1
|
Okamoto H, Wakita A, Tani K, Kito S, Kurooka M, Kodama T, Tohyama N, Fujita Y, Nakamura S, Iijima K, Chiba T, Nakayama H, Murata M, Goka T, Igaki H. Plan complexity metrics for head and neck VMAT competition plans. Med Dosim 2024; 49:244-253. [PMID: 38368182 DOI: 10.1016/j.meddos.2024.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 12/22/2023] [Accepted: 01/24/2024] [Indexed: 02/19/2024]
Abstract
Previous plan competitions have largely focused on dose metric assessments. However, whether the submitted plans were realistic and reasonable from a quality assurance (QA) perspective remains unclear. This study aimed to investigate the relationship between aperture-based plan complexity metrics (PCM) in volumetric modulated arc therapy (VMAT) competition plans and clinical treatment plans verified through patient-specific QA (PSQA). In addition, the association of PCMs with plan quality was examined. A head and neck (HN) plan competition was held for Japanese institutions from June 2019 to July 2019, in which 210 competition plans were submitted. Dose distribution quality was quantified based on dose-volume histogram (DVH) metrics by calculating the dose distribution plan score (DDPS). Differences in PCMs between the two VMAT treatment plan groups (HN plan competitions held in Japan and clinically accepted HN VMAT plans through PSQA) were investigated. The mean (± standard deviation) DDPS for the 98 HN competition plans was 158.5 ± 20.6 (maximum DDPS: 200). DDPS showed a weak correlation with PCMs with a maximum r of 0.45 for monitor unit (MU); its correlation with some PCMs was "very weak." Significant differences were found in some PCMs between plans with the highest 20% DDPSs and the remaining plans. The clinical VMAT and competition plans revealed similar distributions for some PCMs. Deviations in PCMs for the two groups were comparable, indicating considerable variability among planners regarding planning skills. The plan complexity for HN VMAT competition plans increased for high-quality plans, as shown by the dose distribution. Direct comparison of PCMs between competition plans and clinically accepted plans showed that the submitted HN VMAT competition plans were realistic and reasonable from the QA perspective. This evaluation may provide a set of criteria for evaluating plan quality in plan competitions.
Collapse
Affiliation(s)
- Hiroyuki Okamoto
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan.
| | - Akihisa Wakita
- Division of Medical Physics, EuroMediTech Co., LTD., 2-20-4 higashigotanda, shinagawa-ku Tokyo, 141-0022, Japan
| | - Kensuke Tani
- Division of Medical Physics, EuroMediTech Co., LTD., 2-20-4 higashigotanda, shinagawa-ku Tokyo, 141-0022, Japan
| | - Satoshi Kito
- Department of Radiology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, 3-18-22 Honkomagome, Bunkyo-ku Tokyo,113-8677, Japan
| | - Masahiko Kurooka
- Department of Radiation Therapy, Tokyo Medical University Hospital, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo 160-0023, Japan
| | - Takumi Kodama
- Department of Radiation Oncology, Saitama Cancer Center, 780 Ooazakomuro, Inamachi, Kitaadachi-gun Saitama 362-0806, Japan
| | - Naoki Tohyama
- Division of Medical Physics, Tokyo Bay Makuhari Clinic for Advanced Imaging, Cancer Screening, and High-Precision Radiotherapy, 1-17 Toyosuna, Mihama-ku Chiba, Chiba, 261-0024, Japan
| | - Yukio Fujita
- Department of Radiation Sciences, Komazawa University, 1-23-1, komazawa, setagaya-ku Tokyo, 154-8525, Japan
| | - Satoshi Nakamura
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Kotaro Iijima
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Takahito Chiba
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Hiroki Nakayama
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Miyuki Murata
- Department of Radiological Technology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Tomonori Goka
- Department of Radiological Technology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Hiroshi Igaki
- Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| |
Collapse
|
2
|
Hirotaki K, Tomizawa K, Moriya S, Oyoshi H, Raturi V, Ito M, Sakae T. Fully automated volumetric modulated arc therapy planning for locally advanced rectal cancer: feasibility and efficiency. Radiat Oncol 2023; 18:147. [PMID: 37670390 PMCID: PMC10481560 DOI: 10.1186/s13014-023-02334-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 08/21/2023] [Indexed: 09/07/2023] Open
Abstract
BACKGROUND Volumetric modulated arc therapy (VMAT) for locally advanced rectal cancer (LARC) has emerged as a promising technique, but the planning process can be time-consuming and dependent on planner expertise. We aimed to develop a fully automated VMAT planning program for LARC and evaluate its feasibility and efficiency. METHODS A total of 26 LARC patients who received VMAT treatment and the computed tomography (CT) scans were included in this study. Clinical target volumes and organs at risk were contoured by radiation oncologists. The automatic planning program, developed within the Raystation treatment planning system, used scripting capabilities and a Python environment to automate the entire planning process. The automated VMAT plan (auto-VMAT) was created by our automated planning program with the 26 CT scans used in the manual VMAT plan (manual-VMAT) and their regions of interests. Dosimetric parameters and time efficiency were compared between the auto-VMAT and the manual-VMAT created by experienced planners. All results were analyzed using the Wilcoxon signed-rank sum test. RESULTS The auto-VMAT achieved comparable coverage of the target volume while demonstrating improved dose conformity and uniformity compared with the manual-VMAT. V30 and V40 in the small bowel were significantly lower in the auto-VMAT compared with those in the manual-VMAT (p < 0.001 and < 0.001, respectively); the mean dose of the bladder was also significantly reduced in the auto-VMAT (p < 0.001). Furthermore, auto-VMAT plans were consistently generated with less variability in quality. In terms of efficiency, the auto-VMAT markedly reduced the time required for planning and expedited plan approval, with 93% of cases approved within one day. CONCLUSION We developed a fully automatic feasible VMAT plan creation program for LARC. The auto-VMAT maintained target coverage while providing organs at risk dose reduction. The developed program dramatically reduced the time to approval.
