, La Jolla, CA, USA
| |
Collapse
|
6
|
Zou D, Ling Z, Tan J, Zheng N, Dimitriou D, Chen Y, Tsai TY. Medial stability and lateral flexibility of the collateral ligaments during mid-range flexion in medial-pivot total knee arthroplasty patients demonstrates favorable postoperative outcomes. Knee Surg Sports Traumatol Arthrosc 2023; 31:3734-3744. [PMID: 36670261 DOI: 10.1007/s00167-023-07307-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 12/26/2022] [Indexed: 01/22/2023]
Abstract
PURPOSE The objectives of the present study were to investigate the length change in different bundles of the superficial medial collateral ligament (sMCL) and lateral collateral ligament (LCL) during lunge, and to evaluate their association with Knee Society Score (KSS) following medial-pivot total knee arthroplasty (MP-TKA). METHODS Patients with unilateral MP-TKA knees performed a bilateral single-leg lunge under dual fluoroscopy surveillance to determine the in-vivo six degrees-of-freedom knee kinematics. The contralateral non-operated knees were used as the control group. The attachment sites of the sMCL and LCL were marked to calculate the 3D wrapping length. The sMCL and LCL were divided into anterior, intermediate, and posterior portions (aMCL, iMCL, pMCL, aLCL, iLCL, pLCL). Correlations between lengths/elongation rate of ligament bundles from full extension to 100° flexion and the KSS were examined. RESULTS The sMCL and LCL demonstrated relative stability in length at low flexion, but sMCL length decreased whereas LCL increased with further flexion on operated knees. The sMCL length increased at low flexion and remained stable with further flexion, while the LCL length decreased with flexion on the contralateral non-operated knees. The lengths of aMCL, iMCL, and pMCL showed moderate (0.5 < r < 0.7, p < 0.05) negative correlations with the KSS, and the lengths of aLCL, iLCL, and pLCL were positively correlated with the KSS at mid flexion on operated knees (p < 0.05). The elongation rates of aLCL, iLCL, and pLCL were negatively correlated with the KSS at high flexion on operated knees (p < 0.05). However, no significant correlations between the length of different bundles of sMCL or LCL with KSS were found on contralateral non-operated knees. CONCLUSIONS The elongation pattern of sMCL/LCL on MP-TKA knees showed differences with contralateral non-operated knees. The sMCL is tense at low to middle flexion and relaxed at high flexion, while LCL is relaxed at low to middle flexion and tense at high flexion following MP-TKA. Medial stability and proper lateral flexibility during mid flexion were associated with favorable postoperative outcomes in MP-TKA patients. In contrast, lateral relaxation at deep flexion should be avoided when applying soft-tissue balancing in MP-TKA. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Diyang Zou
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University; Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopaedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Zhi Ling
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University; Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopaedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jiaqi Tan
- Department of Orthopedics, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Nan Zheng
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University; Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopaedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Dimitris Dimitriou
- Department of Orthopedics, Balgrist University Hospital, Forchstrasse 340, CH-8008, Zürich, Switzerland.
| | - Yunsu Chen
- Department of Orthopedics, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China.
| | - Tsung-Yuan Tsai
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University; Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China.
- Shanghai Key Laboratory of Orthopaedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
| |
Collapse
|
7
|
Larger Medial Contact Area and More Anterior Contact Position in Medial-Pivot than Posterior-Stabilized Total Knee Arthroplasty during In-Vivo Lunge Activity. Bioengineering (Basel) 2023; 10:bioengineering10030290. [PMID: 36978681 PMCID: PMC10045283 DOI: 10.3390/bioengineering10030290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/06/2023] [Accepted: 02/10/2023] [Indexed: 03/03/2023] Open
Abstract
This study aimed to compare the in-vivo kinematics and articular contact status between medial-pivot total knee arthroplasty (MP-TKA) and posterior stabilized (PS) TKA during weight-bearing single-leg lunge. 16 MP-TKA and 12 PS-TKA patients performed bilateral single-leg lunges under dual fluoroscopy surveillance to determine the in-vivo six degrees-of-freedom knee kinematics. The closest point between the surface models of the femoral condyle and the polyethylene insert was used to determine the contact position and area. The nonparametric statistics analysis was performed to test the symmetry of the kinematics between MP-TKA and PS-TKA. PS-TKA demonstrated a significantly greater range of AP translation than MP-TKA during high flexion (p = 0.0002). Both groups showed a significantly greater range of lateral compartment posterior translation with medial pivot rotation. The contact points of PS-TKA were located significantly more posterior than MP-TKA in both medial (10°–100°) and lateral (5°–40°, 55°–100°) compartments (p < 0.0500). MP-TKA had a significantly larger contact area in the medial compartment than in the lateral compartment. In contrast, no significant differences were observed in PS-TKA. The present study revealed no significant differences in clinical outcomes between the MP and PS groups. The PS-TKA demonstrated significantly more posterior translations than MP-TKA at high flexion. The contact points are located more posteriorly in PS-TKA compared with MP-TKA. A larger contact area and medial pivot pattern during high flexion in MP-TKA indicated that MP-TKA provides enhanced medial pivot rotation.
