1
|
Vallejo-Mancero B, Faci-Lázaro S, Zapata M, Soriano J, Madrenas J. Real-time hardware emulation of neural cultures: A comparative study of in vitro, in silico and in duris silico models. Neural Netw 2024; 179:106593. [PMID: 39142177 DOI: 10.1016/j.neunet.2024.106593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 06/20/2024] [Accepted: 07/31/2024] [Indexed: 08/16/2024]
Abstract
Biological neural networks are well known for their capacity to process information with extremely low power consumption. Fields such as Artificial Intelligence, with high computational costs, are seeking for alternatives inspired in biological systems. An inspiring alternative is to implement hardware architectures that replicate the behavior of biological neurons but with the flexibility in programming capabilities of an electronic device, all combined with a relatively low operational cost. To advance in this quest, here we analyze the capacity of the HEENS hardware architecture to operate in a similar manner as an in vitro neuronal network grown in the laboratory. For that, we considered data of spontaneous activity in living neuronal cultures of about 400 neurons and compared their collective dynamics and functional behavior with those obtained from direct numerical simulations (in silico) and hardware implementations (in duris silico). The results show that HEENS is capable to mimic both the in vitro and in silico systems with high efficient-cost ratio, and on different network topological designs. Our work shows that compact low-cost hardware implementations are feasible, opening new avenues for future, highly efficient neuromorphic devices and advanced human-machine interfacing.
Collapse
Affiliation(s)
- Bernardo Vallejo-Mancero
- Department of Electronic Engineering, Universitat Politecnica de Catalunya, Jordi Girona, 1-3, edif. C4, Barcelona, 08034, Catalunya, Spain.
| | - Sergio Faci-Lázaro
- Department of Condensed Matter Physics, University of Zaragoza, C. de Pedro Cerbuna, 12, Zaragoza, 50009, Spain; GOTHAM Lab, Institute of Biocomputation and Physics of Complex Systems, University of Zaragoza, C. de Pedro Cerbuna, 12, Zaragoza, 50009, Spain
| | - Mireya Zapata
- Department of Electronic Engineering, Universitat Politecnica de Catalunya, Jordi Girona, 1-3, edif. C4, Barcelona, 08034, Catalunya, Spain; Centro de Investigación en Mecatrónica y Sistemas Interactivos - MIST, Universidad Indoamérica, Machala y Sabanilla, Quito, 170103, Ecuador
| | - Jordi Soriano
- Departament de Física de la Matèria Condensada, Universitat de Barcelona, Martíi Franquès 1, Barcelona, 08028, Spain; Universitat de Barcelona Institute of Complex Systems (UBICS), Gran Via Corts Catalanes 585, Barcelona, 08007, Spain
| | - Jordi Madrenas
- Department of Electronic Engineering, Universitat Politecnica de Catalunya, Jordi Girona, 1-3, edif. C4, Barcelona, 08034, Catalunya, Spain
| |
Collapse
|
2
|
Buthut M, Starke G, Akmazoglu TB, Colucci A, Vermehren M, van Beinum A, Bublitz C, Chandler J, Ienca M, Soekadar SR. HYBRIDMINDS-summary and outlook of the 2023 international conference on the ethics and regulation of intelligent neuroprostheses. Front Hum Neurosci 2024; 18:1489307. [PMID: 39483192 PMCID: PMC11524843 DOI: 10.3389/fnhum.2024.1489307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2024] [Accepted: 09/30/2024] [Indexed: 11/03/2024] Open
Abstract
Neurotechnology and Artificial Intelligence (AI) have developed rapidly in recent years with an increasing number of applications and AI-enabled devices that are about to enter the market. While promising to substantially improve quality of life across various severe medical conditions, there are also concerns that the convergence of these technologies, e.g., in the form of intelligent neuroprostheses, may have undesirable consequences and compromise cognitive liberty, mental integrity, or mental privacy. Therefore, various international organizations, such as the Organization for Economic Cooperation and Development (OECD) or United Nations Educational, Scientific and Cultural Organization (UNESCO), have formed initiatives to tackle such questions and develop recommendations that mitigate risks while fostering innovation. In this context, a first international conference on the ethics and regulation of intelligent neuroprostheses was held in Berlin, Germany, in autumn 2023. The conference gathered leading experts in neuroscience, engineering, ethics, law, philosophy as well as representatives of industry, policy making and the media. Here, we summarize the highlights of the conference, underline the areas in which a broad consensus was found among participants, and provide an outlook on future challenges in development, deployment, and regulation of intelligent neuroprostheses.