Collapse
Affiliation(s)
- Kouta Hirotaki
- Doctoral Program in Medical Sciences, Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki, Japan
- Department of Radiological Technology, National Cancer Center Hospital East, Chiba, Japan
| | - Kento Tomizawa
- Department of Radiation Oncology, National Cancer Center Hospital East, 6-5-1, Kashiwanoha, 277-8577, Kashiwa, Chiba, Japan.
| | | | - Hajime Oyoshi
- Department of Radiological Technology, National Cancer Center Hospital East, Chiba, Japan
| | - Vijay Raturi
- Department of Radiation Oncology, Apollomedics Hospital, Lucknow, India
| | - Masashi Ito
- Department of Radiological Technology, National Cancer Center Hospital East, Chiba, Japan
| | - Takeji Sakae
- Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| |
Collapse
|
3
|
Olch AJ, Gopalakrishnan M, Murphy ES, MacDonald SM, Hua CH. Toward Systematic Assessment and Improvement of Radiation Therapy Plan Quality of Cooperative Group Trial Submissions: A Report From the Children's Oncology Group. Pract Radiat Oncol 2023; 13:e374-e382. [PMID: 37037758 PMCID: PMC11163894 DOI: 10.1016/j.prro.2023.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 01/30/2023] [Accepted: 02/02/2023] [Indexed: 04/12/2023]
Abstract
PURPOSE This study evaluates the quality of plans used for the treatment of patients in the Children's Oncology Group study ACNS1123. Plan quality is quantified based on a scoring system specific to the protocol. In this way, the distribution of plan quality scores is determined that can be used to identify plan quality issues for this study and for future plan quality improvement. METHODS AND MATERIALS ACNS1123 stratum 1 patients (70) were evaluated. This included 50 photon and 20 proton plans. Digital Imaging and Communications in Medicine (DICOM) structure and dose data were obtained from the Children's Oncology Group. A commercially available plan quality scoring algorithm was used to create a scoring system we designed using the protocol dosimetric requirements. The whole ventricle and boost planning target volumes (PTVs) could earn a maximum of 70 points, whereas the organs at risk could earn 30 points (total maximum score of 100 points). The scoring algorithm adjusted scores based on the difficulty in achieving the structure dose requirements, which depended on the proximity of the PTVs and the dose gradients achieved relative to the organs at risk. The distribution of plan scores was used to determine the mean, median, and range of scores. RESULTS The median adjusted plan quality scores for the 20 proton and 50 photon plans were 83.3 and 86.9, respectively. The range of adjusted scores (maximum to minimum) was 50 points. The average score adjustment was 7.4 points. Photon and proton plans performed almost equally. Average plan quality by individual structure revealed that the brain stem, PTV boost, and cochlea lost the most points. CONCLUSIONS This report is the first to systematically analyze overall radiation therapy plan quality scores for an entire cohort of patients treated in a cooperative group clinical trial. The methodology demonstrated a large variation in plan quality in this trial. Future clinical trials could potentially use this method to reduce plan quality variability, which may improve outcomes.
Collapse
Affiliation(s)
- Arthur J Olch
- Department of Radiation Oncology, University of Southern California and Children's Hospital Los Angeles, Los Angeles, California.
| | | | - Erin S Murphy
- Department of Radiation Oncology, Cleveland Clinic, Cleveland, Ohio
| | - Shannon M MacDonald
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - Chia-Ho Hua
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, Tennessee
| |
Collapse
|
4
|
Li Y, Li X, Yang J, Wang S, Tang M, Xia J, Gao Y. Flourish of Proton and Carbon Ion Radiotherapy in China. Front Oncol 2022; 12:819905. [PMID: 35237518 PMCID: PMC8882681 DOI: 10.3389/fonc.2022.819905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 01/24/2022] [Indexed: 11/13/2022] Open
Abstract
Proton and heavy ion therapy offer superior relative biological effectiveness (RBE) in the treatment of deep-seated tumors compared with conventional photon radiotherapy due to its Bragg-peak feature of energy deposition in organs. Many proton and carbon ion therapy centers are active all over the world. At present, five particle radiotherapy institutes have been built and are receiving patient in China, mainly including Wanjie Proton Therapy Center (WPTC), Shanghai Proton Heavy Ion Center (SPHIC), Heavy Ion Cancer Treatment Center (HIMM), Chang Gung Memorial Hospital (CGMH), and Ruijin Hospital affiliated with Jiao Tong University. Many cancer patients have benefited from ion therapy, showing unique advantages over surgery and chemotherapy. By the end of 2020, nearly 8,000 patients had been treated with proton, carbon ion or carbon ion combined with proton therapy. So far, there is no systemic review for proton and carbon ion therapy facility and clinical outcome in China. We reviewed the development of proton and heavy ion therapy, as well as providing the representative clinical data and future directions for particle therapy in China. It has important guiding significance for the design and construction of new particle therapy center and patients’ choice of treatment equipment.
Collapse
Affiliation(s)
- Yue Li
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- *Correspondence: Yue Li,
| | - Xiaoman Li
- Department of Radiation Medicine, School of Basic Medical Sciences, Peking University Health Science Center, Beijing, China
| | - Jiancheng Yang
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
| | - Sicheng Wang
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
| | - Meitang Tang
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
| | - Jiawen Xia
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- Huizhou Research Center of Ion Science, Chinese Academy of Sciences, Huizhou, China
| | - Yunzhe Gao
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing, China
| |
Collapse
|