1
|
Vaishnav MS, Pd D, Hegadi SS, C D, Murthy KNC, Srikanta S, Prasad R S. Accelerated microbial identification "directly" from positive blood cultures using MALDI-TOF MS: Local clinical laboratory challenges. Diagn Microbiol Infect Dis 2024; 109:116306. [PMID: 38735146 DOI: 10.1016/j.diagmicrobio.2024.116306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 04/12/2024] [Accepted: 04/12/2024] [Indexed: 05/14/2024]
Abstract
Rapid identification of microbial pathogens "directly" from positive blood cultures (PBCs) is critical for prompt initiation of empirical antibiotic therapy and clinical outcomes. Towards higher microbial identification rates, we modified a published initial serum separator tubes-based MALDI-TOF-MS protocol, for blood culture specimens received at a non-hospital based standalone diagnostic laboratory, Bangalore, India: (a) "Initial" protocol #1: From 28 PBCs, identification= 39% (Gram-negative= 43%: Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa; Gram-positive: 36%: Enterococcus faecalis, Staphylococcus aureus, Staphylococcus haemolyticus); mis-identification= 14%; non-identification= 47%. (b) "Modified" protocol #2: Quality controls (ATCC colonies spiked in negative blood cultures) From 7 analysis, identification= 100% (Escherichia coli, Klebsiella pneumonia, Klebsiella oxytoca, Pseudomonas aeruginosa, Enterococcus faecalis, Staphylococcus aureus); From 7 PBCs, identification= 57%; mis-identification= 14%; non-identification= 29%. Microbial preparations of highest quality and quantity for proteomic analysis and separate spectra matching reference databases for colonies and PBCs are needed for best clinical utility.
Collapse
Affiliation(s)
- Madhumati S Vaishnav
- Neuberg Anand Academy of Laboratory Medicine (NAALM), Bengaluru, India; Samatvam Endocrinology Diabetes Center, Jnana Sanjeevini Diabetes Hospital and Medical Center, Bengaluru, India.
| | - Deepalakshmi Pd
- Neuberg Anand Academy of Laboratory Medicine (NAALM), Bengaluru, India; Neuberg Anand Reference Laboratories (NARL), Bengaluru, India
| | - Sneha S Hegadi
- Neuberg Anand Reference Laboratories (NARL), Bengaluru, India
| | - Divya C
- Neuberg Anand Reference Laboratories (NARL), Bengaluru, India
| | | | - Sathyanarayana Srikanta
- Samatvam Endocrinology Diabetes Center, Jnana Sanjeevini Diabetes Hospital and Medical Center, Bengaluru, India
| | - Sujay Prasad R
- Neuberg Anand Academy of Laboratory Medicine (NAALM), Bengaluru, India; Neuberg Anand Reference Laboratories (NARL), Bengaluru, India
| |
Collapse
|
2
|
Karadağ D, Ergon MC. Investigation of different methods in rapid microbial identification directly from positive blood culture bottles by MALDI-TOF MS. Microbiol Spectr 2024:e0063824. [PMID: 38940589 DOI: 10.1128/spectrum.00638-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Accepted: 05/21/2024] [Indexed: 06/29/2024] Open
Abstract
Many methods are being tried for rapid and accurate identification of sepsis-causing microorganisms. We analyzed the performance of three different preparation methods [MBT Sepsityper IVD Kit (Bruker Daltonics GmbH, Germany), sodium dodecyl sulfate (SDS) lysis, and differential centrifugation with protein extraction (Centrifugation +PE)] and compared in standard and Sepsityper modules of the Bruker Biotyper MALDI-TOF MS for direct identification of bacteria from 240 positive blood culture bottles of BACTEC FX (Becton Dickinson, USA). By using the standard module, correct identification at species level (score ≥2) was done in 46.7% of the samples with SDS lysis, 44.2% with centrifugation +PE, and 25.4% with the Sepsityper kit. These ratios at the genus level (score range 1.70-1.99) were 34.6%, 31.3%, and 32.5%, respectively. With SDS lysis (195), more bacteria were identified correctly than centrifugation +PE (181) and the Sepsityper kit (139). A statistically significant difference was found between SDS and the Sepsityper kit and Centrifugation +PE and the Sepsityper kit (P < 0.001, both). By using the Sepsityper module, correct identification at species level (score ≥1.8) was determined in 74.2% of the samples with SDS lysis and centrifugation +PE each and 55% with the Sepsityper kit. These ratios at the genus level (score range 1.60-1.79) were 16.3%, 10%, and 19.2%, respectively. SDS lysis (217) had significantly higher identification rates than centrifugation +PE (202) and the Sepsityper kit (178) (P = 0.028 and P < 0.001). A statistically significant difference was also observed between centrifugation +PE and the Sepsityper kit (P < 0.001). Best performance was obtained with SDS lysis among the methods. Although better performance was achieved by using Sepsityper software module, risk of misidentification should not be ignored. IMPORTANCE Sepsis is a life-threatening condition, and rapid and accurate identification of the causative microorganisms from blood cultures is crucial for timely and effective treatment. Although there are many studies on direct identification from blood cultures with MALDI-TOF MS, further standardization is still needed. In our study, we analyzed the performance of three different preparation methods and compared by using two analysis modules of the Bruker Biotyper MALDI-TOF MS for direct identification of bacteria from numerous positive blood culture bottles. The literature reports a limited number of studies that compare different preparation methods for direct blood culture identification, processing a large number of blood samples concurrently and evaluating the same samples as in our study. Moreover, although SDS is used very frequently in medical laboratories, there are few studies on direct identification from blood culture bottles. In our study, the highest correct identification rate was observed with the SDS method.
Collapse
Affiliation(s)
- Dilan Karadağ
- Department of Medical Microbiology, Faculty of Medicine, Dokuz Eylül University, İzmir, Turkey
- IMD Labor Oderland, Frankfurt (Oder), Germany
| | - Mahmut Cem Ergon
- Department of Medical Microbiology, Faculty of Medicine, Dokuz Eylül University, İzmir, Turkey
| |
Collapse
|
3
|
Yoo IY, Ha SI, Huh HJ, Kim TY, Shim HJ, Lee H, Kim J, Lee NY, Park YJ. Evaluation of a Modified Protocol for the SepsiPrep Kit for Direct Identification and Antimicrobial Susceptibility Testing From Positive Blood Culture Using BACTEC Plus and BacT/Alert Blood Culture Bottles. Ann Lab Med 2024; 44:183-187. [PMID: 37903653 PMCID: PMC10628748 DOI: 10.3343/alm.2023.0294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 09/07/2023] [Accepted: 10/13/2023] [Indexed: 11/01/2023] Open
Affiliation(s)
- In Young Yoo
- Department of Laboratory Medicine, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Sung Il Ha
- Department of Laboratory Medicine, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Hee Jae Huh
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Tae Yeul Kim
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hyang Jin Shim
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hyeyoung Lee
- Department of Laboratory Medicine, International St. Mary’s Hospital, College of Medicine, Catholic Kwandong University, Incheon, Korea
| | - Jayoung Kim
- Department of Laboratory Medicine, International St. Mary’s Hospital, College of Medicine, Catholic Kwandong University, Incheon, Korea
| | - Nam Yong Lee
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Yeon-Joon Park
- Department of Laboratory Medicine, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| |
Collapse
|
4
|
Xu Y, Song W, Huang P, Mei Y, Zhang Y, Xu T. A Rapid Carbapenemase Genes Detection Method with Xpert Carba-R from Positive Blood Cultures Compared with NG-Test Carba 5 and Sequencing. Infect Drug Resist 2022; 15:7719-7725. [PMID: 36597457 PMCID: PMC9805712 DOI: 10.2147/idr.s392035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Accepted: 12/13/2022] [Indexed: 12/29/2022] Open
Abstract
Objective The objective of the current study was to evaluate the performance of Xpert Carba-R for the direct detection and identification of carbapenemase genes from positive blood cultures. Methods Pathogens which extracted from positive blood cultures and identified using MALDI-TOF MS as Enterobacterales were included in this study. Xpert Carba-R was used for the rapid detection of carbapenemase genes from positive blood cultures. NG-Test CARBA 5 and polymerase-chain reaction (PCR) sequencing were used for the detection of carbapenemases and carbapenemase genes in positive blood culture isolates, respectively. Finally, antibiotic susceptibility tests were conducted using the VITEK-2 Compact system. Results A total of 133 positive blood cultures of Enterobacterales were collected and 27 of them were detected to carry carbapenemase genes using Xpert Carba-R. In comparison with PCR sequencing results, the sensitivity and specificity of Xpert Carba-R and NG-Test CARBA 5 were calculated as 100%. Additionally, Xpert Carba-R could significantly shorten the turnaround time by directly detecting positive blood cultures comparing with NG-Test CARBA 5. For 27 carbapenem-producing strains, the resistance rates of carbapenems and aztreonam were 96.3% and 92.6%, respectively. Strains carrying the blaKPC gene were all sensitive to ceftazidime-avibactam. All strains were sensitive to tigecycline and colistin. Conclusion Xpert Carba-R is suitable for the rapid detection of main carbapenemase genes from positive blood cultures with high sensitivity and specificity. In comparison with NG-Test CARBA 5 and PCR sequencing methods, the timely and convenient method can be a useful test to guide optimal therapy and infection control.
