1
|
Ao D, Fregly BJ. Comparison of synergy extrapolation and static optimization for estimating multiple unmeasured muscle activations during walking. J Neuroeng Rehabil 2024; 21:194. [PMID: 39482723 PMCID: PMC11529311 DOI: 10.1186/s12984-024-01490-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 10/15/2024] [Indexed: 11/03/2024] Open
Abstract
BACKGROUND Calibrated electromyography (EMG)-driven musculoskeletal models can provide insight into internal quantities (e.g., muscle forces) that are difficult or impossible to measure experimentally. However, the need for EMG data from all involved muscles presents a significant barrier to the widespread application of EMG-driven modeling methods. Synergy extrapolation (SynX) is a computational method that can estimate a single missing EMG signal with reasonable accuracy during the EMG-driven model calibration process, yet its performance in estimating a larger number of missing EMG signals remains unknown. METHODS This study assessed the accuracy with which SynX can use eight measured EMG signals to estimate muscle activations and forces associated with eight missing EMG signals in the same leg during walking while simultaneously performing EMG-driven model calibration. Experimental gait data collected from two individuals post-stroke, including 16 channels of EMG data per leg, were used to calibrate an EMG-driven musculoskeletal model, providing "gold standard" muscle activations and forces for evaluation purposes. SynX was then used to predict the muscle activations and forces associated with the eight missing EMG signals while simultaneously calibrating EMG-driven model parameter values. Due to its widespread use, static optimization (SO) applied to a scaled generic musculoskeletal model was also utilized to estimate the same muscle activations and forces. Estimation accuracy for SynX and SO was evaluated using root mean square errors (RMSE) to quantify amplitude errors and correlation coefficient r values to quantify shape similarity, each calculated with respect to "gold standard" muscle activations and forces. RESULTS On average, compared to SO, SynX with simultaneous model calibration produced significantly more accurate amplitude and shape estimates for unmeasured muscle activations (RMSE 0.08 vs. 0.15, r value 0.55 vs. 0.12) and forces (RMSE 101.3 N vs. 174.4 N, r value 0.53 vs. 0.07). SynX yielded calibrated Hill-type muscle-tendon model parameter values for all muscles and activation dynamics model parameter values for measured muscles that were similar to "gold standard" calibrated model parameter values. CONCLUSIONS These findings suggest that SynX could make it possible to calibrate EMG-driven musculoskeletal models for all important lower-extremity muscles with as few as eight carefully chosen EMG signals and eventually contribute to the design of personalized rehabilitation and surgical interventions for mobility impairments.
Collapse
Affiliation(s)
- Di Ao
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, Shaanxi, China.
| | - Benjamin J Fregly
- Department for Mechanical Engineering, Rice University, Houston, TX, USA
| |
Collapse
|
2
|
Zhu Y, Babazadeh-Naseri A, Brake MRW, Akin JE, Li G, Lewis VO, Fregly BJ. Evaluation of finite element modeling methods for predicting compression screw failure in a custom pelvic implant. Front Bioeng Biotechnol 2024; 12:1420870. [PMID: 39234264 PMCID: PMC11372789 DOI: 10.3389/fbioe.2024.1420870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2024] [Accepted: 08/05/2024] [Indexed: 09/06/2024] Open
Abstract
Introduction: Three-dimensional (3D)-printed custom pelvic implants have become a clinically viable option for patients undergoing pelvic cancer surgery with resection of the hip joint. However, increased clinical utilization has also necessitated improved implant durability, especially with regard to the compression screws used to secure the implant to remaining pelvic bone. This study evaluated six different finite element (FE) screw modeling methods for predicting compression screw pullout and fatigue failure in a custom pelvic implant secured to bone using nine compression screws. Methods: Three modeling methods (tied constraints (TIE), bolt load with constant force (BL-CF), and bolt load with constant length (BL-CL)) generated screw axial forces using functionality built into Abaqus FE software; while the remaining three modeling methods (isotropic pseudo-thermal field (ISO), orthotropic pseudo-thermal field (ORT), and equal-and-opposite force field (FOR)) generated screw axial forces using iterative physics-based relationships that can be implemented in any FE software. The ability of all six modeling methods to match specified screw pretension forces and predict screw pullout and fatigue failure was evaluated using an FE model of a custom pelvic implant with total hip replacement. The applied hip contact forces in the FE model were estimated at two locations in a gait cycle. For each of the nine screws in the custom implant FE model, likelihood of screw pullout failure was predicted using maximum screw axial force, while likelihood of screw fatigue failure was predicted using maximum von Mises stress. Results: The three iterative physics-based modeling methods and the non-iterative Abaqus BL-CL method produced nearly identical predictions for likelihood of screw pullout and fatigue failure, while the other two built-in Abaqus modeling methods yielded vastly different predictions. However, the Abaqus BL-CL method required the least computation time, largely because an iterative process was not needed to induce specified screw pretension forces. Of the three iterative methods, FOR required the fewest iterations and thus the least computation time. Discussion: These findings suggest that the BL-CL screw modeling method is the best option when Abaqus is used for predicting screw pullout and fatigue failure in custom pelvis prostheses, while the iterative physics-based FOR method is the best option if FE software other than Abaqus is used.
