1
|
Liu S, Zhang Y, Liu W, Yin T, Yuan J, Ran J, Li X. Simultaneous multi-slice technique for reducing acquisition times in diffusion tensor imaging of the knee: a feasibility study. Skeletal Radiol 2024:10.1007/s00256-024-04719-y. [PMID: 38913177 DOI: 10.1007/s00256-024-04719-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 05/30/2024] [Accepted: 05/30/2024] [Indexed: 06/25/2024]
Abstract
OBJECTIVES To explore the feasibility of simultaneous multi-slice (SMS) technique for reducing acquisition times in readout-segmented echo planar imaging (RESOLVE) for diffusion tensor imaging (DTI) of the knee. MATERIALS AND METHODS A total of 30 healthy volunteers and 23 patients with knee acute injury (12 cases with anterior ligament (ACL) tears and 16 cases with patellar cartilage (PC) injury) were enrolled in this prospective study. Three DTI protocols were used: conventional RESOLVE-DTI with 12 directions (protocol 1), SMS-RESOLVE-DTI with 12 directions (protocol 2) and 20 directions (protocol 3). DTI parameters of gastrocnemius, ACL and posterior cruciate ligament (PCL), and PC from three protocols were quantitatively assessed. RESULTS For volunteers, protocol 2 significantly reduced acquisition time by 38.6% and 34.2% compared to protocols 1 and 3 while maintaining similar high-quality images and similar diffusive parameters, except for the fractional anisotropy (FA) and axial diffusivity (AD) of the PC between protocols 2 and 1 (P < 0.05). For injured ACL and PC, protocols 1 and 2 showed similar accurate diffusive parameters (except for AD, P = 0.025) and similar diagnostic efficacy, which demonstrated significantly lower FA and higher radial diffusivity (RD) in protocols 1 and 2 compared to volunteers (P < 0.05). CONCLUSIONS The 12-direction SMS-RESOLVE-DTI demonstrated a favorable balance between acquisition time and image quality, making it a promising alternative to conventional DTI for evaluating ligament and cartilage injuries. ADVANCES IN KNOWLEDGE The SMS technique greatly reduces acquisition time while maintaining image quality, which signified the possibility of DTI's clinical application.
Collapse
Affiliation(s)
- Simin Liu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No.1095, Jiefang Road, Wuhan, Hubei Province, China
| | - Yao Zhang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No.1095, Jiefang Road, Wuhan, Hubei Province, China
| | - Wei Liu
- MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd., No. 32 Gaoxin C. Ave., 2nd, Shenzhen, China
| | - Ting Yin
- MR Collaborations, Siemens Healthineers Ltd., Chengdu, China
| | - Jie Yuan
- Department of Radiology, Zhongxiang People's Hospital, Zhongxiang City, China
| | - Jun Ran
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No.1095, Jiefang Road, Wuhan, Hubei Province, China.
| | - Xiaoming Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No.1095, Jiefang Road, Wuhan, Hubei Province, China.
| |
Collapse
|
2
|
Vashistha R, Almuqbel MM, Palmer NJ, Keenan RJ, Gilbert K, Wells S, Lynch A, Li A, Kingston-Smith S, Melzer TR, Koerzdoerfer G, O'Brien K. Evaluation of deep-learning TSE images in clinical musculoskeletal imaging. J Med Imaging Radiat Oncol 2024. [PMID: 38837669 DOI: 10.1111/1754-9485.13714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 05/15/2024] [Indexed: 06/07/2024]
Abstract
In this study, we compared the fat-saturated (FS) and non-FS turbo spin echo (TSE) magnetic resonance imaging knee sequences reconstructed conventionally (conventional-TSE) against a deep learning-based reconstruction of accelerated TSE (DL-TSE) scans. A total of 232 conventional-TSE and DL-TSE image pairs were acquired for comparison. For each consenting patient, one of the clinically acquired conventional-TSE proton density-weighted sequences in the sagittal or coronal planes (FS and non-FS), or in the axial plane (non-FS), was repeated using a research DL-TSE sequence. The DL-TSE reconstruction resulted in an image resolution that increased by at least 45% and scan times that were up to 52% faster compared to the conventional TSE. All images were acquired on a MAGNETOM Vida 3T scanner (Siemens Healthineers AG, Erlangen, Germany). The reporting radiologists, blinded to the acquisition time, were requested to qualitatively compare the DL-TSE against the conventional-TSE reconstructions. Despite having a faster acquisition time, the DL-TSE was rated to depict smaller structures better for 139/232 (60%) cases, equivalent for 72/232 (31%) cases and worse for 21/232 (9%) cases compared to the conventional-TSE. Overall, the radiologists preferred the DL-TSE reconstruction in 124/232 (53%) cases and stated no preference, implying equivalence, for 65/232 (28%) cases. DL-TSE reconstructions enabled faster acquisition times while enhancing spatial resolution and preserving the image contrast. From these results, the DL-TSE provided added or comparable clinical value and utility in less time. DL-TSE offers the opportunity to further reduce the overall examination time and improve patient comfort with no loss in diagnostic accuracy.
