1
|
Mondini V, Sburlea AI, Müller-Putz GR. Towards unlocking motor control in spinal cord injured by applying an online EEG-based framework to decode motor intention, trajectory and error processing. Sci Rep 2024; 14:4714. [PMID: 38413782 PMCID: PMC10899181 DOI: 10.1038/s41598-024-55413-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 02/23/2024] [Indexed: 02/29/2024] Open
Abstract
Brain-computer interfaces (BCIs) can translate brain signals directly into commands for external devices. Electroencephalography (EEG)-based BCIs mostly rely on the classification of discrete mental states, leading to unintuitive control. The ERC-funded project "Feel Your Reach" aimed to establish a novel framework based on continuous decoding of hand/arm movement intention, for a more natural and intuitive control. Over the years, we investigated various aspects of natural control, however, the individual components had not yet been integrated. Here, we present a first implementation of the framework in a comprehensive online study, combining (i) goal-directed movement intention, (ii) trajectory decoding, and (iii) error processing in a unique closed-loop control paradigm. Testing involved twelve able-bodied volunteers, performing attempted movements, and one spinal cord injured (SCI) participant. Similar movement-related cortical potentials and error potentials to previous studies were revealed, and the attempted movement trajectories were overall reconstructed. Source analysis confirmed the involvement of sensorimotor and posterior parietal areas for goal-directed movement intention and trajectory decoding. The increased experiment complexity and duration led to a decreased performance than each single BCI. Nevertheless, the study contributes to understanding natural motor control, providing insights for more intuitive strategies for individuals with motor impairments.
Collapse
Affiliation(s)
- Valeria Mondini
- Institute of Neural Engineering, Graz University of Technology, Graz, Austria
| | - Andreea-Ioana Sburlea
- Bernoulli Institute for Mathematics, Computer Science and Artificial Intelligence, University of Groningen, Groningen, The Netherlands
| | - Gernot R Müller-Putz
- Institute of Neural Engineering, Graz University of Technology, Graz, Austria.
- BioTechMed, Graz, Austria.
| |
Collapse
|
2
|
Vieira JC, Guedes LA, Santos MR, Sanchez-Gendriz I. Using Explainable Artificial Intelligence to Obtain Efficient Seizure-Detection Models Based on Electroencephalography Signals. SENSORS (BASEL, SWITZERLAND) 2023; 23:9871. [PMID: 38139715 PMCID: PMC10747117 DOI: 10.3390/s23249871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 11/09/2023] [Accepted: 11/09/2023] [Indexed: 12/24/2023]
Abstract
Epilepsy is a condition that affects 50 million individuals globally, significantly impacting their quality of life. Epileptic seizures, a transient occurrence, are characterized by a spectrum of manifestations, including alterations in motor function and consciousness. These events impose restrictions on the daily lives of those affected, frequently resulting in social isolation and psychological distress. In response, numerous efforts have been directed towards the detection and prevention of epileptic seizures through EEG signal analysis, employing machine learning and deep learning methodologies. This study presents a methodology that reduces the number of features and channels required by simpler classifiers, leveraging Explainable Artificial Intelligence (XAI) for the detection of epileptic seizures. The proposed approach achieves performance metrics exceeding 95% in accuracy, precision, recall, and F1-score by utilizing merely six features and five channels in a temporal domain analysis, with a time window of 1 s. The model demonstrates robust generalization across the patient cohort included in the database, suggesting that feature reduction in simpler models-without resorting to deep learning-is adequate for seizure detection. The research underscores the potential for substantial reductions in the number of attributes and channels, advocating for the training of models with strategically selected electrodes, and thereby supporting the development of effective mobile applications for epileptic seizure detection.
