PURPOSE
The accurate diagnosis of age-related macular degeneration (AMD) represents an important step in delaying and preventing vision loss and achieving optimal patient care. Therefore, this pilot study aimed to estimate the diagnostic accuracy of community optometrists for identifying AMD using colour fundus photographs (CFPs) to support sample size calculations for subsequent definitive studies.
METHODS
Five practising community optometrists were invited to classify a total of 1023 CFPs for the (1) presence of AMD, and, if applicable, (2) stage of AMD (early/intermediate/late geographic atrophy/late neovascular AMD). Diagnosis by referral centre clinicians formed the reference standard. Diagnostic accuracy was assessed by the area under the receiver operating characteristic curve (aROC). Sensitivity, specificity, positive and negative predictive values were also calculated.
RESULTS
Of the 1023 CFPs included in the study, 226 images were of AMD and 797 images were of other ocular conditions or no abnormal findings. Participating community optometrists had a mean (SD) age of 30.2 (8.9) years, 60.0% (3/5) were female and the mean number of years practising in primary eye care was 5.4 (5.4) years. Community optometrists demonstrated excellent performance for diagnosing AMD, with an aROC of 0.86 (95% CI 0.83 to 0.89), sensitivity of 84.5% (95% CI 79.1 to 89.0) and specificity of 88.0% (95% CI 85.5 to 90.1). The aROC (95% CI) for diagnosing early, intermediate, late geographic atrophy and late neovascular AMD was 0.82 (0.73 to 0.91), 0.76 (0.72 to 0.81), 0.69 (0.49 to 0.90) and 0.55 (0.34 to 0.75), respectively.
CONCLUSIONS
These results justify the need for an appropriately powered definitive study to assess community clinicians' diagnostic accuracy for AMD.