Collapse
Affiliation(s)
- Yuqiao Xu
- Department of Laboratory Medicine, Jiangsu Province Hospital and Nanjing Medical University First Affiliated Hospital, Nanjing, People’s Republic of China,Branch of National Clinical Research Center for Laboratory Medicine, Nanjing, People’s Republic of China
| | - Weijuan Song
- Department of Laboratory Medicine, Jiangsu Province Hospital and Nanjing Medical University First Affiliated Hospital, Nanjing, People’s Republic of China,Branch of National Clinical Research Center for Laboratory Medicine, Nanjing, People’s Republic of China
| | - Peijun Huang
- Department of Laboratory Medicine, Jiangsu Province Hospital and Nanjing Medical University First Affiliated Hospital, Nanjing, People’s Republic of China,Branch of National Clinical Research Center for Laboratory Medicine, Nanjing, People’s Republic of China
| | - Yaning Mei
- Department of Laboratory Medicine, Jiangsu Province Hospital and Nanjing Medical University First Affiliated Hospital, Nanjing, People’s Republic of China,Branch of National Clinical Research Center for Laboratory Medicine, Nanjing, People’s Republic of China
| | - Yan Zhang
- Department of Laboratory Medicine, Jiangsu Province Hospital and Nanjing Medical University First Affiliated Hospital, Nanjing, People’s Republic of China,Branch of National Clinical Research Center for Laboratory Medicine, Nanjing, People’s Republic of China,Correspondence: Yan Zhang; Ting Xu, Department of Laboratory Medicine, Jiangsu Province Hospital, Guangzhou Street No. 300, Nanjing, 210029, People’s Republic of China, Tel +8625-6830-6287, Fax +8625- 8372-4440, Email ;
| | - Ting Xu
- Department of Laboratory Medicine, Jiangsu Province Hospital and Nanjing Medical University First Affiliated Hospital, Nanjing, People’s Republic of China,Branch of National Clinical Research Center for Laboratory Medicine, Nanjing, People’s Republic of China
| |
Collapse
|
5
|
Sepsityper ® Kit versus In-House Method in Rapid Identification of Bacteria from Positive Blood Cultures by MALDI-TOF Mass Spectrometry. Life (Basel) 2022; 12:life12111744. [PMID: 36362899 PMCID: PMC9693840 DOI: 10.3390/life12111744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 10/24/2022] [Accepted: 10/28/2022] [Indexed: 11/16/2022] Open
Abstract
In order to further accelerate pathogen identification from positive blood cultures (BC), various sample preparation protocols to identify bacteria with MALDI-TOF MS directly from positive BCs have been developed. We evaluated an in-house method in comparison to the Sepsityper® Kit (Bruker Daltonics, Bremen, Germany) as well as the benefit of an on-plate formic acid extraction step following positive signal by the BACTECTM FX system. Confirmation of identification was achieved using subcultured growing biomass used for MALDI-TOF MS analysis. A total of 113 monomicrobial positive BCs were analyzed. The rates of Gram-positive bacteria correctly identified to the genus level using in-house method and Sepsityper® Kit were 63.3% (38/60) and 81.7% (49/60), respectively (p = 0.025). Identification rates at species level for Gram-positive bacteria with in-house method and Sepsityper® kit were 30.0% (18/60) and 66.7% (40/60), respectively (p < 0.001). Identification rates of Gram-negative bacteria were similar with the in-house method and Sepsityper® Kit. Additional on-plate formic acid extraction demonstrated significant improvement in the identification rate of Gram-positive bacteria at both genus and species level for both in-house (p = 0.001, p < 0.001) and Sepsityper® Kit methods (p = 0.007, p < 0.001). Our in-house method is a candidate for laboratory routines with Sepsityper® Kit as a back-up solution when identification of Gram-positive bacteria is unsuccessful.
Collapse
|
6
|
Gassiep I, Bauer MJ, Harris PNA, Norton R. Speed and safety of mass spectrometry for identification of Burkholderia pseudomallei directly from spiked blood cultures. J Med Microbiol 2022; 71. [PMID: 35451940 DOI: 10.1099/jmm.0.001521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Burkholderia pseudomallei is a bipolar Gram-negative bacillus and the causative agent of melioidosis; an infectious disease which commonly presents with bacteraemia. Data regarding direct from blood culture identification of B. pseudomallei using the Vitek mass spectrometer (MS) are limited. The authors aim to assess the safety and sensitivity of the Vitek MS for identification of B. pseudomallei from spiked positive blood culture samples. Safety was assessed by determining the ability of the standard MS α-cyano-4-hydroxycinnamic acid (CHCA) matrix solution to inactivate B. pseudomallei. Organism identification using the manufacturer's blood culture extraction method was compared to an in-house technique. Additionally, identification following abbreviated agar incubation of blood culture broth was performed. All 70 MS target spots were inactivated by the matrix solution. The manufacturer's blood culture extraction method identified 0/26 (0%) B. pseudomallei samples. An in-house method using the spun deposit from blood culture broth samples identified 38/38 (100%) B. pseudomallei samples. MS analysis of a blood culture broth drop on Chocolate agar following a 6 h incubation identified 30/32 (94%) samples. Decreased time to diagnosis of melioidosis bacteraemia is likely to improve patient outcomes. This study adds to the literature with regards to the utility of MALDI-TOF MS identification of B. pseudomallei both directly from positive blood culture broth and a subsequent 6 h plate incubation. The use of a standard matrix solution inactivates the organism, and use of the spun deposit from a positive blood culture broth is most effective for early identification of B. pseudomallei.
Collapse
Affiliation(s)
- Ian Gassiep
- University of Queensland Centre for Clinical Research, Royal Brisbane and Woman's Hospital, Herston, Queensland, Australia.,Department of Infectious Diseases, Mater Hospital Brisbane, South Brisbane, Queensland, Australia.,Pathology Queensland, Royal Brisbane & Women's Hospital, Herston, Queensland, Australia
| | - Michelle J Bauer
- University of Queensland Centre for Clinical Research, Royal Brisbane and Woman's Hospital, Herston, Queensland, Australia
| | - Patrick N A Harris
- University of Queensland Centre for Clinical Research, Royal Brisbane and Woman's Hospital, Herston, Queensland, Australia.,Pathology Queensland, Royal Brisbane & Women's Hospital, Herston, Queensland, Australia
| | - Robert Norton
- Pathology Queensland, Townsville University Hospital, Townsville, Queensland, Australia.,Faculty of Medicine, University of Queensland, Brisbane, Queensland, Australia
| |
Collapse
|
7
|
Rebrosova K, Samek O, Kizovsky M, Bernatova S, Hola V, Ruzicka F. Raman Spectroscopy—A Novel Method for Identification and Characterization of Microbes on a Single-Cell Level in Clinical Settings. Front Cell Infect Microbiol 2022; 12:866463. [PMID: 35531343 PMCID: PMC9072635 DOI: 10.3389/fcimb.2022.866463] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 03/07/2022] [Indexed: 12/02/2022] Open
Abstract
Rapid and accurate identification of pathogens causing infections is one of the biggest challenges in medicine. Timely identification of causative agents and their antimicrobial resistance profile can significantly improve the management of infection, lower costs for healthcare, mitigate ever-growing antimicrobial resistance and in many cases, save lives. Raman spectroscopy was shown to be a useful—quick, non-invasive, and non-destructive —tool for identifying microbes from solid and liquid media. Modifications of Raman spectroscopy and/or pretreatment of samples allow single-cell analyses and identification of microbes from various samples. It was shown that those non-culture-based approaches could also detect antimicrobial resistance. Moreover, recent studies suggest that a combination of Raman spectroscopy with optical tweezers has the potential to identify microbes directly from human body fluids. This review aims to summarize recent advances in non-culture-based approaches of identification of microbes and their virulence factors, including antimicrobial resistance, using methods based on Raman spectroscopy in the context of possible use in the future point-of-care diagnostic process.