Collapse
Affiliation(s)
- Rajat Vashistha
- ARC Centre for Innovation in Biomedical Imaging Technology, The University of Queensland, Brisbane, Queensland, Australia
- Siemens Healthcare Pty Ltd, Brisbane, Queensland, Australia
| | - Mustafa M Almuqbel
- Pacific Radiology Group, Christchurch, New Zealand
- New Zealand Brain Research Institute, Christchurch, New Zealand
- Department of Medicine, University of Otago, Christchurch, New Zealand
- South Australia Health and Medical Research Institute, Adelaide, South Australia, Australia
| | | | - Ross J Keenan
- Pacific Radiology Group, Christchurch, New Zealand
- Department of Radiology, Christchurch Hospital, Christchurch, New Zealand
| | | | - Scott Wells
- Pacific Radiology Group, Christchurch, New Zealand
| | - Andrew Lynch
- Pacific Radiology Group, Christchurch, New Zealand
| | - Andrew Li
- Pacific Radiology Group, Christchurch, New Zealand
| | | | - Tracy R Melzer
- New Zealand Brain Research Institute, Christchurch, New Zealand
- Department of Medicine, University of Otago, Christchurch, New Zealand
- School of Psychology, Speech and Hearing, University of Canterbury, Christchurch, New Zealand
| | | | - Kieran O'Brien
- ARC Centre for Innovation in Biomedical Imaging Technology, The University of Queensland, Brisbane, Queensland, Australia
- Siemens Healthcare Pty Ltd, Brisbane, Queensland, Australia
| |
Collapse
|
3
|
Zhang Y, Ye Z, Xia C, Tan Y, Zhang M, Lv X, Tang J, Li Z. Clinical Applications and Recent Updates of Simultaneous Multi-slice Technique in Accelerated MRI. Acad Radiol 2024; 31:1976-1988. [PMID: 38220568 DOI: 10.1016/j.acra.2023.12.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/15/2023] [Accepted: 12/19/2023] [Indexed: 01/16/2024]
Abstract
Simultaneous multi-slice (SMS) is a magnetic resonance imaging (MRI) acceleration technique that utilizes multi-band radio-frequency pulses to simultaneously excite and encode multiple slices. Currently, SMS has been widely studied and applied in the MRI examination to reduce acquisition time, which can significantly improve the examination efficiency and patient throughput. Moreover, SMS technique can improve spatial resolution, which is of great value in disease diagnosis, treatment response monitoring, and prognosis prediction. This review will briefly introduce the technical principles of SMS, and summarize its current clinical applications. More importantly, we will discuss the recent technical progress and future research direction of SMS, hoping to highlight the clinical value and scientific potential of this technique.
Collapse
Affiliation(s)
- Yiteng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zheng Ye
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Chunchao Xia
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Yuqi Tan
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Meng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Xinyang Lv
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Jing Tang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zhenlin Li
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China.