Collapse
Affiliation(s)
- Yuhui Zhu
- Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Ata Babazadeh-Naseri
- Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Matthew R W Brake
- Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - John E Akin
- Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Geng Li
- Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Valerae O Lewis
- Department of Orthopedic Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Benjamin J Fregly
- Department of Mechanical Engineering, Rice University, Houston, TX, United States
| |
Collapse
|
3
|
Wang Z, Guan X, He L, Zhu M, Bai Y. Positional Analysis of Assisting Muscles for Handling-Assisted Exoskeletons. SENSORS (BASEL, SWITZERLAND) 2024; 24:4673. [PMID: 39066070 PMCID: PMC11280825 DOI: 10.3390/s24144673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 07/16/2024] [Accepted: 07/16/2024] [Indexed: 07/28/2024]
Abstract
In order to better design handling-assisted exoskeletons, it is necessary to analyze the biomechanics of human hand movements. In this study, Anybody Modeling System (AMS) simulation was used to analyze the movement state of muscles during human handling. Combined with surface electromyography (sEMG) experiments, specific analysis and verification were carried out to obtain the position of muscles that the human body needs to assist during handling. In this study, the simulation and experiment were carried out for the manual handling process. A treatment group and an experimental group were set up. This study found that the vastus medialis muscle, vastus lateralis muscle, latissimus dorsi muscle, trapezius muscle, deltoid muscle and triceps brachii muscle require more energy in the process of handling, and it is reasonable and effective to combine sEMG signals with the simulation of the musculoskeletal model to analyze the muscle condition of human movement.
Collapse
Affiliation(s)
- Zheng Wang
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China; (Z.W.); (L.H.); (M.Z.); (Y.B.)
| | - Xiaorong Guan
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China; (Z.W.); (L.H.); (M.Z.); (Y.B.)
| | - Long He
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China; (Z.W.); (L.H.); (M.Z.); (Y.B.)
- Zhiyuan Research Institute, Hangzhou 310000, China
| | - Meng Zhu
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China; (Z.W.); (L.H.); (M.Z.); (Y.B.)
| | - Yu Bai
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China; (Z.W.); (L.H.); (M.Z.); (Y.B.)
| |
Collapse
|
4
|
Xiao Z, Li C, Wang X, Guo J, Tian Q. Muscle Strength Identification Based on Isokinetic Testing and Spine Musculoskeletal Modeling. CYBORG AND BIONIC SYSTEMS 2024; 5:0113. [PMID: 39040710 PMCID: PMC11261815 DOI: 10.34133/cbsystems.0113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Accepted: 03/15/2024] [Indexed: 07/24/2024] Open
Abstract
Subject-specific spinal musculoskeletal modeling can help understand the spinal loading mechanism during human locomotion. However, existing literature lacks methods to identify the maximum isometric strength of individual spinal muscles. In this study, a muscle strength identification method combining isokinetic testing and musculoskeletal simulations was proposed, and the influence of muscle synergy and intra-abdominal pressure (IAP) on identified spinal muscle strength was further discussed. A multibody dynamic model of the spinal musculoskeletal system was established and controlled by a feedback controller. Muscle strength parameters were adjusted based on the measured isokinetic moments, and muscle synergy vectors and the IAP piston model were further introduced. The results of five healthy subjects showed that the proposed method successfully identified the subject-specific spinal flexor/extensor strength. Considering the synergistic activations of antagonist muscles improved the correlation between the simulated and measured spinal moments, and the introduction of IAP slightly increased the identified spinal extensor strength. The established method is beneficial for understanding spinal loading distributions for athletes and patients with sarcopenia.