Collapse
Affiliation(s)
- Jusciaane Chacon Vieira
- Department of Computer Engineering and Automation—DCA, Federal University of Rio Grande do Norte—UFRN, Natal 59078-900, RN, Brazil; (L.A.G.); (M.R.S.); (I.S.-G.)
| | | | | | | |
Collapse
|
3
|
Autonomous grasping of 3-D objects by a vision-actuated robot arm using Brain–Computer Interface. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2023.104765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2023]
|
4
|
Wang W, Shi B, Wang D, Wang J, Liu G. Enhanced lower-limb motor imagery by kinesthetic illusion. Front Neurosci 2023; 17:1077479. [PMID: 37409102 PMCID: PMC10319417 DOI: 10.3389/fnins.2023.1077479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Accepted: 05/30/2023] [Indexed: 07/07/2023] Open
Abstract
Brain-computer interface (BCI) based on lower-limb motor imagery (LMI) enables hemiplegic patients to stand and walk independently. However, LMI ability is usually poor for BCI-illiterate (e.g., some stroke patients), limiting BCI performance. This study proposed a novel LMI-BCI paradigm with kinesthetic illusion(KI) induced by vibratory stimulation on Achilles tendon to enhance LMI ability. Sixteen healthy subjects were recruited to carry out two research contents: (1) To verify the feasibility of induced KI by vibrating Achilles tendon and analyze the EEG features produced by KI, research 1 compared the subjective feeling and brain activity of participants during rest task with and without vibratory stimulation (V-rest, rest). (2) Research 2 compared the LMI-BCI performance with and without KI (KI-LMI, no-LMI) to explore whether KI enhances LMI ability. The analysis methods of both experiments included classification accuracy (V-rest vs. rest, no-LMI vs. rest, KI-LMI vs. rest, KI-LMI vs. V-rest), time-domain features, oral questionnaire, statistic analysis and brain functional connectivity analysis. Research 1 verified that induced KI by vibrating Achilles tendon might be feasible, and provided a theoretical basis for applying KI to LMI-BCI paradigm, evidenced by oral questionnaire (Q1) and the independent effect of vibratory stimulation during rest task. The results of research 2 that KI enhanced mesial cortex activation and induced more intensive EEG features, evidenced by ERD power, topographical distribution, oral questionnaire (Q2 and Q3), and brain functional connectivity map. Additionally, the KI increased the offline accuracy of no-LMI/rest task by 6.88 to 82.19% (p < 0.001). The simulated online accuracy was also improved for most subjects (average accuracy for all subjects: 77.23% > 75.31%, and average F1_score for all subjects: 76.4% > 74.3%). The LMI-BCI paradigm of this study provides a novel approach to enhance LMI ability and accelerates the practical applications of the LMI-BCI system.
Collapse
Affiliation(s)
- Weizhen Wang
- Institute of Robotics and Intelligent Systems, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Bin Shi
- Institute of Robotics and Intelligent Systems, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Dong Wang
- Institute of Robotics and Intelligent Systems, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Jing Wang
- Institute of Robotics and Intelligent Systems, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Gang Liu
- Henan Key Laboratory of Brain Science and Brain-Computer Interface Technology, School of Electrical Engineering, Zhengzhou University, Zhengzhou, China
| |
Collapse
|
5
|
Syrov N, Yakovlev L, Miroshnikov A, Kaplan A. Beyond passive observation: feedback anticipation and observation activate the mirror system in virtual finger movement control via P300-BCI. Front Hum Neurosci 2023; 17:1180056. [PMID: 37213933 PMCID: PMC10192585 DOI: 10.3389/fnhum.2023.1180056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 04/13/2023] [Indexed: 05/23/2023] Open
Abstract
Action observation (AO) is widely used as a post-stroke therapy to activate sensorimotor circuits through the mirror neuron system. However, passive observation is often considered to be less effective and less interactive than goal-directed movement observation, leading to the suggestion that observation of goal-directed actions may have stronger therapeutic potential, as goal-directed AO has been shown to activate mechanisms for monitoring action errors. Some studies have also suggested the use of AO as a form of Brain-computer interface (BCI) feedback. In this study, we investigated the potential for observation of virtual hand movements within a P300-based BCI as a feedback system to activate the mirror neuron system. We also explored the role of feedback anticipation and estimation mechanisms during movement observation. Twenty healthy subjects participated in the study. We analyzed event-related desynchronization and synchronization (ERD/S) of sensorimotor EEG rhythms and Error-related potentials (ErrPs) during observation of virtual hand finger flexion presented as feedback in the P300-BCI loop and compared the dynamics of ERD/S and ErrPs during observation of correct feedback and errors. We also analyzed these EEG markers during passive AO under two conditions: when subjects anticipated the action demonstration and when the action was unexpected. A pre-action mu-ERD was found both before passive AO and during action anticipation within the BCI loop. Furthermore, a significant increase in beta-ERS was found during AO within incorrect BCI feedback trials. We suggest that the BCI feedback may exaggerate the passive-AO effect, as it engages feedback anticipation and estimation mechanisms as well as movement error monitoring simultaneously. The results of this study provide insights into the potential of P300-BCI with AO-feedback as a tool for neurorehabilitation.
