1
|
Soto E, Pliego A, Vega R. Vestibular prosthesis: from basic research to clinics. Front Integr Neurosci 2023; 17:1161860. [PMID: 37265514 PMCID: PMC10230114 DOI: 10.3389/fnint.2023.1161860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 04/26/2023] [Indexed: 06/03/2023] Open
Abstract
Balance disorders are highly prevalent worldwide, causing substantial disability with high personal and socioeconomic impact. The prognosis in many of these patients is poor, and rehabilitation programs provide little help in many cases. This medical problem can be addressed using microelectronics by combining the highly successful cochlear implant experience to produce a vestibular prosthesis, using the technical advances in micro gyroscopes and micro accelerometers, which are the electronic equivalents of the semicircular canals (SCC) and the otolithic organs. Reaching this technological milestone fostered the possibility of using these electronic devices to substitute the vestibular function, mainly for visual stability and posture, in case of damage to the vestibular endorgans. The development of implantable and non-implantable devices showed diverse outcomes when considering the integrity of the vestibular pathways, the device parameters (current intensity, impedance, and waveform), and the targeted physiological function (balance and gaze). In this review, we will examine the development and testing of various prototypes of the vestibular implant (VI). The insight raised by examining the state-of-the-art vestibular prosthesis will facilitate the development of new device-development strategies and discuss the feasibility of complex combinations of implantable devices for disorders that directly affect balance and motor performance.
Collapse
Affiliation(s)
- Enrique Soto
- Benemérita Universidad Autónoma de Puebla, Instituto de Fisiología, Puebla, Mexico
| | - Adriana Pliego
- Benemérita Universidad Autónoma de Puebla, Instituto de Fisiología, Puebla, Mexico
- Universidad Autónoma del Estado de México (UAEMéx), Facultad de Medicina, Toluca, Mexico
| | - Rosario Vega
- Benemérita Universidad Autónoma de Puebla, Instituto de Fisiología, Puebla, Mexico
| |
Collapse
|
2
|
Truong DQ, Guillen A, Nooristani M, Maheu M, Champoux F, Datta A. Impact of galvanic vestibular stimulation electrode current density on brain current flow patterns: Does electrode size matter? PLoS One 2023; 18:e0273883. [PMID: 36735686 PMCID: PMC9897567 DOI: 10.1371/journal.pone.0273883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 01/10/2023] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Galvanic vestibular stimulation (GVS) uses at least one electrode placed on the mastoid process with one or multiple placed over other head areas to stimulate the vestibular system. The exact electrode size used is not given much importance in the literature and has not been reported in several studies. In a previous study, we compared the clinical effects of using different electrode sizes (3 cm2 and 35 cm2) with placebo but with the same injected current, on postural control. We observed significant improvement using the smaller size electrode but not with the bigger size electrode. The goal of this study was to simulate the current flow patterns with the intent to shed light and potentially explain the experimental outcome. METHODS We used an ultra-high-resolution structural dataset and developed a model to simulate the application of different electrode sizes. We considered current flow in the brain and in the vestibular labyrinth. RESULTS Our simulation results verified the focality increase using smaller electrodes that we postulated as the main reason for our clinical effect. The use of smaller size electrodes in combination with the montage employed also result in higher induced electric field (E-field) in the brain. CONCLUSIONS Electrode size and related current density is a critical parameter to characterize any GVS administration as the choice impacts the induced E-field. It is evident that the higher induced E-field likely contributed to the clinical outcome reported in our prior study.