Collapse
|
8
|
Innocenti B, Bori E, Paszicsnyek T. Functional stability: an experimental knee joint cadaveric study on collateral ligaments tension. Arch Orthop Trauma Surg 2022; 142:1213-1220. [PMID: 34046716 DOI: 10.1007/s00402-021-03966-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Accepted: 05/18/2021] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Applying proper tension to collateral ligaments during total knee arthroplasty surgery is fundamental to achieve optimal implant performance: low tension could lead to joint instability, over-tensioning leads to pain and stiffness. A "functional stability" must be defined and achieved during surgery to guarantee optimal results. In this study, an experimental cadaveric activity was performed to measure the minimum tension required to achieve knee functional stability. MATERIALS AND METHODS Ten knee specimens were investigated; femur and tibia were fixed in specifically designed fixtures and clamped to a loading frame; constant displacement rate was applied and resulting tension force was measured. Joint stability was determined as the slope change in the force/displacement curve, representing the activation of both collateral ligaments elastic region; the tension required to reach joint functional stability is then the span between ligaments toe region and this point. Intact, ACL (anterior cruciate ligament)-resected and ACL & PCL (posterior cruciate ligament)-resected knees were tested. The test was performed at different flexion angles; each configuration was analyzed three times. RESULTS Results demonstrated an overall tension of 40-50 N to be enough to reach stability in intact knees. Similar values are sufficient in ACL-resected knees, while significantly higher tension is required (up to 60 N) after cruciate ligaments resection. The tension required was slightly higher at 60° of flexion. CONCLUSION Results agree with other experimental studies, showing that the tensions required to stabilize a knee joint are lower than the ones applied nowadays via surgical tensioners. To reach functional stability, surgeons should consider such results intraoperatively and avoid ligament laxity or over-tension.
Collapse
Affiliation(s)
- Bernardo Innocenti
- BEAMS Department, Bio Electro and Mechanical Systems, École Polytechnique de Bruxelles, Université Libre de Bruxelles, Av. F. Roosevelt, 50 CP165/56, 1050, Bruxelles, Belgium.
| | - Edoardo Bori
- BEAMS Department, Bio Electro and Mechanical Systems, École Polytechnique de Bruxelles, Université Libre de Bruxelles, Av. F. Roosevelt, 50 CP165/56, 1050, Bruxelles, Belgium
| | | |
Collapse
|
9
|
Rao L, Taylor WR, Horn N, List R, Preiss S, Schütz P. Can tibio-femoral kinematic and kinetic parameters reveal poor functionality and underlying deficits after total knee replacement? A systematic review. Knee 2022; 34:62-75. [PMID: 34883331 DOI: 10.1016/j.knee.2021.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 09/13/2021] [Accepted: 11/04/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Extensive efforts have been made to understand joint kinematics and kinetics in total knee arthroplasty (TKA) in subjects with satisfactory outcomes during daily functional activities and clinical tests, but it remains unclear whether such movement characteristics hold the potential to indicate the underlying aetiology of unsatisfactory or bad TKA outcomes. PURPOSE To investigate which kinematic and kinetic parameters assessed during passive clinical tests and functional activities of daily living are associated with poor functionality and underlying deficits after total knee replacement. METHODS We focused on studies characterizing the kinematic or kinetic parameters of the knee joint that are associated with poor clinical outcome after TKA. Seventeen articles were included for the review, and kinematic and kinetic data from 719 patients with minimal follow up of 6 months were extracted and analyzed. RESULTS Passive posterior translation at 90°flexionexhibited good potential for differentiating stable and unstable TKAs. Anterior-posterior (A-P) translation of the medial condyle at 0-30° and 30-60° flexion, A-P translation of the lateral condyle at 60-90°during closed chain exercises, as well asknee extension moment during stair ascent and descent, knee abduction moment during stair descent, knee internal rotation moment and plantar flexion moment during walking, 2ndpeak ground reaction force during stair ascent and walkingshowed the greatest promise as functional biomarkers for a dissatisfied/poor outcome knee after TKA. CONCLUSION In this study, we systematically reviewed the state-of-the-art knowledge of kinematics and kinetics associated with functional deficits, and found 11 biomechanical parameters that showed promise for supportingdecision making in TKA.
