1
|
Alwael H, Al-Raimi DS, Al-Ahmary KM, Nasef HA, Alharthi AS, Abduljabbar TN, Mujawar LH, Danish EY, Soomro MT, El-Shahawi MS. An Eco-Friendly, Interference, and Solvent Free Surfactant-Assisted Dual-Wavelength β-CorrectionSpectrometric Method for Total Determination and Speciation of Cu 2+ Ions in Water. Int J Anal Chem 2023; 2023:5001869. [PMID: 37954135 PMCID: PMC10640129 DOI: 10.1155/2023/5001869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 07/11/2023] [Accepted: 09/20/2023] [Indexed: 11/14/2023] Open
Abstract
Spectral interference through the presence of uninformative variables, excess reagents, and complications in the refinement of the analyte signal is common in the quest to identify complex species in real samples. Therefore, an economical green, facile, and sensitive strategy has been developed for Cu2+ detection using the anionic surfactant sodium dodecylsulphate- (SDS-) assisted dual-wavelength β-correction spectrophotometric strategy combined with the chromogenic reagent zincon (ZI). The low limits of detection (LOD) and quantification (LOQ) of Cu2+ using ordinary (single wavelength) spectrophotometry were 0.19 (3.02) and 0.63 (10.0) μgmL-1, and these values were improved to 0.08 (1.27) and 0.26 μgmL-1 (4.12 μM)) using β-correction (dual wavelength) spectrophotometry, respectively. The LOD and LOQ were improved from 0.08 (1.27) and 0.26 (4.12) μgmL-1 to 0.02 (0.32) and 0.08 μgmL-1 (1.27 μM) using SDS-assisted dual-β-correction spectrometry, respectively. Ringbom, s, and the corrected absorbance (Ac) versus Cu2+ concentration plots were linear over the concentration range 1.10-2.4 (17.4-38.1) and 0.50-2.40 μgmL-1 (7.94-38.1 μM), respectively. Sandell's sensitivity index of 3.0 × 10-3 μg/cm2 was achieved. The selectivity was further confirmed via monitoring the impact of common diverse ions and surfactants on the corrected absorbance. Total determination and Cu2+ speciation in water were favorably implemented and validated by ICP-OES at 95% (P=0.05). Satisfactory Cu2+ recoveries in tap (92.2-98.0%) and mineral (105-111.0%) water samples were achieved. The sensing system is simple, reliable, sensitive, and selective for Cu2+ detection.
Collapse
Affiliation(s)
- Hassan Alwael
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Doaa S. Al-Raimi
- Department of Chemistry, College of Science, University of Jeddah, Jeddah, Saudi Arabia
| | - Khairia M. Al-Ahmary
- Department of Chemistry, College of Science, University of Jeddah, Jeddah, Saudi Arabia
| | - Hany A. Nasef
- Department of Basic Sciences, ta Higher Institute for Engineering and Technology, Mansoura 35111, Egypt
| | - Amal S. Alharthi
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Tharawat N. Abduljabbar
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Liyakat H. Mujawar
- Center of Excellence in Environmental Studies, King Abdulaziz University, P.O. Box 80216, Jeddah 21589, Saudi Arabia
| | - Ekram Y. Danish
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Mohammad T. Soomro
- Center of Excellence in Environmental Studies, King Abdulaziz University, P.O. Box 80216, Jeddah 21589, Saudi Arabia
| | - Mohammad S. El-Shahawi
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| |
Collapse
|
2
|
Multicolor colorimetric assay for copper ion detection based on the etching of gold nanorods. Mikrochim Acta 2022; 189:420. [PMID: 36251083 DOI: 10.1007/s00604-022-05515-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 09/28/2022] [Indexed: 10/24/2022]
Abstract
An effective, selective, and multicolor colorimetric assay for Cu2+ detection based on the regulation of peroxidase-like nanozyme-mediated etching of gold nanorods (Au NRs) is proposed. Cu2+-creatinine complex is selected as the nanozyme that exhibits excellent peroxidase-like activity even in the case of low concentration of Cu2+, which can catalyze 3,3,5,5-tetramethylbenzidine (TMB) to produce oxidized TMB (TMB+) in the presence of hydrogen peroxide, and TMB+ is oxidized to generate TMB2+ after adding H+, and the TMB2+ can etch Au NRs. The determination of Cu2+ is achieved based on the blue shift of the longitudinal localized surface plasmon resonance peak of Au NRs. Under the optimal conditions, the developed colorimetric assay exhibits high sensitivity for the detection of Cu2+ (limit of detection is 0.034 μM) with a wide linear range of 0.05-4.0 μM (R2 = 0.987). The solution shows a rainbow-like color in response to the increase of Cu2+ concentration, which can realize the semi-quantitative detection of Cu2+ by naked eyes. In addition, the developed method exhibits excellent selectivity for Cu2+-detection. The established method was used for the determination of Cu2+ in lake water, soil, and normal human serum with satisfactory recovery of spiked samples.
Collapse
|