Collapse
Affiliation(s)
- Zuming Xiao
- MOE Key Laboratory of Dynamics and Control of Flight Vehicle, School of Aerospace Engineering, Beijing Institute of Technology, Beijing, China
| | - Chang Li
- Professional and Technical Innovation Center for Exercise Diagnosis and Evaluation, Shenyang Sport University, Shenyang, China
| | - Xin Wang
- Professional and Technical Innovation Center for Exercise Diagnosis and Evaluation, Shenyang Sport University, Shenyang, China
| | - Jianqiao Guo
- MOE Key Laboratory of Dynamics and Control of Flight Vehicle, School of Aerospace Engineering, Beijing Institute of Technology, Beijing, China
| | - Qiang Tian
- MOE Key Laboratory of Dynamics and Control of Flight Vehicle, School of Aerospace Engineering, Beijing Institute of Technology, Beijing, China
| |
Collapse
|
5
|
Li G, Ao D, Vega MM, Zandiyeh P, Chang SH, Penny AN, Lewis VO, Fregly BJ. Changes in walking function and neural control following pelvic cancer surgery with reconstruction. Front Bioeng Biotechnol 2024; 12:1389031. [PMID: 38827035 PMCID: PMC11140731 DOI: 10.3389/fbioe.2024.1389031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 04/15/2024] [Indexed: 06/04/2024] Open
Abstract
Introduction: Surgical planning and custom prosthesis design for pelvic cancer patients are challenging due to the unique clinical characteristics of each patient and the significant amount of pelvic bone and hip musculature often removed. Limb-sparing internal hemipelvectomy surgery with custom prosthesis reconstruction has become a viable option for this patient population. However, little is known about how post-surgery walking function and neural control change from pre-surgery conditions. Methods: This case study combined comprehensive walking data (video motion capture, ground reaction, and electromyography) with personalized neuromusculoskeletal computer models to provide a thorough assessment of pre- to post-surgery changes in walking function (ground reactions, joint motions, and joint moments) and neural control (muscle synergies) for a single pelvic sarcoma patient who received internal hemipelvectomy surgery with custom prosthesis reconstruction. Pre- and post-surgery walking function and neural control were quantified using pre- and post-surgery neuromusculoskeletal models, respectively, whose pelvic anatomy, joint functional axes, muscle-tendon properties, and muscle synergy controls were personalized using the participant's pre-and post-surgery walking and imaging data. For the post-surgery model, virtual surgery was performed to emulate the implemented surgical decisions, including removal of hip muscles and implantation of a custom prosthesis with total hip replacement. Results: The participant's post-surgery walking function was marked by a slower self-selected walking speed coupled with several compensatory mechanisms necessitated by lost or impaired hip muscle function, while the participant's post-surgery neural control demonstrated a dramatic change in coordination strategy (as evidenced by modified time-invariant synergy vectors) with little change in recruitment timing (as evidenced by conserved time-varying synergy activations). Furthermore, the participant's post-surgery muscle activations were fitted accurately using his pre-surgery synergy activations but fitted poorly using his pre-surgery synergy vectors. Discussion: These results provide valuable information about which aspects of post-surgery walking function could potentially be improved through modifications to surgical decisions, custom prosthesis design, or rehabilitation protocol, as well as how computational simulations could be formulated to predict post-surgery walking function reliably given a patient's pre-surgery walking data and the planned surgical decisions and custom prosthesis design.