Collapse
Affiliation(s)
- L Rao
- Institute for Biomechanics, ETH Zurich, Zürich, Switzerland
| | - W R Taylor
- Institute for Biomechanics, ETH Zurich, Zürich, Switzerland.
| | - N Horn
- Schulthess Clinic, Zürich, Switzerland
| | - R List
- Schulthess Clinic, Zürich, Switzerland
| | - S Preiss
- Schulthess Clinic, Zürich, Switzerland
| | - P Schütz
- Institute for Biomechanics, ETH Zurich, Zürich, Switzerland
| |
Collapse
|
10
|
Hosseini Nasab SH, Smith CR, Postolka B, Schütz P, List R, Taylor WR. In Vivo Elongation Patterns of the Collateral Ligaments in Healthy Knees During Functional Activities. J Bone Joint Surg Am 2021; 103:1620-1627. [PMID: 33848100 DOI: 10.2106/jbjs.20.01311] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Improved knowledge of in vivo function of the collateral ligaments is essential for enhancing rehabilitation and guiding surgical reconstruction as well as soft-tissue balancing in total knee arthroplasty. The aim of this study was to quantify in vivo elongation patterns of the collateral ligaments throughout complete cycles of functional activities. METHODS Knee kinematics were measured using radiographic images captured with a mobile fluoroscope while healthy subjects performed level walking, downhill walking, and stair descent. The registered in vivo tibiofemoral kinematics were then used to drive subject-specific multibody knee models to track collateral ligament elongation. RESULTS The elongation patterns of the medial collateral ligament varied distinctly among its bundles, ranging from lengthening of the anterior fibers to shortening of the posterior bundle with increases in the knee flexion angle. The elongation patterns of the lateral collateral ligament varied considerably among subjects. It showed an average 4% shortening with increasing flexion until 60% to 70% of the gait cycle, and then recovered during the terminal-swing phase until reaching its reference length (defined at heel strike). CONCLUSIONS The observed nonuniform elongation of the medial collateral ligament bundles suggests that single-bundle reconstruction techniques may not fully restore healthy ligament function. Moreover, the observed ligament elongation patterns indicate greater varus than valgus laxity in the loaded knee. CLINICAL RELEVANCE Through providing key knowledge about the in vivo elongation patterns of the collateral ligaments throughout complete cycles of functional activities, this study offers in vivo evidence for benchmarking ligament reconstruction and soft-tissue balancing in total knee arthroplasty.
Collapse
Affiliation(s)
- S H Hosseini Nasab
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - C R Smith
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - B Postolka
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - P Schütz
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - R List
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland.,Human Performance Lab, Schulthess Clinic, Zürich, Switzerland
| | - W R Taylor
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| |
Collapse
|
11
|
Zaylor W, Halloran JP. WraptMor: Confirmation of an Approach to Estimate Ligament Fiber Length and Reactions With Knee-Specific Morphology. J Biomech Eng 2021; 143:1106711. [PMID: 33825816 DOI: 10.1115/1.4050810] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Indexed: 12/24/2022]
Abstract
Knee ligament length can be used to infer ligament recruitment during functional activities and subject-specific morphology affects the interplay between ligament recruitment and joint motion. This study presents an approach that estimated ligament fiber insertion-to-insertion lengths with wrapping around subject-specific osseous morphology (WraptMor). This represents an advancement over previous work that utilized surrogate geometry to approximate ligament interaction with bone surfaces. Additionally, the reactions each ligament imparted onto bones were calculated by assigning a force-length relationship (kinetic WraptMor model), which assumed that the insertion-to-insertion lengths were independent of the assigned properties. Confirmation of the approach included comparing WraptMor predicted insertion-to-insertion length and reactions with an equivalent displacement-controlled explicit finite element model. Both models evaluated 10 ligament bundles at 16 different joint positions, which were repeated for five different ligament prestrain values for a total of 80 simulations per bundle. The WraptMor and kinetic WraptMor models yielded length and reaction predictions that were similar to the equivalent finite element model. With a few exceptions, predicted ligament lengths and reactions agreed to within 0.1 mm and 2.0 N, respectively, across all tested joint positions and prestrain values. The primary source of discrepancy between the models appeared to be caused by artifacts in the finite element model. The result is a relatively efficient approach to estimate ligament lengths and reactions that include wrapping around knee-specific bone surfaces.
