1
|
Zeng H, Zhang M, Liu H, Liu J, Zhu L, Feng D, Wang J. Two electrochemiluminescence immunosensors for the sensitive and quantitative detection of the CP4-EPSPS protein in genetically modified crops. Food Chem 2023; 428:136818. [PMID: 37421663 DOI: 10.1016/j.foodchem.2023.136818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 07/02/2023] [Accepted: 07/03/2023] [Indexed: 07/10/2023]
Abstract
Two different models of electrochemiluminescence (ECL) immunosensors for the sensitive and quantitative detection of the CP4-EPSPS protein in genetically modified (GM) crops were proposed in this study. One was a signal-reduced ECL immunosensor based on nitrogen-doped graphene, graphitic carbon nitride and polyamide-amine (GN-PAMAM-g-C3N4) composites as the electrochemically active substance. The other model was a signal-enhanced ECL immunosensor based on a GN-PAMAM modified electrode for the detection of CdSe/ZnS quantum dots (QDs)-labeled antigens. The ECL signal responses of the reduced and enhanced immunosensors linearly decreased as the increase of the soybean RRS and RRS-QDs content in the range of 0.05% to 1.5% and 0.025% to 1.0%, with the limits of detection of 0.03% and 0.01% (S/N = 3), respectively. Both of the ECL immunosensors showed good specificity, stability, accuracy, and reproducibility in the analysis of real samples. The results indicate that the two immunosensors provide an ultra-sensitive and quantitative approach for the determination of the CP4-EPSPS protein. Due to their outstanding performances, the two ECL immunosensors could be useful tools for achieving the effective regulation of GM crops.
Collapse
Affiliation(s)
- Haijuan Zeng
- The Biotechnology Research Institute, Shanghai Academy of Agricultural Sciences, Key Laboratory of Agricultural Genetics and Breeding, Shanghai 201106, China; Crops Ecological Environment Security Inspection and Supervision Center (Shanghai), Ministry of Agriculture and Rural Affairs, Shanghai 201106, China; Shanghai Co-Elite Agricultural Sci-Tech (Group) Co. Ltd., Shanghai 201106, China
| | - Minghao Zhang
- The Biotechnology Research Institute, Shanghai Academy of Agricultural Sciences, Key Laboratory of Agricultural Genetics and Breeding, Shanghai 201106, China; School of Life Science, Yangtze University, Jingzhou 434022, China
| | - Hua Liu
- The Biotechnology Research Institute, Shanghai Academy of Agricultural Sciences, Key Laboratory of Agricultural Genetics and Breeding, Shanghai 201106, China; Crops Ecological Environment Security Inspection and Supervision Center (Shanghai), Ministry of Agriculture and Rural Affairs, Shanghai 201106, China
| | - Juan Liu
- School of Public Health, Academician Workstation, Changsha Medical University, Changsha 410219, China
| | - Lemei Zhu
- School of Public Health, Academician Workstation, Changsha Medical University, Changsha 410219, China
| | - Dongsheng Feng
- Shanghai Center of Agri-Products Quality and Safety, Shanghai 200335, China
| | - Jinbin Wang
- The Biotechnology Research Institute, Shanghai Academy of Agricultural Sciences, Key Laboratory of Agricultural Genetics and Breeding, Shanghai 201106, China; Crops Ecological Environment Security Inspection and Supervision Center (Shanghai), Ministry of Agriculture and Rural Affairs, Shanghai 201106, China.
| |
Collapse
|
2
|
Wang J, Wang Y, Liu H, Hu X, Zhang M, Liu X, Ye H, Zeng H. An ultra-sensitive test strip combining with RPA and CRISPR/Cas12a system for the rapid detection of GM crops. Food Control 2023. [DOI: 10.1016/j.foodcont.2022.109383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
3
|
Police Patil AV, Chuang YS, Li C, Wu CC. Recent Advances in Electrochemical Immunosensors with Nanomaterial Assistance for Signal Amplification. BIOSENSORS 2023; 13:bios13010125. [PMID: 36671960 PMCID: PMC9855954 DOI: 10.3390/bios13010125] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/24/2022] [Accepted: 01/07/2023] [Indexed: 05/31/2023]
Abstract
Electrochemical immunosensors have attracted immense attention due to the ease of mass electrode production and the high compatibility of the miniature electric reader, which is beneficial for developing point-of-care diagnostic devices. Electrochemical immunosensors can be divided into label-free and label-based sensing strategies equipped with potentiometric, amperometric, voltammetric, or impedimetric detectors. Emerging nanomaterials are frequently used on electrochemical immunosensors as a highly rough and conductive interface of the electrodes or on nanocarriers of immobilizing capture antibodies, electroactive mediators, or catalyzers. Adopting nanomaterials can increase immunosensor characteristics with lower detection limits and better sensitivity. Recent research has shown innovative immobilization procedures of nanomaterials which meet the requirements of different electrochemical immunosensors. This review discusses the past five years of advances in nanomaterials (metal nanoparticles, metal nanostructures, carbon nanotubes, and graphene) integrated into the electrochemical immunosensor. Furthermore, the new tendency and endeavors of nanomaterial-based electrochemical immunosensors are discussed.