| |
Collapse
|
4
|
Bayne CO, Moontasri NJ, Boutin RD, Szabo RM. Advanced Arthritis of the Carpus: Preoperative Planning Practices of 337 Hand Surgeons. J Wrist Surg 2023; 12:517-521. [PMID: 38213560 PMCID: PMC10781575 DOI: 10.1055/s-0043-1764302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 01/30/2023] [Indexed: 01/13/2024]
Abstract
Background Surgical procedure selection for carpal arthritis depends on which articular surfaces are affected, but there is no consensus on how to preoperatively evaluate cartilage surfaces. Despite advances in cross-sectional imaging, the utility of advanced imaging for preoperative decision-making has not been well established. Objectives Our objective was to assess if there is an added value to presurgical advanced imaging or diagnostic procedures in planning for carpal arthrodesis or carpectomy and to determine what imaging or diagnostic procedures influence surgical treatment options. Methods A seven-question survey was sent to 2,400 hand surgeons. Questions assessed which articular surfaces surgeons consider important for decision-making, which imaging modalities surgeons employ, and how often surgeons utilize diagnostic arthroscopy before performing carpectomy or arthrodesis procedures. Results A total of 337 (14%) surveys were analyzed. The capitolunate articulation (alone or in combination) was most frequently reported to impact surgical decision-making (48.1%). Most surgeons (86.6%) reported that standard plain radiographs are usually sufficient. Few surgeons reported always obtaining magnetic resonance imaging (MRI) or computed tomography (CT), with 44.2% of surgeons believing that MRI is never useful and 38.4% believing that CT is never useful. Most surgeons (68.2%) reported that they never perform wrist arthroscopy as part of their decision-making process. Conclusions This study provides information on the decision-making process in the surgical management of carpal arthritis. Given advances in cross-sectional imaging, further studies are needed to determine the utility of MRI and CT for the planning of surgical procedures in the treatment of arthritis of the carpus. Level of Evidence Level 4.
Collapse
Affiliation(s)
- Christopher O. Bayne
- Department of Orthopaedic Surgery, UC Davis School of Medicine, Sacramento, California
| | - Nancy J. Moontasri
- Department of Orthopaedic Surgery, UC Davis School of Medicine, Sacramento, California
| | - Robert D. Boutin
- Department of Radiology, Stanford University School of Medicine, California
| | - Robert M. Szabo
- Department of Orthopaedic Surgery, UC Davis School of Medicine, Sacramento, California
| |
Collapse
|
5
|
Herrmann J, Gassenmaier S, Keller G, Koerzdoerfer G, Almansour H, Nickel D, Othman A, Afat S, Werner S. Deep Learning MRI Reconstruction for Accelerating Turbo Spin Echo Hand and Wrist Imaging: A Comparison of Image Quality, Visualization of Anatomy, and Detection of Common Pathologies with Standard Imaging. Acad Radiol 2023; 30:2606-2615. [PMID: 36797172 DOI: 10.1016/j.acra.2022.12.042] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/20/2022] [Accepted: 12/26/2022] [Indexed: 02/16/2023]
Abstract
RATIONALE AND OBJECTIVES Magnetic resonance imaging (MRI) of the hand and wrist is a routine MRI examination and takes about 15-20 minutes, which can lead to problems resulting from the relatively long scan time, such as decreased image quality due to motion artifacts and lower patient throughput. The objective of this study was to evaluate a deep learning (DL) reconstruction for turbo spin echo (TSE) sequences of the hand and wrist regarding image quality, visualization of anatomy, and diagnostic performance concerning common pathologies. MATERIALS AND METHODS Twenty-one patients (mean age: 43 ± 19 [19-85] years, 10 men, 11 female) were prospectively enrolled in this study between October 2020 and June 2021. Each participant underwent two MRI protocols: first, standard fully sampled TSE sequences reconstructed with a standard GRAPPA reconstruction (TSES) and second, prospectively undersampled TSE sequences using a conventional parallel imaging undersampling pattern reconstructed with a DL reconstruction (TSEDL). Both protocols were acquired consecutively in one examination. Two experienced MSK-imaging radiologists qualitatively evaluated the images concerning image quality, noise, edge sharpness, artifacts, and diagnostic confidence, as well as the delineation of anatomical structures (triangular fibrocartilage complex, tendon of the extensor carpi ulnaris muscle, extrinsic and intrinsic ligaments, median nerve, cartilage) using a five-point Likert scale and assessed common pathologies. Wilcoxon signed-rank test and kappa statistics were performed to compare the sequences. RESULTS Overall image quality, artifacts, delineation of anatomical structures, and diagnostic confidence of TSEDL were rated to be comparable to TSES (p > 0.05). Additionally, TSEDL showed decreased image noise (4.90, median 5, IQR 5-5) compared to TSES (4.52, median 5, IQR 4-5, p < 0.05) and improved edge sharpness (TSEDL: 4.10, median 4, IQR 3.5-5; TSES: 3.57, median 4, IQR 3-4; p < 0.05). Inter- and intrareader agreement was substantial to almost perfect (κ = 0.632-1.000) for the detection of common pathologies. Time of acquisition could be reduced by more than 60% with the protocol using TSEDL. CONCLUSION Compared to TSES, TSEDL provided decreased noise and increased edge sharpness, equal image quality, delineation of anatomical structures, detection of pathologies, and diagnostic confidence. Therefore, TSEDL may be clinically relevant for hand and wrist imaging, as it reduces examination time by more than 60%, thus increasing patient comfort and patient throughput.
