1
|
Wu Q, Wang Z, Chen Y. sEMG-Based Adaptive Cooperative Multi-Mode Control of a Soft Elbow Exoskeleton Using Neural Network Compensation. IEEE Trans Neural Syst Rehabil Eng 2023; 31:3384-3396. [PMID: 37590115 DOI: 10.1109/tnsre.2023.3306201] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/19/2023]
Abstract
Soft rehabilitation exoskeletons have gained much attention in recent years, striving to assist the paralyzed individuals restore motor functions. However, it is a challenge to promote human-robot interaction property and satisfy personalized training requirements. This article proposes a soft elbow rehabilitation exoskeleton for the multi-mode training of disabled patients. An adaptive cooperative admittance backstepping control strategy combined with surface electromyography (sEMG)-based joint torque estimation and neural network compensation is developed, which can induce the active participation of patients and guarantee the accomplishment and safety of training. The proposed control scheme can be transformed into four rehabilitation training modes to optimize the cooperative training performance. Experimental studies involving four healthy subjects and four paralyzed subjects are carried out. The average root mean square error and peak error in trajectory tracking test are 3.18° and 5.68°. The active cooperation level can be adjusted via admittance model, ranging from 4.51 °/Nm to 10.99 °/Nm. In cooperative training test, the average training mode value and effort score of healthy subjects (i.e., 1.58 and 1.50) are lower than those of paralyzed subjects (i.e., 2.42 and 3.38), while the average smoothness score and stability score of healthy subjects (i.e., 3.25 and 3.42) are higher than those of paralyzed subjects (i.e., 1.67 and 1.71). The experimental results verify the superiority of proposed control strategy in improving position control performance and satisfying the training requirements of the patients with different hemiplegia degrees and training objectives.
Collapse
|
2
|
Jayakumar A, Rodríguez Jorge D, Bermejo-García J, Agujetas R, Romero-Sánchez F. Sensing and Control Strategies for a Synergy-Based, Cable-Driven Exosuit via a Modular Test Bench. SENSORS (BASEL, SWITZERLAND) 2023; 23:4713. [PMID: 37430634 DOI: 10.3390/s23104713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 05/10/2023] [Accepted: 05/10/2023] [Indexed: 07/12/2023]
Abstract
Ageing results in the eventual loss of muscle mass and strength, joint problems, and overall slowing of movements, with a greater risk of suffering falls or other such accidents. The use of gait assistance exoskeletons can help in the active aging of this segment of the population. Given the user specificity of the mechanics and control these devices need, the facility used to test different design parameters is indispensable. This work deals with the modeling and construction of a modular test bench and prototype exosuit to test different mounting and control schemes for a cable-driven exoskeleton or exosuit. The test bench allows the experimental implementation of postural or kinematic synergies to assist multiple joints by using only one actuator and the optimization of the control scheme to better adapt to the characteristics of the specific patient. The design is open to the research community and it is expected to improve the design of cable-driven systems for exosuits.
Collapse
Affiliation(s)
- Ashwin Jayakumar
- Departamento de Ingeniería Mecánica, Energética y de los Materiales, Escuela de Ingenierías Industriales, Universidad de Extremadura, Avda. de Elvas S/N, 06006 Badajoz, Spain
| | - Daniel Rodríguez Jorge
- Departamento de Ingeniería Mecánica, Energética y de los Materiales, Escuela de Ingenierías Industriales, Universidad de Extremadura, Avda. de Elvas S/N, 06006 Badajoz, Spain
| | - Javier Bermejo-García
- Departamento de Ingeniería Mecánica, Energética y de los Materiales, Escuela de Ingenierías Industriales, Universidad de Extremadura, Avda. de Elvas S/N, 06006 Badajoz, Spain
| | - Rafael Agujetas
- Departamento de Ingeniería Mecánica, Energética y de los Materiales, Escuela de Ingenierías Industriales, Universidad de Extremadura, Avda. de Elvas S/N, 06006 Badajoz, Spain
| | - Francisco Romero-Sánchez
- Departamento de Ingeniería Mecánica, Energética y de los Materiales, Escuela de Ingenierías Industriales, Universidad de Extremadura, Avda. de Elvas S/N, 06006 Badajoz, Spain
| |
Collapse
|
3
|
