1
|
Siagian SN, Tandayu KMH, Reno P, Mendel B, Christianto C, Prakoso R. Echocardiography-guided percutaneous closure of oval-shaped secundum atrial septal defects. BMC Cardiovasc Disord 2024; 24:534. [PMID: 39363250 PMCID: PMC11448078 DOI: 10.1186/s12872-024-04165-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Accepted: 09/04/2024] [Indexed: 10/05/2024] Open
Abstract
BACKGROUND An atrial septal defect (ASD) is considered oval-shaped when its shortest diameter is less than 75% of the longest diameter. Research on percutaneous closure of oval-shaped ASDs is limited, with no known reports of non-fluoroscopic closure for this population. OBJECTIVE To assess the effectiveness of non-fluoroscopic percutaneous closure for oval-shaped ASDs. METHODS This single-center retrospective study evaluates patients undergoing non-fluoroscopic percutaneous closure of oval-shaped ASDs, defined by the shortest to longest diameter ratio < 0.75, a circular index of 1.33, or ultrasound visualization of an oval shape. Device size was chosen to be 0-4 mm larger than the defect's longest diameter, based on transthoracic and transesophageal ultrasound measurements. RESULTS We identified 78 patients (33.3% children, 20.5% males) with a mean age of 27.4 ± 16.3 years and a mean weight of 46.8 ± 19.8 kg. The mean longest diameter and mean shortest diameter of ASDs were 23.3 ± 6.8 mm and 15.8 ± 5 mm, respectively. The mean ratio of the shortest to longest diameter was 0.7 ± 0.1. Percutaneous closure was not attempted in 7/78 (9%) patients. Three out of 71 (4.2%) procedures were fluoroscopy-guided upfront due to technical difficulties, and 5/71 (7%) were converted to fluoroscopy-guided closure. Overall procedural success rate was 98.6% (70/71) including 63/71 (88.7%) performed with zero fluoroscopy. Mean device size was 26.5 ± 7.1 mm. Mean procedural time was 45.3 ± 22.6 min. Eleven intraprocedural complications occurred including 6 arrhythmias, 3 pericardial effusions, and 2 device dislodgements. CONCLUSION Transcatheter closure of oval-shaped ASD is safe and feasible. Echocardiography is adequate for adequate operative guidance.
Collapse
Affiliation(s)
- Sisca Natalia Siagian
- Division of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Center Harapan Kita, Universitas Indonesia, Jakarta, Indonesia.
| | - Kevin Moses Hanky Tandayu
- Department of Cardiology and Vascular Medicine, National Cardiovascular Center Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| | - Putri Reno
- Department of Cardiology and Vascular Medicine, National Cardiovascular Center Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| | - Brian Mendel
- Division of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Center Harapan Kita, Universitas Indonesia, Jakarta, Indonesia.
- Department of Cardiology and Vascular Medicine, Sultan Sulaiman Government Hospital, Serdang Bedagai, North Sumatera, Indonesia.
| | | | - Radityo Prakoso
- Division of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Center Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| |
Collapse
|
2
|
Stujanna EN, Pandhita G, Prakoso R. Resolution of Migraine with Aura Post-PFO Closure in a Young Female: A Case Report. AMERICAN JOURNAL OF CASE REPORTS 2024; 25:e944848. [PMID: 39340790 PMCID: PMC11446259 DOI: 10.12659/ajcr.944848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 08/22/2024] [Accepted: 07/20/2024] [Indexed: 09/30/2024]
Abstract
BACKGROUND Migraine, a prevalent primary headache disorder, often disrupts daily life, particularly when accompanied by visual auras. While the etiology of migraines remains elusive, emerging evidence suggests a correlation with cardiovascular anomalies. CASE REPORT This case involves a 35-year-old woman experiencing migraine with aura. Imaging studies, including MRI/A, revealed small-vessel ischemic damage in the right frontal region and historical microbleeds in the right occipital area. The patient's RoPE score was a high 9 out of 10, and a grade 4 (severe) PFO was diagnosed following a TEE+bubble test. A transfemoral PFO closure was successfully performed using a 25-mm Amplatzer PFO occluder device via an antegrade transvenous approach without fluoroscopy. The patient was discharged in stable condition, with no migraine episodes reported at 5-month follow-up. The detection of PFO in young migraineurs, particularly those with aura, is crucial and warrants thorough investigation during their assessment and treatment. CONCLUSIONS This case underscores the importance of incorporating cardiac evaluations in the diagnostic regimen for young individuals presenting with migraine and aura to uncover and rectify potential contributory structural heart defects like PFO. After PFO closure, this patient's significant improvement, evidenced by the absence of migraine recurrence, highlights the potential therapeutic benefit of addressing cardiac anomalies in such patients. It is important to note that current evidence does not support PFO closure as a treatment for migraines unless there are findings suggestive of ischemic stroke.
