Yan M, Liang T, Zhao H, Bi Y, Wang T, Yu T, Zhang Y. Model Properties and Clinical Application in the Finite Element Analysis of Knee Joint: A Review. Orthop Surg 2024; 16:289-302. [PMID: 38174410 PMCID: PMC10834231 DOI: 10.1111/os.13980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/21/2023] [Accepted: 12/04/2023] [Indexed: 01/05/2024] Open
Abstract
The knee is the most complex joint in the human body, including bony structures like the femur, tibia, fibula, and patella, and soft tissues like menisci, ligaments, muscles, and tendons. Complex anatomical structures of the knee joint make it difficult to conduct precise biomechanical research and explore the mechanism of movement and injury. The finite element model (FEM), as an important engineering analysis technique, has been widely used in many fields of bioengineering research. The FEM has advantages in the biomechanical analysis of objects with complex structures. Researchers can use this technology to construct a human knee joint model and perform biomechanical analysis on it. At the same time, finite element analysis can effectively evaluate variables such as stress, strain, displacement, and rotation, helping to predict injury mechanisms and optimize surgical techniques, which make up for the shortcomings of traditional biomechanics experimental research. However, few papers introduce what material properties should be selected for each anatomic structure of knee FEM to meet different research purposes. Based on previous finite element studies of the knee joint, this paper summarizes various modeling strategies and applications, serving as a reference for constructing knee joint models and research design.
Collapse
Affiliation(s)
- Mingyue Yan
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Ting Liang
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Haibo Zhao
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Yanchi Bi
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Tianrui Wang
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Tengbo Yu
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
- Department of Orthopedic Surgery, Qingdao Hospital, University of Health and Rehabilitation Sciences (Qingdao Municipal Hospital), Qingdao, China
| | - Yingze Zhang
- Department of Orthopedics, The Third Hospital of Hebei Medical University, Shijiazhuang, China
| |
Collapse
|
2
|
Zhang J, Zhang A, Han Q, Liu Y, Chen H, Ma M, Li Y, Chen B, Wang J. Porous metal block based on topology optimization to treat distal femoral bone defect in total knee revision. Biomech Model Mechanobiol 2023; 22:961-970. [PMID: 36696049 PMCID: PMC10167133 DOI: 10.1007/s10237-023-01692-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 11/26/2022] [Indexed: 01/26/2023]
Abstract
Metal block augmentations are common solutions in treating bone defects of total knee revision. However, the stress shielding and poor osteointegration resulted from metal block application could not be neglected in bone defects restoration. In this study, a novel porous metal block was designed with topology optimization to improve biomechanical performance. The biomechanical difference of the topologically optimized block, solid Ti6Al4V block, and porous Ti6Al4V block in treating bone defects of total knee revision was compared by finite element analysis. The inhomogeneous femoral model was created according to the computed tomography data. Combined with porous structures, minimum compliance topology optimization subjected to the volume fraction constraint was utilized for the redesign of the metal block. The region of interest was defined as a 10 mm area of the distal femur beneath the contacting surface. The biomechanical performance of daily motions was investigated. The von Mises stress, the strain energy density of the region of interest, and the von Mises stress of metal blocks were recorded. The results were analyzed in SPSS. In terms of the region of interest, the maximum von Mises stress of the topological optimized group increased obviously, and its average stress was significantly higher than that of the other groups (p < 0.05). Moreover, the topologically optimized block group had the highest maximum strain energy density of the three groups, and the lowest maximum stress of block was also found in this group. In this study, the stress shielding reduction and stress transfer capability were found obviously improved through topology optimization. Therefore, the topological optimized porous block is recommended in treating bone defects of total knee revision. Meanwhile, this study also provided a novel approach for mechanical optimization in block designing.
Collapse
Affiliation(s)
- Jiangbo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Aobo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Qing Han
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Yang Liu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Hao Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Mingyue Ma
- Department of Breast Surgery, The First Hospital of Jilin University, Changchun, 130021, China
| | - Yongyue Li
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Bingpeng Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China.