Collapse
Affiliation(s)
- Maria Buthut
- Clinical Neurotechnology Laboratory, Department of Psychiatry and Neurosciences at the Charité Campus Mitte, Charité – Universitätsmedizin Berlin, Berlin, Germany
- Berlin Institute of Health at Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Georg Starke
- Faculty of Medicine, Institute for History and Ethics of Medicine, Technical University of Munich, Munich, Germany
- École Polytechnique Fédérale de Lausanne, College of Humanities, Lausanne, Switzerland
| | | | - Annalisa Colucci
- Clinical Neurotechnology Laboratory, Department of Psychiatry and Neurosciences at the Charité Campus Mitte, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Mareike Vermehren
- Clinical Neurotechnology Laboratory, Department of Psychiatry and Neurosciences at the Charité Campus Mitte, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | | | | | | | - Marcello Ienca
- Faculty of Medicine, Institute for History and Ethics of Medicine, Technical University of Munich, Munich, Germany
- École Polytechnique Fédérale de Lausanne, College of Humanities, Lausanne, Switzerland
| | - Surjo R. Soekadar
- Clinical Neurotechnology Laboratory, Department of Psychiatry and Neurosciences at the Charité Campus Mitte, Charité – Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
3
|
Ail BE, Ramele R, Gambini J, Santos JM. An Intrinsically Explainable Method to Decode P300 Waveforms from EEG Signal Plots Based on Convolutional Neural Networks. Brain Sci 2024; 14:836. [PMID: 39199527 PMCID: PMC11487430 DOI: 10.3390/brainsci14080836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2024] [Revised: 08/15/2024] [Accepted: 08/16/2024] [Indexed: 09/01/2024] Open
Abstract
This work proposes an intrinsically explainable, straightforward method to decode P300 waveforms from electroencephalography (EEG) signals, overcoming the black box nature of deep learning techniques. The proposed method allows convolutional neural networks to decode information from images, an area where they have achieved astonishing performance. By plotting the EEG signal as an image, it can be both visually interpreted by physicians and technicians and detected by the network, offering a straightforward way of explaining the decision. The identification of this pattern is used to implement a P300-based speller device, which can serve as an alternative communication channel for persons affected by amyotrophic lateral sclerosis (ALS). This method is validated by identifying this signal by performing a brain-computer interface simulation on a public dataset from ALS patients. Letter identification rates from the speller on the dataset show that this method can identify the P300 signature on the set of 8 patients. The proposed approach achieves similar performance to other state-of-the-art proposals while providing clinically relevant explainability (XAI).
Collapse
Affiliation(s)
- Brian Ezequiel Ail
- Instituto Tecnológico de Buenos Aires (ITBA), Buenos Aires C1437, Argentina;
| | - Rodrigo Ramele
- Instituto Tecnológico de Buenos Aires (ITBA), Buenos Aires C1437, Argentina;
| | - Juliana Gambini
- Centro de Investigación en Informática Aplicada (CIDIA), Universidad Nacional de Hurlingham (UNAHUR), Hurlingham B1688, Argentina; (J.G.); (J.M.S.)
- CPSI—Universidad Tecnológica Nacional, FRBA, Buenos Aires C1041, Argentina
| | - Juan Miguel Santos
- Centro de Investigación en Informática Aplicada (CIDIA), Universidad Nacional de Hurlingham (UNAHUR), Hurlingham B1688, Argentina; (J.G.); (J.M.S.)
| |
Collapse
|
4
|
van Stuijvenberg OC, Broekman MLD, Wolff SEC, Bredenoord AL, Jongsma KR. Developer perspectives on the ethics of AI-driven neural implants: a qualitative study. Sci Rep 2024; 14:7880. [PMID: 38570593 PMCID: PMC10991497 DOI: 10.1038/s41598-024-58535-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 04/01/2024] [Indexed: 04/05/2024] Open
Abstract
Convergence of neural implants with artificial intelligence (AI) presents opportunities for the development of novel neural implants and improvement of existing neurotechnologies. While such technological innovation carries great promise for the restoration of neurological functions, they also raise ethical challenges. Developers of AI-driven neural implants possess valuable knowledge on the possibilities, limitations and challenges raised by these innovations; yet their perspectives are underrepresented in academic literature. This study aims to explore perspectives of developers of neurotechnology to outline ethical implications of three AI-driven neural implants: a cochlear implant, a visual neural implant, and a motor intention decoding speech-brain-computer-interface. We conducted semi-structured focus groups with developers (n = 19) of AI-driven neural implants. Respondents shared ethically relevant considerations about AI-driven neural implants that we clustered into three themes: (1) design aspects; (2) challenges in clinical trials; (3) impact on users and society. Developers considered accuracy and reliability of AI-driven neural implants conditional for users' safety, authenticity, and mental privacy. These needs were magnified by the convergence with AI. Yet, the need for accuracy and reliability may also conflict with potential benefits of AI in terms of efficiency and complex data interpretation. We discuss strategies to mitigate these challenges.