Collapse
Affiliation(s)
- Nikolay Syrov
- V. Zelman Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology, Moscow, Russia
- Baltic Center for Neurotechnology and Artificial Intelligence, Immanuel Kant Baltic Federal University, Kaliningrad, Russia
- *Correspondence: Nikolay Syrov,
| | - Lev Yakovlev
- V. Zelman Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology, Moscow, Russia
- Baltic Center for Neurotechnology and Artificial Intelligence, Immanuel Kant Baltic Federal University, Kaliningrad, Russia
| | - Andrei Miroshnikov
- Baltic Center for Neurotechnology and Artificial Intelligence, Immanuel Kant Baltic Federal University, Kaliningrad, Russia
| | - Alexander Kaplan
- V. Zelman Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology, Moscow, Russia
- Baltic Center for Neurotechnology and Artificial Intelligence, Immanuel Kant Baltic Federal University, Kaliningrad, Russia
- Department of Human and Animal Physiology, Faculty of Biology, Lomonosov Moscow State University, Moscow, Russia
| |
Collapse
|
6
|
Triana-Guzman N, Orjuela-Cañon AD, Jutinico AL, Mendoza-Montoya O, Antelis JM. Decoding EEG rhythms offline and online during motor imagery for standing and sitting based on a brain-computer interface. Front Neuroinform 2022; 16:961089. [PMID: 36120085 PMCID: PMC9481272 DOI: 10.3389/fninf.2022.961089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Accepted: 08/03/2022] [Indexed: 12/02/2022] Open
Abstract
Motor imagery (MI)-based brain-computer interface (BCI) systems have shown promising advances for lower limb motor rehabilitation. The purpose of this study was to develop an MI-based BCI for the actions of standing and sitting. Thirty-two healthy subjects participated in the study using 17 active EEG electrodes. We used a combination of the filter bank common spatial pattern (FBCSP) method and the regularized linear discriminant analysis (RLDA) technique for decoding EEG rhythms offline and online during motor imagery for standing and sitting. The offline analysis indicated the classification of motor imagery and idle state provided a mean accuracy of 88.51 ± 1.43% and 85.29 ± 1.83% for the sit-to-stand and stand-to-sit transitions, respectively. The mean accuracies of the sit-to-stand and stand-to-sit online experiments were 94.69 ± 1.29% and 96.56 ± 0.83%, respectively. From these results, we believe that the MI-based BCI may be useful to future brain-controlled standing systems.