Collapse
Affiliation(s)
- Endin Nokik Stujanna
- Faculty of Medicine, Universitas Muhammadiyah Prof. DR. Hamka, Tangerang, Banten, Indonesia
| | - Gea Pandhita
- Laboratory of Neuroscience, Faculty of Medicine, Universitas Muhammadiyah Prof. DR. Hamka, Jakarta, Indonesia
- Pondok Indah Bintaro Jaya Hospital, Tangerang, Banten, Indonesia
| | - Radityo Prakoso
- Divison of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Center of Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| |
Collapse
|
3
|
Mendel B. Gender differences in the diagnostic efficacy of coronary CTA: Overutilization of coronary CTA in pre- and perimenopausal females? An editorial comment. Int J Cardiol 2024; 409:132193. [PMID: 38782073 DOI: 10.1016/j.ijcard.2024.132193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Accepted: 05/20/2024] [Indexed: 05/25/2024]
Affiliation(s)
- Brian Mendel
- Department of Cardiology and Vascular Medicine, Sultan Sulaiman Government Hospital, Serdang Bedagai, North Sumatera, Indonesia.
| |
Collapse
|
4
|
Sihotang FA, Putri V. Dealing With a Nightmare: A Case Report of Successful Percutaneous Treatment of an Embolized Occluder Device Complicating a Minimal-Fluoroscopy Patent Ductus Arteriosus Closure. Cureus 2024; 16:e61926. [PMID: 38978893 PMCID: PMC11228453 DOI: 10.7759/cureus.61926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/07/2024] [Indexed: 07/10/2024] Open
Abstract
Patent ductus arteriosus (PDA) is one of the most prevalent acyanotic congenital heart diseases. Percutaneous closure of PDA has been the preferred treatment recommended by the guidelines due to relatively low complications and rapid patient recovery. However, device emboli remain the most frequent and disastrous complication, necessitating percutaneous or surgical treatment. We present a case of a large PDA closure in pulmonary arterial hypertension paediatric patients complicated with device emboli that was successfully retrieved using the snaring technique. Transcatheter retrieval, although technically challenging, is a feasible treatment and offers the advantage of avoiding the need for surgical intervention.