Collapse
Affiliation(s)
- Geng Li
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Di Ao
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Marleny M. Vega
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Payam Zandiyeh
- Biomotion Laboratory, Department of Orthopedic Surgery, McGovern Medical School at the University of Texas Health Science Center at Houston, Houston, TX, United States
| | - Shuo-Hsiu Chang
- Department of Physical Medicine and Rehabilitation, McGovern Medical School at the University of Texas Health Science Center at Houston, Houston, TX, United States
| | - Alexander. N. Penny
- Department of Orthopedic Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Valerae O. Lewis
- Department of Orthopedic Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Benjamin J. Fregly
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| |
Collapse
|
6
|
Di A, Benjamin JF. Comparison of Synergy Extrapolation and Static Optimization for Estimating Multiple Unmeasured Muscle Activations during Walking. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.03.03.583228. [PMID: 38496460 PMCID: PMC10942366 DOI: 10.1101/2024.03.03.583228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/19/2024]
Abstract
Background Calibrated electromyography (EMG)-driven musculoskeletal models can provide great insight into internal quantities (e.g., muscle forces) that are difficult or impossible to measure experimentally. However, the need for EMG data from all involved muscles presents a significant barrier to the widespread application of EMG-driven modeling methods. Synergy extrapolation (SynX) is a computational method that can estimate a single missing EMG signal with reasonable accuracy during the EMG-driven model calibration process, yet its performance in estimating a larger number of missing EMG signals remains unclear. Methods This study assessed the accuracy with which SynX can use eight measured EMG signals to estimate muscle activations and forces associated with eight missing EMG signals in the same leg during walking while simultaneously performing EMG-driven model calibration. Experimental gait data collected from two individuals post-stroke, including 16 channels of EMG data per leg, were used to calibrate an EMG-driven musculoskeletal model, providing "gold standard" muscle activations and forces for evaluation purposes. SynX was then used to predict the muscle activations and forces associated with the eight missing EMG signals while simultaneously calibrating EMG-driven model parameter values. Due to its widespread use, static optimization (SO) was also utilized to estimate the same muscle activations and forces. Estimation accuracy for SynX and SO was evaluated using root mean square errors (RMSE) to quantify amplitude errors and correlation coefficient r values to quantify shape similarity, each calculated with respect to "gold standard" muscle activations and forces. Results On average, SynX produced significantly more accurate amplitude and shape estimates for unmeasured muscle activations (RMSE 0.08 vs. 0.15 , r value 0.55 vs. 0.12) and forces (RMSE 101.3 N vs. 174.4 N , r value 0.53 vs. 0.07) compared to SO. SynX yielded calibrated Hill-type muscle-tendon model parameter values for all muscles and activation dynamics model parameter values for measured muscles that were similar to "gold standard" calibrated model parameter values. Conclusions These findings suggest that SynX could make it possible to calibrate EMG-driven musculoskeletal models for all important lower-extremity muscles with as few as eight carefully chosen EMG signals and eventually contribute to the design of personalized rehabilitation and surgical interventions for mobility impairments.
Collapse
Affiliation(s)
- Ao Di
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, Shaanxi, China
| | - J Fregly Benjamin
- Department for Mechanical Engineering, Rice University, Houston, Texas, USA
| |
Collapse
|
7
|
Wang S, Hase K, Funato T. Computational prediction of muscle synergy using a finite element framework for a musculoskeletal model on lower limb. Front Bioeng Biotechnol 2023; 11:1130219. [PMID: 37533695 PMCID: PMC10392837 DOI: 10.3389/fbioe.2023.1130219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 07/03/2023] [Indexed: 08/04/2023] Open
Abstract
Previous studies have demonstrated that the central nervous system activates muscles in module patterns to reduce the complexity needed to control each muscle while producing a movement, which is referred to as muscle synergy. In previous musculoskeletal modeling-based muscle synergy analysis studies, as a result of simplification of the joints, a conventional rigid-body link musculoskeletal model failed to represent the physiological interactions of muscle activation and joint kinematics. However, the interaction between the muscle level and joint level that exists in vivo is an important relationship that influences the biomechanics and neurophysiology of the musculoskeletal system. In the present, a lower limb musculoskeletal model coupling a detailed representation of a joint including complex contact behavior and material representations was used for muscle synergy analysis using a decomposition method of non-negative matrix factorization (NMF). The complexity of the representation of a joint in a musculoskeletal system allows for the investigation of the physiological interactions in vivo on the musculoskeletal system, thereby facilitating the decomposition of the muscle synergy. Results indicated that, the activities of the 20 muscles on the lower limb during the stance phase of gait could be controlled by three muscle synergies, and total variance accounted for by synergies was 86.42%. The characterization of muscle synergy and musculoskeletal biomechanics is consistent with the results, thus explaining the formational mechanism of lower limb motions during gait through the reduction of the dimensions of control issues by muscle synergy and the central nervous system.