Ang BWK, Yeow CH, Lim JH. A Critical Review on Factors Affecting the User Adoption of Wearable and Soft Robotics. SENSORS (BASEL, SWITZERLAND) 2023; 23:3263. [PMID: 36991974 PMCID: PMC10051244 DOI: 10.3390/s23063263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 03/06/2023] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
In recent years, the advent of soft robotics has changed the landscape of wearable technologies. Soft robots are highly compliant and malleable, thus ensuring safe human-machine interactions. To date, a wide variety of actuation mechanisms have been studied and adopted into a multitude of soft wearables for use in clinical practice, such as assistive devices and rehabilitation modalities. Much research effort has been put into improving their technical performance and establishing the ideal indications for which rigid exoskeletons would play a limited role. However, despite having achieved many feats over the past decade, soft wearable technologies have not been extensively investigated from the perspective of user adoption. Most scholarly reviews of soft wearables have focused on the perspective of service providers such as developers, manufacturers, or clinicians, but few have scrutinized the factors affecting adoption and user experience. Hence, this would pose a good opportunity to gain insight into the current practice of soft robotics from a user's perspective. This review aims to provide a broad overview of the different types of soft wearables and identify the factors that hinder the adoption of soft robotics. In this paper, a systematic literature search using terms such as "soft", "robot", "wearable", and "exoskeleton" was conducted according to PRISMA guidelines to include peer-reviewed publications between 2012 and 2022. The soft robotics were classified according to their actuation mechanisms into motor-driven tendon cables, pneumatics, hydraulics, shape memory alloys, and polyvinyl chloride muscles, and their pros and cons were discussed. The identified factors affecting user adoption include design, availability of materials, durability, modeling and control, artificial intelligence augmentation, standardized evaluation criteria, public perception related to perceived utility, ease of use, and aesthetics. The critical areas for improvement and future research directions to increase adoption of soft wearables have also been highlighted.
Collapse
Affiliation(s)
- Benjamin Wee Keong Ang
- Department of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore; (B.W.K.A.); (C.-H.Y.)
| | - Chen-Hua Yeow
- Department of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore; (B.W.K.A.); (C.-H.Y.)
| | - Jeong Hoon Lim
- Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119074, Singapore
- Division of Rehabilitation Medicine, University Medicine Cluster, National University Hospital, Singapore 119077, Singapore
| |
Collapse
|
4
|
Yilmaz AF, Khalilbayli F, Ozlem K, Elmoughni HM, Kalaoglu F, Atalay AT, Ince G, Atalay O. Effect of Segment Types on Characterization of Soft Sensing Textile Actuators for Soft Wearable Robots. Biomimetics (Basel) 2022; 7:biomimetics7040249. [PMID: 36546949 PMCID: PMC9776281 DOI: 10.3390/biomimetics7040249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 12/13/2022] [Accepted: 12/13/2022] [Indexed: 12/23/2022] Open
Abstract
The use of textiles in soft robotics is gaining popularity because of the advantages textiles offer over other materials in terms of weight, conformability, and ease of manufacture. The purpose of this research is to examine the stitching process used to construct fabric-based pneumatic bending actuators as well as the effect of segment types on the actuators' properties when used in soft robotic glove applications. To impart bending motion to actuators, two techniques have been used: asymmetry between weave and weft knit fabric layers and mechanical anisotropy between these two textiles. The impacts of various segment types on the actuators' grip force and bending angle were investigated further. According to experiments, segmenting the actuator with a sewing technique increases the bending angle. It was discovered that actuators with high anisotropy differences in their fabric combinations have high gripping forces. Textile-based capacitive strain sensors are also added to selected segmented actuator types, which possess desirable properties such as increased grip force, increased bending angle, and reduced radial expansion. The sensors were used to demonstrate the controllability of a soft robotic glove using a closed-loop system. Finally, we demonstrated that actuators integrated into a soft wearable glove are capable of grasping a variety of items and performing various grasp types.