Collapse
Affiliation(s)
- Katarina Rebrosova
- Department of Microbiology, Faculty of Medicine of Masaryk University and St. Anne’s University Hospital, Brno, Czechia
| | - Ota Samek
- Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czechia
| | - Martin Kizovsky
- Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czechia
| | - Silvie Bernatova
- Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czechia
| | - Veronika Hola
- Department of Microbiology, Faculty of Medicine of Masaryk University and St. Anne’s University Hospital, Brno, Czechia
- *Correspondence: Veronika Hola,
| | - Filip Ruzicka
- Department of Microbiology, Faculty of Medicine of Masaryk University and St. Anne’s University Hospital, Brno, Czechia
| |
Collapse
|
8
|
MALDI-Based Mass Spectrometry in Clinical Testing: Focus on Bacterial Identification. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12062814] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
The term “proteome” refers to the total of all proteins expressed in an organism. The term “proteomics” refers to the field of research that includes not only information on the expression levels of individual proteins, but also their higher-order structures, intermolecular interactions, and post-translational modifications. The core technology, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), is available for protein analysis thanks to the work of Koichi Tanaka and John Fenn, who were awarded the Nobel Prize in Chemistry in 2002. The most successful proteome analysis in clinical practice is rapid microbial identification. This method determines the bacterial species by comparing the proteome profile of the bacteria obtained by matrix-assisted laser desorption ionization-time of flight MS (MALDI-TOF MS) with a database. MS is superior in simplicity, speed, and accuracy to classic speciation by staining and phenotyping. In clinical microbiology, MS has had a large impact on the diagnosis and treatment of infectious disease. Early diagnosis and treatment of infectious disease are important, and rapid identification by MALDI-TOF MS has made a major contribution to this field.
Collapse
|
9
|
Sun B, Kang X, Yue S, Lan L, Li R, Chen C, Zhang W, He S, Zhang C, Fan Y, Wang P, Zheng G, Hong W. A rapid procedure for bacterial identification and antimicrobial susceptibility testing directly from positive blood cultures. Analyst 2021; 147:147-154. [PMID: 34860216 DOI: 10.1039/d1an01210j] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
There is an urgent need to develop a rapid procedure that can rapidly identify and obtain antimicrobial susceptibility testing (AST) results directly from positive blood cultures. Here, we report a semi-automatic bacterial diagnosis procedure, which includes (1) a bacterial concentration process to isolate bacteria from a positive blood culture bottle (PBCB), (2) an identification process using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), and (3) a rapid AST process based on stimulated Raman scattering imaging of deuterium oxide (D2O) incorporation in bacteria. A total of 105 samples were tested for bacterial identification, and a bacterial identification accuracy of 92.3% was achieved. AST takes about 2.5 h after identification. This semi-automatic procedure only takes 3.5 h, which is demonstrated to be the fastest process to obtain identification and AST results starting from PBCBs.
Collapse
Affiliation(s)
- Bo Sun
- Institute of Medical Photonics, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China. .,Laboratory Diagnosis Center, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
| | - Xixiong Kang
- Laboratory Diagnosis Center, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
| | - Shuhua Yue
- Institute of Medical Photonics, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| | - Lu Lan
- Vibronix Inc., West Lafayette, IN, USA
| | - Rui Li
- Vibronix Inc., West Lafayette, IN, USA
| | - Chen Chen
- Institute of Medical Photonics, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| | - Weifeng Zhang
- Institute of Medical Photonics, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| | - Shipei He
- Institute of Medical Photonics, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| | - Chenxi Zhang
- Laboratory Diagnosis Center, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
| | - Yubo Fan
- Institute of Medical Photonics, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China. .,School of Medical Science and Engineering, Beihang University, Beijing, China
| | - Pu Wang
- Institute of Medical Photonics, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| | - Guanghui Zheng
- Laboratory Diagnosis Center, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
| | - Weili Hong
- Institute of Medical Photonics, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| |
Collapse
|
10
|
Puckett LM, Rajkotia P, Coppola L, Baumgartner L, Roberts AL, Maldonado Y, Girotto JE. Impact of Direct From Blood Culture Identification of Pathogens Paired With Antimicrobial Stewardship Interventions in a Pediatric Hospital. J Pediatr Pharmacol Ther 2021; 26:802-808. [PMID: 34790069 DOI: 10.5863/1551-6776-26.8.802] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 02/17/2021] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Identification of organisms directly from positive blood culture by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has the potential for improved clinical outcomes through earlier organism identification and shorter time to appropriate clinical intervention. The uses of this technology in pediatric patients and its impact in this patient population have not been well described. METHODS Direct from positive blood culture organism identification via MALDI-TOF was implemented in September 2019. A quality improvement project was performed to assess its impact on admissions for contaminant blood cultures and time to effective and optimal antimicrobials and clinical decision-making. A pre- and post-implementation retrospective review for consecutive September through February time periods, was conducted on patients with positive monomicrobial blood cultures. Statistics were evaluated using Mann-Whitney U and χ2 tests. RESULTS One hundred nineteen patients with 131 unique blood cultures (65 in pre- and 66 in post-implementation) were identified. Time to identification was shorter, median 35.4 hours (IQR, 22.7-54.3) versus 42.3 hours (IQR, 36.5-49) in post- and pre-groups, respectively (p = 0.02). Patients were less likely to be admitted for a contaminated blood culture in the post-implementation, 26% versus 11% in the pre-implementation (p = 0.03) group. In patients treated for bacteremia, there was a shorter time to optimal therapy from Gram stain reporting in the post-implementation (median 42.7 hours [IQR, 27.2-72]) versus pre-implementation (median 60.8 hours [IQR, 42.9-80.6]) (p = 0.03). CONCLUSIONS Direct from positive blood culture identification by MALDI-TOF decreased time to effective and optimal antimicrobials and decreased unnecessary admission in pediatric patients for contaminated blood cultures.
Collapse
|
11
|
Chen XF, Hou X, Xiao M, Zhang L, Cheng JW, Zhou ML, Huang JJ, Zhang JJ, Xu YC, Hsueh PR. Matrix-Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS) Analysis for the Identification of Pathogenic Microorganisms: A Review. Microorganisms 2021; 9:microorganisms9071536. [PMID: 34361971 PMCID: PMC8304613 DOI: 10.3390/microorganisms9071536] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 07/03/2021] [Accepted: 07/10/2021] [Indexed: 12/13/2022] Open
Abstract
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been used in the field of clinical microbiology since 2010. Compared with the traditional technique of biochemical identification, MALDI-TOF MS has many advantages, including convenience, speed, accuracy, and low cost. The accuracy and speed of identification using MALDI-TOF MS have been increasing with the development of sample preparation, database enrichment, and algorithm optimization. MALDI-TOF MS has shown promising results in identifying cultured colonies and rapidly detecting samples. MALDI-TOF MS has critical research applications for the rapid detection of highly virulent and drug-resistant pathogens. Here we present a scientific review that evaluates the performance of MALDI-TOF MS in identifying clinical pathogenic microorganisms. MALDI-TOF MS is a promising tool in identifying clinical microorganisms, although some aspects still require improvement.
Collapse
Affiliation(s)
- Xin-Fei Chen
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Xin Hou
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Meng Xiao
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Li Zhang
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Jing-Wei Cheng
- Center of Clinical Laboratory, Beijing Friendship Hospital, Capital Medical University, Beijing 100053, China;
| | - Meng-Lan Zhou
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Jing-Jing Huang
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Jing-Jia Zhang
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Ying-Chun Xu
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
- Correspondence: (Y.-C.X.); (P.-R.H.)
| | - Po-Ren Hsueh
- Departments of Laboratory Medicine and Internal Medicine, China Medical University Hospital, School of Medicine, China Medical University, Taichung 40447, Taiwan;
- Departments of Laboratory Medicine and Internal Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei 100, Taiwan
- Correspondence: (Y.-C.X.); (P.-R.H.)
