1
|
Kong Q, Li F, Yan C, Sun J, Sun P, Ou‐Yang J, Zhong S, Wang Y, Shi J. Biomechanical Comparison of Anterior Cervical Corpectomy Decompression and Fusion, Anterior Cervical Discectomy and Fusion, and Anterior Controllable Antedisplacement and Fusion in the Surgical Treatment of Multilevel Cervical Spondylotic Myelopathy: A Finite Element Analysis. Orthop Surg 2024; 16:687-699. [PMID: 38316415 PMCID: PMC10925493 DOI: 10.1111/os.13994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 12/19/2023] [Accepted: 12/20/2023] [Indexed: 02/07/2024] Open
Abstract
PURPOSE Multilevel cervical spondylotic myelopathy poses significant challenges in selecting optimal surgical approaches, warranting a comprehensive understanding of their biomechanical impacts. Given the lack of consensus regarding the most effective technique, this study aims to fill this critical knowledge gap by rigorously assessing and comparing the biomechanical properties of three distinct surgical interventions, including anterior controllable antedisplacement and fusion (ACAF), anterior cervical corpectomy decompression and fusion (ACCF), and anterior cervical discectomy and fusion (ACDF). The study offers pivotal insights to enhance treatment precision and patient outcomes. METHODS The construction of the cervical spine model involved a detailed process using CT data, specialized software (Mimics, Geomagic Studio, and Hypermesh) and material properties obtained from prior studies. Surgical instruments were modeled (titanium mesh, anterior cervical plate, interbody cage, and self-tapping screws) to simulate three surgical approaches: ACAF, ACCF, and ACDF, each with specific procedures replicating clinical protocols. A 75-N follower load with 2 Nm was applied to simulate biomechanical effects. RESULTS The range of motion decreased more after surgery for ACAF and ACDF than for ACCF, especially in flexion and lateral bending. ACCF have higher stress peaks in the fixation system than those of ACAF and ACDF, especially in flexion. The maximum von Mises stresses of the bone-screw interfaces at C3 of ACCF were higher than those of ACAF and ACDF. The maximum von Mises stresses of the bone-screw interfaces at C6 of ACDF were much higher than those of ACAF and ACCF. The maximum von Mises stresses of the grafts of ACCF and ACAF were much higher than those of ACDF. The maximum von Mises stresses of the endplate of ACCF were much higher than those of ACAF and ACDF. CONCLUSION The ACAF and ACDF models demonstrated superior cervical reconstruction stability over the ACCF model. ACAF exhibited lower risks of internal fixation failure and cage subsidence compared to ACCF, making it a promising approach. However, while ACAF revealed improved stability over ACCF, higher rates of subsidence and internal fixation failure persisted compared to ACDF, suggesting the need for further exploration of ACAF's long-term efficacy and potential improvements in clinical outcomes.
Collapse
Affiliation(s)
- Qingjie Kong
- Department of Orthopedics, Shanghai General HospitalShanghai Jiao Tong University School of MedicineShanghaiChina
| | - Fudong Li
- Department of Orthopedic Surgery, Spine Center, Shanghai Changzheng HospitalSecond Military Medical UniversityShanghaiChina
| | - Chen Yan
- Department of Orthopedic Surgery, Spine Center, Shanghai Changzheng HospitalSecond Military Medical UniversityShanghaiChina
| | - Jingchuan Sun
- Department of Orthopedic Surgery, Spine Center, Shanghai Changzheng HospitalSecond Military Medical UniversityShanghaiChina
| | - Peidong Sun
- Guangdong Provincial Key Laboratory of Medical Biomechanics, Department of AnatomySouthern Medical UniversityGuangzhouChina
| | - Jun Ou‐Yang
- Department of Orthopedic Surgery, Spine Center, Shanghai Changzheng HospitalSecond Military Medical UniversityShanghaiChina
| | - Shizhen Zhong
- Guangdong Provincial Key Laboratory of Medical Biomechanics, Department of AnatomySouthern Medical UniversityGuangzhouChina
| | - Yuan Wang
- Department of Orthopedic Surgery, Spine Center, Shanghai Changzheng HospitalSecond Military Medical UniversityShanghaiChina
| | - Jiangang Shi
- Department of Orthopedic Surgery, Spine Center, Shanghai Changzheng HospitalSecond Military Medical UniversityShanghaiChina
| |
Collapse
|
2
|
Ye S, Ye J, Hou Z, You X, Shen S, Zhang J, Yu L, Gu Y, Wang W, Zhao L. Biomechanical study of anterior transpedicular root screw intervertebral fusion system of lower cervical spine: a finite element analysis. Front Bioeng Biotechnol 2024; 12:1352996. [PMID: 38357708 PMCID: PMC10865374 DOI: 10.3389/fbioe.2024.1352996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2023] [Accepted: 01/18/2024] [Indexed: 02/16/2024] Open
Abstract