Collapse
Affiliation(s)
- Fransiska A Sihotang
- Department of Cardiology and Vascular Medicine, Universitas Brawijaya, Saiful Anwar General Hospital, Malang, IDN
| | - Valerinna Putri
- Department of Cardiology and Vascular Medicine, Universitas Brawijaya, Saiful Anwar General Hospital, Malang, IDN
| |
Collapse
|
5
|
Luke K, Milla C, Tandi JK, Julario R. Zero to minimal fluoroscopy for cardiac electronic device implantation: A systematic review and meta-analysis. J Arrhythm 2024; 40:38-46. [PMID: 38333407 PMCID: PMC10848632 DOI: 10.1002/joa3.12949] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 10/11/2023] [Accepted: 10/17/2023] [Indexed: 02/10/2024] Open
Abstract
Background Fluoroscopy is conventionally performed for cardiac implantable electronic device (CIED) therapy and carries radiation drawback for both patients and medical workers. Recently, zero to minimal fluoroscopy (ZMF) approach is introduced to reduce radiation exposure of fluoroscopy. This study compares the feasibility and safety of ZMF approach to fluoroscopy for CIEDs therapy in adults. Method A systematic literature search was conducted on PubMed, ScienceDirect, and Web of Science in March 2023. All observational or experimental studies comparing ZMF approach to fluoroscopy for adult CIEDs therapy were included. Reviews, case report/series, animal studies, and non-English articles were excluded. The success rate, procedural time, fluoroscopy time, radiation dose, and complications rate were compared for each approach. Results Seven articles for permanent and three articles for temporary CIEDs were included for analysis. The success rate of ZMF for permanent CIEDs was similar to fluoroscopy method (OR: 0.77, 95% CI: 0.33-4.15). The procedural time of ZMF was similar to fluoroscopy for both permanent and temporary CIEDs (standardized mean difference [SMD]: 0.10, 95% CI: -0.35 to 0.55 and SMD: -0.71, 95% CI: -1.87-0.44, respectively). However, ZMF approach markedly reduced the fluoroscopy time and radiation exposure for permanent CIEDs (SMD: -1.80, 95% CI: -2.49 to -1.12 and SMD: -1.26, 95% CI: -2.24 to -0.29). The complication rate was similar for permanent CIEDs (OR: 1.08, 95% CI: 0.41-2.84), yet lowered for temporary CIEDs (OR: 0.34, 95% CI: 0.20-0.59). Conclusion ZMF had similar success rate, procedural time, and sum complication rate for permanent CIEDs implantation with a significant reduction of fluoroscopy time and radiation exposure.
Collapse
Affiliation(s)
- Kevin Luke
- Faculty of MedicineUniversitas AirlanggaSurabayaIndonesia
| | - Clonia Milla
- Faculty of MedicineUniversitas AirlanggaSurabayaIndonesia
| | | | - Rerdin Julario
- Department of Cardiology and Vascular MedicineDr. Soetomo General Hospital‐Universitas AirlanggaSurabayaIndonesia
| |
Collapse
|
6
|
Prakoso R, Ariani R, Mendel B, Lilyasari O. Transoesophageal echocardiography-guided balloon-assisted percutaneous closure of a large secundum atrial septal defect in a pregnant woman: a case report. Eur Heart J Case Rep 2024; 8:ytae014. [PMID: 38274706 PMCID: PMC10810588 DOI: 10.1093/ehjcr/ytae014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 12/18/2023] [Accepted: 01/04/2024] [Indexed: 01/27/2024]
Abstract
Background According to the 2018 European Society of Cardiology guidelines, atrial septal defect (ASD) closure can be performed during pregnancy but is rarely indicated. In this case, we demonstrate the viability of percutaneous balloon-assisted ASD closure without fluoroscopy in a pregnant woman. Case summary A 23-year-old G3P2A0 woman who was 20 weeks pregnant had primary complaints of breathlessness [New York Heart Association functional class (NYHA fc) III and IV] for 1 week prior to admission. A transthoracic echocardiography showed a dilatation of the right atrium (RA), a dilated right ventricle, a dilated main pulmonary artery (28.1 mm), and an oval-shaped 22 × 33 mm-sized secundum ASD with a left-to-right shunt. Despite optimal pharmacological treatment, the NYHA fc persisted. Under transoesophageal echocardiography monitoring, we introduced a 40 mm Cera™ ASD Occluder (Lifetech, China) via the delivery sheath. The device was deployed in the usual position; however, despite numerous placement adjustments, the left atrium disc kept getting dislodged to the RA and could not engage correctly. Therefore, we decided to use a balloon-assisted approach using a sizing balloon of No. 34 mm. The device was successfully positioned, and a wiggle test was conducted to make sure that the device remained stable. The patient was able to give birth to the child normally several months later. Discussion Despite the fact that pregnant women with ASD receive a very low dose of radiation, it is nevertheless recommended to avoid radiation because this demographic is particularly vulnerable to it. It is possible to treat a large ASD in pregnant women with a successful balloon-assisted approach.