| | - Jincheng Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| |
Collapse
|
3
|
Zhang ZH, Qi YS, Wei BG, Bao HRC, Xu YS. Application strategy of finite element analysis in artificial knee arthroplasty. Front Bioeng Biotechnol 2023; 11:1127289. [PMID: 37265991 PMCID: PMC10230366 DOI: 10.3389/fbioe.2023.1127289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 03/27/2023] [Indexed: 06/03/2023] Open
Abstract
Artificial knee arthroplasty, as the most effective method for the treatment of end-stage joint diseases such as knee osteoarthritis and rheumatoid arthritis, is widely used in the field of joint surgery. At present, Finite element analysis (FEA) has been widely used in artificial knee replacement biomechanical research. This review presents the current hotspots for the application of FEA in the field of artificial knee replacement by reviewing the existing research literature and, by comparison, summarizes guidance and recommendations for artificial knee replacement surgery. We believe that lower contact stress can produce less wear and complications when components move against each other, in the process of total knee arthroplasty (TKA), mobile-bearing prostheses reduce the contact surface stress of the tibial-femoral joint compared with fixed-bearing prostheses, thus reducing the wear of the polyethylene insert. Compared with mechanical alignment, kinematic alignment reduces the maximum stress and maximum strain of the femoral component and polyethylene insert in TKA, and the lower stress reduces the wear of the joint contact surface and prolongs the life of the prosthesis. In the unicompartmental knee arthroplasty (UKA), the femoral and tibial components of mobile-bearing prostheses have better conformity, which can reduce the wear of the components, while local stress concentration caused by excessive overconformity of fixed-bearing prostheses should be avoided in UKA to prevent accelerated wear of the components, the mobile-bearing prosthesis maintained in the coronal position from 4° varus to 4° valgus and the fixed-bearing prosthesis implanted in the neutral position (0°) are recommended. In revision total knee arthroplasty (RTKA), the stem implant design should maintain the best balance between preserving bone and reducing stress around the prosthesis after implantation. Compared with cemented stems, cementless press-fit femoral stems show higher fretting, for tibial plateau bone defects, porous metal blocks are more effective in stress dispersion. Finally, compared with traditional mechanical research methods, FEA methods can yield relatively accurate simulations, which could compensate for the deficiencies of traditional mechanics in knee joint research. Thus, FEA has great potential for applications in the field of medicine.
Collapse
Affiliation(s)
- Zi-Heng Zhang
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
- Graduate School, Inner Mongolia Medical University, Hohhot, China
| | - Yan-Song Qi
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| | - Bao-Gang Wei
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| | - Hu-Ri-Cha Bao
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| | - Yong-Sheng Xu
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| |
Collapse
|
4
|
Wan Q, Zhang A, Liu Y, Chen H, Zhang J, Xue H, Han Q, Wang J. The influence of body weight index on initial stability of uncemented femoral knee protheses: A finite element study. Heliyon 2023; 9:e13819. [PMID: 36895366 PMCID: PMC9988490 DOI: 10.1016/j.heliyon.2023.e13819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 02/07/2023] [Accepted: 02/13/2023] [Indexed: 02/19/2023] Open
Abstract
Background and objective Obesity is one of the risk factors for osteoarthritis. The end-stage treatment for osteoarthritis is total knee arthroplasty (TKA). However, it remains controversial whether a high body mass index (BMI) affects the initial stability of the femoral prosthesis after TKA. Finite element analysis (FEA) was used to investigate this question in this study. Methods Four femur models that assembled with TKA femoral components were reconstructed and divided into high BMI group and normal BMI group. The three-dimensional femurs were modeled and assigned inhomogeneous materials based on computed tomography (CT) images. Then each FEA model was applied with gait and deep bend loading conditions to evaluate the maximum principal strain on the distal femur and the relative micromotion between the femur and prosthesis. Results The mean strain of the high BMI group increased by 32.7% (936.9 με versus 706.1 με) and 50.9% (2064.5 με versus 1368.2 με) under gait and deep bend loading conditions, respectively, compared to the normal BMI group. Meanwhile, the mean micromotion of the high BMI group increased by 41.6% (2.77 μm versus 1.96 μm) and 58.5% (62.1 μm versus 39.2 μm), respectively. Under gait condition, the maximum micromotion for high BMI group was 33.8 μm and would compromise the initial stability. Under deep bend condition, the maximum strain and micromotion exceeded -7300 με and 28 μm for both groups. Conclusion High BMI caused higher strain on the bone and higher micromotion between the prosthesis and the femur. Gait activities could be risky for prosthesis stability in high BMI group while be safe in normal group. Deep bend activities were highly dangerous for both groups with high BMI and normal BMI and should be avoided.
