1
|
Kaveh R, Schwendeman C, Pu L, Arias AC, Muller R. Wireless ear EEG to monitor drowsiness. Nat Commun 2024; 15:6520. [PMID: 39095399 PMCID: PMC11297174 DOI: 10.1038/s41467-024-48682-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Accepted: 05/09/2024] [Indexed: 08/04/2024] Open
Abstract
Neural wearables can enable life-saving drowsiness and health monitoring for pilots and drivers. While existing in-cabin sensors may provide alerts, wearables can enable monitoring across more environments. Current neural wearables are promising but most require wet-electrodes and bulky electronics. This work showcases in-ear, dry-electrode earpieces used to monitor drowsiness with compact hardware. The employed system integrates additive-manufacturing for dry, user-generic earpieces, existing wireless electronics, and offline classification algorithms. Thirty-five hours of electrophysiological data were recorded across nine subjects performing drowsiness-inducing tasks. Three classifier models were trained with user-specific, leave-one-trial-out, and leave-one-user-out splits. The support-vector-machine classifier achieved an accuracy of 93.2% while evaluating users it has seen before and 93.3% when evaluating a never-before-seen user. These results demonstrate wireless, dry, user-generic earpieces used to classify drowsiness with comparable accuracies to existing state-of-the-art, wet electrode in-ear and scalp systems. Further, this work illustrates the feasibility of population-trained classification in future electrophysiological applications.
Collapse
Affiliation(s)
- Ryan Kaveh
- University of California Berkeley, Berkeley, CA, 94708, USA.
| | | | - Leslie Pu
- University of California Berkeley, Berkeley, CA, 94708, USA
| | - Ana C Arias
- University of California Berkeley, Berkeley, CA, 94708, USA
| | - Rikky Muller
- University of California Berkeley, Berkeley, CA, 94708, USA.
| |
Collapse
|
2
|
Sugden RJ, Campbell I, Pham-Kim-Nghiem-Phu VLL, Higazy R, Dent E, Edelstein K, Leon A, Diamandis P. HEROIC: a platform for remote collection of electroencephalographic data using consumer-grade brain wearables. BMC Bioinformatics 2024; 25:243. [PMID: 39026153 PMCID: PMC11256487 DOI: 10.1186/s12859-024-05865-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Accepted: 07/10/2024] [Indexed: 07/20/2024] Open
Abstract
The growing number of portable consumer-grade electroencephalography (EEG) wearables offers potential to track brain activity and neurological disease in real-world environments. However, accompanying open software tools to standardize custom recordings and help guide independent operation by users is lacking. To address this gap, we developed HEROIC, an open-source software that allows participants to remotely collect advanced EEG data without the aid of an expert technician. The aim of HEROIC is to provide an open software platform that can be coupled with consumer grade wearables to record EEG data during customized neurocognitive tasks outside of traditional research environments. This article contains a description of HEROIC's implementation, how it can be used by researchers and a proof-of-concept demonstration highlighting the potential for HEROIC to be used as a scalable and low-cost EEG data collection tool. Specifically, we used HEROIC to guide healthy participants through standardized neurocognitive tasks and captured complex brain data including event-related potentials (ERPs) and powerband changes in participants' homes. Our results demonstrate HEROIC's capability to generate data precisely synchronized to presented stimuli, using a low-cost, remote protocol without reliance on an expert operator to administer sessions. Together, our software and its capabilities provide the first democratized and scalable platform for large-scale remote and longitudinal analysis of brain health and disease.