Collapse
Affiliation(s)
- Radityo Prakoso
- Division of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Letjen S. Parman St No.Kav. 87, Slipi, Palmerah, West Jakarta City, 11420 Jakarta, Indonesia
| | - Rina Ariani
- Division of Non-invasive Diagnostic and Cardiovascular Imaging, Department of Cardiology and Vascular Medicine, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Letjen S. Parman St No.Kav. 87, Slipi, Palmerah, West Jakarta City, 11420 Jakarta, Indonesia
| | - Brian Mendel
- Division of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Letjen S. Parman St No.Kav. 87, Slipi, Palmerah, West Jakarta City, 11420 Jakarta, Indonesia
- Department of Cardiology and Vascular Medicine, Sultan Sulaiman Government Hospital, Serdang Bedagai, Negara 58 No. 315, Firdaus, Sei Rampah, Serdang Bedagai City, 20995 North Sumatera, Indonesia
| | - Oktavia Lilyasari
- Division of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Letjen S. Parman St No.Kav. 87, Slipi, Palmerah, West Jakarta City, 11420 Jakarta, Indonesia
| |
Collapse
|
7
|
Wang G, Wu Y, Pan Z, Wu C, Li Y, Li H, Wang Q, Liu B, Dai J. Transesophageal echocardiography-guided percutaneous patent ductus arteriosus closure without fluoroscopy. J Cardiothorac Surg 2023; 18:142. [PMID: 37060014 PMCID: PMC10105385 DOI: 10.1186/s13019-023-02248-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Accepted: 04/02/2023] [Indexed: 04/16/2023] Open
Abstract
OBJECTIVES A retrospective study was performed to summarize the experience of transcatheter closure of patent ductus arteriosus (PDA) through the right femoral vein under the guidance of transesophageal echocardiography (TEE). METHODS From January 2019 to September 2021, 75 children who underwent PDA closure through the right femoral vein under the guidance of TEE were included. The guide wire and delivery sheath were inserted through the ductus arteriosus into the descending aorta via the right femoral vein, and the occluder was subsequently deployed. After discharge, all patients were required for outpatient follow-ups at 1, 3, 6 and 12 months. RESULTS In this group, patients were older than 10 months of age and body weight greater than 8 kg. Among 75 cases with PDA, 63 were tubular type and 12 were conical type. The mean operative time was 40.2 ± 7.3 min. The size of PDA occluder ranged from 4-6 to 12-14 mm. The mean hospital stay was 5.5 ± 0.5 days. One month after discharge, there were 4 cases with a mild residual shunt. Eventually, the residual shunt was not observed during 3, 6, and 12 months of follow-up. CONCLUSIONS PDA closure under the guidance of TEE can be performed through the right femoral vein successfully and effectively. This procedure has no contrast agent usage, radiation exposure, or open incisions.
Collapse
Affiliation(s)
- Gang Wang
- Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China
- Ministry of Education Key Laboratory of Child Development and Disorders, National Clinical Research Center for Child Health and Disorders, Chongqing Key Laboratory of Pediatrics, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing, China
| | - Yuhao Wu
- Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China
- Ministry of Education Key Laboratory of Child Development and Disorders, National Clinical Research Center for Child Health and Disorders, Chongqing Key Laboratory of Pediatrics, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing, China
| | - Zhengxia Pan
- Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China
- Ministry of Education Key Laboratory of Child Development and Disorders, National Clinical Research Center for Child Health and Disorders, Chongqing Key Laboratory of Pediatrics, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing, China
| | - Chun Wu
- Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China
- Ministry of Education Key Laboratory of Child Development and Disorders, National Clinical Research Center for Child Health and Disorders, Chongqing Key Laboratory of Pediatrics, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing, China
| | - Yonggang Li
- Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China
- Ministry of Education Key Laboratory of Child Development and Disorders, National Clinical Research Center for Child Health and Disorders, Chongqing Key Laboratory of Pediatrics, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing, China
| | - Hongbo Li
- Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China
- Ministry of Education Key Laboratory of Child Development and Disorders, National Clinical Research Center for Child Health and Disorders, Chongqing Key Laboratory of Pediatrics, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing, China
| | - Quan Wang
- Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China
- Ministry of Education Key Laboratory of Child Development and Disorders, National Clinical Research Center for Child Health and Disorders, Chongqing Key Laboratory of Pediatrics, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing, China
| | - Bo Liu
- Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China
- Ministry of Education Key Laboratory of Child Development and Disorders, National Clinical Research Center for Child Health and Disorders, Chongqing Key Laboratory of Pediatrics, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing, China
| | - Jiangtao Dai
- Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China.