Collapse
Affiliation(s)
- Sentong Wang
- Graduate School of Informatics and Engineering, The University of Electro-Communications, Tokyo, Japan
- Graduate School of Systems Design, Tokyo Metropolitan University, Tokyo, Japan
| | - Kazunori Hase
- Faculty of Systems Design, Tokyo Metropolitan University, Tokyo, Japan
| | - Tetsuro Funato
- Graduate School of Informatics and Engineering, The University of Electro-Communications, Tokyo, Japan
| |
Collapse
|
8
|
Li G, Ao D, Vega MM, Shourijeh MS, Zandiyeh P, Chang SH, Lewis VO, Dunbar NJ, Babazadeh-Naseri A, Baines AJ, Fregly BJ. A computational method for estimating trunk muscle activations during gait using lower extremity muscle synergies. Front Bioeng Biotechnol 2022; 10:964359. [PMID: 36582837 PMCID: PMC9792665 DOI: 10.3389/fbioe.2022.964359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 11/21/2022] [Indexed: 12/15/2022] Open
Abstract
One of the surgical treatments for pelvic sarcoma is the restoration of hip function with a custom pelvic prosthesis after cancerous tumor removal. The orthopedic oncologist and orthopedic implant company must make numerous often subjective decisions regarding the design of the pelvic surgery and custom pelvic prosthesis. Using personalized musculoskeletal computer models to predict post-surgery walking function and custom pelvic prosthesis loading is an emerging method for making surgical and custom prosthesis design decisions in a more objective manner. Such predictions would necessitate the estimation of forces generated by muscles spanning the lower trunk and all joints of the lower extremities. However, estimating trunk and leg muscle forces simultaneously during walking based on electromyography (EMG) data remains challenging due to the limited number of EMG channels typically used for measurement of leg muscle activity. This study developed a computational method for estimating unmeasured trunk muscle activations during walking using lower extremity muscle synergies. To facilitate the calibration of an EMG-driven model and the estimation of leg muscle activations, EMG data were collected from each leg. Using non-negative matrix factorization, muscle synergies were extracted from activations of leg muscles. On the basis of previous studies, it was hypothesized that the time-varying synergy activations were shared between the trunk and leg muscles. The synergy weights required to reconstruct the trunk muscle activations were determined through optimization. The accuracy of the synergy-based method was dependent on the number of synergies and optimization formulation. With seven synergies and an increased level of activation minimization, the estimated activations of the erector spinae were strongly correlated with their measured activity. This study created a custom full-body model by combining two existing musculoskeletal models. The model was further modified and heavily personalized to represent various aspects of the pelvic sarcoma patient, all of which contributed to the estimation of trunk muscle activations. This proposed method can facilitate the prediction of post-surgery walking function and pelvic prosthesis loading, as well as provide objective evaluations for surgical and prosthesis design decisions.