Collapse
Affiliation(s)
- Dennis Q. Truong
- Research and Development, Soterix Medical, Woodbridge, NJ, United States of America
- * E-mail:
| | - Alexander Guillen
- Research and Development, Soterix Medical, Woodbridge, NJ, United States of America
| | - Mujda Nooristani
- Faculty of Medicine, School of Speech-Language and Audiology, University of Montreal, Montreal, QC, Canada
- Institut Universitaire sur la Réadaptation en Déficience Physique de Montréal (IURDPM), Pavillon Laurier, CIUSSS du Centre-Sud-de-L’Île-de-Montréal, Montréal, QC, Canada
- Centre de Recherche de l’Institut Universitaire de Gériatrie de Montréal, Montréal, Québec, Canada
| | - Maxime Maheu
- Faculty of Medicine, School of Speech-Language and Audiology, University of Montreal, Montreal, QC, Canada
- Institut Universitaire sur la Réadaptation en Déficience Physique de Montréal (IURDPM), Pavillon Laurier, CIUSSS du Centre-Sud-de-L’Île-de-Montréal, Montréal, QC, Canada
| | - Francois Champoux
- Faculty of Medicine, School of Speech-Language and Audiology, University of Montreal, Montreal, QC, Canada
- Institut Universitaire sur la Réadaptation en Déficience Physique de Montréal (IURDPM), Pavillon Laurier, CIUSSS du Centre-Sud-de-L’Île-de-Montréal, Montréal, QC, Canada
- Centre de Recherche de l’Institut Universitaire de Gériatrie de Montréal, Montréal, Québec, Canada
| | - Abhishek Datta
- Research and Development, Soterix Medical, Woodbridge, NJ, United States of America
- City College of New York, New York, NY, United States of America
| |
Collapse
|
3
|
D’Alessandro S, Handler M, Saba R, Garnham C, Baumgarten D. Computer Simulation of the Electrical Stimulation of the Human Vestibular System: Effects of the Reactive Component of Impedance on Voltage Waveform and Nerve Selectivity. J Assoc Res Otolaryngol 2022; 23:815-833. [PMID: 36050508 PMCID: PMC9789245 DOI: 10.1007/s10162-022-00868-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 08/13/2022] [Indexed: 01/06/2023] Open
Abstract
The vestibular system is responsible for our sense of balance and spatial orientation. Recent studies have shown the possibility of partially restoring the function of this system using vestibular implants. Electrical modeling is a valuable tool in assisting the development of these implants by analyzing stimulation effects. However, previous modeling approaches of the vestibular system assumed quasi-static conditions. In this work, an extended modeling approach is presented that considers the reactive component of impedance and the electrode-tissue interface and their effects are investigated in a 3D human vestibular computer model. The Fourier finite element method was employed considering the frequency-dependent electrical properties of the different tissues. The electrode-tissue interface was integrated by an instrumental electrode model. A neuron model of myelinated fibers was employed to predict the nerve responses to the electrical stimulus. Morphological changes of the predicted voltage waveforms considering the dielectric tissue properties were found compared to quasi-static simulations, particularly during monopolar electrode configuration. Introducing the polarization capacitance and the scar tissue around the electrode in combination with a power limitation leads to a considerable current reduction applied through the active electrode and, consequently, to reduced voltage amplitudes of the stimulus waveforms. The reactive component of impedance resulted in better selectivity for the excitation of target nerves compared to the quasi-static simulation at the expense of slightly increased stimulus current amplitudes. We conclude that tissue permittivity and effects of the electrode-tissue interface should be considered to improve the accuracy of the simulations.
Collapse
Affiliation(s)
- Simone D’Alessandro
- Institute of Electrical and Biomedical Engineering, UMIT - Private University for Health Sciences, Medical Informatics and Technology, Hall in Tirol, Austria
| | - Michael Handler
- Institute of Electrical and Biomedical Engineering, UMIT - Private University for Health Sciences, Medical Informatics and Technology, Hall in Tirol, Austria
| | | | | | - Daniel Baumgarten
- Institute of Electrical and Biomedical Engineering, UMIT - Private University for Health Sciences, Medical Informatics and Technology, Hall in Tirol, Austria
| |
Collapse
|
4
|
Liang J, Ke Z, Welch PV, Gan RZ, Dai C. A comprehensive finite element model for studying Cochlear-Vestibular interaction. Comput Methods Biomech Biomed Engin 2021; 25:204-214. [PMID: 34641759 DOI: 10.1080/10255842.2021.1946522] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
We present a 3-D finite element (FE) model of the chinchilla's inner ear consisting of the entire cochlea structure and the vestibular system. The reaction of the basilar membrane to the head rotation and the reaction of ampulla to the stapes movement were investigated. These results demonstrate the existence of hearing-vestibular system interaction. They provide an explanation to the clinical finding on the coexistence between hearing loss and equilibration dysfunction. It is a preliminary, yet critical step toward the development of a comprehensive FE model of an entire ear for mechano-acoustic analysis.