- Ministry of Education Key Laboratory of Child Development and Disorders, National Clinical Research Center for Child Health and Disorders, Chongqing Key Laboratory of Pediatrics, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing, China.
| |
Collapse
|
8
|
Siagian SN, Prakoso R, Mendel B, Hazami Z, Putri VYS, Zulfahmi, Sakti DDA, Kuncoro AS. Transesophageal echocardiography-guided percutaneous closure of multiple muscular ventricular septal defects with pulmonary hypertension using single device: A case report. Front Cardiovasc Med 2023; 10:1093563. [PMID: 37034333 PMCID: PMC10076841 DOI: 10.3389/fcvm.2023.1093563] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Accepted: 03/03/2023] [Indexed: 05/03/2024] Open
Abstract
BACKGROUND Surgery is typically used to correct challenging ventricular septal defects (VSDs), such as VSD with pulmonary hypertension and multiple defects. In this case report, we would like to highlight the feasibility of multiple defects VSD closure with single device percutaneously using zero-fluoroscopy technique. CASE PRESENTATION A 7-year-old child was referred with the main symptom of shortness of breath. She started experiencing repeated respiratory tract infections, feeding issues, and failure to thrive at the age of six months. Her body weight was only 18 kg. TEE revealed several muscular VSD with 2-3 mm and 12 mm diameters, 3 mm spacing between VSD, L to R shunt, AR (-), and TR mild with septal leaflet tricuspid prolapse. Following right heart catheterization (Qp:Qs 3.5, PVRi 5.23WUmsq, PVR 4.55 WU, PVR/SVR 0.16), we made the decision to correct the defect using an Amplatzer Septal Occluder (AGA) No. 16 mm using transjugular method. Full device deployment was successfully performed with several episodes of PVC storm and severe bradycardia. One and a half years after the procedure, her TVG dropped to only 18 mmHg, her visible indicators of PH subsided, and the PA dilator treatment was discontinued. Her body weight had increased to 28 kg, and she had no complaints. CONCLUSIONS Our experience demonstrated that percutaneous closure of multiple VSD with a single device is possible, even with pulmonary hypertension.
Collapse
Affiliation(s)
- Sisca Natalia Siagian
- Department of Cardiology andVascular Medicine, Division of Pediatric Cardiology and Congenital Heart Disease, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| | - Radityo Prakoso
- Department of Cardiology andVascular Medicine, Division of Pediatric Cardiology and Congenital Heart Disease, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| | - Brian Mendel
- Department of Cardiology andVascular Medicine, Division of Pediatric Cardiology and Congenital Heart Disease, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
- Department of Cardiology and Vascular Medicine, Sultan Sulaiman Government Hospital, Serdang Bedagai, Indonesia
| | - Zakky Hazami
- Department of Cardiology and Vascular Medicine, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| | - Valerinna Yogibuana Swastika Putri
- Department of Cardiology andVascular Medicine, Division of Pediatric Cardiology and Congenital Heart Disease, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| | - Zulfahmi
- Department of Cardiology andVascular Medicine, Division of Pediatric Cardiology and Congenital Heart Disease, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| | - Damba Dwisepto Aulia Sakti
- Department of Cardiology andVascular Medicine, Division of Pediatric Cardiology and Congenital Heart Disease, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| | - Ario Soeryo Kuncoro
- Department of Cardiology and Vascular Medicine, Division of Non-Invasive Diagnostic and Cardiovacular Imaging, National Cardiovascular Centre Harapan Kita, Universitas Indonesia, Jakarta, Indonesia
| |
Collapse
|