Collapse
Affiliation(s)
- Judith Herrmann
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany
| | - Sebastian Gassenmaier
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany
| | - Gabriel Keller
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany
| | | | - Haidara Almansour
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany
| | - Dominik Nickel
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Ahmed Othman
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany; Department of Neuroradiology, University Medical Center Mainz, Mainz, Germany
| | - Saif Afat
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany.
| | - Sebastian Werner
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany
| |
Collapse
|
6
|
Herrmann J, Afat S, Gassenmaier S, Koerzdoerfer G, Lingg A, Almansour H, Nickel D, Werner S. Image Quality and Diagnostic Performance of Accelerated 2D Hip MRI with Deep Learning Reconstruction Based on a Deep Iterative Hierarchical Network. Diagnostics (Basel) 2023; 13:3241. [PMID: 37892062 PMCID: PMC10606422 DOI: 10.3390/diagnostics13203241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 10/10/2023] [Accepted: 10/14/2023] [Indexed: 10/29/2023] Open
Abstract
OBJECTIVES Hip MRI using standard multiplanar sequences requires long scan times. Accelerating MRI is accompanied by reduced image quality. This study aimed to compare standard two-dimensional (2D) turbo spin echo (TSE) sequences with accelerated 2D TSE sequences with deep learning (DL) reconstruction (TSEDL) for routine clinical hip MRI at 1.5 and 3 T in terms of feasibility, image quality, and diagnostic performance. MATERIAL AND METHODS In this prospective, monocentric study, TSEDL was implemented clinically and evaluated in 14 prospectively enrolled patients undergoing a clinically indicated hip MRI at 1.5 and 3T between October 2020 and May 2021. Each patient underwent two examinations: For the first exam, we used standard sequences with generalized autocalibrating partial parallel acquisition reconstruction (TSES). For the second exam, we implemented prospectively undersampled TSE sequences with DL reconstruction (TSEDL). Two radiologists assessed the TSEDL and TSES regarding image quality, artifacts, noise, edge sharpness, diagnostic confidence, and delineation of anatomical structures using an ordinal five-point Likert scale (1 = non-diagnostic; 2 = poor; 3 = moderate; 4 = good; 5 = excellent). Both sequences were compared regarding the detection of common pathologies of the hip. Comparative analyses were conducted to assess the differences between TSEDL and TSES. RESULTS Compared with TSES, TSEDL was rated to be significantly superior in terms of image quality (p ≤ 0.020) with significantly reduced noise (p ≤ 0.001) and significantly improved edge sharpness (p = 0.003). No difference was found between TSES and TSEDL concerning the extent of artifacts, diagnostic confidence, or the delineation of anatomical structures (p > 0.05). Example acquisition time reductions for the TSE sequences of 52% at 3 Tesla and 70% at 1.5 Tesla were achieved. CONCLUSION TSEDL of the hip is clinically feasible, showing excellent image quality and equivalent diagnostic performance compared with TSES, reducing the acquisition time significantly.