Collapse
Affiliation(s)
- Junfeng Liang
- Aerospace & Mechanical Engineering, University of Oklahoma, Norman, OK, USA
| | - Zhang Ke
- Aerospace & Mechanical Engineering, University of Oklahoma, Norman, OK, USA
| | - Paige V Welch
- Aerospace & Mechanical Engineering, University of Oklahoma, Norman, OK, USA
| | - Rong Z Gan
- Aerospace & Mechanical Engineering, University of Oklahoma, Norman, OK, USA
| | - Chenkai Dai
- Aerospace & Mechanical Engineering, University of Oklahoma, Norman, OK, USA
| |
Collapse
|
5
|
Stefano M, Cordella F, Loppini A, Filippi S, Zollo L. A Multiscale Approach to Axon and Nerve Stimulation Modeling: A Review. IEEE Trans Neural Syst Rehabil Eng 2021; 29:397-407. [PMID: 33497336 DOI: 10.1109/tnsre.2021.3054551] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Electrical nerve fiber stimulation is a technique widely used in prosthetics and rehabilitation, and its study from a computational point of view can be a useful instrument to support experimental tests. In the last years, there was an increasing interest in computational modeling of neural cells and numerical simulations on nerve fibers stimulation because of its usefulness in forecasting the effect of electrical current stimuli delivered to tissues through implanted electrodes, in the design of optimal stimulus waveforms based on the specific application (i.e., inducing limb movements, sensory feedback or physiological function restoring), and in the evaluation of the current stimuli properties according to the characteristics of the nerves surrounding tissue. Therefore, a review study on the main modeling and computational frameworks adopted to investigate peripheral nerve stimulation is an important instrument to support and drive future research works. To this aim, this paper deals with mathematical models of neural cells with a detailed description of ion channels and numerical simulations using finite element methods to describe the dynamics of electrical stimulation by implanted electrodes in peripheral nerve fibers. In particular, we evaluate different nerve cell models considering different ion channels present in neurons and provide a guideline on multiscale numerical simulations of electrical nerve fibers stimulation.
Collapse
|
6
|
Shi P, Du J, Fang F, Yu H, Liu J. Design and Implementation of an Intelligent Analgesic Bracelet Based on Wrist-ankle Acupuncture. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; 14:1431-1440. [PMID: 33206609 DOI: 10.1109/tbcas.2020.3039063] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A flexible, multifunctional, and intelligent analgesic bracelet was proposed in this article to alleviate symptoms of pain. Based on the theory of wrist-ankle acupuncture in traditional Chinese medicine, transcutaneous electrical nerve stimulation is the technical basis of the method. A set of targeted circuit system capable of generating adjustable electrical stimulation signals to simulate filamentary acupuncture was designed. The system architecture includes a wireless communication module, a signal control module, a stimulus signal generation module, and a wearable, flexible bracelet. In addition, a pain assessment interface with a visual analog scale was designed to assess pain levels. Two comparative experiments were designed, involving a custom pain assessment scale and hand-held dolorimeter that were performed before and after wearing the bracelet to verify the analgesic effect of the bracelet. The results showed that the wrist-worn analgesic bracelet is significantly effective in alleviating pain in various parts of the human body.
Collapse
|
7
|
Steinhardt CR, Fridman GY. Predicting Response of Spontaneously Firing Afferents to Prosthetic Pulsatile Stimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2929-2933. [PMID: 33018620 DOI: 10.1109/embc44109.2020.9175282] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Pulsatile electrical stimulation is used in neural prostheses such as the vestibular prosthesis. In a healthy vestibular system, head motion is encoded by changes in the firing rates of afferents around their spontaneous baseline rate. For people suffering from bilateral vestibular disorder (BVD), head motion no longer modulates firing rate. Vestibular prostheses use a gyroscope to detect head motion and stimulate neurons directly in a way that mimics natural modulation. Proper restoration of vestibular function relies on the ability of stimulation to evoke the same firing patterns as the healthy system. For this reason, it is necessary to understand what firing rates are produced for different stimulation parameters. Two stimulation parameters commonly controlled in pulsatile neuromodulation are pulse rate and pulse amplitude. Previous neural recording experiments in the vestibular nerve contradict widely held assumptions about the relationship between pulse rates and evoked spike activity, and the relationship between pulse amplitude and neural activity has not been explored. Here we use a well-established computational model of the vestibular afferent to simulate responses to different pulse rates and amplitudes. We confirm that our simulated neural results agree with the existing experimental data. Finally, we developed the "Action Potential Collision" (APC) equation that defines induced firing as a function of spontaneous firing rate, pulse rate, and pulse amplitude. We show that this relationship can successfully predict simulated vestibular activity by accounting for interactions between pulses and spontaneous firing.