Collapse
Affiliation(s)
- Ayse Feyza Yilmaz
- Faculty of Textile Technologies and Design, Textile Engineering Department, Istanbul Technical University, Istanbul 34437, Turkey
| | - Fidan Khalilbayli
- Faculty of Computer and Informatics Engineering, Computer Engineering Department, Istanbul Technical University, Istanbul 34469, Turkey
| | - Kadir Ozlem
- Faculty of Computer and Informatics Engineering, Computer Engineering Department, Istanbul Technical University, Istanbul 34469, Turkey
| | - Hend M. Elmoughni
- Faculty of Textile Technologies and Design, Textile Engineering Department, Istanbul Technical University, Istanbul 34437, Turkey
| | - Fatma Kalaoglu
- Faculty of Textile Technologies and Design, Textile Engineering Department, Istanbul Technical University, Istanbul 34437, Turkey
| | - Asli Tuncay Atalay
- Faculty of Technology, Textile Engineering Department, Marmara University, Istanbul 34854, Turkey
| | - Gökhan Ince
- Faculty of Computer and Informatics Engineering, Computer Engineering Department, Istanbul Technical University, Istanbul 34469, Turkey
| | - Ozgur Atalay
- Faculty of Textile Technologies and Design, Textile Engineering Department, Istanbul Technical University, Istanbul 34437, Turkey
- Correspondence:
| |
Collapse
|
5
|
Shi Y, Dong W, Lin W, Gao Y. Soft Wearable Robots: Development Status and Technical Challenges. SENSORS (BASEL, SWITZERLAND) 2022; 22:7584. [PMID: 36236683 PMCID: PMC9573304 DOI: 10.3390/s22197584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/25/2022] [Accepted: 10/03/2022] [Indexed: 06/16/2023]
Abstract
In recent years, more and more research has begun to focus on the flexible and lightweight design of wearable robots. During this process, many novel concepts and achievements have been continuously made and shown to the public, while new problems have emerged at the same time, which need to be solved. In this paper, we give an overview of the development status of soft wearable robots for human movement assistance. On the basis of a clear definition, we perform a system classification according to the target assisted joint and attempt to describe the overall prototype design level in related fields. Additionally, it is necessary to sort out the latest research progress of key technologies such as structure, actuation, control and evaluation, thereby analyzing the design ideas and basic characteristics of them. Finally, we discuss the possible application fields, and propose the main challenges of this valuable research direction.
Collapse
Affiliation(s)
| | | | | | - Yongzhuo Gao
- State Key Laboratory of Robotics and System, Harbin Institute of Technology (HIT), Harbin 150001, China
| |
Collapse
|
6
|
Bardi E, Gandolla M, Braghin F, Resta F, Pedrocchi ALG, Ambrosini E. Upper limb soft robotic wearable devices: a systematic review. J Neuroeng Rehabil 2022; 19:87. [PMID: 35948915 PMCID: PMC9367113 DOI: 10.1186/s12984-022-01065-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 07/21/2022] [Indexed: 11/29/2022] Open
Abstract
INTRODUCTION Soft robotic wearable devices, referred to as exosuits, can be a valid alternative to rigid exoskeletons when it comes to daily upper limb support. Indeed, their inherent flexibility improves comfort, usability, and portability while not constraining the user's natural degrees of freedom. This review is meant to guide the reader in understanding the current approaches across all design and production steps that might be exploited when developing an upper limb robotic exosuit. METHODS The literature research regarding such devices was conducted in PubMed, Scopus, and Web of Science. The investigated features are the intended scenario, type of actuation, supported degrees of freedom, low-level control, high-level control with a focus on intention detection, technology readiness level, and type of experiments conducted to evaluate the device. RESULTS A total of 105 articles were collected, describing 69 different devices. Devices were grouped according to their actuation type. More than 80% of devices are meant either for rehabilitation, assistance, or both. The most exploited actuation types are pneumatic (52%) and DC motors with cable transmission (29%). Most devices actuate 1 (56%) or 2 (28%) degrees of freedom, and the most targeted joints are the elbow and the shoulder. Intention detection strategies are implemented in 33% of the suits and include the use of switches and buttons, IMUs, stretch and bending sensors, EMG and EEG measurements. Most devices (75%) score a technology readiness level of 4 or 5. CONCLUSION Although few devices can be considered ready to reach the market, exosuits show very high potential for the assistance of daily activities. Clinical trials exploiting shared evaluation metrics are needed to assess the effectiveness of upper limb exosuits on target users.