Collapse
Affiliation(s)
- Richard James Sugden
- Department of Medical Biophysics, University of Toronto, Toronto, ON, M5S 1A8, Canada
- Princess Margaret Cancer Center, University Health Network, 610 University Avenue, Toronto, ON, M5G 2C1, Canada
| | - Ingrid Campbell
- Princess Margaret Cancer Center, University Health Network, 610 University Avenue, Toronto, ON, M5G 2C1, Canada
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, M5S 1A8, Canada
| | | | - Randa Higazy
- Princess Margaret Cancer Center, University Health Network, 610 University Avenue, Toronto, ON, M5G 2C1, Canada
| | - Eliza Dent
- Cognitive Science Program, McGill University, 845 Rue Sherbrooke O, Montréal, QC, H3A 0G4, Canada
| | - Kim Edelstein
- Department of Supportive Care, Princess Margaret Cancer Centre, Toronto, ON, M5G 2C4, Canada
- Department of Psychiatry, University of Toronto, Toronto, ON, M5S 1A8, Canada
| | - Alberto Leon
- Princess Margaret Cancer Center, University Health Network, 610 University Avenue, Toronto, ON, M5G 2C1, Canada
| | - Phedias Diamandis
- Department of Medical Biophysics, University of Toronto, Toronto, ON, M5S 1A8, Canada.
- Laboratory Medicine Program, University Health Network, 200 Elizabeth Street, Toronto, ON, M5G 2C4, Canada.
- Department of Pathology, University Health Network 12-308, Toronto Medical Discovery Tower (TMDT), 101 College St, Toronto, M5G 1L7, Canada.
| |
Collapse
|
3
|
Eidel M, Pfeiffer M, Ziebell P, Kübler A. Recording the tactile P300 with the cEEGrid for potential use in a brain-computer interface. Front Hum Neurosci 2024; 18:1371631. [PMID: 38957693 PMCID: PMC11218745 DOI: 10.3389/fnhum.2024.1371631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 05/27/2024] [Indexed: 07/04/2024] Open
Abstract
Brain-computer interfaces (BCIs) are scientifically well established, but they rarely arrive in the daily lives of potential end-users. This could be in part because electroencephalography (EEG), a prevalent method to acquire brain activity for BCI operation, is considered too impractical to be applied in daily life of end-users with physical impairment as an assistive device. Hence, miniaturized EEG systems such as the cEEGrid have been developed. While they promise to be a step toward bridging the gap between BCI development, lab demonstrations, and home use, they still require further validation. Encouragingly, the cEEGrid has already demonstrated its ability to record visually and auditorily evoked event-related potentials (ERP), which are important as input signal for many BCIs. With this study, we aimed at evaluating the cEEGrid in the context of a BCI based on tactually evoked ERPs. To compare the cEEGrid with a conventional scalp EEG, we recorded brain activity with both systems simultaneously. Forty healthy participants were recruited to perform a P300 oddball task based on vibrotactile stimulation at four different positions. This tactile paradigm has been shown to be feasible for BCI repeatedly but has never been tested with the cEEGrid. We found distinct P300 deflections in the cEEGrid data, particularly at vertical bipolar channels. With an average of 63%, the cEEGrid classification accuracy was significantly above the chance level (25%) but significantly lower than the 81% reached with the EEG cap. Likewise, the P300 amplitude was significantly lower (cEEGrid R2-R7: 1.87 μV, Cap Cz: 3.53 μV). These results indicate that a tactile BCI using the cEEGrid could potentially be operated, albeit with lower efficiency. Additionally, participants' somatosensory sensitivity was assessed, but no correlation to the accuracy of either EEG system was shown. Our research contributes to the growing amount of literature comparing the cEEGrid to conventional EEG systems and provides first evidence that the tactile P300 can be recorded behind the ear. A BCI based on a thus simplified EEG system might be more readily accepted by potential end-users, provided the accuracy can be substantially increased, e.g., by training and improved classification.
