1
|
Espinosa-Espejel KI, Rosales-Luengas Y, Salazar S, Lopéz-Gutiérrez R, Lozano R. Active Disturbance Rejection Control via Neural Networks for a Lower-Limb Exoskeleton. SENSORS (BASEL, SWITZERLAND) 2024; 24:6546. [PMID: 39460027 PMCID: PMC11511477 DOI: 10.3390/s24206546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 10/01/2024] [Accepted: 10/09/2024] [Indexed: 10/28/2024]
Abstract
This article presents the design of a control algorithm based on Artificial Neural Networks (ANNs) applied to a lower-limb exoskeleton, which is aimed to carry out walking trajectories during lower-limb rehabilitation. The interaction between the patient and the exoskeleton leads to model uncertainties and external disturbances that are always present. For this reason, the proposed control considers that the non-linear part of the model is unknown and is perturbed by external disturbances, which are estimated by an active disturbance rejection control via Artificial Neural Networks. To validate the proposed approach, a numerical simulation and an experimental implementation of the ANN-Controller are developed.
Collapse
Affiliation(s)
- Karina I. Espinosa-Espejel
- Department of Research and Multidisciplinary Studies, Center for Research and Advanced Studies of the National Polytechnic Institute, Mexico City 07360, Mexico; (K.I.E.-E.); (Y.R.-L.); (S.S.)
| | - Yukio Rosales-Luengas
- Department of Research and Multidisciplinary Studies, Center for Research and Advanced Studies of the National Polytechnic Institute, Mexico City 07360, Mexico; (K.I.E.-E.); (Y.R.-L.); (S.S.)
| | - Sergio Salazar
- Department of Research and Multidisciplinary Studies, Center for Research and Advanced Studies of the National Polytechnic Institute, Mexico City 07360, Mexico; (K.I.E.-E.); (Y.R.-L.); (S.S.)
| | | | - Rogelio Lozano
- Department of Research and Multidisciplinary Studies, Center for Research and Advanced Studies of the National Polytechnic Institute, Mexico City 07360, Mexico; (K.I.E.-E.); (Y.R.-L.); (S.S.)
| |
Collapse
|
2
|
Andrade RL, Figueiredo J, Fonseca P, Vilas-Boas JP, Silva MT, Santos CP. Human-Robot Joint Misalignment, Physical Interaction, and Gait Kinematic Assessment in Ankle-Foot Orthoses. SENSORS (BASEL, SWITZERLAND) 2023; 24:246. [PMID: 38203110 PMCID: PMC10781370 DOI: 10.3390/s24010246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 12/24/2023] [Accepted: 12/26/2023] [Indexed: 01/12/2024]
Abstract
Lower limb exoskeletons and orthoses have been increasingly used to assist the user during gait rehabilitation through torque transmission and motor stability. However, the physical human-robot interface (HRi) has not been properly addressed. Current orthoses lead to spurious forces at the HRi that cause adverse effects and high abandonment rates. This study aims to assess and compare, in a holistic approach, human-robot joint misalignment and gait kinematics in three fixation designs of ankle-foot orthoses (AFOs). These are AFOs with a frontal shin guard (F-AFO), lateral shin guard (L-AFO), and the ankle modulus of the H2 exoskeleton (H2-AFO). An experimental protocol was implemented to assess misalignment, fixation displacement, pressure interactions, user-perceived comfort, and gait kinematics during walking with the three AFOs. The F-AFO showed reduced vertical misalignment (peak of 1.37 ± 0.90 cm, p-value < 0.05), interactions (median pressures of 0.39-3.12 kPa), and higher user-perceived comfort (p-value < 0.05) when compared to H2-AFO (peak misalignment of 2.95 ± 0.64 and pressures ranging from 3.19 to 19.78 kPa). F-AFO also improves the L-AFO in pressure (median pressures ranging from 8.64 to 10.83 kPa) and comfort (p-value < 0.05). All AFOs significantly modified hip joint angle regarding control gait (p-value < 0.01), while the H2-AFO also affected knee joint angle (p-value < 0.01) and gait spatiotemporal parameters (p-value < 0.05). Overall, findings indicate that an AFO with a frontal shin guard and a sports shoe is effective at reducing misalignment and pressure at the HRI, increasing comfort with slight changes in gait kinematics.
Collapse
Affiliation(s)
- Ricardo Luís Andrade
- Center for MicroElectroMechanical Systems (CMEMS), University of Minho, 4800-058 Guimarães, Portugal
| | - Joana Figueiredo
- Center for MicroElectroMechanical Systems (CMEMS), University of Minho, 4800-058 Guimarães, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga/4800-058 Guimarães, Portugal
| | - Pedro Fonseca
- Porto Biomechanics Laboratory (LABIOMEP), University of Porto, 4200-450 Porto, Portugal; (P.F.); (J.P.V.-B.)
| | - João P. Vilas-Boas
- Porto Biomechanics Laboratory (LABIOMEP), University of Porto, 4200-450 Porto, Portugal; (P.F.); (J.P.V.-B.)