Collapse
Affiliation(s)
- Elena Bardi
- Department of Mechanical Engineering, Politecnico di Milano, Milano, Italy
| | - Marta Gandolla
- Department of Mechanical Engineering, Politecnico di Milano, Milano, Italy
| | - Francesco Braghin
- Department of Mechanical Engineering, Politecnico di Milano, Milano, Italy
| | - Ferruccio Resta
- Department of Mechanical Engineering, Politecnico di Milano, Milano, Italy
| | | | - Emilia Ambrosini
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| |
Collapse
|
7
|
Jeong J, Hyeon K, Jang SY, Chung C, Hussain S, Ahn SY, Bok SK, Kyung KU. Soft Wearable Robot With Shape Memory Alloy (SMA)-Based Artificial Muscle for Assisting With Elbow Flexion and Forearm Supination/Pronation. IEEE Robot Autom Lett 2022. [DOI: 10.1109/lra.2022.3161700] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
8
|
Force and Torque Characterization in the Actuation of a Walking-Assistance, Cable-Driven Exosuit. SENSORS 2022; 22:s22114309. [PMID: 35684930 PMCID: PMC9185532 DOI: 10.3390/s22114309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 05/29/2022] [Accepted: 06/04/2022] [Indexed: 11/29/2022]
Abstract
Soft exosuits stand out when it comes to the development of walking-assistance devices thanks to both their higher degree of wearability, lower weight, and price compared to the bulkier equivalent rigid exoskeletons. In cable-driven exosuits, the acting force is driven by cables from the actuation system to the anchor points; thus, the user’s movement is not restricted by a rigid structure. In this paper, a 3D inverse dynamics model is proposed and integrated with a model for a cable-driven actuation to predict the required motor torque and traction force in cables for a walking-assistance exosuit during gait. Joint torques are to be shared between the user and the exosuit for different design configurations, focusing on both hip and ankle assistance. The model is expected to guide the design of the exosuit regarding aspects such as the location of the anchor points, the cable system design, and the actuation units. An inverse dynamics analysis is performed using gait kinematic data from a public dataset to predict the cable forces and position of the exosuit during gait. The obtained joint reactions and cable forces are compared with those in the literature, and prove the model to be accurate and ready to be implemented in an exosuit control scheme. The results obtained in this study are similar to those found in the literature regarding the walking study itself as well as the forces under which cables operate during gait and the cable position cycle.
Collapse
|
9
|
Kadivar Z, Beck CE, Rovekamp RN, O'Malley MK. Single limb cable driven wearable robotic device for upper extremity movement support after traumatic brain injury. J Rehabil Assist Technol Eng 2021; 8:20556683211002448. [PMID: 34123404 PMCID: PMC8175840 DOI: 10.1177/20556683211002448] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Accepted: 02/24/2021] [Indexed: 11/24/2022] Open
Abstract
Introduction Recently, soft exosuits have been proposed for upper limb movement assistance, most supporting single joint movements. We describe the design of a portable wearable robotic device (WRD), “Armstrong,” able to support three degrees-of-freedom of arm movements, and report on its feasibility for movement support of individuals with hemiparesis after traumatic brain injury (TBI). Methods We introduce Armstrong and report on a pilot evaluation with two male individuals post-TBI (T1 and T2) and two healthy individuals. Testing involved elbow flexion/extension with and without robotic-assisted shoulder stabilization; shoulder abduction with and without robotic-assisted elbow stabilization; and assisted shoulder abduction and flexion. Outcome measures included range of motion and root mean square trajectory and velocity errors. Results TBI subjects performed active, passive, hybrid and active assistive movements with Armstrong. Subjects showed improvements in movement trajectory and velocity. T1 benefited from hybrid, active, and assistive modes due to upper extremity weakness and muscle tone. T2 benefited from hybrid and assistive modes due to impaired coordination. Healthy subjects performed isolated movements of shoulder and elbow with minimal trajectory and velocity errors. Conclusions This study demonstrates the safety and feasibility of Armstrong for upper extremity movement assistance for individuals with TBI, with therapist supervision.
Collapse
Affiliation(s)
- Zahra Kadivar
- Texas Institute for Rehabilitation and Research, Houston, TX, USA
| | | | | | - Marcia K O'Malley
- Department of Mechanical Engineering, Rice University, Houston, TX, USA
| |
Collapse
|
10
|
Active Loading Control Design for a Wearable Exoskeleton with a Bowden Cable for Transmission. ACTUATORS 2021. [DOI: 10.3390/act10060108] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Exoskeletons with a Bowden cable for power transmission have the advantages of a concentrated mass and flexible movement. However, their integrated motor is disturbed by the Bowden cable’s friction, which limits the performance of the force loading response. In this paper, we solve this problem by designing an outer-loop feedforward-feedback proportion-differentiation controller based on an inner loop disturbance observer. Firstly, the inner loop’s dynamic performance is equivalent to the designed nominal model using the proposed disturbance observer, which effectively compensates for the parameter perturbation and friction disturbance. Secondly, based on an analysis of the stability of the inner loop controller, we obtain the stability condition and discuss the influence of modeling errors on the inner loop’s dynamic performance. Thirdly, to avoid excessive noise from the force sensors being introduced into the designed disturbance observer, we propose the feedforward-feedback proportion-differentiation controller based on the nominal model and pole configuration, which improves the outer loop’s force loading performance. Experiments are conducted, which verify the effectiveness of the proposed methods.