Collapse
Affiliation(s)
- M. Eidel
- Institute of Psychology, University of Würzburg, Würzburg, Germany
| | | | | | | |
Collapse
|
4
|
Radke FA, da Silva Souto CF, Pätzold W, Wolf KI. Transfer Learning for Automatic Sleep Staging Using a Pre-Gelled Electrode Grid. Diagnostics (Basel) 2024; 14:909. [PMID: 38732323 PMCID: PMC11083934 DOI: 10.3390/diagnostics14090909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 04/18/2024] [Accepted: 04/24/2024] [Indexed: 05/13/2024] Open
Abstract
Novel sensor solutions for sleep monitoring at home could alleviate bottlenecks in sleep medical care as well as enable selective or continuous observation over long periods of time and contribute to new insights in sleep medicine and beyond. Since especially in the latter case the sensor data differ strongly in signal, number and extent of sensors from the classical polysomnography (PSG) sensor technology, an automatic evaluation is essential for the application. However, the training of an automatic algorithm is complicated by the fact that the development phase of the new sensor technology, extensive comparative measurements with standardized reference systems, is often not possible and therefore only small datasets are available. In order to circumvent high system-specific training data requirements, we employ pre-training on large datasets with finetuning on small datasets of new sensor technology to enable automatic sleep phase detection for small test series. By pre-training on publicly available PSG datasets and finetuning on 12 nights recorded with new sensor technology based on a pre-gelled electrode grid to capture electroencephalography (EEG), electrooculography (EOG) and electromyography (EMG), an F1 score across all sleep phases of 0.81 is achieved (wake 0.84, N1 0.62, N2 0.81, N3 0.87, REM 0.88), using only EEG and EOG. The analysis additionally considers the spatial distribution of the channels and an approach to approximate classical electrode positions based on specific linear combinations of the new sensor grid channels.
Collapse
Affiliation(s)
- Fabian A. Radke
- Fraunhofer Institute for Digital Media Technology IDMT, Oldenburg Branch for Hearing, Speech and Audio Technology HSA, 26129 Oldenburg, Germany
| | | | | | | |
Collapse
|
5
|
Baumert M, Phan H. A perspective on automated rapid eye movement sleep assessment. J Sleep Res 2024:e14223. [PMID: 38650539 DOI: 10.1111/jsr.14223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 02/18/2024] [Accepted: 04/08/2024] [Indexed: 04/25/2024]
Abstract
Rapid eye movement sleep is associated with distinct changes in various biomedical signals that can be easily captured during sleep, lending themselves to automated sleep staging using machine learning systems. Here, we provide a perspective on the critical characteristics of biomedical signals associated with rapid eye movement sleep and how they can be exploited for automated sleep assessment. We summarise key historical developments in automated sleep staging systems, having now achieved classification accuracy on par with human expert scorers and their role in the clinical setting. We also discuss rapid eye movement sleep assessment with consumer sleep trackers and its potential for unprecedented sleep assessment on a global scale. We conclude by providing a future outlook of computerised rapid eye movement sleep assessment and the role AI systems may play.
Collapse
Affiliation(s)
- Mathias Baumert
- Discipline of Biomedical Engineering, School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, Australia
| | - Huy Phan
- Amazon, Cambridge, Massachusetts, USA
| |
Collapse
|
6
|
Rusanen M, Korkalainen H, Gretarsdottir H, Siilak T, Olafsdottir KA, Töyräs J, Myllymaa S, Arnardottir ES, Leppänen T, Kainulainen S. Self-applied somnography: technical feasibility of electroencephalography and electro-oculography signal characteristics in sleep staging of suspected sleep-disordered adults. J Sleep Res 2024; 33:e13977. [PMID: 37400248 DOI: 10.1111/jsr.13977] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 06/05/2023] [Accepted: 06/12/2023] [Indexed: 07/05/2023]
Abstract
Sleep recordings are increasingly being conducted in patients' homes where patients apply the sensors themselves according to instructions. However, certain sensor types such as cup electrodes used in conventional polysomnography are unfeasible for self-application. To overcome this, self-applied forehead montages with electroencephalography and electro-oculography sensors have been developed. We evaluated the technical feasibility of a self-applied electrode set from Nox Medical (Reykjavik, Iceland) through home sleep recordings of healthy and suspected sleep-disordered adults (n = 174) in the context of sleep staging. Subjects slept with a double setup of conventional type II polysomnography sensors and self-applied forehead sensors. We found that the self-applied electroencephalography and electro-oculography electrodes had acceptable impedance levels but were more prone to losing proper skin-electrode contact than the conventional cup electrodes. Moreover, the forehead electroencephalography signals recorded using the self-applied electrodes expressed lower amplitudes (difference 25.3%-43.9%, p < 0.001) and less absolute power (at 1-40 Hz, p < 0.001) than the polysomnography electroencephalography signals in all sleep stages. However, the signals recorded with the self-applied electroencephalography electrodes expressed more relative power (p < 0.001) at very low frequencies (0.3-1.0 Hz) in all sleep stages. The electro-oculography signals recorded with the self-applied electrodes expressed comparable characteristics with standard electro-oculography. In conclusion, the results support the technical feasibility of the self-applied electroencephalography and electro-oculography for sleep staging in home sleep recordings, after adjustment for amplitude differences, especially for scoring Stage N3 sleep.