| |
Collapse
|
12
|
Wang G, Song G, Xu Y. A Rapid Antimicrobial Susceptibility Test for Klebsiella pneumoniae Using a Broth Micro-Dilution Combined with MALDI TOF MS. Infect Drug Resist 2021; 14:1823-1831. [PMID: 34025124 PMCID: PMC8132464 DOI: 10.2147/idr.s305280] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Accepted: 04/22/2021] [Indexed: 12/27/2022] Open
Abstract
Background Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) is a novel method that can be used to identify pathogens and has potential applications in the detection of drug-resistant bacteria. Purpose To evaluate the ability of a MALDI-TOF MS-based broth micro-dilution method in detecting the minimum inhibitory concentration (MIC) values of Klebsiella pneumoniae to ceftriaxone and imipenem. Materials and Methods Sixty strains of K. pneumoniae with different levels of resistance to carbapenems and cephalosporins were randomly collected. The 0.5 McFarland (Mc) concentration of the bacterial suspension was inoculated in cation-adjusted Mueller-Hinton broth (CAMHB) with a final cell turbidity of 5×105 CFU/mL. The broth was incubated with serial concentrations of antibiotics. After centrifuging the bacterial suspensions, the lysed cells were analyzed by MALDI-TOF MS to identify the growth-promoting or inhibitory effects on K. pneumoniae. The molecular mechanisms of resistance were investigated by PCR and DNA sequencing analysis. Results The expression of known resistance genes (blaKPC, blaFOX, blaDHA, blaCTX-M and blaTEM) was detected in the 30 carbapenems-resistant strains. The agreement between the MIC values derived from the MALDI-TOF MS analysis and from the broth micro-dilution method was 61.7% for ceftriaxone and 71.7% for imipenem. According to the Clinical and Laboratory Standards Institute (CLSI) breakpoint of resistance to ceftriaxone and imipenem, the 60 isolates were accurately classified as resistant or susceptible isolates with 100% sensitivity and 100% specificity. Conclusion The transmission and infection of multidrug-resistant bacteria could be better managed and treated with the rapid identification of strains and antimicrobial susceptibility. A MALDI-TOF MS-based susceptibility test could be used to identify resistance of K. pneumoniae within a short time-frame. This approach could potentially be used as a supplementary antimicrobial susceptibility test that could be investigated on more bacterial species combined with different antibiotics.
Collapse
Affiliation(s)
- Gang Wang
- Department of Clinical Laboratory, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui Province, People's Republic of China
| | - Guobin Song
- Department of Clinical Laboratory, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui Province, People's Republic of China.,Department of Clinical Laboratory, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, People's Republic of China
| | - Yuanhong Xu
- Department of Clinical Laboratory, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui Province, People's Republic of China
| |
Collapse
|
13
|
Zhou M, Wu Y, Kudinha T, Jia P, Wang L, Xu Y, Yang Q. Comprehensive Pathogen Identification, Antibiotic Resistance, and Virulence Genes Prediction Directly From Simulated Blood Samples and Positive Blood Cultures by Nanopore Metagenomic Sequencing. Front Genet 2021; 12:620009. [PMID: 33841495 PMCID: PMC8024499 DOI: 10.3389/fgene.2021.620009] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 02/08/2021] [Indexed: 12/11/2022] Open
Abstract
Bloodstream infection is a major cause of morbidity and mortality worldwide. We explored whether MinION nanopore sequencing could accelerate diagnosis, resistance, and virulence profiling prediction in simulated blood samples and blood cultures. One milliliter of healthy blood samples each from direct spike (sample 1), anaerobic (sample 2), and aerobic (sample 3) blood cultures with initial inoculation of ∼30 CFU/ml of a clinically isolated Klebsiella pneumoniae strain was subjected to DNA extraction and nanopore sequencing. Hybrid assembly of Illumina and nanopore reads from pure colonies of the isolate (sample 4) was used as a reference for comparison. Hybrid assembly of the reference genome identified a total of 39 antibiotic resistance genes and 77 virulence genes through alignment with the CARD and VFDB databases. Nanopore correctly detected K. pneumoniae in all three blood samples. The fastest identification was achieved within 8 h from specimen to result in sample 1 without blood culture. However, direct sequencing in sample 1 only identified seven resistance genes (20.6%) but 28 genes in samples 2–4 (82.4%) compared to the reference within 2 h of sequencing time. Similarly, 11 (14.3%) and 74 (96.1%) of the virulence genes were detected in samples 1 and 2–4 within 2 h of sequencing time, respectively. Direct nanopore sequencing from positive blood cultures allowed comprehensive pathogen identification, resistance, and virulence genes prediction within 2 h, which shows its promising use in point-of-care clinical settings.
Collapse
Affiliation(s)
- Menglan Zhou
- Department of Clinical Laboratory, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Yarong Wu
- Beijing Applied Biological Technologies Co., Ltd., Beijing, China
| | - Timothy Kudinha
- School of Biomedical Sciences, Charles Sturt University, Orange, NSW, Australia.,Pathology West, NSW Health Pathology, Orange, NSW, Australia
| | - Peiyao Jia
- Department of Clinical Laboratory, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China.,Graduate School, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Lei Wang
- Beijing Applied Biological Technologies Co., Ltd., Beijing, China
| | - Yingchun Xu
- Department of Clinical Laboratory, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Qiwen Yang
- Department of Clinical Laboratory, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| |
Collapse
|
14
|
Recent Development of Rapid Antimicrobial Susceptibility Testing Methods through Metabolic Profiling of Bacteria. Antibiotics (Basel) 2021; 10:antibiotics10030311. [PMID: 33803002 PMCID: PMC8002737 DOI: 10.3390/antibiotics10030311] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 03/07/2021] [Accepted: 03/08/2021] [Indexed: 11/17/2022] Open
Abstract
Due to the inappropriate use and overuse of antibiotics, the emergence and spread of antibiotic-resistant bacteria are increasing and have become a major threat to human health. A key factor in the treatment of bacterial infections and slowing down the emergence of antibiotic resistance is to perform antimicrobial susceptibility testing (AST) of infecting bacteria rapidly to prescribe appropriate drugs and reduce the use of broad-spectrum antibiotics. Current phenotypic AST methods based on the detection of bacterial growth are generally reliable but are too slow. There is an urgent need for new methods that can perform AST rapidly. Bacterial metabolism is a fast process, as bacterial cells double about every 20 to 30 min for fast-growing species. Moreover, bacterial metabolism has shown to be related to drug resistance, so a comparison of differences in microbial metabolic processes in the presence or absence of antimicrobials provides an alternative approach to traditional culture for faster AST. In this review, we summarize recent developments in rapid AST methods through metabolic profiling of bacteria under antibiotic treatment.
Collapse
|
15
|
Jadhav SR, Shah RM, Palombo EA. MALDI-ToF MS: A Rapid Methodology for Identifying and Subtyping Listeria monocytogenes. Methods Mol Biol 2021; 2220:17-29. [PMID: 32975763 DOI: 10.1007/978-1-0716-0982-8_2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Listeria monocytogenes is a major food-borne pathogen and causative agent of a fatal disease, listeriosis. Stringent regulatory guidelines and zero tolerance policy toward this bacterium necessitate rapid, accurate, and reliable methods of identification and subtyping. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) has recently become a method of choice for routine identification of pathogens in clinical settings and has largely replaced biochemical assays. Identification relies on well-curated databases such as SARAMIS. Extensive use of SARAMIS to generate consensus mass spectra, in conjunction with statistical analysis, such as partial least square-discriminant analysis and hierarchical cluster analysis, is useful in subtyping bacteria. While MALDI-ToF MS has been extensively used for pathogen detection, its application in bacterial subtyping has been limited. The protocol describes a MALDI-ToF MS workflow as a single tool for simultaneous identification and subtyping of L. monocytogenes directly from solid culture medium.
Collapse
Affiliation(s)
- Snehal R Jadhav
- Centre for Advanced Sensory Science, School of Exercise and Nutrition Sciences, Deakin University, Melbourne, VIC, Australia.
- Department of Chemistry and Biotechnology, Swinburne University of Technology, Melbourne, VIC, Australia.
| | - Rohan M Shah
- Department of Chemistry and Biotechnology, Swinburne University of Technology, Melbourne, VIC, Australia
| | - Enzo A Palombo
- Department of Chemistry and Biotechnology, Swinburne University of Technology, Melbourne, VIC, Australia.
| |
Collapse
|
16
|
K. Hussain K, Malavia D, M. Johnson E, Littlechild J, Winlove CP, Vollmer F, Gow NAR. Biosensors and Diagnostics for Fungal Detection. J Fungi (Basel) 2020; 6:E349. [PMID: 33302535 PMCID: PMC7770582 DOI: 10.3390/jof6040349] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 12/02/2020] [Accepted: 12/02/2020] [Indexed: 12/14/2022] Open
Abstract
Early detection is critical to the successful treatment of life-threatening infections caused by fungal pathogens, as late diagnosis of systemic infection almost always equates with a poor prognosis. The field of fungal diagnostics has some tests that are relatively simple, rapid to perform and are potentially suitable at the point of care. However, there are also more complex high-technology methodologies that offer new opportunities regarding the scale and precision of fungal diagnosis, but may be more limited in their portability and affordability. Future developments in this field are increasingly incorporating new technologies provided by the use of new format biosensors. This overview provides a critical review of current fungal diagnostics and the development of new biophysical technologies that are being applied for selective new sensitive fungal biosensors to augment traditional diagnostic methodologies.