Collapse
|
11
|
Dittli J, Hofmann UAT, Bützer T, Smit G, Lambercy O, Gassert R. Remote Actuation Systems for Fully Wearable Assistive Devices: Requirements, Selection, and Optimization for Out-of-the-Lab Application of a Hand Exoskeleton. Front Robot AI 2021; 7:596185. [PMID: 33585573 PMCID: PMC7876397 DOI: 10.3389/frobt.2020.596185] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Accepted: 11/06/2020] [Indexed: 01/26/2023] Open
Abstract
Wearable robots assist individuals with sensorimotor impairment in daily life, or support industrial workers in physically demanding tasks. In such scenarios, low mass and compact design are crucial factors for device acceptance. Remote actuation systems (RAS) have emerged as a popular approach in wearable robots to reduce perceived weight and increase usability. Different RAS have been presented in the literature to accommodate for a wide range of applications and related design requirements. The push toward use of wearable robotics in out-of-the-lab applications in clinics, home environments, or industry created a shift in requirements for RAS. In this context, high durability, ergonomics, and simple maintenance gain in importance. However, these are only rarely considered and evaluated in research publications, despite being drivers for device abandonment by end-users. In this paper, we summarize existing approaches of RAS for wearable assistive technology in a literature review and compare advantages and disadvantages, focusing on specific evaluation criteria for out-of-the-lab applications to provide guidelines for the selection of RAS. Based on the gained insights, we present the development, optimization, and evaluation of a cable-based RAS for out-of-the-lab applications in a wearable assistive soft hand exoskeleton. The presented RAS features full wearability, high durability, high efficiency, and appealing design while fulfilling ergonomic criteria such as low mass and high wearing comfort. This work aims to support the transfer of RAS for wearable robotics from controlled lab environments to out-of-the-lab applications.
Collapse
Affiliation(s)
- Jan Dittli
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Urs A. T. Hofmann
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Tobias Bützer
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Gerwin Smit
- Department of BioMechanical Engineering, Delft University of Technology, Delft, Netherlands
| | - Olivier Lambercy
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Roger Gassert
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| |
Collapse
|
12
|
Hobbs B, Artemiadis P. A Review of Robot-Assisted Lower-Limb Stroke Therapy: Unexplored Paths and Future Directions in Gait Rehabilitation. Front Neurorobot 2020; 14:19. [PMID: 32351377 PMCID: PMC7174593 DOI: 10.3389/fnbot.2020.00019] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2020] [Accepted: 03/16/2020] [Indexed: 01/28/2023] Open
Abstract
Stroke affects one out of every six people on Earth. Approximately 90% of stroke survivors have some functional disability with mobility being a major impairment, which not only affects important daily activities but also increases the likelihood of falling. Originally intended to supplement traditional post-stroke gait rehabilitation, robotic systems have gained remarkable attention in recent years as a tool to decrease the strain on physical therapists while increasing the precision and repeatability of the therapy. While some of the current methods for robot-assisted rehabilitation have had many positive and promising outcomes, there is moderate evidence of improvement in walking and motor recovery using robotic devices compared to traditional practice. In order to better understand how and where robot-assisted rehabilitation has been effective, it is imperative to identify the main schools of thought that have prevailed. This review intends to observe those perspectives through three different lenses: the goal and type of interaction, the physical implementation, and the sensorimotor pathways targeted by robotic devices. The ways that researchers approach the problem of restoring gait function are grouped together in an intuitive way. Seeing robot-assisted rehabilitation in this unique light can naturally provoke the development of new directions to potentially fill the current research gaps and eventually discover more effective ways to provide therapy. In particular, the idea of utilizing the human inter-limb coordination mechanisms is brought up as an especially promising area for rehabilitation and is extensively discussed.
Collapse
Affiliation(s)
| | - Panagiotis Artemiadis
- Human-Oriented Robotics and Control Laboratory, Department of Mechanical Engineering, University of Delaware, Newark, DE, United States
| |
Collapse
|