Collapse
Affiliation(s)
- Matias Rusanen
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| | - Henri Korkalainen
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| | - Heidur Gretarsdottir
- Reykjavik University Sleep Institute, School of Technology, Reykjavik University, Reykjavik, Iceland
- Landspitali-The National University Hospital of Iceland, Reykjavik, Iceland
| | - Tiina Siilak
- Reykjavik University Sleep Institute, School of Technology, Reykjavik University, Reykjavik, Iceland
| | - Kristin Anna Olafsdottir
- Reykjavik University Sleep Institute, School of Technology, Reykjavik University, Reykjavik, Iceland
| | - Juha Töyräs
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
- Science Service Center, Kuopio University Hospital, Kuopio, Finland
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Queensland, Australia
| | - Sami Myllymaa
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| | - Erna Sif Arnardottir
- Reykjavik University Sleep Institute, School of Technology, Reykjavik University, Reykjavik, Iceland
- Landspitali-The National University Hospital of Iceland, Reykjavik, Iceland
| | - Timo Leppänen
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Queensland, Australia
| | - Samu Kainulainen
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| |
Collapse
|
7
|
Meiser A, Lena Knoll A, Bleichner MG. High-density ear-EEG for understanding ear-centered EEG. J Neural Eng 2024; 21:016001. [PMID: 38118173 DOI: 10.1088/1741-2552/ad1783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 12/20/2023] [Indexed: 12/22/2023]
Abstract
Background. Mobile ear-EEG provides the opportunity to record EEG unobtrusively in everyday life. However, in real-life, the EEG data quickly becomes difficult to interpret, as the neural signal is contaminated by other, non-neural signal contributions. Due to the small number of electrodes in ear-EEG devices, the interpretation of the EEG becomes even more difficult. For meaningful and reliable ear-EEG, it is crucial that the brain signals we wish to record in real life are well-understood and that we make optimal use of the available electrodes. Their placement should be guided by prior knowledge about the characteristics of the signal of interest.Objective.We want to understand the signal we record with ear-EEG and make recommendations on how to optimally place a limited number of electrodes.Approach.We built a high-density ear-EEG with 31 channels spaced densely around one ear. We used it to record four auditory event-related potentials (ERPs): the mismatch negativity, the P300, the N100 and the N400. With this data, we gain an understanding of how different stages of auditory processing are reflected in ear-EEG. We investigate the electrode configurations that carry the most information and use a mass univariate ERP analysis to identify the optimal channel configuration. We additionally use a multivariate approach to investigate the added value of multi-channel recordings.Main results.We find significant condition differences for all ERPs. The different ERPs vary considerably in their spatial extent and different electrode positions are necessary to optimally capture each component. In the multivariate analysis, we find that the investigation of the ERPs benefits strongly from multi-channel ear-EEG.Significance.Our work emphasizes the importance of a strong theoretical and practical background when building and using ear-EEG. We provide recommendations on finding the optimal electrode positions. These results will guide future research employing ear-EEG in real-life scenarios.