Collapse
Affiliation(s)
| | | | - Andres L. Jutinico
- Facultad de Ingeniería Mecánica, Electrónica y Biomédica, Universidad Antonio Nariño, Bogota, Colombia
| | - Omar Mendoza-Montoya
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey, Mexico
- *Correspondence: Omar Mendoza-Montoya
| | - Javier M. Antelis
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey, Mexico
| |
Collapse
|
7
|
Gantenbein J, Dittli J, Meyer JT, Gassert R, Lambercy O. Intention Detection Strategies for Robotic Upper-Limb Orthoses: A Scoping Review Considering Usability, Daily Life Application, and User Evaluation. Front Neurorobot 2022; 16:815693. [PMID: 35264940 PMCID: PMC8900616 DOI: 10.3389/fnbot.2022.815693] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 01/24/2022] [Indexed: 11/13/2022] Open
Abstract
Wearable robotic upper limb orthoses (ULO) are promising tools to assist or enhance the upper-limb function of their users. While the functionality of these devices has continuously increased, the robust and reliable detection of the user's intention to control the available degrees of freedom remains a major challenge and a barrier for acceptance. As the information interface between device and user, the intention detection strategy (IDS) has a crucial impact on the usability of the overall device. Yet, this aspect and the impact it has on the device usability is only rarely evaluated with respect to the context of use of ULO. A scoping literature review was conducted to identify non-invasive IDS applied to ULO that have been evaluated with human participants, with a specific focus on evaluation methods and findings related to functionality and usability and their appropriateness for specific contexts of use in daily life. A total of 93 studies were identified, describing 29 different IDS that are summarized and classified according to a four-level classification scheme. The predominant user input signal associated with the described IDS was electromyography (35.6%), followed by manual triggers such as buttons, touchscreens or joysticks (16.7%), as well as isometric force generated by residual movement in upper-limb segments (15.1%). We identify and discuss the strengths and weaknesses of IDS with respect to specific contexts of use and highlight a trade-off between performance and complexity in selecting an optimal IDS. Investigating evaluation practices to study the usability of IDS, the included studies revealed that, primarily, objective and quantitative usability attributes related to effectiveness or efficiency were assessed. Further, it underlined the lack of a systematic way to determine whether the usability of an IDS is sufficiently high to be appropriate for use in daily life applications. This work highlights the importance of a user- and application-specific selection and evaluation of non-invasive IDS for ULO. For technology developers in the field, it further provides recommendations on the selection process of IDS as well as to the design of corresponding evaluation protocols.
Collapse
Affiliation(s)
- Jessica Gantenbein
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Jan Dittli
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Jan Thomas Meyer
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Roger Gassert
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
- Future Health Technologies, Singapore-ETH Centre, Campus for Research Excellence and Technological Enterprise (CREATE), Singapore, Singapore
| | - Olivier Lambercy
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
- Future Health Technologies, Singapore-ETH Centre, Campus for Research Excellence and Technological Enterprise (CREATE), Singapore, Singapore
| |
Collapse
|
8
|
Gutierrez-Martinez J, Mercado-Gutierrez JA, Carvajal-Gámez BE, Rosas-Trigueros JL, Contreras-Martinez AE. Artificial Intelligence Algorithms in Visual Evoked Potential-Based Brain-Computer Interfaces for Motor Rehabilitation Applications: Systematic Review and Future Directions. Front Hum Neurosci 2021; 15:772837. [PMID: 34899220 PMCID: PMC8656949 DOI: 10.3389/fnhum.2021.772837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 11/04/2021] [Indexed: 11/13/2022] Open
Abstract
Brain-Computer Interface (BCI) is a technology that uses electroencephalographic (EEG) signals to control external devices, such as Functional Electrical Stimulation (FES). Visual BCI paradigms based on P300 and Steady State Visually Evoked potentials (SSVEP) have shown high potential for clinical purposes. Numerous studies have been published on P300- and SSVEP-based non-invasive BCIs, but many of them present two shortcomings: (1) they are not aimed for motor rehabilitation applications, and (2) they do not report in detail the artificial intelligence (AI) methods used for classification, or their performance metrics. To address this gap, in this paper the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) methodology was applied to prepare a systematic literature review (SLR). Papers older than 10 years, repeated or not related to a motor rehabilitation application, were excluded. Of all the studies, 51.02% referred to theoretical analysis of classification algorithms. Of the remaining, 28.48% were for spelling, 12.73% for diverse applications (control of wheelchair or home appliances), and only 7.77% were focused on motor rehabilitation. After the inclusion and exclusion criteria were applied and quality screening was performed, 34 articles were selected. Of them, 26.47% used the P300 and 55.8% the SSVEP signal. Five applications categories were established: Rehabilitation Systems (17.64%), Virtual Reality environments (23.52%), FES (17.64%), Orthosis (29.41%), and Prosthesis (11.76%). Of all the works, only four performed tests with patients. The most reported machine learning (ML) algorithms used for classification were linear discriminant analysis (LDA) (48.64%) and support vector machine (16.21%), while only one study used a deep learning algorithm: a Convolutional Neural Network (CNN). The reported accuracy ranged from 38.02 to 100%, and the Information Transfer Rate from 1.55 to 49.25 bits per minute. While LDA is still the most used AI algorithm, CNN has shown promising results, but due to their high technical implementation requirements, many researchers do not justify its implementation as worthwile. To achieve quick and accurate online BCIs for motor rehabilitation applications, future works on SSVEP-, P300-based and hybrid BCIs should focus on optimizing the visual stimulation module and the training stage of ML and DL algorithms.