Collapse
Affiliation(s)
- William Zaylor
- Department of Mechanical Engineering, Cleveland State University, Cleveland OH 44115
| | - Jason P Halloran
- Applied Sciences Laboratory, Institute for Shock Physics, Washington State University, Spokane, Washington, DC 99164
| |
Collapse
|
12
|
Tan J, Zou D, Zhang X, Zheng N, Pan Y, Ling Z, Tsai TY, Chen Y. Loss of Knee Flexion and Femoral Rollback of the Medial-Pivot and Posterior-Stabilized Total Knee Arthroplasty During Early-Stance of Walking in Chinese Patients. Front Bioeng Biotechnol 2021; 9:675093. [PMID: 34249882 PMCID: PMC8264512 DOI: 10.3389/fbioe.2021.675093] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 05/06/2021] [Indexed: 11/13/2022] Open
Abstract
Background The medial-pivot (MP) prosthesis was developed to produce more physiological postoperative knee kinematics and better patient satisfaction than traditional prostheses, but outcomes are inconsistent in different studies of Caucasian patients. This study aimed to investigate the postoperative patient satisfaction and in vivo knee kinematics of the MP and posterior-stabilized (PS) prosthesis during gait activity in Chinese patients. Methods A retrospective analysis of 12 patients was received for this study in each MP group and PS group. Patient-reported satisfaction level and Forgotten Joint Score (FJS) were evaluated with questionnaires. A dual fluoroscopic imaging system was used to investigate in vivo knee kinematics of MP and PS total knee arthroplasty (TKA) during treadmill walking at a speed of 0.4 m/s. Results Comparable promising patient satisfaction and overall FJS (MP 60.7 ± 15.35 vs. PS 51.3 ± 17.62, p = 0.174) were found between the MP and PS groups. Peak flexion appeared at around 70% of gait cycle with values of 52.4 ± 7.4° for MP and 50.1 ± 3.6° for PS groups (no difference). Both groups maintained a stable position at the stance phase and began to translated anteriorly at toe-off with an amount of 4.5 ± 2.3 mm in the MP and 6.6 ± 2.7 mm in the PS (p = 0.08) group until late swing. The range of this external rotation motion was 5.9 ± 4.8 and 6.2 ± 4.1° (p = 0.79) for the MP and PS, respectively. Conclusion A similar knee kinematics pattern characterized by a loss of early-stance knee flexion and femoral rollback during walking was observed in the MP and PS TKAs. Our study confirmed similar effectiveness of MP TKA compared to PS TKA in Chinese patients, while the change of knee kinematics of both implants during slow walking should be noted.
Collapse
Affiliation(s)
- Jiaqi Tan
- Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Diyang Zou
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants and Clinical Translational R&D Center of 3D Printing Technology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xianlong Zhang
- Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Nan Zheng
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants and Clinical Translational R&D Center of 3D Printing Technology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yuqi Pan
- Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Zhi Ling
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants and Clinical Translational R&D Center of 3D Printing Technology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Tsung-Yuan Tsai
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants and Clinical Translational R&D Center of 3D Printing Technology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yunsu Chen
- Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
13
|
Fucentese SF, Koch PP. A novel augmented reality-based surgical guidance system for total knee arthroplasty. Arch Orthop Trauma Surg 2021; 141:2227-2233. [PMID: 34698930 PMCID: PMC8595230 DOI: 10.1007/s00402-021-04204-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 09/29/2021] [Indexed: 11/07/2022]
Abstract
INTRODUCTION Many of the functional complications that arise after total knee arthroplasty (TKA) are caused by a non-optimal balance of the knee after surgery. Over the past 20 years, technology has been used in the Operating Room (OR) to help improve precision and balance. The results of Computer-Assisted Surgery (CAS) and robotic systems show improved accuracy regarding implant positioning but a relatively small improvement in patient-reported outcomes and implant survival compared to conventional TKA. Recently, Augmented Reality (AR) has been proposed as a technology that could improve accuracy in orthopaedic surgery, providing a more efficient and cost-effective solution. MATERIALS AND METHODS This article describes a novel AR-based surgical guidance system that measures intra-operatively the effect of prosthesis alignment and positioning on soft tissue balance. The system is integrated in a pair of smart glasses and two small sensors and displays surgical targets directly in the field of view of the surgeon. RESULTS The system has been used in a limited number of cases. While the preliminary experience has been positive, clinical research is ongoing to confirm to confirm the performance of the system and the impact on clinical outcomes. CONCLUSION Augmented Reality can be a valuable tool to improve accuracy in TKA. The use of smart glasses and integrated sensors improves the efficiency of the procedure, particularly when coupled with single-use instrumentation. A novel protocol for soft tissue assessment allows for a 3-dimensional evaluation of the ligaments and a better measurement of the effect of tibial rotation.