Collapse
Affiliation(s)
- Arnd Meiser
- Neurophysiology of Everyday Life Group, Department of Psychology, University of Oldenburg, Oldenburg, Germany
- Faculty of Business Studies and Economics, University of Bremen, Bremen, Germany
| | - Anna Lena Knoll
- Neurophysiology of Everyday Life Group, Department of Psychology, University of Oldenburg, Oldenburg, Germany
| | - Martin G Bleichner
- Neurophysiology of Everyday Life Group, Department of Psychology, University of Oldenburg, Oldenburg, Germany
- Research Center for Neurosensory Science, University of Oldenburg, Oldenburg, Germany
| |
Collapse
|
8
|
Mohamed M, Mohamed N, Kim JG. Advancements in Wearable EEG Technology for Improved Home-Based Sleep Monitoring and Assessment: A Review. BIOSENSORS 2023; 13:1019. [PMID: 38131779 PMCID: PMC10741861 DOI: 10.3390/bios13121019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 12/03/2023] [Accepted: 12/05/2023] [Indexed: 12/23/2023]
Abstract
Sleep is a fundamental aspect of daily life, profoundly impacting mental and emotional well-being. Optimal sleep quality is vital for overall health and quality of life, yet many individuals struggle with sleep-related difficulties. In the past, polysomnography (PSG) has served as the gold standard for assessing sleep, but its bulky nature, cost, and the need for expertise has made it cumbersome for widespread use. By recognizing the need for a more accessible and user-friendly approach, wearable home monitoring systems have emerged. EEG technology plays a pivotal role in sleep monitoring, as it captures crucial brain activity data during sleep and serves as a primary indicator of sleep stages and disorders. This review provides an overview of the most recent advancements in wearable sleep monitoring leveraging EEG technology. We summarize the latest EEG devices and systems available in the scientific literature, highlighting their design, form factors, materials, and methods of sleep assessment. By exploring these developments, we aim to offer insights into cutting-edge technologies, shedding light on wearable EEG sensors for advanced at-home sleep monitoring and assessment. This comprehensive review contributes to a broader perspective on enhancing sleep quality and overall health using wearable EEG sensors.
Collapse
Affiliation(s)
| | | | - Jae Gwan Kim
- Biomedical Science and Engineering Department, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea; (M.M.); (N.M.)
| |
Collapse
|
9
|
Kaongoen N, Choi J, Woo Choi J, Kwon H, Hwang C, Hwang G, Kim BH, Jo S. The future of wearable EEG: a review of ear-EEG technology and its applications. J Neural Eng 2023; 20:051002. [PMID: 37748474 DOI: 10.1088/1741-2552/acfcda] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 09/25/2023] [Indexed: 09/27/2023]
Abstract
Objective.This review paper provides a comprehensive overview of ear-electroencephalogram (EEG) technology, which involves recording EEG signals from electrodes placed in or around the ear, and its applications in the field of neural engineering.Approach.We conducted a thorough literature search using multiple databases to identify relevant studies related to ear-EEG technology and its various applications. We selected 123 publications and synthesized the information to highlight the main findings and trends in this field.Main results.Our review highlights the potential of ear-EEG technology as the future of wearable EEG technology. We discuss the advantages and limitations of ear-EEG compared to traditional scalp-based EEG and methods to overcome those limitations. Through our review, we found that ear-EEG is a promising method that produces comparable results to conventional scalp-based methods. We review the development of ear-EEG sensing devices, including the design, types of sensors, and materials. We also review the current state of research on ear-EEG in different application areas such as brain-computer interfaces, and clinical monitoring.Significance.This review paper is the first to focus solely on reviewing ear-EEG research articles. As such, it serves as a valuable resource for researchers, clinicians, and engineers working in the field of neural engineering. Our review sheds light on the exciting future prospects of ear-EEG, and its potential to advance neural engineering research and become the future of wearable EEG technology.