Background: The cervical anterior transpedicular screw (ATPS) fixation technology can provide adequate stability for cervical three-column injuries. However, its high risk of screw insertion and technical complexity have restricted its widespread clinical application. As an improvement over the ATPS technology, the cervical anterior transpedicular root screw (ATPRS) technology has been introduced to reduce the risk associated with screw insertion. This study aims to use finite element analysis (FEA) to investigate the biomechanical characteristics of a cervical spine model after using the novel ATPRS intervertebral fusion system, providing insights into its application and potential refinement. Methods: A finite element (FE) model of the C3-C7 lower cervical spine was established and validated. After two-level (C4-C6) anterior cervical discectomy and fusion (ACDF) surgery, FE models were constructed for the anterior cervical locked-plate (ACLP) internal fixation, the ATPS internal fixation, and the novel ATPRS intervertebral fusion system. These models were subjected to 75N axial force and 1.0 Nm to induce various movements. The range of motion (ROM) of the surgical segments (C4-C6), maximum stress on the internal fixation systems, and maximum stress on the adjacent intervertebral discs were tested and recorded. Results: All three internal fixation methods effectively reduced the ROM of the surgical segments. The ATPRS model demonstrated the smallest ROM during flexion, extension, and rotation, but a slightly larger ROM during lateral bending. Additionally, the maximum bone-screw interface stresses for the ATPRS model during flexion, extension, lateral bending, and axial rotation were 32.69, 64.24, 44.07, 35.89 MPa, which were lower than those of the ACLP and ATPS models. Similarly, the maximum stresses on the adjacent intervertebral discs in the ATPRS model during flexion, extension, lateral bending, and axial rotation consistently remained lower than those in the ACLP and ATPS models. However, the maximum stresses on the cage and the upper endplate of the ATPRS model were generally higher. Conclusion: Although the novel ATPRS intervertebral fusion system generally had greater endplate stress than ACLP and ATPS, it can better stabilize cervical three-column injuries and might reduce the occurrence of adjacent segment degeneration (ASD). Furthermore, further studies and improvements are necessary for the ATPRS intervertebral fusion system.
Collapse
Affiliation(s)
- Senqi Ye
- Department of Spinal Surgery, Yuyao People’s Hospital, Yuyao, China
| | - Jiachun Ye
- The Affiliated Lihuili Hospital, Ningbo University, Ningbo, China
| | - Zhipeng Hou
- Health Science Center, Ningbo University, Ningbo, China
| | - Xinmao You
- Department of Spinal Surgery, Yuyao People’s Hospital, Yuyao, China
| | - Shufeng Shen
- Department of Spinal Surgery, Yuyao People’s Hospital, Yuyao, China
| | - Jihui Zhang
- Department of Spinal Surgery, Ningbo No 6.Hospital of Ningbo University, Ningbo, China
| | - Liang Yu
- Department of Spinal Surgery, Ningbo No 6.Hospital of Ningbo University, Ningbo, China
| | - Yongjie Gu
- Department of Spinal Surgery, Ningbo No 6.Hospital of Ningbo University, Ningbo, China
| | - Wei Wang
- Urumqi DW Innovation Infotech Co., Ltd., Urumqi, Xinjiang, China
| | - Liujun Zhao
- Department of Spinal Surgery, Ningbo No 6.Hospital of Ningbo University, Ningbo, China
| |
Collapse
|
3
|
Xu Z, Li Y, Huang W, Wang Z, Xu X, Tian S. Preliminary exploration of the biomechanical properties of three novel cervical porous fusion cages using a finite element study. BMC Musculoskelet Disord 2023; 24:876. [PMID: 37950220 PMCID: PMC10636970 DOI: 10.1186/s12891-023-06999-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 10/29/2023] [Indexed: 11/12/2023] Open
Abstract
BACKGROUND Porous cages are considered a promising alternative to high-density cages because their interconnectivity favours bony ingrowth and appropriate stiffness tuning reduces stress shielding and the risk of cage subsidence. METHODS This study proposes three approaches that combine macroscopic topology optimization and micropore design to establish three new types of porous cages by integrating lattices (gyroid, Schwarz, body-centred cubic) with the optimized cage frame. Using these three porous cages along with traditional high-density cages, four ACDF surgical models were developed to compare the mechanical properties of facet articular cartilage, discs, cortical bone, and cages under specific loads. RESULTS The facet joints in the porous cage groups had lower contact forces than those in the high-density cage group. The intervertebral discs in all models experienced maximum stress at the C5/6 segment. The stress distribution on the cortical bone surface was more uniform in the porous cage groups, leading to increased average stress values. The gyroid, Schwarz, and BCC cage groups showed higher average stress on the C5 cortical bone. The average stress on the surface of porous cages was higher than that on the surface of high-density cages, with the greatest difference observed under the lateral bending condition. The BCC cage demonstrated favourable mechanical stability. CONCLUSION The new porous cervical cages satifies requirements of low rigidity and serve as a favourable biological scaffold for bone ingrowth. This study provides valuable insights for the development of next-generation orthopaedic medical devices.