Collapse
Affiliation(s)
- Khalil K. Hussain
- Medical Research Council Centre for Medical Mycology, University of Exeter, Geoffrey Pope Building, Stocker Road, Exeter EX4 4QD, UK; (D.M.); (E.M.J.)
| | - Dhara Malavia
- Medical Research Council Centre for Medical Mycology, University of Exeter, Geoffrey Pope Building, Stocker Road, Exeter EX4 4QD, UK; (D.M.); (E.M.J.)
| | - Elizabeth M. Johnson
- Medical Research Council Centre for Medical Mycology, University of Exeter, Geoffrey Pope Building, Stocker Road, Exeter EX4 4QD, UK; (D.M.); (E.M.J.)
- UK National Mycology Reference Laboratory (MRL), Public Health England South-West, Science Quarter Southmead Hospital, Southmead, Bristol BS10 5NB, UK
| | - Jennifer Littlechild
- Biocatalysis Centre, University of Exeter, The Henry Wellcome Building for Biocatalysis, Stocker Road, Exeter EX4 4QD, UK;
| | - C. Peter Winlove
- Department of Physics and Astronomy, College of Engineering, Mathematics and Physical Sciences, University of Exeter, Exeter EX4 4QD, UK;
| | - Frank Vollmer
- Living Systems Institute, University of Exeter, Stocker Road, Exeter EX4 4QD, UK;
| | - Neil A. R. Gow
- Medical Research Council Centre for Medical Mycology, University of Exeter, Geoffrey Pope Building, Stocker Road, Exeter EX4 4QD, UK; (D.M.); (E.M.J.)
| |
Collapse
|
17
|
Tsuchida S, Umemura H, Nakayama T. Current Status of Matrix-Assisted Laser Desorption/Ionization-Time-of-Flight Mass Spectrometry (MALDI-TOF MS) in Clinical Diagnostic Microbiology. Molecules 2020; 25:molecules25204775. [PMID: 33080897 PMCID: PMC7587594 DOI: 10.3390/molecules25204775] [Citation(s) in RCA: 78] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 10/15/2020] [Accepted: 10/15/2020] [Indexed: 12/28/2022] Open
Abstract
Mass spectrometry (MS), a core technology for proteomics and metabolomics, is currently being developed for clinical applications. The identification of microorganisms in clinical samples using matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry (MALDI-TOF MS) is a representative MS-based proteomics application that is relevant to daily clinical practice. This technology has the advantages of convenience, speed, and accuracy when compared with conventional biochemical methods. MALDI-TOF MS can shorten the time used for microbial identification by about 1 day in routine workflows. Sample preparation from microbial colonies has been improved, increasing the accuracy and speed of identification. MALDI-TOF MS is also used for testing blood, cerebrospinal fluid, and urine, because it can directly identify the microorganisms in these liquid samples without prior culture or subculture. Thus, MALDI-TOF MS has the potential to improve patient prognosis and decrease the length of hospitalization and is therefore currently considered an essential tool in clinical microbiology. Furthermore, MALDI-TOF MS is currently being combined with other technologies, such as flow cytometry, to expand the scope of clinical applications.
Collapse
|
18
|
Kuo FC, Chien CC, Lee MS, Wang JW, Lin PC, Lee CH. Rapid diagnosis of periprosthetic joint infection from synovial fluid in blood culture bottles by direct matrix-assisted laser desorption ionization time-of-flight mass spectrometry. PLoS One 2020; 15:e0239290. [PMID: 32970712 PMCID: PMC7515592 DOI: 10.1371/journal.pone.0239290] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Accepted: 09/03/2020] [Indexed: 11/18/2022] Open
Abstract
Background The aim of this prospective study was to use direct matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) to rapidly diagnose periprosthetic joint infections (PJIs). Method Synovial fluid was taken from 77 patients (80 joints, 41 hips and 39 knees) who met the International Consensus Meeting criteria for PJI, and inoculated into blood culture bottles (BCBs) and onto conventional swabs. Positive blood cultures were analyzed using either direct or routine MALDI-TOF MS. Pathogen identification and the time to identification was recorded. Differences between groups were analyzed using the Kruskal-Wallis test and Bonferroni's post-hoc test. Results Direct and routine MALDI-TOF MS both detected 64 positive results (80%), compared to 47 (59%) by conventional swabs (p = 0.002). Direct MALDI-TOF MS identified 85.3% of the gram-positive organisms and 92.3% of the gram-negative organisms. No fungi were identified by direct MALDI-TOF MS. In 17 BCBs that were flagged positive, identification by direct MALDI-TOF MS failed. Among the positive results in the direct MALDI-TOF MS group, Staphylococcus aureus accounted for 47%, followed by Staphylococcus epidermidis (17%), Escherichia coli (9%) and Klebsiella pneumoniae (9%). The median time to microorganism identification was significantly shorter with direct MALDI-TOF MS (12.7 h, IQR: 8.9–19.6 h) than with routine MALDI-TOF MS (39.5 h, IQR: 22.8–46.0 h) or swabs (44.4 h, IQR: 27.2–72.6 h) (p < 0.0001). In pairwise comparisons, there were significant differences in the time of microorganism identification between direct MALDI-TOF MS and routine MALDI-TOF MS (p < 0.0001) or swab culture (p < 0.0001). There was no significant difference between routine MALDI-TOF MS and swab culture (p = 0.0268). Conclusion Compared with current laboratory practice, direct MALDI-TOF MS shortened the time to microorganism identification and had superior results compared to conventional swabs, except for fungi. Further studies should investigate whether the earlier administration of appropriate antimicrobial agents can improve the treatment outcomes of PJIs.
Collapse
Affiliation(s)
- Feng-Chih Kuo
- Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
- College of Medicine, Chang Gung University, Kaohsiung, Taiwan
| | - Chun-Chih Chien
- Laboratory Medicine, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
| | - Mel S. Lee
- Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
- College of Medicine, Chang Gung University, Kaohsiung, Taiwan
| | - Jun-Wen Wang
- Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
- College of Medicine, Chang Gung University, Kaohsiung, Taiwan
| | - Po-Chun Lin
- Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
- College of Medicine, Chang Gung University, Kaohsiung, Taiwan
| | - Chen-Hsiang Lee
- College of Medicine, Chang Gung University, Kaohsiung, Taiwan
- Division of Infectious Diseases, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
- * E-mail:
| |
Collapse
|
19
|
Time to Positivity as a Prognostic Tool in the Performance of Short-Term Subculture for MALDI-TOF MS-Based Identification of Microorganisms from Positive Blood Cultures in Pediatric Patients. Curr Microbiol 2020; 77:953-958. [DOI: 10.1007/s00284-020-01900-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Accepted: 01/21/2020] [Indexed: 10/25/2022]
|
20
|
Rapid identification of microorganisms from positive blood cultures in pediatric patients by MALDI-TOF MS: Sepsityper kit versus short-term subculture. J Microbiol Methods 2020; 172:105894. [PMID: 32184161 DOI: 10.1016/j.mimet.2020.105894] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 03/13/2020] [Accepted: 03/13/2020] [Indexed: 01/18/2023]
Abstract
BACKGROUND AND AIM The rapid diagnosis of bloodstream infection (BSI) often leads to better clinical outcomes. The present study was conducted to compare two rapid protocols (Sepsityper kit and short-term subculture) for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based identification of microorganisms from positive blood cultures in pediatric patients. METHODS This study was conducted between May 1, 2018, and April 30, 2019, at a tertiary children's hospital in eastern China. Only monomicrobial blood cultures included in this study were used to conduct the Sepsityper kit protocol and short-term subculture protocol at the same time. RESULTS In total, 115 monomicrobial blood cultures were included in this study. For the Sepsityper kit protocol, 85.2% and 64.3% of microorganisms were correctly identified to the genus (score ≥ 1.700) and species levels (score ≥ 2.000), respectively. For the short-term subculture protocol, 89.6% and 70.4% of microorganisms were correctly identified to the genus and species levels, respectively. At the genus level (P = .321) or the species level (P = .325), there was no significant difference between the Sepsityper kit protocol and the short-term subculture protocol. Moreover, the short-term subculture protocol exhibited similar performance between Gram-positive bacteria (GPB) and Gram-negative bacteria (GNB) (the genus level: 93.7% (GPB) versus 87.9% (GNB), P = .518; the species level: 68.4% (GPB) versus 81.8% (GNB), P = .147). In addition, the Sepsityper kit protocol exhibited similar performance between GPB and GNB at the genus level (86.1% (GPB) versus 84.8% (GNB), P = 1.000). However, the Sepsityper kit protocol exhibited better performance in GNB at the species level (58.2% (GPB) versus 81.8% (GNB), P = .017). The rates of yeast-like fungi were correctly identified to the genus level (0.0%) or the species level (0.0%) for short-term subculture protocol were significantly lower than those of other microorganisms (the genus level: 92.0%, P = .001; the species level: 72.3%, P = .024). However, a similar result of identification was not found using the Sepsityper kit protocol (the genus level: P = .384; the species level: P = .599). In addition, the two rapid protocols both exhibited better performance at the genus level when the time to positivity (TTP) of blood cultures <19 h (the Sepsityper kit protocol: 91.8% (TTP < 19 h) versus 77.8% (TTP ≥ 19 h), P = .034; the short-term subculture protocol: 95.1% (TTP < 19 h) versus 83.3% (TTP ≥ 19 h), P = .040). In addition, the two rapid protocols both exhibited better performance at the species level when the TTP of blood cultures was <19 h (the Sepsityper kit protocol: 78.7% (TTP < 19 h) versus 48.1% (TTP ≥ 19 h), P = .000; the short-term subculture protocol: 83.6% (TTP < 19 h) versus 55.6% (TTP ≥ 19 h), P = .001). CONCLUSION The Sepsityper kit protocol and short-term subculture protocol are both reliable and rapid methods for the identification of most microorganisms from positive blood cultures in pediatric patients. The performance of these two rapid protocols is associated with the TTP of blood cultures.