Collapse
Affiliation(s)
- Netiwit Kaongoen
- Information and Electronics Research Institute, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Jaehoon Choi
- School of Computing, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Jin Woo Choi
- Department of Neurology and Neurological Sciences, Stanford University School of Medicine, Stanford, CA 94304, United States of America
| | - Haram Kwon
- School of Computing, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Chaeeun Hwang
- School of Computing, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Guebin Hwang
- Robotics Program, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Byung Hyung Kim
- Department of Artificial Intelligence, Inha University, Incheon, Republic of Korea
| | - Sungho Jo
- School of Computing, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| |
Collapse
|
10
|
Yin J, Xu J, Ren TL. Recent Progress in Long-Term Sleep Monitoring Technology. BIOSENSORS 2023; 13:395. [PMID: 36979607 PMCID: PMC10046225 DOI: 10.3390/bios13030395] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 03/11/2023] [Accepted: 03/14/2023] [Indexed: 06/18/2023]
Abstract
Sleep is an essential physiological activity, accounting for about one-third of our lives, which significantly impacts our memory, mood, health, and children's growth. Especially after the COVID-19 epidemic, sleep health issues have attracted more attention. In recent years, with the development of wearable electronic devices, there have been more and more studies, products, or solutions related to sleep monitoring. Many mature technologies, such as polysomnography, have been applied to clinical practice. However, it is urgent to develop wearable or non-contacting electronic devices suitable for household continuous sleep monitoring. This paper first introduces the basic knowledge of sleep and the significance of sleep monitoring. Then, according to the types of physiological signals monitored, this paper describes the research progress of bioelectrical signals, biomechanical signals, and biochemical signals used for sleep monitoring. However, it is not ideal to monitor the sleep quality for the whole night based on only one signal. Therefore, this paper reviews the research on multi-signal monitoring and introduces systematic sleep monitoring schemes. Finally, a conclusion and discussion of sleep monitoring are presented to propose potential future directions and prospects for sleep monitoring.
Collapse
Affiliation(s)
- Jiaju Yin
- School of Integrated Circuits, Tsinghua University, Beijing 100084, China
- Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China
| | - Jiandong Xu
- School of Integrated Circuits, Tsinghua University, Beijing 100084, China
- Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China
| | - Tian-Ling Ren
- School of Integrated Circuits, Tsinghua University, Beijing 100084, China
- Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China
- Center for Flexible Electronics Technology, Tsinghua University, Beijing 100084, China
| |
Collapse
|
11
|
da Silva Souto CF, Pätzold W, Paul M, Debener S, Wolf KI. Pre-gelled Electrode Grid for Self-Applied EEG Sleep Monitoring at Home. Front Neurosci 2022; 16:883966. [PMID: 35812225 PMCID: PMC9263847 DOI: 10.3389/fnins.2022.883966] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 06/06/2022] [Indexed: 11/13/2022] Open
Abstract
The need for diagnostic capabilities for sleep disorders such as sleep apnea and insomnia far exceeds the capacity of inpatient sleep laboratories. Some home monitoring systems omit electroencephalography (EEG) because trained personnel may be needed to apply EEG sensors. Since EEG is essential for the detailed evaluation of sleep, better systems supporting the convenient and robust recording of sleep EEG at home are desirable. Recent advances in EEG acquisition with flex-printed sensors promise easier application of EEG sensor arrays for chronic recordings, yet these sensor arrays were not designed for sleep EEG. Here we explored the self-applicability of a new sleep EEG sensor array (trEEGrid) without prior training. We developed a prototype with pre-gelled neonatal ECG electrodes placed on a self-adhesive grid shape that guided the fast and correct positioning of a total of nine electrodes on the face and around the ear. Positioning of the sensors was based on the results of a previous ear-EEG sleep study (da Silva Souto et al., 2021), and included electrodes around the ear, one eye, and the chin. For comparison, EEG and electrooculogram channels placed according to the American Academy of Sleep Medicine criteria, as well as respiratory inductance plethysmography on thorax and abdomen, oxygen saturation, pulse and body position were included with a mobile polysomnography (PSG) system. Two studies with 32 individuals were conducted to compare the signal quality of the proposed flex-printed grid with PSG signals and to explore self-application of the new grid at home. Results indicate that the new array is self-applicable by healthy participants without on-site hands-on support. A comparison of the hypnogram annotations obtained from the data of both systems revealed an overall substantial agreement on a group level (Cohen’s κ = 0.70 ± 0.01). These results suggest that flex-printed pre-gelled sensor arrays designed for sleep EEG acquisition can facilitate self-recording at home.