Collapse
Affiliation(s)
- Zhi Xu
- Department of Orthopedic, Zhangjiagang Fifth People's Hospital, Zhangjiagang, 215600, Jiangsu, China.
| | - Yuwan Li
- Department of Orthopedic, Peking University Third Hospital, Beijing, 100191, China
- Department of Orthopedic, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310000, China
| | - Weijun Huang
- Department of Orthopedic, Shangyu Third Hospital, Shangyu, 312300, Zhejiang, China
| | - Ziru Wang
- Clinical Medical College, Wannan Medical College, Wuhu, 241000, Anhui, China
- Department of Orthopedic, The First Affiliated Hospital of Wannan Medical College, Wuhu, 241000, Anhui, China
| | - Xing Xu
- Department of Medicine, Zhijin People's Hospital, Zhijin, 552100, Guizhou, China
| | - Shoujin Tian
- Department of Orthopedic, Zhangjiagang First People's Hospital, Zhangjiagang, 215600, Jiangsu, China.
| |
Collapse
|
4
|
Shang P, Ma B, Hou G, Zhang Y, Cui L, Song W, Liu Y. A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement. J Orthop Surg Res 2023; 18:828. [PMID: 37924130 PMCID: PMC10623881 DOI: 10.1186/s13018-023-04310-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 10/22/2023] [Indexed: 11/06/2023] Open
Abstract
BACKGROUND Prosthesis subsidence and mechanical failure were considered significant threats after vertebral body replacement during the long-term follow-up. Therefore, improving and optimizing the structure of vertebral substitutes for exceptional performance has become a pivotal challenge in spinal reconstruction. METHODS The study aimed to develop a novel artificial vertebral implant (AVI) with triply periodic minimal surface Gyroid porous structures to enhance the safety and stability of prostheses. The biomechanical performance of AVIs under different loading conditions was analyzed using the finite element method. These implants were fabricated using selective laser melting technology and evaluated through static compression and subsidence experiments. RESULTS The results demonstrated that the peak stress in the Gyroid porous AVI was consistently lower than that in the traditional porous AVI under all loading conditions, with a maximum reduction of 73.4%. Additionally, it effectively reduced peak stress at the bone-implant interface of the vertebrae. Static compression experiments demonstrated that the Gyroid porous AVI was about 1.63 times to traditional porous AVI in terms of the maximum compression load, indicating that Gyroid porous AVI could meet the safety requirement. Furthermore, static subsidence experiments revealed that the subsidence tendency of Gyroid porous AVI in polyurethane foam (simulated cancellous bone) was approximately 15.7% lower than that of traditional porous AVI. CONCLUSIONS The Gyroid porous AVI exhibited higher compressive strength and lower subsidence tendency than the strut-based traditional porous AVI, indicating it may be a promising substitute for spinal reconstruction.
Collapse
Affiliation(s)
- Peng Shang
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China.
| | - Benyuan Ma
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Guanghui Hou
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Yihai Zhang
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Lunxu Cui
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Wanzhen Song
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Yancheng Liu
- Department of Bone and Soft Tissue Oncology, Tianjin Hospital, Tianjin, China.
