1
|
Alstrup AKO, Busk M, Dittrich A, Hansen K, Wang T, Damkjær M, Andersen JB, Lauridsen H. Special Challenges in PET Imaging of Ectothermic Vertebrates. Semin Nucl Med 2023; 53:577-585. [PMID: 37438172 DOI: 10.1053/j.semnuclmed.2023.06.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Accepted: 06/18/2023] [Indexed: 07/14/2023]
Abstract
The bulk of biomedical positron emission tomography (PET)-scanning experiments are performed on mammals (ie, rodents, pigs, and dogs), and the technique is only infrequently applied to answer research questions in ectothermic vertebrates such as fish, amphibians, and reptiles. Nevertheless, many unique and interesting physiological characteristics in these ectothermic vertebrates could be addressed in detail through PET. The low metabolic rate of ectothermic animals, however, may compromise the validity of physiological and biochemical parameters derived from the images created by PET and other scanning modalities. Here, we review some of the considerations that should be taken into account when PET scanning fish, amphibians, and reptiles. We present specific results from our own experiments, many of which remain previously unpublished, and we draw on examples from the literature. We conclude that knowledge on the natural history and physiology of the species studied and an understanding of the limitations of the PET scanning techniques are necessary to avoid the design of faulty experiments and erroneous conclusions.
Collapse
Affiliation(s)
- Aage Kristian Olsen Alstrup
- Department of Nuclear Medicine and PET, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
| | - Morten Busk
- Experimental Clinical Oncology, Aarhus University, Denmark; Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - Anita Dittrich
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Kasper Hansen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; Department of Forensic Medicine, Aarhus University, Aarhus, Denmark; Zoophysiology, Department of Biology, Aarhus University, Aarhus, Denmark
| | - Tobias Wang
- Zoophysiology, Department of Biology, Aarhus University, Aarhus, Denmark
| | - Mads Damkjær
- Department of Paediatrics and Adolescent Medicine, Lillebaelt Hospital, University Hospital of Southern Denmark, Kolding, Denmark; Department of Regional Health Research, University of Southern Denmark, Odense, Denmark
| | | | - Henrik Lauridsen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
2
|
Petroni D, Fabbri C, Babboni S, Menichetti L, Basta G, Del Turco S. Extracellular Vesicles and Intercellular Communication: Challenges for In Vivo Molecular Imaging and Tracking. Pharmaceutics 2023; 15:1639. [PMID: 37376087 PMCID: PMC10301899 DOI: 10.3390/pharmaceutics15061639] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/23/2023] [Accepted: 05/30/2023] [Indexed: 06/29/2023] Open
Abstract
Extracellular vesicles (EVs) are a heterogeneous class of cell-derived membrane vesicles released by various cell types that serve as mediators of intercellular signaling. When released into circulation, EVs may convey their cargo and serve as intermediaries for intracellular communication, reaching nearby cells and possibly also distant organs. In cardiovascular biology, EVs released by activated or apoptotic endothelial cells (EC-EVs) disseminate biological information at short and long distances, contributing to the development and progression of cardiovascular disease and related disorders. The significance of EC-EVs as mediators of cell-cell communication has advanced, but a thorough knowledge of the role that intercommunication plays in healthy and vascular disease is still lacking. Most data on EVs derive from in vitro studies, but there are still little reliable data available on biodistribution and specific homing EVs in vivo tissues. Molecular imaging techniques for EVs are crucial to monitoring in vivo biodistribution and the homing of EVs and their communication networks both in basal and pathological circumstances. This narrative review provides an overview of EC-EVs, trying to highlight their role as messengers of cell-cell interaction in vascular homeostasis and disease, and describes emerging applications of various imaging modalities for EVs visualization in vivo.
Collapse
Affiliation(s)
- Debora Petroni
- Institute of Clinical Physiology, CNR San Cataldo Research Area, Via Moruzzi 1, 56124 Pisa, Italy
| | - Costanza Fabbri
- Institute of Clinical Physiology, CNR San Cataldo Research Area, Via Moruzzi 1, 56124 Pisa, Italy
- Institute of Life Sciences, Scuola Superiore Sant’Anna, 56127 Pisa, Italy
| | - Serena Babboni
- Institute of Clinical Physiology, CNR San Cataldo Research Area, Via Moruzzi 1, 56124 Pisa, Italy
| | - Luca Menichetti
- Institute of Clinical Physiology, CNR San Cataldo Research Area, Via Moruzzi 1, 56124 Pisa, Italy
| | - Giuseppina Basta
- Institute of Clinical Physiology, CNR San Cataldo Research Area, Via Moruzzi 1, 56124 Pisa, Italy
| | - Serena Del Turco
- Institute of Clinical Physiology, CNR San Cataldo Research Area, Via Moruzzi 1, 56124 Pisa, Italy
| |
Collapse
|
3
|
Wakefield L, Agarwal S, Tanner K. Preclinical models for drug discovery for metastatic disease. Cell 2023; 186:1792-1813. [PMID: 37059072 DOI: 10.1016/j.cell.2023.02.026] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/13/2023] [Accepted: 02/21/2023] [Indexed: 04/16/2023]
Abstract
Despite many advances, metastatic disease remains essentially uncurable. Thus, there is an urgent need to better understand mechanisms that promote metastasis, drive tumor evolution, and underlie innate and acquired drug resistance. Sophisticated preclinical models that recapitulate the complex tumor ecosystem are key to this process. We begin with syngeneic and patient-derived mouse models that are the backbone of most preclinical studies. Second, we present some unique advantages of fish and fly models. Third, we consider the strengths of 3D culture models for resolving remaining knowledge gaps. Finally, we provide vignettes on multiplexed technologies to advance our understanding of metastatic disease.