Collapse
|
8
|
Thomas C, Truong D, Clark TK, Datta A. Understanding current flow in Galvanic Vestibular Stimulation: A Computational Study. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2442-2446. [PMID: 33018500 DOI: 10.1109/embc44109.2020.9176716] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Galvanic vestibular stimulation (GVS) involves the application of electrical current through electrodes placed exclusively at the mastoids or in combination with electrodes placed on other regions. It is a simple, safe modality to modulate and probe vestibular function. Despite a long history of use, it continues to be primarily used as a research tool with no fully developed therapeutic use. This is partly due to the fact that to further advance this technique, a better understanding of what structures are stimulated and by how much is needed. While models have been proposed to explain response, cellular and structural substrates confirmed empirically, the exact current flow pattern has not been investigated.The goal of this study is to therefore determine current flow patterns in GVS. In order to do so, we developed the first ultrahigh-resolution finite element model of GVS incorporating the tiny structures of interest in the inner ear. We simulated the Bilateral-Bipolar, Bilateral-Monopolar, and the Unilateral-Monopolar configurations. Specifically, we generated surface electric field magnitude plots for the brain and for structures considered most relevant to GVS mechanism of action- the semi-circular canals (SCC) and the otolith.Findings show that the Bilateral-Bipolar configuration results in the most spatially restricted flow while the Unilateral-Monopolar configuration results in the most diffuse. With respect to SCC and the otolith, both Bilateral-Bipolar and Bilateral-Monopolar configurations led to similar flow in both the left and right pairs. For the Unilateral-Monopolar configuration, we observed increased flow in the left pair.We expect via this first model developed for GVS, researchers investigating this technique to have a better understanding of the effects of different configurations. Anatomically detailed models like these may also help understand the mechanism of action and may guide the rational design of future GVS administration.
Collapse
|
9
|
A Lead Field Two-Domain Model for Longitudinal Neural Tracts-Analytical Framework and Implications for Signal Bandwidth. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2020; 2020:5436807. [PMID: 32565881 PMCID: PMC7275970 DOI: 10.1155/2020/5436807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Revised: 04/07/2020] [Accepted: 04/21/2020] [Indexed: 11/18/2022]
Abstract
Somatosensory evoked potentials are a well-established tool for assessing volley conduction in afferent neural pathways. However, from a clinical perspective, recording of spinal signals is still a demanding task due to the low amplitudes compared to relevant noise sources. Computer modeling is a powerful tool for gaining insight into signal genesis and, thus, for promoting future innovations in signal extraction. However, due to the complex structure of neural pathways, modeling is computationally demanding. We present a theoretical framework which allows computing the electric potential generated by a single axon in a body surface lead by the convolution of the neural lead field function with a propagating action potential term. The signal generated by a large cohort of axons was obtained by convoluting a single axonal signal with the statistical distribution of temporal dispersion of individual axonal signals. For establishing the framework, analysis was based on an analytical model. Our approach was further adopted for a numerical computation of body surface neuropotentials employing the lead field theory. Double convolution allowed straightforward analysis in the frequency domain. The highest frequency components occurred at the cellular membrane. A bandpass type spectral shape and a peak frequency of 1800 Hz was observed. The volume conductor transmitting the signal to the recording lead acted as an additional bandpass reducing the axonal peak frequency from 200 Hz to 500 Hz. The superposition of temporally dispersed axonal signals acted as an additional low-pass filter further reducing the compound action potential peak frequency from 90 Hz to 170 Hz. Our results suggest that the bandwidth of spinal evoked potentials might be narrower than the bandwidth requested by current clinical guidelines. The present findings will allow the optimization of noise suppression. Furthermore, our theoretical framework allows the adaptation in numerical methods and application in anatomically realistic geometries in future studies.