Collapse
Affiliation(s)
- Qian Wan
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Aobo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Yang Liu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Hao Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Jiangbo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Haowen Xue
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Qing Han
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Jincheng Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| |
Collapse
|
5
|
Additively manufactured controlled porous orthopedic joint replacement designs to reduce bone stress shielding: a systematic review. J Orthop Surg Res 2023; 18:42. [PMID: 36647070 PMCID: PMC9841707 DOI: 10.1186/s13018-022-03492-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 12/30/2022] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND Total joint replacements are an established treatment for patients suffering from reduced mobility and pain due to severe joint damage. Aseptic loosening due to stress shielding is currently one of the main reasons for revision surgery. As this phenomenon is related to a mismatch in mechanical properties between implant and bone, stiffness reduction of implants has been of major interest in new implant designs. Facilitated by modern additive manufacturing technologies, the introduction of porosity into implant materials has been shown to enable significant stiffness reduction; however, whether these devices mitigate stress-shielding associated complications or device failure remains poorly understood. METHODS In this systematic review, a broad literature search was conducted in six databases (Scopus, Web of Science, Medline, Embase, Compendex, and Inspec) aiming to identify current design approaches to target stress shielding through controlled porous structures. The search keywords included 'lattice,' 'implant,' 'additive manufacturing,' and 'stress shielding.' RESULTS After the screening of 2530 articles, a total of 46 studies were included in this review. Studies focusing on hip, knee, and shoulder replacements were found. Three porous design strategies were identified, specifically uniform, graded, and optimized designs. The latter included personalized design approaches targeting stress shielding based on patient-specific data. All studies reported a reduction of stress shielding achieved by the presented design. CONCLUSION Not all studies used quantitative measures to describe the improvements, and the main stress shielding measures chosen varied between studies. However, due to the nature of the optimization approaches, optimized designs were found to be the most promising. Besides the stiffness reduction, other factors such as mechanical strength can be considered in the design on a patient-specific level. While it was found that controlled porous designs are overall promising to reduce stress shielding, further research and clinical evidence are needed to determine the most superior design approach for total joint replacement implants.
Collapse
|
6
|
Xue H, Bai H, Zhou R, Wang J, Zhou B, Wang X, Luo W, Zhao X. Novel Design of the Compound Sleeve and Stem Prosthesis for Treatment of Proximal Femur Bone Defects Based on Topology Optimization. Front Bioeng Biotechnol 2022; 10:938337. [PMID: 35813996 PMCID: PMC9263260 DOI: 10.3389/fbioe.2022.938337] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Accepted: 06/01/2022] [Indexed: 11/13/2022] Open
Abstract
The loosening of traditional prosthetics is among the leading causes of surgical failure of proximal femoral bone defects. A novel compound sleeve and stem prosthesis was designed using an optimization methodology that combined an octet-truss porous structure with density-based topology optimization to improve stability, promote bone ingrowth, and enhance biomechanical properties. Biomechanical changes were assessed using finite element analysis. The distribution of stress, the strain energy density, and the relative micromotion in the optimized group were considered. The optimized sleeve prosthesis achieved a 31.5% weight reduction. The maximum stresses in the optimized group were observed to decrease by 30.33 and 4.74% at the back sleeve and neck part of stem prosthesis, with a 29.52% increase in the femur, respectively. The average stress in most selected regions in the optimized group was significantly greater than that in the original group (p < 0.05). The maximum relative micromotion decreased by 15.18% (from 63.9 to 54.2 μm) in the optimized group. The novel designed compound sleeve and stem prosthesis could effectively improve the biomechanical performance of next-generation prosthetics and provide a microenvironment for bone ingrowth. The presented method could serve as a model for clinical practice and a platform for future orthopedic surgery applications.
Collapse
Affiliation(s)
- Haowen Xue
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Haotian Bai
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Rongqi Zhou
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Jincheng Wang
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Bin Zhou
- The Second Clinical Medical College, Jilin University, Changchun, China
| | - Xiaonan Wang
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Wenbin Luo
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Xin Zhao
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
- *Correspondence: Xin Zhao,
| |
Collapse
|
7
|
Zhou R, Xue H, Wang J, Wang X, Wang Y, Zhang A, Zhang J, Han Q, Zhao X. Improving the Stability of a Hemipelvic Prosthesis Based on Bone Mineral Density Screw Channel and Prosthesis Optimization Design. Front Bioeng Biotechnol 2022; 10:892385. [PMID: 35706507 PMCID: PMC9189365 DOI: 10.3389/fbioe.2022.892385] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 05/16/2022] [Indexed: 11/13/2022] Open
Abstract
In pelvic reconstruction surgery, the hemipelvic prosthesis can cause significant changes in stress distribution due to its high stiffness, and its solid structure is not suitable for osseointegration. The purpose of this study was to identify a novel bone mineral density screw channel and design the structure of the prosthesis so as to improve the distribution of stress, promote bone growth, and enhance the biomechanical properties of the prosthesis. The mechanical characteristics of bone mineral density screw and traditional screw were compared by finite element analysis method, and redesigned by topology optimization. The direction of the newly proposed screw channel was the posterolateral entrance of the auricular surface, ending at the contralateral sacral cape. Compared to the original group, the maximum stress of the optimized prosthesis was decreased by 24.39%, the maximum stress of the sacrum in the optimized group was decreased by 27.23%, and the average strain energy density of the sacrum in the optimized group was increased by 8.43%. On the surface of screw and connecting plate, the area with micromotion more than 28 μm is reduced by 12.17%. On the screw surface, the area with micromotion more than 28 μm is reduced by 22.9%. The newly determined screw channel and optimized prosthesis design can effectively improve the biomechanical properties of a prosthesis and the microenvironment of osseointegration. This method can provide a reference for the fixation of prostheses in clinical pelvic reconstruction.
Collapse
|