1
|
Hussain A, Gul H, Raza W, Qadir S, Rehan M, Raza N, Helal A, Shaikh MN, Aziz MA. Micro and Nanoporous Membrane Platforms for Carbon Neutrality: Membrane Gas Separation Prospects. CHEM REC 2024; 24:e202300352. [PMID: 38501854 DOI: 10.1002/tcr.202300352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 02/12/2024] [Indexed: 03/20/2024]
Abstract
Recently, carbon neutrality has been promoted as a potentially practical solution to global CO2 emissions and increasing energy-consumption challenges. Many attempts have been made to remove CO2 from the environment to address climate change and rising sea levels owing to anthropogenic CO2 emissions. Herein, membrane technology is proposed as a suitable solution for carbon neutrality. This review aims to comprehensively evaluate the currently available scientific research on membranes for carbon capture, focusing on innovative microporous material membranes used for CO2 separation and considering their material, chemical, and physical characteristics and permeability factors. Membranes from such materials comprise metal-organic frameworks, zeolites, silica, porous organic frameworks, and microporous polymers. The critical obstacles related to membrane design, growth, and CO2 capture and usage processes are summarized to establish novel membranes and strategies and accelerate their scaleup.
Collapse
Affiliation(s)
- Arshad Hussain
- Interdisciplinary Research Center for Hydrogen Technologies and Carbon Management (IRC-HTCM), King Fahd University of Petroleum & Minerals, KFUPM Box 5040, 31261, Dhahran, Saudi Arabia
| | - Hajera Gul
- Department of Chemistry, Shaheed Benazir Bhutto Women University, 25000, Peshawar, Pakistan
| | - Waseem Raza
- Institute for Advanced Study, Shenzhen University, 518060, Guangdong, China
- College of Civil and Transportation Engineering, Shenzhen University, 518060, Shenzhen, Guangdong, China
| | - Salman Qadir
- Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 116023, Dalian, PR China
| | - Muhammad Rehan
- Department of Chemical Engineering, Beijing Institute of Technology, 100000, Beijing, China
| | - Nadeem Raza
- College of Science, Chemistry Department, Imam Mohammad Ibn Saud Islamic University (IMSIU), 11623, Riyadh, Kingdom of Saudi Arabia
| | - Aasif Helal
- Interdisciplinary Research Center for Hydrogen Technologies and Carbon Management (IRC-HTCM), King Fahd University of Petroleum & Minerals, KFUPM Box 5040, 31261, Dhahran, Saudi Arabia
| | - M Nasiruzzaman Shaikh
- Interdisciplinary Research Center for Hydrogen Technologies and Carbon Management (IRC-HTCM), King Fahd University of Petroleum & Minerals, KFUPM Box 5040, 31261, Dhahran, Saudi Arabia
| | - Md Abdul Aziz
- Interdisciplinary Research Center for Hydrogen Technologies and Carbon Management (IRC-HTCM), King Fahd University of Petroleum & Minerals, KFUPM Box 5040, 31261, Dhahran, Saudi Arabia
| |
Collapse
|
2
|
Recent Advances in Poly(Ionic Liquid)-Based Membranes for CO 2 Separation. Polymers (Basel) 2023; 15:polym15030667. [PMID: 36771968 PMCID: PMC9920068 DOI: 10.3390/polym15030667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 12/13/2022] [Accepted: 01/26/2023] [Indexed: 02/01/2023] Open
Abstract
Poly(ionic liquid)-based membranes have been the subject of intensive research in the last 15 years due to their potential for the separation of CO2 from other gases. In this short review, different types of PIL-based membranes for CO2 separation are described (neat PIL membranes; PIL-IL composite membranes; PIL-polymer blend membranes; PIL-based block copolymer membranes, and PIL-based mixed matrix membranes), and their state-of-the-art separation results for different gas pairs (CO2/N2, CO2/H2, and CO2/CH4) are presented and discussed. This review article is focused on the most relevant research works performed over the last 5 years, that is, since the year 2017 onwards, in the field of poly(ionic liquid)-based membranes for CO2 separation. The micro- and nano-morphological characterization of the membranes is highlighted as a research topic that requires deeper study and understanding. Nowadays there is an array of advanced structural characterization techniques, such as neutron scattering techniques with contrast variation (using selective deuteration), that can be used to probe the micro- and nanostructure of membranes, in length scales ranging from ~1 nm to ~15 μm. Although some of these techniques have been used to study the morphology of PIL-based membranes for electrochemical applications, their use in the study of PIL-based membranes for CO2 separation is still unknown.
Collapse
|
3
|
Recent advances in Poly(ionic liquids) membranes for CO2 separation. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.121784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
4
|
Off-Design Operation of Conventional and Phase-Change CO2 Capture Solvents and Mixtures: A Systematic Assessment Approach. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10155316] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Solvent-based CO2 capture technologies hold promise for future implementation but conventional solvents incur significant energy penalties and capture costs. Phase-change solvents enable a significant reduction in the regeneration energy but their performance has only been investigated under steady-state operation. In the current work, we employed a systematic approach for the evaluation of conventional solvents and mixtures, as well as phase-change solvents under the influence of disturbances. Sensitivity analysis was used to identify the impact that operating parameter variations and different solvents exert on multiple CO2 capture performance indicators within a wide operating range. The resulting capture process performance was then assessed for each solvent within a multi-criteria approach, which simultaneously accounted for off-design conditions and nominal operation. The considered performance criteria included the regeneration energy, solvent mass flow rate, cost and cyclic capacity, net energy penalty from integration with an upstream power plant, and lost revenue from parasitic losses. The 10 investigated solvents included the phase-change solvents methyl-cyclohexylamine (MCA) and 2-(diethylamino)ethanol/3-(methylamino)propylamine (DEEA/MAPA). We found that the conventional mixture diethanolamine/methyldiethanolamine (DEA/MDEA) and the phase-change solvent DEEA/MAPA exhibited both resilience to disturbances and desirable nominal operation for multiple performance indicators simultaneously.
Collapse
|