Collapse
Affiliation(s)
- Odile C van Stuijvenberg
- Department of Bioethics and Health Humanities, Julius Center, University Medical Center Utrecht, Utrecht University, 3508 GA, Utrecht, The Netherlands.
| | - Marike L D Broekman
- Department of Neurosurgery, Haaglanden Medical Center, 2512 VA, The Hague, The Netherlands
- Department of Neurosurgery, Leiden University Medical Center, 2333 ZA, Leiden, The Netherlands
| | - Samantha E C Wolff
- Netherlands Institute for Neuroscience, 1105 BA, Amsterdam, The Netherlands
| | - Annelien L Bredenoord
- Erasmus School of Philosophy, Erasmus University Rotterdam, 3062 PA, Rotterdam, The Netherlands
| | - Karin R Jongsma
- Department of Bioethics and Health Humanities, Julius Center, University Medical Center Utrecht, Utrecht University, 3508 GA, Utrecht, The Netherlands
| |
Collapse
|
5
|
González-González MA, Conde SV, Latorre R, Thébault SC, Pratelli M, Spitzer NC, Verkhratsky A, Tremblay MÈ, Akcora CG, Hernández-Reynoso AG, Ecker M, Coates J, Vincent KL, Ma B. Bioelectronic Medicine: a multidisciplinary roadmap from biophysics to precision therapies. Front Integr Neurosci 2024; 18:1321872. [PMID: 38440417 PMCID: PMC10911101 DOI: 10.3389/fnint.2024.1321872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 01/10/2024] [Indexed: 03/06/2024] Open
Abstract
Bioelectronic Medicine stands as an emerging field that rapidly evolves and offers distinctive clinical benefits, alongside unique challenges. It consists of the modulation of the nervous system by precise delivery of electrical current for the treatment of clinical conditions, such as post-stroke movement recovery or drug-resistant disorders. The unquestionable clinical impact of Bioelectronic Medicine is underscored by the successful translation to humans in the last decades, and the long list of preclinical studies. Given the emergency of accelerating the progress in new neuromodulation treatments (i.e., drug-resistant hypertension, autoimmune and degenerative diseases), collaboration between multiple fields is imperative. This work intends to foster multidisciplinary work and bring together different fields to provide the fundamental basis underlying Bioelectronic Medicine. In this review we will go from the biophysics of the cell membrane, which we consider the inner core of neuromodulation, to patient care. We will discuss the recently discovered mechanism of neurotransmission switching and how it will impact neuromodulation design, and we will provide an update on neuronal and glial basis in health and disease. The advances in biomedical technology have facilitated the collection of large amounts of data, thereby introducing new challenges in data analysis. We will discuss the current approaches and challenges in high throughput data analysis, encompassing big data, networks, artificial intelligence, and internet of things. Emphasis will be placed on understanding the electrochemical properties of neural interfaces, along with the integration of biocompatible and reliable materials and compliance with biomedical regulations for translational applications. Preclinical validation is foundational to the translational process, and we will discuss the critical aspects of such animal studies. Finally, we will focus on the patient point-of-care and challenges in neuromodulation as the ultimate goal of bioelectronic medicine. This review is a call to scientists from different fields to work together with a common endeavor: accelerate the decoding and modulation of the nervous system in a new era of therapeutic possibilities.
Collapse
Affiliation(s)
- María Alejandra González-González
- Jan and Dan Duncan Neurological Research Institute, Texas Children’s Hospital, Houston, TX, United States
- Department of Pediatric Neurology, Baylor College of Medicine, Houston, TX, United States
| | - Silvia V. Conde
- iNOVA4Health, NOVA Medical School, Faculdade de Ciências Médicas, NOVA University, Lisbon, Portugal
| | - Ramon Latorre
- Centro Interdisciplinario de Neurociencia de Valparaíso, Facultad de Ciencias, Universidad de Valparaíso, Valparaíso, Chile
| | - Stéphanie C. Thébault
- Laboratorio de Investigación Traslacional en salud visual (D-13), Instituto de Neurobiología, Universidad Nacional Autónoma de México (UNAM), Querétaro, Mexico
| | - Marta Pratelli
- Neurobiology Department, Kavli Institute for Brain and Mind, UC San Diego, La Jolla, CA, United States
| | - Nicholas C. Spitzer
- Neurobiology Department, Kavli Institute for Brain and Mind, UC San Diego, La Jolla, CA, United States
| | - Alexei Verkhratsky
- Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
- Achucarro Centre for Neuroscience, IKERBASQUE, Basque Foundation for Science, Bilbao, Spain
- Department of Forensic Analytical Toxicology, School of Forensic Medicine, China Medical University, Shenyang, China
- International Collaborative Center on Big Science Plan for Purinergic Signaling, Chengdu University of Traditional Chinese Medicine, Chengdu, China