Collapse
Affiliation(s)
- Sandro F. Fucentese
- grid.7400.30000 0004 1937 0650University Hospital Balgrist, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland
| | - Peter P. Koch
- grid.452288.10000 0001 0697 1703Department of Orthopaedic Surgery and Traumatology, Kantonsspital Winterthur, Brauerstrasse 15, 8401 Winterthur, Switzerland
| |
Collapse
|
14
|
Techniques for In Vivo Measurement of Ligament and Tendon Strain: A Review. Ann Biomed Eng 2020; 49:7-28. [PMID: 33025317 PMCID: PMC7773624 DOI: 10.1007/s10439-020-02635-5] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 09/22/2020] [Indexed: 12/13/2022]
Abstract
The critical clinical and scientific insights achieved through knowledge of in vivo musculoskeletal soft tissue strains has motivated the development of relevant measurement techniques. This review provides a comprehensive summary of the key findings, limitations, and clinical impacts of these techniques to quantify musculoskeletal soft tissue strains during dynamic movements. Current technologies generally leverage three techniques to quantify in vivo strain patterns, including implantable strain sensors, virtual fibre elongation, and ultrasound. (1) Implantable strain sensors enable direct measurements of tissue strains with high accuracy and minimal artefact, but are highly invasive and current designs are not clinically viable. (2) The virtual fibre elongation method tracks the relative displacement of tissue attachments to measure strains in both deep and superficial tissues. However, the associated imaging techniques often require exposure to radiation, limit the activities that can be performed, and only quantify bone-to-bone tissue strains. (3) Ultrasound methods enable safe and non-invasive imaging of soft tissue deformation. However, ultrasound can only image superficial tissues, and measurements are confounded by out-of-plane tissue motion. Finally, all in vivo strain measurement methods are limited in their ability to establish the slack length of musculoskeletal soft tissue structures. Despite the many challenges and limitations of these measurement techniques, knowledge of in vivo soft tissue strain has led to improved clinical treatments for many musculoskeletal pathologies including anterior cruciate ligament reconstruction, Achilles tendon repair, and total knee replacement. This review provides a comprehensive understanding of these measurement techniques and identifies the key features of in vivo strain measurement that can facilitate innovative personalized sports medicine treatment.
Collapse
|
15
|
Sayers MGL, Hosseini Nasab SH, Bachem C, Taylor WR, List R, Lorenzetti S. The effect of increasing heel height on lower limb symmetry during the back squat in trained and novice lifters. BMC Sports Sci Med Rehabil 2020; 12:42. [PMID: 32728445 PMCID: PMC7382835 DOI: 10.1186/s13102-020-00191-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 07/20/2020] [Indexed: 11/10/2022]
Abstract
Background Symmetry during lifting is considered critical for allowing balanced power production and avoidance of injury. This investigation assessed the influence of elevating the heels on bilateral lower limb symmetry during loaded (50% of body weight) high-bar back squats. Methods Ten novice (mass 67.6 ± 12.4 kg, height 1.73 ± 0.10 m) and ten regular weight trainers (mass 66.0 ± 10.7 kg, height 1.71 ± 0.09 m) were assessed while standing on both the flat level floor and on an inclined board. Data collection used infra-red motion capture procedures and two force platforms to record bilateral vertical ground reaction force (GRFvert) and ankle, knee and hip joint kinematic and kinetic data. Paired t-tests and statistical parametric mapping (SPM1D) procedures were used to assess differences in discrete and continuous bilateral symmetry data across conditions. Results Although discrete joint kinematic and joint moment symmetry data were largely unaffected by raising the heels, the regular weight trainers presented greater bilateral asymmetry in these data than the novices. The one significant finding in these discrete data showed that raising the heels significantly reduced maximum knee extension moment asymmetry (P = 0.02), but in the novice group only. Time-series analyses indicated significant bilateral asymmetries in both GRFvert and knee extension moments mid-way though the eccentric phase for the novice group, with the latter unaffected by heel lift condition. There were no significant bilateral asymmetries in time series data within the regular weight training group. Conclusions This investigation highlights that although a degree of bilateral lower limb asymmetry is common in individuals performing back squats, the degree of this symmetry is largely unaffected by raising the heels. Differences in results for discrete and time-series symmetry analyses also highlight a key issue associated with relying solely on discrete data techniques to assess bilateral symmetry during tasks such as the back squat.