Collapse
|
10
|
Kim G, Lee S, Kim KS. Dominant parameter of galvanic vestibular stimulation for the non-associative learning processes. Med Biol Eng Comput 2020; 58:701-708. [PMID: 31953797 DOI: 10.1007/s11517-019-02117-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Accepted: 12/28/2019] [Indexed: 12/22/2022]
Abstract
Electrical stimulus is one of the common stimulating methods, and Galvanic vestibular stimulation (GVS) is the oldest form as an electrical stimulation. Nevertheless, GVS is still considered as a secondary stimulating tool for the medical purposes. Even though some unarguable findings have made using GVS, its use has been limited because of its ambiguity as an input source. For better understanding, many previous studies mainly focused on its functional effects, like the ocular reflexes. However, its fundamental effects on the neural activities are still elusive, such as the dominant influences by different parameters of GVS. Here we compared the effects on the neuronal responses by applying two different parameters, strength and rate, of GVS. To assess the dominance on the neuronal responses to these parameters, we designed three independent stimuli. Those stimuli were multiply applied to obtain the responding slopes based on the mechanism of non-associative learning processes, and the effects on the neurons were calculated as an inner angle between two responding slopes. Out of 23 neurons, 15 (65.2%) units were affected more by the strength with a statistical significance (p = 0.047). The ranges of the inner angles also implied the strength (- 3.354°~2.063°) mainly modulated by the neuronal responses comparing with those by the rate (- 2.001°~1.975°). The dominance of the parameters was closely related with the neuronal sensitivity to stimulation (SE) (p = 0.018), while there were few relations with the neuronal regularity, directional preference (DP), and the physiological response (PR) (p > 0.059). Thus, the neural information related with the dominance was delivered by the irregular neurons, and these types of neurons should be the targets for the stimulation. Graphical abstract.
Collapse
Affiliation(s)
- Gyutae Kim
- Research Institute for Aerospace Medicine, Inha University, High-Tech center #303, 100 Inharo, Namgu, InCheon, 402-751, South Korea.
- Institute for Information and Electronics Research, Inha University, High-Tech center #716, 100 Inharo, Namgu, InCheon, 402-751, South Korea.
| | - Sangmin Lee
- Institute for Information and Electronics Research, Inha University, High-Tech center #716, 100 Inharo, Namgu, InCheon, 402-751, South Korea
- Department of Electronic Engineering, Inha University, High-Tech center #704, 100 Inharo, Namgu, InCheon, 402-751, South Korea
| | - Kyu-Sung Kim
- Research Institute for Aerospace Medicine, Inha University, High-Tech center #303, 100 Inharo, Namgu, InCheon, 402-751, South Korea
- Department of Otolaryngology Head & Neck Surg., Inha University Hospital, 27 Inhang-ro, Jung-Gu, Incheon, 400-711, South Korea
| |
Collapse
|
11
|
Curthoys IS. Concepts and Physiological Aspects of the Otolith Organ in Relation to Electrical Stimulation. Audiol Neurootol 2019; 25:25-34. [PMID: 31553977 DOI: 10.1159/000502712] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Accepted: 08/13/2019] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND This paper discusses some of the concepts and major physiological issues in developing a means of electrically stimulating the otolithic system, with the final goal being the electrical stimulation of the otoliths in human patients. It contrasts the challenges of electrical stimulation of the otolith organs as compared to stimulation of the semicircular canals. Electrical stimulation may consist of trains of short-duration pulses (e.g., 0.1 ms duration at 400 Hz) by selective electrodes on otolith maculae or otolithic afferents, or unselective maintained DC stimulation by large surface electrodes on the mastoids - surface galvanic stimulation. SUMMARY Recent anatomical and physiological results are summarized in order to introduce some of the unique issues in electrical stimulation of the otoliths. The first challenge is that each otolithic macula contains receptors with opposite polarization (opposing preferred directions of stimulation), unlike the uniform polarization of receptors in each semicircular canal crista. The puzzle is that in response to the one linear acceleration in the one macula, some otolithic afferents have an increased activation whereas others have decreased activation. Key Messages: At the vestibular nucleus this opposite receptor hair cell polarization and consequent opposite afferent input allow enhanced response to the one linear acceleration, via a "push-pull" neural mechanism in a manner analogous to the enhancement of semicircular canal responses to angular acceleration. Within each otolithic macula there is not just one uniform otolithic neural input to the brain - there are very distinctly different channels of otolithic neural inputs transferring the neural data to the brainstem. As a simplification these channels are characterized as the sustained and transient systems. Afferents in each system have different responses to stimulus onset and maintained stimulation and likely different projections, and most importantly different thresholds for activation by electrical stimulation and different adaptation rates to maintained stimulation. The implications of these differences are considered.
Collapse
Affiliation(s)
- Ian S Curthoys
- Vestibular Research Laboratory, School of Psychology, University of Sydney, Sydney, New South Wales, Australia,
| |
Collapse
|