Collapse
|
21
|
Nix ID, Idelevich EA, Storck LM, Sparbier K, Drews O, Kostrzewa M, Becker K. Detection of Methicillin Resistance in Staphylococcus aureus From Agar Cultures and Directly From Positive Blood Cultures Using MALDI-TOF Mass Spectrometry-Based Direct-on-Target Microdroplet Growth Assay. Front Microbiol 2020; 11:232. [PMID: 32117194 PMCID: PMC7033577 DOI: 10.3389/fmicb.2020.00232] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Accepted: 01/31/2020] [Indexed: 11/26/2022] Open
Abstract
Matrix-assisted laser desorption/ionization time-of-flight-mass spectrometry (MALDI-TOF MS)-based direct-on-target microdroplet growth assay (DOT-MGA) was recently described as a novel method of phenotypic antimicrobial susceptibility testing (AST). Here, we developed the application of MALDI-TOF MS-based DOT-MGA for Gram-positive bacteria including AST from agar cultures and directly from positive blood cultures (BCs) using the detection of methicillin resistance as example. Consecutively collected, a total of 14 methicillin-resistant Staphylococcus aureus (MRSA) and 14 methicillin-susceptible S. aureus (MSSA) clinical isolates were included. Furthermore, a collection of MRSA challenge strains comprising different SCCmec types, mec genes, and spa types was tested. Blood samples were spiked with MRSA and MSSA and positive BC broth processed by three different methods: serial dilution of BC broth, lysis/centrifugation, and differential centrifugation. Processed BC broth was directly used for rapid AST using DOT-MGA. Droplets of 6 μl with and without cefoxitin at the EUCAST breakpoint concentration were spotted in triplicates onto the surface of a MALDI target. Targets were incubated in a humidity chamber, followed by medium removal and on-target protein extraction with formic acid before adding matrix with an internal standard as a quality control (QC). Spectra were acquired and evaluated using MALDI Biotyper software. First, tests were considered as valid, if the growth control achieved an identification score of ≥1.7. For valid tests, same score criterion was used for resistant isolates when incubated with cefoxitin. An identification score <1.7 after incubation with cefoxitin defined susceptible isolates. On-target protein extraction using formic acid considerably improved detection of methicillin resistance in S. aureus and DOT-MGA showed feasible results for AST from agar cultures after 4 h incubation time. Comparing the different processing methods of positive BC broth, lysis/centrifugation method with a final dilution step 10–1 of the 0.5 McFarland suspension resulted in best test performance after 4 h incubation time. Overall, 96.4% test validity, 100% sensitivity, and 100% specificity were achieved for detection of methicillin resistance in clinical isolates. All strains of the MRSA challenge collection were successfully tested as methicillin-resistant. This first study on Gram-positive organisms showed feasibility and accuracy of MALDI-TOF MS-based DOT-MGA for rapid AST of S. aureus from agar cultures and directly from positive BCs.
Collapse
Affiliation(s)
- Ilka D Nix
- Institute of Medical Microbiology, University Hospital Münster, Münster, Germany
| | - Evgeny A Idelevich
- Institute of Medical Microbiology, University Hospital Münster, Münster, Germany
| | - Luise M Storck
- Institute of Medical Microbiology, University Hospital Münster, Münster, Germany
| | | | | | | | - Karsten Becker
- Institute of Medical Microbiology, University Hospital Münster, Münster, Germany.,Friedrich Loeffler-Institute of Medical Microbiology, University Medicine Greifswald, Greifswald, Germany
| |
Collapse
|
22
|
Samaranayake WAMP, Dempsey S, Howard-Jones AR, Outhred AC, Kesson AM. Rapid direct identification of positive paediatric blood cultures by MALDI-TOF MS technology and its clinical impact in the paediatric hospital setting. BMC Res Notes 2020; 13:12. [PMID: 31907060 PMCID: PMC6945395 DOI: 10.1186/s13104-019-4861-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Accepted: 12/14/2019] [Indexed: 01/13/2023] Open
Abstract
OBJECTIVE Rapid diagnostic tools are imperative for timely clinical decision making, particularly in bacteraemic patients. This study evaluated the performance of a fast, inexpensive novel in house method for processing positive blood cultures for immediate identification of microorganisms by matrix-assisted laser desorption ionization-time of flight mass spectrometry (Vitek MS bioMérieux). We prospectively analyzed the clinical impact of such method on the management of pediatric patients. RESULT In total, 360 positive blood cultures were included. Among 318 mono-microbial cultures, in-house method achieved correct identification in 270 (85%) cultures to the species level, whilst 43 (13.5%) gave no identification, and 7 (2.2%) gave discordant identifications. Identification of Gram-negative organisms was accurate to both species and genus level in 99% of isolates, and for Gram positives accuracy was 84% to genus and 81% to species level overall, with accuracy of 100% for Staphylococcus aureus and Enterococcus to the species level. Assessment of the potential impact of direct identification in sixty sequential cases revealed a clear clinical benefit in 35.5% of cases. Benefits included timely antibiotic rationalization, change of medical intervention, and early confirmation of contamination. This study demonstrates a highly accurate in-house method with considerable potential clinical benefits for paediatric care.
Collapse
Affiliation(s)
| | - Suzanne Dempsey
- Department of Infectious Diseases and Microbiology, The Children's Hospital at Westmead, Sydney, Australia
| | - Annaleise R Howard-Jones
- Department of Infectious Diseases and Microbiology, The Children's Hospital at Westmead, Sydney, Australia
| | - Alexander Conrad Outhred
- Department of Infectious Diseases and Microbiology, The Children's Hospital at Westmead, Sydney, Australia.,The Marie Bashir Institute of Infectious Diseases and Biosecurity, The University of Sydney, Sydney, Australia
| | - Alison Margaret Kesson
- Department of Infectious Diseases and Microbiology, The Children's Hospital at Westmead, Sydney, Australia.,The Marie Bashir Institute of Infectious Diseases and Biosecurity, The University of Sydney, Sydney, Australia.,Discipline of Child and Adolescent Health, The University of Sydney, Sydney, Australia
| |
Collapse
|
23
|
Florio W, Cappellini S, Giordano C, Vecchione A, Ghelardi E, Lupetti A. A new culture-based method for rapid identification of microorganisms in polymicrobial blood cultures by MALDI-TOF MS. BMC Microbiol 2019; 19:267. [PMID: 31783786 PMCID: PMC6884914 DOI: 10.1186/s12866-019-1641-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 11/14/2019] [Indexed: 12/11/2022] Open
Abstract
Background The application of matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) mass spectrometry (MS) to microbial identification has allowed the development of rapid methods for identification of microorganisms directly in positive, blood cultures (BCs). These methods can yield accurate results for monomicrobial BCs, but often fail to identify multiple microorganisms in polymicrobial BCs. The present study was aimed at establishing a rapid and simple method for identification of bacteria and yeast in polymicrobial BCs from patients with bloodstream infection. Results The rapid method herein proposed is based on short-term culture in liquid media allowing selective growth of microorganisms recovered from polymicrobial BCs, followed by rapid identification by MALDI-TOF MS. To evaluate the accuracy of this method, 56 polymicrobial BCs were comparatively analyzed with the rapid and routine methods. The results showed concordant identification for both microbial species in 43/50 (86%) BCs containing two different microorganisms, and for two microbial species in six BCs containing more than two different species. Overall, 102/119 (85.7%) microorganisms were concordantly identified by the rapid and routine methods using a cut-off value of 1.700 for valid identification. The mean time to identification after BC positivity was about 4.2 h for streptococci/enterococci, 8.7 h for staphylococci, 11.1 h for Gram-negative bacteria, and 14.4 h for yeast, allowing a significant time saving compared to the routine method. Conclusions The proposed method allowed rapid and reliable microbial identification in polymicrobial BCs, and could provide clinicians with timely, useful information to streamline empirical antimicrobial therapy in critically ill patients.