Collapse
Affiliation(s)
- Geng Li
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Di Ao
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Marleny M. Vega
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Mohammad S. Shourijeh
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Payam Zandiyeh
- Biomotion Laboratory, Department of Orthopaedic Surgery, McGovern Medical School at the University of Texas Health Science Center at Houston, Houston, TX, United States
| | - Shuo-Hsiu Chang
- Department of Physical Medicine and Rehabilitation, McGovern Medical School at the University of Texas Health Science Center at Houston, Houston, TX, United States,Neurorecovery Research Center, TIRR Memorial Hermann, Houston, TX, United States
| | - Valerae O. Lewis
- Department of Orthopaedic Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Nicholas J. Dunbar
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Ata Babazadeh-Naseri
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Andrew J. Baines
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Benjamin J. Fregly
- Rice Computational Neuromechanics Laboratory, Department of Mechanical Engineering, Rice University, Houston, TX, United States,*Correspondence: Benjamin J. Fregly,
| |
Collapse
|
9
|
Vega MM, Li G, Shourijeh MS, Ao D, Weinschenk RC, Patten C, Font-Llagunes JM, Lewis VO, Fregly BJ. Computational evaluation of psoas muscle influence on walking function following internal hemipelvectomy with reconstruction. Front Bioeng Biotechnol 2022; 10:855870. [PMID: 36246391 PMCID: PMC9559731 DOI: 10.3389/fbioe.2022.855870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Accepted: 09/01/2022] [Indexed: 11/13/2022] Open
Abstract
An emerging option for internal hemipelvectomy surgery is custom prosthesis reconstruction. This option typically recapitulates the resected pelvic bony anatomy with the goal of maximizing post-surgery walking function while minimizing recovery time. However, the current custom prosthesis design process does not account for the patient's post-surgery prosthesis and bone loading patterns, nor can it predict how different surgical or rehabilitation decisions (e.g., retention or removal of the psoas muscle, strengthening the psoas) will affect prosthesis durability and post-surgery walking function. These factors may contribute to the high observed failure rate for custom pelvic prostheses, discouraging orthopedic oncologists from pursuing this valuable treatment option. One possibility for addressing this problem is to simulate the complex interaction between surgical and rehabilitation decisions, post-surgery walking function, and custom pelvic prosthesis design using patient-specific neuromusculoskeletal models. As a first step toward developing this capability, this study used a personalized neuromusculoskeletal model and direct collocation optimal control to predict the impact of ipsilateral psoas muscle strength on walking function following internal hemipelvectomy with custom prosthesis reconstruction. The influence of the psoas muscle was targeted since retention of this important muscle can be surgically demanding for certain tumors, requiring additional time in the operating room. The post-surgery walking predictions emulated the most common surgical scenario encountered at MD Anderson Cancer Center in Houston. Simulated post-surgery psoas strengths included 0% (removed), 50% (weakened), 100% (maintained), and 150% (strengthened) of the pre-surgery value. However, only the 100% and 150% cases successfully converged to a complete gait cycle. When post-surgery psoas strength was maintained, clinical gait features were predicted, including increased stance width, decreased stride length, and increased lumbar bending towards the operated side. Furthermore, when post-surgery psoas strength was increased, stance width and stride length returned to pre-surgery values. These results suggest that retention and strengthening of the psoas muscle on the operated side may be important for maximizing post-surgery walking function. If future studies can validate this computational approach using post-surgery experimental walking data, the approach may eventually influence surgical, rehabilitation, and custom prosthesis design decisions to meet the unique clinical needs of pelvic sarcoma patients.
Collapse
Affiliation(s)
- Marleny M. Vega
- Rice Computational Neuromechanics Lab, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Geng Li
- Rice Computational Neuromechanics Lab, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Mohammad S. Shourijeh
- Rice Computational Neuromechanics Lab, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Di Ao
- Rice Computational Neuromechanics Lab, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| | - Robert C. Weinschenk
- Department of Orthopaedic Surgery, University of Texas Southwestern Medical Center, Dallas, TX, United States
| | - Carolynn Patten
- Biomechanics, Rehabilitation, and Integrative Neuroscience (BRaIN) Lab, UC Davis School of Medicine, Sacramento, CA, United States
- UC Davis Center for Neuroengineering and Medicine, University of California, Davis, CA, United States
- VA Northern California Health Care System, Martinez, CA, United States
| | - Josep M. Font-Llagunes
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Centre for Biomedical Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain
- Health Technologies and Innovation, Institut de Recerca Sant Joan de Déu, Esplugues de Llobregat, Spain
| | - Valerae O. Lewis
- Department of Orthopaedic Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Benjamin J. Fregly
- Rice Computational Neuromechanics Lab, Department of Mechanical Engineering, Rice University, Houston, TX, United States
| |
Collapse
|