Collapse
Affiliation(s)
- Josefina Gutierrez-Martinez
- División de Investigación en Ingeniería Médica, Instituto Nacional de Rehabilitación Luis Guillermo Ibarra Ibarra, Mexico City, Mexico
| | - Jorge A. Mercado-Gutierrez
- División de Investigación en Ingeniería Médica, Instituto Nacional de Rehabilitación Luis Guillermo Ibarra Ibarra, Mexico City, Mexico
| | | | | | | |
Collapse
|
9
|
Perez-Ortiz CX, Gordillo JL, Mendoza-Montoya O, Antelis JM, Caraza R, Martinez HR. Functional Connectivity and Frequency Power Alterations during P300 Task as a Result of Amyotrophic Lateral Sclerosis. SENSORS (BASEL, SWITZERLAND) 2021; 21:6801. [PMID: 34696014 PMCID: PMC8541445 DOI: 10.3390/s21206801] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 09/22/2021] [Accepted: 09/26/2021] [Indexed: 12/01/2022]
Abstract
Amyotrophic Lateral Sclerosis (ALS) is one of the most aggressive neurodegenerative diseases and is now recognized as a multisystem network disorder with impaired connectivity. Further research for the understanding of the nature of its cognitive affections is necessary to monitor and detect the disease, so this work provides insight into the neural alterations occurring in ALS patients during a cognitive task (P300 oddball paradigm) by measuring connectivity and the power and latency of the frequency-specific EEG activity of 12 ALS patients and 16 healthy subjects recorded during the use of a P300-based BCI to command a robotic arm. For ALS patients, in comparison to Controls, the results (p < 0.05) were: an increment in latency of the peak ERP in the Delta range (OZ) and Alpha range (PO7), and a decreased power in the Beta band among most electrodes; connectivity alterations among all bands, especially in the Alpha band between PO7 and the channels above the motor cortex. The evolution observed over months of an advanced-state patient backs up these findings. These results were used to compute connectivity- and power-based features to discriminate between ALS and Control groups using Support Vector Machine (SVM). Cross-validation achieved a 100% in specificity and 75% in sensitivity, with an overall 89% success.
Collapse
Affiliation(s)
- Claudia X. Perez-Ortiz
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Monterrey 64849, Mexico; (C.X.P.-O.); (J.L.G.); (J.M.A.)
| | - Jose L. Gordillo
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Monterrey 64849, Mexico; (C.X.P.-O.); (J.L.G.); (J.M.A.)
| | - Omar Mendoza-Montoya
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Monterrey 64849, Mexico; (C.X.P.-O.); (J.L.G.); (J.M.A.)
| | - Javier M. Antelis
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Monterrey 64849, Mexico; (C.X.P.-O.); (J.L.G.); (J.M.A.)
| | - Ricardo Caraza
- Escuela de Medicina y Ciencias de la Salud, Tecnologico de Monterrey, Monterrey 64849, Mexico; (R.C.); (H.R.M.)
| | - Hector R. Martinez
- Escuela de Medicina y Ciencias de la Salud, Tecnologico de Monterrey, Monterrey 64849, Mexico; (R.C.); (H.R.M.)