| |
Collapse
|
5
|
Wang Y, Liu Y, Zhang A, Han Q, Jiao J, Chen H, Gong X, Luo W, Yue J, Zhao X, Wang J, Wu M. Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis. Front Bioeng Biotechnol 2023; 11:1229210. [PMID: 37744254 PMCID: PMC10512836 DOI: 10.3389/fbioe.2023.1229210] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 08/14/2023] [Indexed: 09/26/2023] Open
Abstract
Introduction: Anterior cervical discectomy and fusion (ACDF) is a standard procedure for treating symptomatic cervical degenerative disease. The cage and plate constructs (CPCs) are widely employed in ACDF to maintain spinal stability and to provide immediate support. However, several instrument-related complications such as dysphagia, cage subsidence, and adjacent segment degeneration have been reported in the previous literature. This study aimed to design a novel individualized zero-profile (NIZP) cage and evaluate its potential to enhance the biomechanical performance between the instrument and the cervical spine. Methods: The intact finite element models of C3-C7 were constructed and validated. A NIZP cage was designed based on the anatomical parameters of the subject's C5/6. The ACDF procedure was simulated and the CPCs and NIZP cage were implanted separately. The range of motion (ROM), intradiscal pressure (IDP), and peak von Mises stresses of annulus fibrosus were compared between the two surgical models after ACDF under four motion conditions. Additionally, the biomechanical performance of the CPCs and NIZP cage were evaluated. Results: Compared with the intact model, the ROM of the surgical segment was significantly decreased for both surgical models under four motion conditions. Additionally, there was an increase in IDP and peak von Mises stress of annulus fibrosus in the adjacent segment. The NIZP cage had a more subtle impact on postoperative IDP and peak von Mises stress of annulus fibrosus in adjacent segments compared to CPCs. Meanwhile, the peak von Mises stresses of the NIZP cage were reduced by 90.0-120.0 MPa, and the average von Mises stresses were reduced by 12.61-17.56 MPa under different motion conditions. Regarding the fixation screws, the peak von Mises stresses in the screws of the NIZP cage increased by 10.0-40.0 MPa and the average von Mises stresses increased by 2.37-10.10 MPa. Conclusion: The NIZP cage could effectively reconstruct spinal stability in ACDF procedure by finite element study. Compared with the CPCs, the NIZP cage had better biomechanical performance, with a lower stress distribution on the cage and a more moderate effect on the adjacent segmental discs. Therefore, the NIZP cage could prevent postoperative dysphagia as well as decrease the risk of subsidence and adjacent disc degeneration following ACDF. In addition, this study could serve as a valuable reference for the development of personalized instruments.
Collapse
Affiliation(s)
- Yang Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Yang Liu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Aobo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Qing Han
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Jianhang Jiao
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Hao Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Xuqiang Gong
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Wangwang Luo
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Jing Yue
- Department of Anesthesiology, The Second Hospital of Jilin University, Changchun, China
| | - Xue Zhao
- Department of Endocrinology and Metabolism, First Hospital of Jilin University, Changchun, China
| | - Jincheng Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Minfei Wu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| |
Collapse
|
6
|
Zhang X, Yang Y, Shen YW, Zhang KR, Ma LT, Ding C, Wang BY, Meng Y, Liu H. Biomechanical performance of the novel assembled uncovertebral joint fusion cage in single-level anterior cervical discectomy and fusion: A finite element analysis. Front Bioeng Biotechnol 2023; 11:931202. [PMID: 36970630 PMCID: PMC10031026 DOI: 10.3389/fbioe.2023.931202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 02/22/2023] [Indexed: 03/11/2023] Open
Abstract
Introduction: Anterior cervical discectomy and fusion (ACDF) is widely accepted as the gold standard surgical procedure for treating cervical radiculopathy and myelopathy. However, there is concern about the low fusion rate in the early period after ACDF surgery using the Zero-P fusion cage. We creatively designed an assembled uncoupled joint fusion device to improve the fusion rate and solve the implantation difficulties. This study aimed to assess the biomechanical performance of the assembled uncovertebral joint fusion cage in single-level ACDF and compare it with the Zero-P device.Methods: A three-dimensional finite element (FE) of a healthy cervical spine (C2−C7) was constructed and validated. In the one-level surgery model, either an assembled uncovertebral joint fusion cage or a zero-profile device was implanted at the C5–C6 segment of the model. A pure moment of 1.0 Nm combined with a follower load of 75 N was imposed at C2 to determine flexion, extension, lateral bending, and axial rotation. The segmental range of motion (ROM), facet contact force (FCF), maximum intradiscal pressure (IDP), and screw−bone stress were determined and compared with those of the zero-profile device.Results: The results showed that the ROMs of the fused levels in both models were nearly zero, while the motions of the unfused segments were unevenly increased. The FCF at adjacent segments in the assembled uncovertebral joint fusion cage group was less than that that of the Zero-P group. The IDP at the adjacent segments and screw–bone stress were slightly higher in the assembled uncovertebral joint fusion cage group than in those of the Zero-P group. Stress on the cage was mainly concentrated on both sides of the wings, reaching 13.4–20.4 Mpa in the assembled uncovertebral joint fusion cage group.Conclusion: The assembled uncovertebral joint fusion cage provided strong immobilization, similar to the Zero-P device. When compared with the Zero-P group, the assembled uncovertebral joint fusion cage achieved similar resultant values regarding FCF, IDP, and screw–bone stress. Moreover, the assembled uncovertebral joint fusion cage effectively achieved early bone formation and fusion, probably due to proper stress distributions in the wings of both sides.
Collapse
|