- Department of Stem Cell Biology, State Research Institute Centre for Innovative Medicine, Vilnius, Lithuania
| | - Marie-Ève Tremblay
- Division of Medical Sciences, University of Victoria, Victoria, BC, Canada
- Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada
- Department of Molecular Medicine, Université Laval, Québec City, QC, Canada
- Department of Biochemistry and Molecular Biology, The University of British Columbia, Vancouver, BC, Canada
| | - Cuneyt G. Akcora
- Department of Computer Science, University of Central Florida, Orlando, FL, United States
| | | | - Melanie Ecker
- Department of Biomedical Engineering, University of North Texas, Denton, TX, United States
| | | | - Kathleen L. Vincent
- Department of Obstetrics and Gynecology, University of Texas Medical Branch, Galveston, TX, United States
| | - Brandy Ma
- Stanley H. Appel Department of Neurology, Houston Methodist Hospital, Houston, TX, United States
| |
Collapse
|
6
|
Rodilla BL, Arché-Núñez A, Ruiz-Gómez S, Domínguez-Bajo A, Fernández-González C, Guillén-Colomer C, González-Mayorga A, Rodríguez-Díez N, Camarero J, Miranda R, López-Dolado E, Ocón P, Serrano MC, Pérez L, González MT. Flexible metallic core-shell nanostructured electrodes for neural interfacing. Sci Rep 2024; 14:3729. [PMID: 38355737 PMCID: PMC10866994 DOI: 10.1038/s41598-024-53719-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 02/04/2024] [Indexed: 02/16/2024] Open
Abstract
Electrodes with nanostructured surface have emerged as promising low-impedance neural interfaces that can avoid the charge-injection restrictions typically associated to microelectrodes. In this work, we propose a novel approximation, based on a two-step template assisted electrodeposition technique, to obtain flexible nanostructured electrodes coated with core-shell Ni-Au vertical nanowires. These nanowires benefit from biocompatibility of the Au shell exposed to the environment and the mechanical properties of Ni that allow for nanowires longer and more homogeneous in length than their only-Au counterparts. The nanostructured electrodes show impedance values, measured by electrochemical impedance spectroscopy (EIS), at least 9 times lower than those of flat reference electrodes. This ratio is in good accordance with the increased effective surface area determined both from SEM images and cyclic voltammetry measurements, evidencing that only Au is exposed to the medium. The observed EIS profile evolution of Ni-Au electrodes over 7 days were very close to those of Au electrodes and differently from Ni ones. Finally, the morphology, viability and neuronal differentiation of rat embryonic cortical cells cultured on Ni-Au NW electrodes were found to be similar to those on control (glass) substrates and Au NW electrodes, accompanied by a lower glial cell differentiation. This positive in-vitro neural cell behavior encourages further investigation to explore the tissue responses that the implantation of these nanostructured electrodes might elicit in healthy (damaged) neural tissues in vivo, with special emphasis on eventual tissue encapsulation.
Collapse
Affiliation(s)
- Beatriz L Rodilla
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Departamento de Física de Materiales, Universidad Complutense de Madrid, Plaza de las Ciencias S/N, 28040, Madrid, Spain
| | - Ana Arché-Núñez
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
| | - Sandra Ruiz-Gómez
- Max Planck Institute for Chemical Physics of Solids, Dresden, Germany
| | - Ana Domínguez-Bajo
- Instituto de Ciencia de Materiales de Madrid (ICMM), CSIC, Calle Sor Juana Inés de la Cruz 3, 28049, Madrid, Spain
- Animal Molecular and Cellular Biology group (AMCB), Louvain Institute of Biomolecular Science and Technology (LIBST), Université catholique de Louvain, Place Croix du Sud 5, 1348 , Louvain la Neuve, Belgium
| | | | | | | | | | - Julio Camarero
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Department de Física de la Materia Condensada and Instituto "Nicolás Cabrera", Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Rodolfo Miranda
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Department de Física de la Materia Condensada and Instituto "Nicolás Cabrera", Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Elisa López-Dolado
- Hospital Nacional de Parapléjicos, SESCAM, Finca la Peraleda S/N, 45071, Toledo, Spain
- Design and development of Biomaterials for Neural Regeneration, HNP-SESCAM, Associated Unit With CSIC Through ICMM, Finca La Peraleda S/N, 45071, Toledo, Spain
| | - Pilar Ocón
- Departamento de Química Física Aplicada, Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - María C Serrano
- Instituto de Ciencia de Materiales de Madrid (ICMM), CSIC, Calle Sor Juana Inés de la Cruz 3, 28049, Madrid, Spain
| | - Lucas Pérez
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Departamento de Física de Materiales, Universidad Complutense de Madrid, Plaza de las Ciencias S/N, 28040, Madrid, Spain
| | | |
Collapse
|