- Centre of Research, Education, Innovation and Intervention in Sport (CIFI2D), Faculty of Sport, University of Porto, 4200-450 Porto, Portugal
| | - Miguel T. Silva
- IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisbon, Portugal;
| | - Cristina P. Santos
- Center for MicroElectroMechanical Systems (CMEMS), University of Minho, 4800-058 Guimarães, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga/4800-058 Guimarães, Portugal
| |
Collapse
|
3
|
Zhou Y. Recent advances in wearable actuated ankle-foot orthoses: Medical effects, design, and control. Proc Inst Mech Eng H 2023; 237:163-178. [PMID: 36515408 DOI: 10.1177/09544119221142335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This paper presents a survey on recent advances of wearable actuated ankle-foot orthoses (AAFOs). First of all, their medical functions are investigated. From the short-term aspect, they lead to rectification of pathological gaits, reduction of metabolic cost, and improvement of gait performance. After AAFO-based walking training with sufficient time, free walking performance can be enhanced. Then, key design factors are studied. First, primary design parameters are investigated. Second, common actuators are analysed. Third, human-robot interaction (HRI), ergonomics, safety, and application places, are considered. In the following section, control technologies are reviewed from the aspects of rehabilitation stages, gait feature quantities, and controller characteristics. Finally, existing problems are discussed; development trends are prospected.
Collapse
Affiliation(s)
- Yuan Zhou
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| |
Collapse
|
4
|
Single Actuator with Versatile Controllability of 2-DOF Assistance for Exosuits via a Novel Moving-Gear Mechanism. ACTUATORS 2022. [DOI: 10.3390/act11050135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Decreasing the system weight while maintaining the assistance performance can help reduce the metabolic penalty in exosuits. Various researchers have proposed a bi-directional cable-driven actuator that can provide two degrees of freedom (2-DOF) assistance by using a single motor. However, such systems face limitations associated with the controllability of the assistance force. This study proposes a novel cable-driven system, that is, a dual pulley drive, that can provide versatile controllability of 2-DOF cable actuation by using a single motor via a novel moving gear mechanism. The moving gear winds the cable by switching both the side pulleys, which are then used for 2-DOF cable actuation. The spiral springs embedded between the pulley and base shaft work to release the cable. Results of experiments demonstrate that the dual pulley drive provides a versatile range of motion. The proposed system can provide 34.1% of overlapping motion per cable round trip time and support the non-overlapping motion. The preliminary integration of the dual pulley drive to the exosuit confirms that the novel exosuit is considerably lighter than the state-of-the-art exosuit. The calculations indicate that the operating cable speed and force generated using the proposed design are higher than the existing exosuit.
Collapse
|
5
|
Application of Wearable Sensors in Actuation and Control of Powered Ankle Exoskeletons: A Comprehensive Review. SENSORS 2022; 22:s22062244. [PMID: 35336413 PMCID: PMC8954890 DOI: 10.3390/s22062244] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 02/28/2022] [Accepted: 03/08/2022] [Indexed: 02/06/2023]
Abstract
Powered ankle exoskeletons (PAEs) are robotic devices developed for gait assistance, rehabilitation, and augmentation. To fulfil their purposes, PAEs vastly rely heavily on their sensor systems. Human–machine interface sensors collect the biomechanical signals from the human user to inform the higher level of the control hierarchy about the user’s locomotion intention and requirement, whereas machine–machine interface sensors monitor the output of the actuation unit to ensure precise tracking of the high-level control commands via the low-level control scheme. The current article aims to provide a comprehensive review of how wearable sensor technology has contributed to the actuation and control of the PAEs developed over the past two decades. The control schemes and actuation principles employed in the reviewed PAEs, as well as their interaction with the integrated sensor systems, are investigated in this review. Further, the role of wearable sensors in overcoming the main challenges in developing fully autonomous portable PAEs is discussed. Finally, a brief discussion on how the recent technology advancements in wearable sensors, including environment—machine interface sensors, could promote the future generation of fully autonomous portable PAEs is provided.