| |
Collapse
|
10
|
Jamil N, Belkacem AN, Ouhbi S, Lakas A. Noninvasive Electroencephalography Equipment for Assistive, Adaptive, and Rehabilitative Brain-Computer Interfaces: A Systematic Literature Review. SENSORS (BASEL, SWITZERLAND) 2021; 21:4754. [PMID: 34300492 PMCID: PMC8309653 DOI: 10.3390/s21144754] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 06/28/2021] [Accepted: 07/09/2021] [Indexed: 11/30/2022]
Abstract
Humans interact with computers through various devices. Such interactions may not require any physical movement, thus aiding people with severe motor disabilities in communicating with external devices. The brain-computer interface (BCI) has turned into a field involving new elements for assistive and rehabilitative technologies. This systematic literature review (SLR) aims to help BCI investigator and investors to decide which devices to select or which studies to support based on the current market examination. This examination of noninvasive EEG devices is based on published BCI studies in different research areas. In this SLR, the research area of noninvasive BCIs using electroencephalography (EEG) was analyzed by examining the types of equipment used for assistive, adaptive, and rehabilitative BCIs. For this SLR, candidate studies were selected from the IEEE digital library, PubMed, Scopus, and ScienceDirect. The inclusion criteria (IC) were limited to studies focusing on applications and devices of the BCI technology. The data used herein were selected using IC and exclusion criteria to ensure quality assessment. The selected articles were divided into four main research areas: education, engineering, entertainment, and medicine. Overall, 238 papers were selected based on IC. Moreover, 28 companies were identified that developed wired and wireless equipment as means of BCI assistive technology. The findings of this review indicate that the implications of using BCIs for assistive, adaptive, and rehabilitative technologies are encouraging for people with severe motor disabilities and healthy people. With an increasing number of healthy people using BCIs, other research areas, such as the motivation of players when participating in games or the security of soldiers when observing certain areas, can be studied and collaborated using the BCI technology. However, such BCI systems must be simple (wearable), convenient (sensor fabrics and self-adjusting abilities), and inexpensive.
Collapse
Affiliation(s)
- Nuraini Jamil
- Department of Computer Science and Software Engineering, College of Information Technology, United Arab Emirates University, Al Ain P.O. Box 15551, United Arab Emirates; (N.J.); (S.O.)
| | - Abdelkader Nasreddine Belkacem
- Department of Computer and Network Engineering, College of Information Technology, United Arab Emirates University, Al Ain P.O. Box 15551, United Arab Emirates;
| | - Sofia Ouhbi
- Department of Computer Science and Software Engineering, College of Information Technology, United Arab Emirates University, Al Ain P.O. Box 15551, United Arab Emirates; (N.J.); (S.O.)
| | - Abderrahmane Lakas
- Department of Computer and Network Engineering, College of Information Technology, United Arab Emirates University, Al Ain P.O. Box 15551, United Arab Emirates;
| |
Collapse
|
11
|
Holanda LJ, Fernandes APM, de Amorim JA, Matias AM, Nunes Netto SP, Nagem DAP, Valentim RADM, Morya E, Lindquist AR. Adaptive Algorithms as Control Strategies of Smart Upper Limb Orthosis: A Protocol for a Systematic Scoping Review. Front Neurosci 2021; 15:660141. [PMID: 34025344 PMCID: PMC8138030 DOI: 10.3389/fnins.2021.660141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Accepted: 04/09/2021] [Indexed: 11/13/2022] Open
Abstract
Introduction: Adaptive algorithms for controlling orthosis emerged to overcome significant problems with automatic biosignal classification and personalized rehabilitation. Smart orthoses are evolving fast and need a better human-machine interaction performance since biosignals, feedback, and motor control dynamically change and must be adaptive. This manuscript outlines a scoping review protocol to systematically review the smart upper limb (UL) orthoses based on adaptive algorithms and feasibility tests. Materials and Methods: This protocol was developed based on the York framework. A field-specific structure was defined to achieve each phase. Eleven scientific databases (PubMed, Web of Science, SciELO, Koreamed, Jstage, AMED, CENTRAL, PEDro, IEEE, Scopus, and Arxiv) and five patent databases (Patentscope, Patentlens, Google Patents, Kripis, J-platpat) were searched. The developed framework will extract data (i.e., orthosis description, adaptive algorithms, tools used in the usability test, and benefits to the general population) from the selected studies using a rigorous approach. Data will be described quantitatively using frequency and trend analysis methods. Heterogeneity between the included studies will be assessed using the Chi-test and I-statistic. The risk of bias will be summarized using the latest Prediction Model Study Risk of Bias Assessment Tool. Discussion: This review will identify, map, and synthesize the advances about the description of adaptive algorithms for control strategies of smart UL orthosis using data extracted from patents and articles.