Collapse
Affiliation(s)
- Judith Herrmann
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Saif Afat
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Sebastian Gassenmaier
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Gregor Koerzdoerfer
- MR Applications Predevelopment, Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052 Erlangen, Germany
| | - Andreas Lingg
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Haidara Almansour
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Dominik Nickel
- MR Applications Predevelopment, Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052 Erlangen, Germany
| | - Sebastian Werner
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| |
Collapse
|
7
|
Multi-level classification of knee cartilage lesion in multimodal MRI based on deep learning. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2023.104687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
|
8
|
Preisner F, Hayes JC, Charlet T, Carinci F, Hielscher T, Schwarz D, Vollherbst DF, Breckwoldt MO, Jesser J, Heiland S, Bendszus M, Hilgenfeld T. Simultaneous Multislice Accelerated TSE for Improved Spatiotemporal Resolution and Diagnostic Accuracy in Magnetic Resonance Neurography: A Feasibility Study. Invest Radiol 2023; 58:363-371. [PMID: 36729753 DOI: 10.1097/rli.0000000000000940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVES This study aims to evaluate the utility of simultaneous multislice (SMS) acceleration for routine magnetic resonance neurography (MRN) at 3 T. MATERIALS AND METHODS Patients with multiple sclerosis underwent MRN of the sciatic nerve consisting of a standard fat-saturated T2-weighted turbo spin echo (TSE) sequence using integrated parallel acquisition technique (PAT2) acceleration and 2 T2 TSE sequences using a combination of PAT-SMS acceleration (1) to reduce scan time (PAT2-SMS2; SMS-TSE FAST ) and (2) for time neutral increase of in-plane resolution (PAT1-SMS2; SMS-TSE HR ). Acquisition times were 5:29 minutes for the standard T2 TSE, 3:12 minutes for the SMS-TSE FAST , and 5:24 minutes for the SMS-TSE HR . Six qualitative imaging parameters were analyzed by 2 blinded readers using a 5-point Likert scale and T2 nerve lesions were quantified, respectively. Qualitative and quantitative image parameters were compared, and both interrater and intrarater reproducibility were statistically assessed. In addition, signal-to-noise ratio/contrast-to-noise ratio (CNR) was obtained in healthy controls using the exact same imaging protocol. RESULTS A total of 15 patients with MS (mean age ± standard deviation, 38.1 ± 11 years) and 10 healthy controls (mean age, 29.1 ± 7 years) were enrolled in this study. CNR analysis was highly reliable (intraclass correlation coefficient, 0.755-0.948) and revealed a significant CNR decrease for the sciatic nerve for both SMS protocols compared with standard T2 TSE (SMS-TSE FAST /SMS-TSE HR , -39%/-55%; P ≤ 0.01). Intrarater and interrater reliability of qualitative image review was good to excellent (κ: 0.672-0.971/0.617-0.883). Compared with the standard T2 TSE sequence, both SMS methods were shown to be superior in reducing pulsatile flow artifacts ( P < 0.01). Ratings for muscle border sharpness, detailed muscle structures, nerve border sharpness, and nerve fascicular structure did not differ significantly between the standard T2 TSE and the SMS-TSE FAST ( P > 0.05) and were significantly better for the SMS-TSE HR than for standard T2 TSE ( P < 0.001). Muscle signal homogeneity was mildly inferior for both SMS-TSE FAST ( P > 0.05) and SMS-TSE HR ( P < 0.001). A significantly higher number of T2 nerve lesions were detected by SMS-TSE HR ( P ≤ 0.01) compared with the standard T2 TSE and SMS-TSE FAST , whereas no significant difference was observed between the standard T2 TSE and SMS-TSE FAST . CONCLUSIONS Implementation of SMS offers either to substantially reduce acquisition time by over 40% without significantly impeding image quality compared with the standard T2 TSE or to increase in-plane resolution for a high-resolution approach and improved depiction of T2 nerve lesions while keeping acquisition times constant. This addresses the specific needs of MRN by providing different imaging approaches for 2D clinical MRN.