Collapse
|
6
|
Tiboni M, Borboni A, Vérité F, Bregoli C, Amici C. Sensors and Actuation Technologies in Exoskeletons: A Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:884. [PMID: 35161629 PMCID: PMC8839165 DOI: 10.3390/s22030884] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 01/16/2022] [Accepted: 01/19/2022] [Indexed: 02/06/2023]
Abstract
Exoskeletons are robots that closely interact with humans and that are increasingly used for different purposes, such as rehabilitation, assistance in the activities of daily living (ADLs), performance augmentation or as haptic devices. In the last few decades, the research activity on these robots has grown exponentially, and sensors and actuation technologies are two fundamental research themes for their development. In this review, an in-depth study of the works related to exoskeletons and specifically to these two main aspects is carried out. A preliminary phase investigates the temporal distribution of scientific publications to capture the interest in studying and developing novel ideas, methods or solutions for exoskeleton design, actuation and sensors. The distribution of the works is also analyzed with respect to the device purpose, body part to which the device is dedicated, operation mode and design methods. Subsequently, actuation and sensing solutions for the exoskeletons described by the studies in literature are analyzed in detail, highlighting the main trends in their development and spread. The results are presented with a schematic approach, and cross analyses among taxonomies are also proposed to emphasize emerging peculiarities.
Collapse
Affiliation(s)
- Monica Tiboni
- Department of Mechanical and Industrial Engineering, University of Brescia, Via Branze, 38, 25123 Brescia, Italy; (M.T.); (C.A.)
| | - Alberto Borboni
- Department of Mechanical and Industrial Engineering, University of Brescia, Via Branze, 38, 25123 Brescia, Italy; (M.T.); (C.A.)
| | - Fabien Vérité
- Agathe Group INSERM U 1150, UMR 7222 CNRS, ISIR (Institute of Intelligent Systems and Robotics), Sorbonne Université, 75005 Paris, France;
| | - Chiara Bregoli
- Institute of Condensed Matter Chemistry and Technologies for Energy (ICMATE), National Research Council (CNR), Via Previati 1/E, 23900 Lecco, Italy;
| | - Cinzia Amici
- Department of Mechanical and Industrial Engineering, University of Brescia, Via Branze, 38, 25123 Brescia, Italy; (M.T.); (C.A.)
| |
Collapse
|
7
|
Lee T, Kim I, Lee SH. Estimation of the Continuous Walking Angle of Knee and Ankle (Talocrural Joint, Subtalar Joint) of a Lower-Limb Exoskeleton Robot Using a Neural Network. SENSORS 2021; 21:s21082807. [PMID: 33923587 PMCID: PMC8072591 DOI: 10.3390/s21082807] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 04/09/2021] [Accepted: 04/15/2021] [Indexed: 11/16/2022]
Abstract
A lower-limb exoskeleton robot identifies the wearer's walking intention and assists the walking movement through mechanical force; thus, it is important to be able to identify the wearer's movement in real-time. Measurement of the angle of the knee and ankle can be difficult in the case of patients who cannot move the lower-limb joint properly. Therefore, in this study, the knee angle as well as the angles of the talocrural and subtalar joints of the ankle were estimated during walking by applying the neural network to two inertial measurement unit (IMU) sensors attached to the thigh and shank. First, for angle estimation, the gyroscope and accelerometer data of the IMU sensor were obtained while walking at a treadmill speed of 1 to 2.5 km/h while wearing an exoskeleton robot. The weights according to each walking speed were calculated using a neural network algorithm programmed in MATLAB software. Second, an appropriate weight was selected according to the walking speed through the IMU data, and the knee angle and the angles of the talocrural and subtalar joints of the ankle were estimated in real-time during walking through a feedforward neural network using the IMU data received in real-time. We confirmed that the angle estimation error was accurately estimated as 1.69° ± 1.43 (mean absolute error (MAE) ± standard deviation (SD)) for the knee joint, 1.29° ± 1.01 for the talocrural joint, and 0.82° ± 0.69 for the subtalar joint. Therefore, the proposed algorithm has potential for gait rehabilitation as it addresses the difficulty of estimating angles of lower extremity patients using torque and EMG sensors.
Collapse
|
8
|
Abstract
Electromagnetic actuator systems composed of an induction servo motor (ISM) drive system and a rice milling machine system have widely been used in agricultural applications. In order to achieve a finer control performance, a witty control system using a revised recurrent Jacobi polynomial neural network (RRJPNN) control and two remunerated controls with an altered bat search algorithm (ABSA) method is proposed to control electromagnetic actuator systems. The witty control system with finer learning capability can fulfill the RRJPNN control, which involves an attunement law, two remunerated controls, which have two evaluation laws, and a dominator control. Based on the Lyapunov stability principle, the attunement law in the RRJPNN control and two evaluation laws in the two remunerated controls are derived. Moreover, the ABSA method can acquire the adjustable learning rates to quicken convergence of weights. Finally, the proposed control method exhibits a finer control performance that is confirmed by experimental results.
Collapse
|