Collapse
Affiliation(s)
- Mark G L Sayers
- School of Health and Sport Sciences, University of the Sunshine Coast, Queensland, Australia
| | | | | | | | - Renate List
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland.,Human Performance Lab, Schulthess Clinic, Zürich, Switzerland
| | - Silvio Lorenzetti
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland.,Swiss Federal Institute of Sport, Magglingen, Switzerland
| |
Collapse
|
16
|
Tibio-femoral kinematics of the healthy knee joint throughout complete cycles of gait activities. J Biomech 2020; 110:109915. [PMID: 32827791 DOI: 10.1016/j.jbiomech.2020.109915] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 06/02/2020] [Accepted: 06/25/2020] [Indexed: 12/30/2022]
Abstract
Accurate assessment of 3D tibio-femoral kinematics is essential for understanding knee joint functionality, but also provides a basis for assessing joint pathologies and the efficacy of musculoskeletal interventions. Until now, however, the assessment of functional kinematics in healthy knees has been mostly restricted to the loaded stance phase of gait, and level walking only, but the most critical conditions for the surrounding soft tissues are known to occur during high-flexion activities. This study aimed to determine the ranges of tibio-femoral rotation and condylar translation as well as provide evidence on the location of the centre of rotation during multiple complete cycles of different gait activities. Based on radiographic images captured using moving fluoroscopy in ten healthy subjects during multiple cycles of level walking, downhill walking and stair descent, 3D femoral and tibial poses were reconstructed to provide a comprehensive description of tibio-femoral kinematics. Despite a significant increase in joint flexion, the condylar antero-posterior range of motion remained comparable across all activities, with mean translations of 6.3-8.3 mm and 7.3-9.3 mm for the medial and lateral condyles respectively. Only the swing phase of level walking and stair descent exhibited a significantly greater range of motion for the lateral over the medial compartment. Although intra-subject variability was low, considerable differences in joint kinematics were observed between subjects. The observed subject-specific movement patterns indicate that accurate assessment of individual pre-operative kinematics together with individual implant selection and/or surgical implantation decisions might be necessary before further improvement to joint replacement outcome can be achieved.
Collapse
|
17
|
Length-Change Patterns of the Collateral Ligaments During Functional Activities After Total Knee Arthroplasty. Ann Biomed Eng 2020; 48:1396-1406. [PMID: 31974870 PMCID: PMC7089910 DOI: 10.1007/s10439-020-02459-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Accepted: 01/14/2020] [Indexed: 01/14/2023]
Abstract
This study aimed to quantify the elongation patterns of the collateral ligaments following TKA during functional activities of daily living. Using mobile video-fluoroscopy to capture radiographic images of the knee in a group of six patients, each with an ultra-congruent knee implant, tibiofemoral kinematics were reconstructed throughout complete cycles of level gait, downhill walking, stair descent, and squat activities. Kinematic data were then used to drive subject-specific multibody knee models to estimate length-change patterns of the LCL as well as three bundles of the MCL. In addition, a sensitivity analysis examined the role of the attachment site in the elongation patterns. Our data indicate a slackening of the LCL but non-uniform length-change patterns across the MCL bundles (ranging from lengthening of the anterior fibers to shortening of the posterior fibers) with increasing knee flexion angle. Near-isometric behavior of the intermediate fibers was observed throughout the entire cycle of the studied activities. These length-change patterns were found to be largely consistent across different activities. Importantly, length-change patterns were critically sensitive to the location of the femoral attachment points relative to the femoral component. Thus, in TKA with ultra-congruent implants, implantation of the femoral component may critically govern post-operative ligament function.
Collapse
|