Collapse
Affiliation(s)
- Fabian Preisner
- From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg
| | - Jennifer C Hayes
- From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg
| | - Tobias Charlet
- From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg
| | | | - Thomas Hielscher
- Division of Biostatistics, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Daniel Schwarz
- From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg
| | - Dominik F Vollherbst
- From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg
| | - Michael O Breckwoldt
- From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg
| | - Jessica Jesser
- From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg
| | - Sabine Heiland
- From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg
| | - Martin Bendszus
- From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg
| | - Tim Hilgenfeld
- From the Department of Neuroradiology, Heidelberg University Hospital, Heidelberg
| |
Collapse
|
9
|
Baylosis BL, McQuiston AS, Bayne CO, Szabo RM, Boutin RD. Pre-operative imaging for surgical decision-making and the frequency of wrist arthrodesis and carpectomy procedures: a scoping review. Skeletal Radiol 2023; 52:143-150. [PMID: 35970955 DOI: 10.1007/s00256-022-04157-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 08/06/2022] [Accepted: 08/08/2022] [Indexed: 02/02/2023]
Abstract
OBJECTIVES Our objectives were to (1) analyze the imaging modalities utilized pre-operatively that influence surgical decision-making for wrist arthrodesis and carpectomy procedures and (2) determine the type and frequency of these procedures for the treatment of wrist arthritis. MATERIALS AND METHODS This review was performed according to the guidelines of PRISMA Extension for Scoping Reviews. Using PubMed, Embase, and Scopus, peer-reviewed literature from 2011 to 2022 was searched for use of imaging in pre-operative decision-making for wrist arthrodesis and carpectomy surgical procedures. Data were compiled to determine the type(s) of imaging modalities used pre-operatively and types of surgical techniques reported in the literature. RESULTS Of 307 articles identified, 35 articles satisfied eligibility criteria, with a total of 1377 patients (68% men; age mean, 50.9 years [range, 10-81]) and 1428 wrist surgical interventions. Radiography was reported for pre-operative planning in all articles for all patients. Pre-operative cross-sectional imaging was reported in 2 articles (5.7%), but no articles reported detailed data on how CT or MRI influenced pre-operative wrist arthrodesis and carpectomy procedure decision-making. A dozen different types of surgical techniques were reported. The four most common procedures were four-corner arthrodesis with scaphoid excision (846, 59%), proximal row carpectomy (239, 17%), total wrist arthrodesis (130, 9%), and scaphocapitate arthrodesis (53, 4%). CONCLUSION Radiography is always used in pre-operative decision-making, but the literature lacks data on the influence of CT and MRI for selecting among a dozen different types of wrist arthrodesis and carpectomy procedures.
Collapse
Affiliation(s)
- Barry L Baylosis
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA, 94305-5105, USA
| | - Alexander S McQuiston
- Stanford University School of Medicine, 3801 Miranda Ave. Bldg. 710, Palo Alto, CA, 94304, USA
| | - Christopher O Bayne
- Department of Orthopaedic Surgery, UC Davis School of Medicine, 4860 Y St, Ste 3800, Sacramento, CA, 95817, USA
| | - Robert M Szabo
- Department of Orthopaedic Surgery, UC Davis School of Medicine, 4860 Y St, Ste 3800, Sacramento, CA, 95817, USA
| | - Robert D Boutin
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA, 94305-5105, USA.
| |
Collapse
|
10
|
Gallo-Bernal S, Bedoya MA, Gee MS, Jaimes C. Pediatric magnetic resonance imaging: faster is better. Pediatr Radiol 2022:10.1007/s00247-022-05529-x. [PMID: 36261512 DOI: 10.1007/s00247-022-05529-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 08/29/2022] [Accepted: 10/03/2022] [Indexed: 10/24/2022]
Abstract
Magnetic resonance imaging (MRI) has emerged as the preferred imaging modality for evaluating a wide range of pediatric medical conditions. Nevertheless, the long acquisition times associated with this technique can limit its widespread use in young children, resulting in motion-degraded or non-diagnostic studies. As a result, sedation or general anesthesia is often necessary to obtain diagnostic images, which has implications for the safety profile of MRI, the cost of the exam and the radiology department's clinical workflow. Over the last decade, several techniques have been developed to increase the speed of MRI, including parallel imaging, single-shot acquisition, controlled aliasing techniques, compressed sensing and artificial-intelligence-based reconstructions. These are advantageous because shorter examinations decrease the need for sedation and the severity of motion artifacts, increase scanner throughput, and improve system efficiency. In this review we discuss a framework for image acceleration in children that includes the synergistic use of state-of-the-art MRI hardware and optimized pulse sequences. The discussion is framed within the context of pediatric radiology and incorporates the authors' experience in deploying these techniques in routine clinical practice.
Collapse
Affiliation(s)
- Sebastian Gallo-Bernal
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA.,Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - M Alejandra Bedoya
- Department of Radiology, Harvard Medical School, Boston, MA, USA.,Department of Radiology, Boston Children's Hospital, 300 Longwood Ave., 2nd floor, Main Building, Boston, MA, 02115, USA
| | - Michael S Gee
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA.,Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Camilo Jaimes
- Department of Radiology, Harvard Medical School, Boston, MA, USA. .,Department of Radiology, Boston Children's Hospital, 300 Longwood Ave., 2nd floor, Main Building, Boston, MA, 02115, USA.
| |
Collapse
|