Collapse
Affiliation(s)
- Walter Florio
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università di Pisa, Via San Zeno 37, 56127, Pisa, Italy
| | - Susanna Cappellini
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università di Pisa, Via San Zeno 37, 56127, Pisa, Italy
| | - Cesira Giordano
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università di Pisa, Via San Zeno 37, 56127, Pisa, Italy
| | - Alessandra Vecchione
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università di Pisa, Via San Zeno 37, 56127, Pisa, Italy
| | - Emilia Ghelardi
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università di Pisa, Via San Zeno 37, 56127, Pisa, Italy
| | - Antonella Lupetti
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università di Pisa, Via San Zeno 37, 56127, Pisa, Italy.
| |
Collapse
|
24
|
Rapid detection of silkworm microsporidia by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. J Invertebr Pathol 2019; 166:107223. [PMID: 31356820 DOI: 10.1016/j.jip.2019.107223] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 07/23/2019] [Accepted: 07/26/2019] [Indexed: 11/20/2022]
Abstract
Microsporidia cause the disease pébrine in silkworm and are known to be detrimental to sericulture and beekeeping. The microsporidian species Nosema bombycis was rapidly identified in silkworm (Bombyx mori) using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Four types of microsporidian spores purified from infected silkworm could be distinguished based on the differences in their mass fingerprints. Microsporidia growing in a silkworm larva were also identified based on their mass spectra after rapid separation using filtration and centrifugation for 30 min.
Collapse
|
25
|
Bryson AL, Hill EM, Doern CD. Matrix-Assisted Laser Desorption/Ionization Time-of-Flight: The Revolution in Progress. Clin Lab Med 2019; 39:391-404. [PMID: 31383264 DOI: 10.1016/j.cll.2019.05.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
This article summarizes recent advances in the application of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) to new areas of infectious diseases diagnostics. We discuss progress toward routine identification of mycobacteria and filamentous fungi and direct identification of pathogens from clinical specimens. Of greatest interest is the use of MALDI-TOF MS for identifying organisms from positive blood cultures and from clinical specimens such as urine. Last, We highlight some exciting new possibilities for MALDI-TOF MS phenotypic susceptibility testing for bacteria and yeast.
Collapse
Affiliation(s)
- Alexandra L Bryson
- Department of Pathology, Virginia Commonwealth University Health System, 403 North 13th Street, Richmond, VA 23298, USA
| | - Emily M Hill
- Pathology & Laboratory Medicine, Hunter Holmes McGuire VA Medical Center, 1201 Broad Rock Boulevard, Richmond, VA 23224, USA
| | - Christopher D Doern
- Department of Pathology, Virginia Commonwealth University Health System, 403 North 13th Street, Richmond, VA 23298, USA.
| |
Collapse
|
26
|
Xu S, Zhou C, Zhang P, Feng C, Zhang T, Sun Z, Zhuang H, Chen H, Chang Q, Jiang R, Li H, Ni Y. Diagnostic Performance of MALDI-TOF MS Compared to Conventional Microbiological Cultures in Patients with Suspected Endophthalmitis. Ocul Immunol Inflamm 2019; 28:483-490. [PMID: 31116624 DOI: 10.1080/09273948.2019.1583346] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Purpose: To evaluate the performance and speed of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) when identifying the pathogenic microorganism of endophthalmitis compared to conventional microbiological culturing.Methods: Forty-four patients with suspected endophthalmitis who had undergone vitrectomy were enrolled. Vitreous specimen was analyzed using either conventional culturing or MALDI-TOF MS.Results: The identification rates of the conventional microbiological culture and MALDI-TOF MS were 45.5% (20/44) and 65.9% (29/44), respectively (Kappa value 0.787, P < 0.000). The mean detection times by the standard culturing method and MALDI-TOF MS were 5.39 ± 0.56d and 3.17 ± 0.40d (P < 0.001). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MALDI-TOF MS were 70.59%, 54.17%, 80.00%, and 86.67%, respectively. Polymicrobial endophthalmitis was identified in 6.82% of the patients (3/44) using conventional microbiological culturing. However, MALDI-TOF MS failed to identify any polymicrobial infection.Conclusions: With a higher sensitivity, acceptable specificity and a shorter detection time, MALDI-TOF MS was an efficient technique for the rapid identification of a pathogenic microorganism in endophthalmitis.
Collapse
Affiliation(s)
- Sisi Xu
- Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Chunmei Zhou
- Department of Pulmonary Medicine, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Peijun Zhang
- Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Chaoyi Feng
- Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Ting Zhang
- Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Zhongcui Sun
- Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Hong Zhuang
- Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Han Chen
- Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Qing Chang
- Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Rui Jiang
- Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Huayin Li
- Department of Pulmonary Medicine, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Yingqin Ni
- Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| |
Collapse
|
27
|
Simon L, Ughetto E, Gaudart A, Degand N, Lotte R, Ruimy R. Direct Identification of 80 Percent of Bacteria from Blood Culture Bottles by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Using a 10-Minute Extraction Protocol. J Clin Microbiol 2019; 57:e01278-18. [PMID: 30463897 PMCID: PMC6355546 DOI: 10.1128/jcm.01278-18] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Accepted: 11/13/2018] [Indexed: 12/18/2022] Open
Abstract
Matrix-assisted laser desorption ionization-time of flight mass spectrometry is not widely used to identify bacteria directly from positive blood culture bottles (BCBs) because of overlong protocols. The objective of this work was to develop and evaluate a simple extraction protocol for reliable identification from BCBs. The 10-min protocol was applied over a 5-month period. Direct identifications on day 0 were compared with those obtained from colonies on day 1 [log(score) of ≥2]. We evaluated a range of seven log(score) thresholds on day 0 from 1.4 to 2.0 to find the lower confidence score that provides the higher percentage of direct identifications without loss of accuracy. With a log(score) threshold of ≥1.5 at day 0, our protocol allowed us to identify 80% of bacteria in 632 BCBs (96% of Enterobacteriaceae, 95% of Staphylococcus aureus, 92% of enterococci, and 62% of streptococci). At least one bacterial species of the mixture was identified in 77% of the polymicrobial samples. The rapidity and reliability of the protocol were factors in its adoption for routine use, allowing us to save up to 24 h in identifying 80% of the bacteria in the BCBs and, thus, to supply useful information to adapt antibiotic therapy when necessary. We currently provide reliable daily direct identifications of staphylococci, enterococci, Enterobacteriaceae, Pseudomonas aeruginosa, and beta-hemolytic streptococci.
Collapse
Affiliation(s)
- Loïc Simon
- Laboratoire de Bactériologie, CHU de Nice, Hôpital de l'Archet 2, Nice, France
| | - Estelle Ughetto
- Laboratoire de Bactériologie, CHU de Nice, Hôpital de l'Archet 2, Nice, France
| | - Alice Gaudart
- Laboratoire de Bactériologie, CHU de Nice, Hôpital de l'Archet 2, Nice, France
| | - Nicolas Degand
- Laboratoire de Bactériologie, CHU de Nice, Hôpital de l'Archet 2, Nice, France
| | - Romain Lotte
- Laboratoire de Bactériologie, CHU de Nice, Hôpital de l'Archet 2, Nice, France
- Université Côte d'Azur, Nice, France
- INSERM U1065, C3M, Equipe 6 Virulence Microbienne et Signalisation Inflammatoire, Bâtiment Universitaire Archimed, Nice, France
| | - Raymond Ruimy
- Laboratoire de Bactériologie, CHU de Nice, Hôpital de l'Archet 2, Nice, France
- Université Côte d'Azur, Nice, France
- INSERM U1065, C3M, Equipe 6 Virulence Microbienne et Signalisation Inflammatoire, Bâtiment Universitaire Archimed, Nice, France
| |
Collapse
|
28
|
Dubourg G, Raoult D, Fenollar F. Emerging methodologies for pathogen identification in bloodstream infections: an update. Expert Rev Mol Diagn 2019; 19:161-173. [DOI: 10.1080/14737159.2019.1568241] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
| | - Didier Raoult
- Aix Marseille Univ, IRD, AP-HM, MEPHI, Marseille, France
| | | |
Collapse
|
29
|
Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for the Rapid Detection of Antimicrobial Resistance Mechanisms and Beyond. Clin Microbiol Rev 2018; 32:32/1/e00037-18. [PMID: 30487165 DOI: 10.1128/cmr.00037-18] [Citation(s) in RCA: 67] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been successfully applied in recent years for first-line identification of pathogens in clinical microbiology because it is simple to use, rapid, and accurate and has economic benefits in hospital management. The range of clinical applications of MALDI-TOF MS for bacterial isolates is increasing constantly, from species identification to the two most promising applications in the near future: detection of antimicrobial resistance and strain typing for epidemiological studies. The aim of this review is to outline the contribution of previous MALDI-TOF MS studies in relation to detection of antimicrobial resistance and to discuss potential future challenges in this field. Three main approaches are ready (or almost ready) for clinical use, including the detection of antibiotic modifications due to the enzymatic activity of bacteria, the detection of antimicrobial resistance by analysis of the peak patterns of bacteria or mass peak profiles, and the detection of resistance by semiquantification of bacterial growth in the presence of a given antibiotic. This review provides an expert guide for MALDI-TOF MS users to new approaches in the field of antimicrobial resistance detection, especially possible applications as a routine diagnostic tool in microbiology laboratories.