Collapse
Affiliation(s)
- Carlos F. da Silva Souto
- Fraunhofer Institute for Digital Media Technology IDMT, Branch Hearing, Speech and Audio Technology HSA, Oldenburg, Germany
- *Correspondence: Carlos F. da Silva Souto,
| | - Wiebke Pätzold
- Fraunhofer Institute for Digital Media Technology IDMT, Branch Hearing, Speech and Audio Technology HSA, Oldenburg, Germany
| | | | - Stefan Debener
- Fraunhofer Institute for Digital Media Technology IDMT, Branch Hearing, Speech and Audio Technology HSA, Oldenburg, Germany
- Neuropsychology Laboratory, Department of Psychology, University of Oldenburg, Oldenburg, Germany
- Cluster of Excellence Hearing4All, University of Oldenburg, Oldenburg, Germany
| | - Karen Insa Wolf
- Fraunhofer Institute for Digital Media Technology IDMT, Branch Hearing, Speech and Audio Technology HSA, Oldenburg, Germany
| |
Collapse
|
12
|
Holtze B, Rosenkranz M, Jaeger M, Debener S, Mirkovic B. Ear-EEG Measures of Auditory Attention to Continuous Speech. Front Neurosci 2022; 16:869426. [PMID: 35592265 PMCID: PMC9111016 DOI: 10.3389/fnins.2022.869426] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 03/25/2022] [Indexed: 11/13/2022] Open
Abstract
Auditory attention is an important cognitive function used to separate relevant from irrelevant auditory information. However, most findings on attentional selection have been obtained in highly controlled laboratory settings using bulky recording setups and unnaturalistic stimuli. Recent advances in electroencephalography (EEG) facilitate the measurement of brain activity outside the laboratory, and around-the-ear sensors such as the cEEGrid promise unobtrusive acquisition. In parallel, methods such as speech envelope tracking, intersubject correlations and spectral entropy measures emerged which allow us to study attentional effects in the neural processing of natural, continuous auditory scenes. In the current study, we investigated whether these three attentional measures can be reliably obtained when using around-the-ear EEG. To this end, we analyzed the cEEGrid data of 36 participants who attended to one of two simultaneously presented speech streams. Speech envelope tracking results confirmed a reliable identification of the attended speaker from cEEGrid data. The accuracies in identifying the attended speaker increased when fitting the classification model to the individual. Artifact correction of the cEEGrid data with artifact subspace reconstruction did not increase the classification accuracy. Intersubject correlations were higher for those participants attending to the same speech stream than for those attending to different speech streams, replicating previously obtained results with high-density cap-EEG. We also found that spectral entropy decreased over time, possibly reflecting the decrease in the listener's level of attention. Overall, these results support the idea of using ear-EEG measurements to unobtrusively monitor auditory attention to continuous speech. This knowledge may help to develop assistive devices that support listeners separating relevant from irrelevant information in complex auditory environments.
Collapse
Affiliation(s)
- Björn Holtze
- Neuropsychology Lab, Department of Psychology, University of Oldenburg, Oldenburg, Germany
| | - Marc Rosenkranz
- Neurophysiology of Everyday Life Group, Department of Psychology, University of Oldenburg, Oldenburg, Germany
| | - Manuela Jaeger
- Neuropsychology Lab, Department of Psychology, University of Oldenburg, Oldenburg, Germany
- Division Hearing, Speech and Audio Technology, Fraunhofer Institute for Digital Media Technology IDMT, Oldenburg, Germany
| | - Stefan Debener
- Neuropsychology Lab, Department of Psychology, University of Oldenburg, Oldenburg, Germany
- Research Center for Neurosensory Science, University of Oldenburg, Oldenburg, Germany
- Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany
| | - Bojana Mirkovic
- Neuropsychology Lab, Department of Psychology, University of Oldenburg, Oldenburg, Germany
| |
Collapse
|