Collapse
Affiliation(s)
- Lalage Wakefield
- Laboratory of Cancer Biology and Genetics, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD, USA.
| | - Seema Agarwal
- Department of Pathology, Center for Cell Reprogramming, Georgetown University Medical Center, Washington, DC 20007, USA.
| | - Kandice Tanner
- Laboratory of Cell Biology, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD, USA.
| |
Collapse
|
4
|
Zvolský M, Schaar M, Seeger S, Rakers S, Rafecas M. Development of a digital zebrafish phantom and its application to dedicated small-fish PET. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac71ee] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 05/20/2022] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. We are developing a small-fish positron emission tomography (PET) scanner dedicated to small aquatic animals relevant for biomedical and biological research, e.g. zebrafish. We plan to use Monte Carlo simulations to optimize its configuration and the required water-filled imaging chambers. Our objectives were: (1) to create a digital 3D zebrafish phantom using conventional micro-CT, (2) include the phantom into a simulated PET environment based on the framework GATE, and (3) investigate the effects of the water environment on the reconstructed images. Approach. To create the phantom, we performed ex vivo measurements of zebrafish specimen using a tabletop micro-CT and compared three methods to fixate the specimen. From segmented micro-CT images we created digital emission and transmission phantoms which were incorporated in GATE via tessellated volumes. Two chamber sizes were considered. For reference, a simulation with the zebrafish in air was implemented. The simulated data were reconstructed using CASToR. For attenuation correction, we used the exact attenuation information or a uniform distribution (only water). Several realizations of each scenario were performed; the reconstructed images were quantitatively evaluated. Main results. Fixation in formalin led to the best soft-tissue contrast at the cost of some specimen deformation. After attenuation correction, no significant differences were found between the reconstructed images. The PET images reflected well the higher uptake simulated in the brain and heart, despite their small size and surrounding background activity; the swim bladder (no activity) was clearly identified. The simplified attenuation map, consisting only of water, slightly worsened the images. Significance. A conventional micro-CT can provide sufficient image quality to generate numerical phantoms of small fish without contrast media. Such phantoms are useful to evaluate in-silico small aquatic animal imaging concepts and develop imaging protocols. Our results support the feasibility of zebrafish PET with an aqueous environment.
Collapse
|
5
|
Magalhães ACM, Correia PMM, Oliveira RG, Encarnação PMCC, Domingues I, Veloso JFCA, Silva ALM. New Enclosure for in vivo Medical Imaging of Zebrafish With Vital Signs Monitoring. Front Physiol 2022; 13:906110. [PMID: 35846002 PMCID: PMC9278279 DOI: 10.3389/fphys.2022.906110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 05/16/2022] [Indexed: 11/13/2022] Open
Abstract
Lately, the use of zebrafish has gained increased interest in the scientific community as an animal model in preclinical research. However, there is a lack of in vivo imaging tools that ensure animal welfare during acquisition procedures. The use of functional imaging techniques, like Positron Emission Tomography (PET), in zebrafish is limited since it requires the animal to be alive, representing a higher instrumentation complexity when compared to morphological imaging systems. In the present work, a new zebrafish enclosure was developed to acquire in vivo images while monitoring the animal’s welfare through its heartbeat. The temperature, dissolved oxygen, and pH range in a closed aquatic environment were tested to ensure that the conditions stay suitable for animal welfare during image acquisitions. The developed system, based on an enclosure with a bed and heartbeat sensors, was tested under controlled conditions in anesthetized fishes. Since the anesthetized zebrafish do not affect the water quality over time, there is no need to incorporate water circulation for the expected time of PET exams (about 30 min). The range of values obtained for the zebrafish heart rate was 88–127 bpm. The developed system has shown promising results regarding the zebrafish’s heart rate while keeping the fish still during the long imaging exams. The zebrafish enclosure ensures the animal’s well-being during the acquisition of in vivo images in different modalities (PET, Computer Tomography, Magnetic Resonance Imaging), contributing substantially to the preclinical research.
Collapse
Affiliation(s)
| | - P. M. M. Correia
- Department of Physics, I3N, University of Aveiro, Aveiro, Portugal
| | - R. G. Oliveira
- Department of Physics, I3N, University of Aveiro, Aveiro, Portugal
| | | | - I. Domingues
- CESAM, Department of Biology, University of Aveiro, Aveiro, Portugal
| | | | - A. L. M. Silva
- Department of Physics, I3N, University of Aveiro, Aveiro, Portugal
- *Correspondence: A. L. M. Silva,
| |
Collapse
|