Collapse
|
30
|
Huang YL, Sun QL, Li JP, Hu YY, Zhou HW, Zhang R. Evaluation of an in-house MALDI-TOF MS rapid diagnostic method for direct identification of micro-organisms from blood cultures. J Med Microbiol 2018; 68:41-47. [PMID: 30418107 DOI: 10.1099/jmm.0.000866] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
PURPOSE Bloodstream infections are major causes of morbidity and mortality among hospitalized patients worldwide. Early identification of micro-organisms from blood culture can facilitate earlier optimization of treatment. The objective of this study was to assess an in-house method based on a new matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) platform (Clin-TOF MS) for direct organism identification. METHODOLOGY We studied the performance of the in-house method for direct identification and the conventional sub-culture method in parallel. Identification from subcultures was analysed with Bruker MS as the reference method. RESULTS A total of 666 blood cultures with a single micro-organism that flagged positive after no more than a 3-day incubation period were collected. The identification accuracy of the in-house Clin-TOF MS method for direct identification and the sub-culture method was 88.6 and 100 %, respectively. The in-house method exhibited better performance for Gram-negative bacteria than for Gram-positive bacteria (93.3 vs 81.6 %). The accuracy rate for anaerobes was 100 % (3/3). The lowest accurate identification rate was for yeast; this was only 20 %. Lytic Anaerobic/F (LAF) and Plus Aerobic/F (PAF) provided the highest accurate identification rates, and it was noteworthy that the accuracy rate for FAN Aerobic (FA) was 82 %, which is higher than previously reported and showed that the method was effective. CONCLUSION Our study provides an effective sample preparation method for the direct identification of pathogens from positive blood culture vials via Clin-TOF MS at a very low cost of about $0.5 per sample and with a short turnaround time of about 20 min. This will help clinicians make precise diagnoses and provide targeted prescriptions, reducing the risk of the potential development of resistance.
Collapse
Affiliation(s)
- Yong-Lu Huang
- Department of Clinical Laboratory, School of Medicine, Second Affiliated Hospital of Zhejiang University, Hangzhou 310009, PR China
| | - Qiao-Ling Sun
- Department of Clinical Laboratory, School of Medicine, Second Affiliated Hospital of Zhejiang University, Hangzhou 310009, PR China
| | - Jia-Ping Li
- Department of Clinical Laboratory, School of Medicine, Second Affiliated Hospital of Zhejiang University, Hangzhou 310009, PR China
| | - Yan-Yan Hu
- Department of Clinical Laboratory, School of Medicine, Second Affiliated Hospital of Zhejiang University, Hangzhou 310009, PR China
| | - Hong-Wei Zhou
- Department of Clinical Laboratory, School of Medicine, Second Affiliated Hospital of Zhejiang University, Hangzhou 310009, PR China
| | - Rong Zhang
- Department of Clinical Laboratory, School of Medicine, Second Affiliated Hospital of Zhejiang University, Hangzhou 310009, PR China
| |
Collapse
|
31
|
Luethy PM, Johnson JK. The Use of Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) for the Identification of Pathogens Causing Sepsis. J Appl Lab Med 2018; 3:675-685. [PMID: 31639735 DOI: 10.1373/jalm.2018.027318] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Accepted: 08/09/2018] [Indexed: 12/15/2022]
Abstract
BACKGROUND Sepsis is a life-threatening condition with high rates of morbidity and mortality; effective and appropriate antibiotic therapy is essential for ensuring patient improvement. To aid in the diagnosis of sepsis, blood cultures are drawn and sent to the microbiology laboratory for pathogen growth, identification, and susceptibility testing. The clinical microbiology laboratory can assist the medical team by providing timely identification of the pathogen(s) causing the bloodstream infection through the use of rapid diagnostic technology. One of these rapid diagnostic technologies, MALDI-TOF MS, has been proven to reduce the time required for appropriate antibiotic therapy when used to identify pathogens grown in culture. This technology has also been used to identify pathogens directly from the positive blood cultures with great success. CONTENT In this minireview, we summarize the different methods that have been developed to directly identify pathogens from positive blood cultures by use of MALDI-TOF MS and the effect of this technology on patient outcomes. Additionally, we touch on current research in the field, including the identification of antimicrobial resistance directly from positive blood cultures by MALDI-TOF MS. SUMMARY Rapid identification of pathogens is important in the survival of patients undergoing a septic event. MALDI-TOF MS technology has played an important role in rapid identification, which has led to a reduction in the time to appropriate antibiotic therapy and contributed to the improvement of patient outcomes. The high sensitivity and specificity of MALDI-TOF MS identification, in combination with MALDI-TOF's rapid function and reduced labor costs, make this technology an attractive choice for clinical laboratories.
Collapse
Affiliation(s)
- Paul M Luethy
- Department of Pathology, University of Maryland School of Medicine, Baltimore, MD
| | - J Kristie Johnson
- Department of Pathology, University of Maryland School of Medicine, Baltimore, MD.
| |
Collapse
|
32
|
Shannon S, Kronemann D, Patel R, Schuetz AN. Routine use of MALDI-TOF MS for anaerobic bacterial identification in clinical microbiology. Anaerobe 2018; 54:191-196. [PMID: 30541686 DOI: 10.1016/j.anaerobe.2018.07.001] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Revised: 06/19/2018] [Accepted: 07/02/2018] [Indexed: 12/14/2022]
Abstract
In 2013, we adopted MALDI-TOF MS using the Bruker Biotyper system for identification of anaerobic bacteria into our routine clinical practice. Here, we describe our experience with the use of MALDI-TOF MS for anaerobic bacterial identification, highlighting its value in replacing the more costly and time-consuming 16S ribosomal RNA gene PCR plus sequencing-based approach as the primary method of anaerobic bacterial identification. We also describe our more recent experience with the use of early/rapid MALDI-TOF MS for identification of anaerobic bacteria performed on short incubation (4-6 h) plated aerobic media from anaerobic blood culture bottles positive for Gram-negative bacilli.
Collapse
Affiliation(s)
- Samantha Shannon
- Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA.
| | - Daniel Kronemann
- Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA.
| | - Robin Patel
- Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA; Division of Infectious Diseases, Department of Medicine, Mayo Clinic, Rochester, MN, USA.
| | - Audrey N Schuetz
- Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
33
|
Pan HW, Li W, Li RG, Li Y, Zhang Y, Sun EH. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures. Front Microbiol 2018; 9:481. [PMID: 29616003 PMCID: PMC5869256 DOI: 10.3389/fmicb.2018.00481] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Accepted: 02/28/2018] [Indexed: 11/13/2022] Open
Abstract
Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in <15 min. The correct rate of direct MALDI-TOF MS identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.
Collapse
Affiliation(s)
- Hong-Wei Pan
- Department of Clinical Laboratory, Qilu Hospital of Shandong University, Jinan, China
| | - Wei Li
- Department of Clinical Laboratory, Qilu Hospital of Shandong University, Jinan, China
| | - Rong-Guo Li
- Department of Clinical Laboratory, Jinan Maternal and Child Care Hospital, Jinan, China
| | - Yong Li
- Department of Clinical Laboratory, Qilu Hospital of Shandong University, Jinan, China
| | - Yi Zhang
- Department of Clinical Laboratory, Qilu Hospital of Shandong University, Jinan, China
| | - En-Hua Sun
- Department of Clinical Laboratory, Qilu Hospital of Shandong University, Jinan, China
| |
Collapse
|