Collapse
Affiliation(s)
- Ledycnarf J Holanda
- Laboratory of Intervention and Analysis of Movement, Department of Physical Therapy, Federal University of Rio Grande do Norte, Natal, Brazil.,Laboratory of Technological Innovation in Health, Federal University of Rio Grande do Norte, Natal, Brazil
| | - Ana Paula M Fernandes
- Laboratory of Intervention and Analysis of Movement, Department of Physical Therapy, Federal University of Rio Grande do Norte, Natal, Brazil.,Laboratory of Technological Innovation in Health, Federal University of Rio Grande do Norte, Natal, Brazil
| | - Júlia A de Amorim
- Laboratory of Technological Innovation in Health, Federal University of Rio Grande do Norte, Natal, Brazil.,Department of Biomedical Engineering, Federal University of Rio Grande do Norte, Natal, Brazil
| | - Aryel M Matias
- Laboratory of Technological Innovation in Health, Federal University of Rio Grande do Norte, Natal, Brazil
| | - Severino P Nunes Netto
- Laboratory of Technological Innovation in Health, Federal University of Rio Grande do Norte, Natal, Brazil
| | - Danilo A P Nagem
- Laboratory of Technological Innovation in Health, Federal University of Rio Grande do Norte, Natal, Brazil.,Department of Biomedical Engineering, Federal University of Rio Grande do Norte, Natal, Brazil
| | - Ricardo A de M Valentim
- Department of Biomedical Engineering, Federal University of Rio Grande do Norte, Natal, Brazil
| | - Edgard Morya
- Edmond and Lily Safra International Institute of Neurosciences, Santos Dumont Institute, Macaiba, Brazil
| | - Ana Raquel Lindquist
- Laboratory of Intervention and Analysis of Movement, Department of Physical Therapy, Federal University of Rio Grande do Norte, Natal, Brazil.,Laboratory of Technological Innovation in Health, Federal University of Rio Grande do Norte, Natal, Brazil
| |
Collapse
|
12
|
Chailloux Peguero JD, Mendoza-Montoya O, Antelis JM. Single-Option P300-BCI Performance Is Affected by Visual Stimulation Conditions. SENSORS (BASEL, SWITZERLAND) 2020; 20:E7198. [PMID: 33339105 PMCID: PMC7765532 DOI: 10.3390/s20247198] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 12/08/2020] [Accepted: 12/10/2020] [Indexed: 01/18/2023]
Abstract
The P300 paradigm is one of the most promising techniques for its robustness and reliability in Brain-Computer Interface (BCI) applications, but it is not exempt from shortcomings. The present work studied single-trial classification effectiveness in distinguishing between target and non-target responses considering two conditions of visual stimulation and the variation of the number of symbols presented to the user in a single-option visual frame. In addition, we also investigated the relationship between the classification results of target and non-target events when training and testing the machine-learning model with datasets containing different stimulation conditions and different number of symbols. To this end, we designed a P300 experimental protocol considering, as conditions of stimulation: the color highlighting or the superimposing of a cartoon face and from four to nine options. These experiments were carried out with 19 healthy subjects in 3 sessions. The results showed that the Event-Related Potentials (ERP) responses and the classification accuracy are stronger with cartoon faces as stimulus type and similar irrespective of the amount of options. In addition, the classification performance is reduced when using datasets with different type of stimulus, but it is similar when using datasets with different the number of symbols. These results have a special connotation for the design of systems, in which it is intended to elicit higher levels of evoked potentials and, at the same time, optimize training time.
Collapse
|