Collapse
Affiliation(s)
- Avinash V. Police Patil
- Department of Bio-Industrial Mechatronics Engineering, National Chung Hsing University, No. 145, Xingda Rd., South Dist., Taichung City 402, Taiwan
| | - Yu-Sheng Chuang
- Department of Bio-Industrial Mechatronics Engineering, National Chung Hsing University, No. 145, Xingda Rd., South Dist., Taichung City 402, Taiwan
| | - Chenzhong Li
- Department of Biochemistry and Molecular Biology, Tulane University, 1324 Tulane Ave., New Orleans, LA 70112, USA
| | - Ching-Chou Wu
- Department of Bio-Industrial Mechatronics Engineering, National Chung Hsing University, No. 145, Xingda Rd., South Dist., Taichung City 402, Taiwan
- Innovation and Development Center of Sustainable Agriculture, National Chung Hsing University, No. 145, Xingda Rd., South Dist., Taichung City 402, Taiwan
| |
Collapse
|
4
|
Zapp E, Brondani D, Silva TR, Girotto E, Gallardo H, Vieira IC. Label-Free Immunosensor Based on Liquid Crystal and Gold Nanoparticles for Cardiac Troponin I Detection. BIOSENSORS 2022; 12:1113. [PMID: 36551080 PMCID: PMC9775587 DOI: 10.3390/bios12121113] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 11/18/2022] [Accepted: 11/25/2022] [Indexed: 06/17/2023]
Abstract
According to the World Health Organization (WHO), cardiovascular diseases (CVDs) are the leading cause of mortality and morbidity worldwide. The development of electrochemical biosensors for CVD markers detection, such as cardiac troponin I (cTnI), becomes an important diagnostic strategy. Thus, a glassy carbon electrode (GCE) was modified with columnar liquid crystal (LCcol) and gold nanoparticles stabilized in polyallylamine hydrochloride (AuNPs-PAH), and the surface was employed to evaluate the interaction of the cTnI antibody (anti-cTnI) and cTnI for detection in blood plasma. Morphological and electrochemical investigations were used in the characterization and optimization of the materials used in the construction of the immunosensor. The specific interaction of cTnI with the surface of the immunosensor containing anti-cTnI was monitored indirectly using a redox probe. The formation of the immunocomplex caused the suppression of the analytical signal, which was observed due to the insulating characteristics of the protein. The cTnI-immunosensor interaction showed linear responses from 0.01 to 0.3 ng mL-1 and a low limit of detection (LOD) of 0.005 ng mL-1 for linear sweep voltammetry (LSV) and 0.01 ng mL-1 for electrochemical impedance spectroscopy (EIS), showing good diagnostic capacity for point-of-care applications.
Collapse
Affiliation(s)
- Eduardo Zapp
- Department of Exact Science and Education, Federal University of Santa Catarina, Campus Blumenau, Blumenau 89036-256, Brazil
| | - Daniela Brondani
- Department of Exact Science and Education, Federal University of Santa Catarina, Campus Blumenau, Blumenau 89036-256, Brazil
| | - Tânia Regina Silva
- Department of Chemistry, Federal University of Santa Catarina, Florianópolis 88040-900, Brazil
| | - Edivandro Girotto
- Department of Chemistry, Federal University of Santa Catarina, Florianópolis 88040-900, Brazil
| | - Hugo Gallardo
- Department of Chemistry, Federal University of Santa Catarina, Florianópolis 88040-900, Brazil
| | - Iolanda Cruz Vieira
- Department of Chemistry, Federal University of Santa Catarina, Florianópolis 88040-900, Brazil
| |
Collapse
|