1
|
Klüpfel J, Paßreiter S, Weidlein N, Knopp M, Ungerer M, Protzer U, Knolle P, Hayden O, Elsner M, Seidel M. Fully Automated Chemiluminescence Microarray Analysis Platform for Rapid and Multiplexed SARS-CoV-2 Serodiagnostics. Anal Chem 2022; 94:2855-2864. [PMID: 35107016 DOI: 10.1021/acs.analchem.1c04672] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Lateral-flow immunoassays and laboratory diagnostic tests like enzyme-linked immunosorbent assays (ELISAs) are powerful diagnostic tools to help fight the COVID-19 pandemic using them as antigen or antibody tests. However, the need emerges for alternative bioanalytical systems that combine their favorable features─simple, rapid, and cost-efficient point-of-care (POC) analysis of lateral-flow immunoassays and higher reliability of laboratory tests─while eliminating their disadvantages (limited sensitivity and specificity of lateral-flow assays and prolonged time and work expenditure of laboratory analysis). An additional need met by only a few tests is multiplexing, allowing for the analysis of several immunorecognition patterns at the same time. We herein present a strategy to combine all desirable attributes of the different test types by means of a flow-based chemiluminescence microarray immunoassay. Laminated polycarbonate microarray chips were developed for easy production and subsequent application in the fully automated microarray analysis platform MCR-R, where a novel flow cell design minimizes the sample volume to 40 μL. This system was capable of detecting IgG antibodies to SARS-CoV-2 with 100% sensitivity and specificity using recombinant antigens for the SARS-CoV-2 spike S1 protein, nucleocapsid protein, and receptor binding domain. The analysis was accomplished within under 4 min from serum, plasma, and whole blood, making it also useful in POC settings. Additionally, we showed the possibility of serosurveillance after infection or vaccination to monitor formerly unnoticed breakthrough infections in the population as well as to detect the need for booster vaccination after the natural decline of the antibody titer below detectable levels. This will help in answering pressing questions on the importance of the antibody response to SARS-CoV-2 that so far remain open. Additionally, even the sequential detection of IgM and IgG antibodies was possible, allowing for statements on the time response of an infection. While our serodiagnostic application focuses on SARS-CoV-2, the same approach is easily adjusted to other diseases, making it a powerful tool for future serological testing.
Collapse
Affiliation(s)
- Julia Klüpfel
- Institute of Hydrochemistry, Chair of Analytical Chemistry and Water Chemistry, Technical University of Munich, Lichtenbergstraße 4, 85748 Garching, Germany
| | - Sandra Paßreiter
- Institute of Hydrochemistry, Chair of Analytical Chemistry and Water Chemistry, Technical University of Munich, Lichtenbergstraße 4, 85748 Garching, Germany
| | - Nina Weidlein
- Institute of Hydrochemistry, Chair of Analytical Chemistry and Water Chemistry, Technical University of Munich, Lichtenbergstraße 4, 85748 Garching, Germany
| | - Martin Knopp
- Heinz-Nixdorf-Chair for Biomedical Electronics, Technical University of Munich, TranslaTUM, Einsteinstr. 25, 81675 München, Germany
| | - Martin Ungerer
- ISAR Bioscience GmbH, Semmelweisstr. 5, 82152 Planegg, Germany
| | - Ulrike Protzer
- Institute of Virology, Technical University of Munich/Helmholtz Zentrum München, Trogerstr. 30, 81675 München, Germany.,German Center for Infection Research (DZIF), Munich partner site, 81675 München, Germany
| | - Percy Knolle
- Institute of Molecular Immunology/Experimental Oncology, Technical University of Munich, Ismaningerstr. 22, 81675 München, Germany
| | - Oliver Hayden
- Heinz-Nixdorf-Chair for Biomedical Electronics, Technical University of Munich, TranslaTUM, Einsteinstr. 25, 81675 München, Germany
| | - Martin Elsner
- Institute of Hydrochemistry, Chair of Analytical Chemistry and Water Chemistry, Technical University of Munich, Lichtenbergstraße 4, 85748 Garching, Germany
| | - Michael Seidel
- Institute of Hydrochemistry, Chair of Analytical Chemistry and Water Chemistry, Technical University of Munich, Lichtenbergstraße 4, 85748 Garching, Germany
| |
Collapse
|
2
|
Jin X, Zhang H, Ni B, Liu W, Hou L, Marsh JH, Ye S, Sun X, Li X, Li S, Dong L, Hou JJ, Sun M, Xu B, Xiong J, Liu X. Label-free sensing of virus-like particles below the sub-diffraction limit by wide-field photon state parametric imaging of a gold nanodot array. NANOSCALE ADVANCES 2021; 3:6882-6887. [PMID: 36132363 PMCID: PMC9419464 DOI: 10.1039/d1na00603g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 10/18/2021] [Indexed: 06/15/2023]
Abstract
A parallel four-quadrant sensing method utilizing a specially designed gold nanodot array is created for sensing virus-like particles with a sub-diffraction limit size (∼100 nm) in a wide-field image. Direct label-free sensing of viruses using multiple four-quadrant sensing channels in parallel in a wide-field view enables the possibility of high-throughput onsite screening of viruses.
Collapse
Affiliation(s)
- Xiao Jin
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology Nanjing 210094 P. R. China
| | - Heng Zhang
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology Nanjing 210094 P. R. China
| | - Bin Ni
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology Nanjing 210094 P. R. China
| | - Weiping Liu
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology Nanjing 210094 P. R. China
| | - Lianping Hou
- James Watt School of Engineering, University of Glasgow Glasgow G12 8QQ UK
| | - John H Marsh
- James Watt School of Engineering, University of Glasgow Glasgow G12 8QQ UK
| | - Shengwei Ye
- James Watt School of Engineering, University of Glasgow Glasgow G12 8QQ UK
| | - Xiao Sun
- James Watt School of Engineering, University of Glasgow Glasgow G12 8QQ UK
| | - Xiaofeng Li
- State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Disease, The first affiliated Hospital of Guangzhou Medical University Guangzhou 510182 P. R. China
| | - Shanhu Li
- Department of Cell Engineering, Beijing Institute of Biotechnology Beijing 100850 P. R. China
| | - Lei Dong
- School of Life Science, Beijing Institute of Technology Beijing 100081 P. R. China
| | - Jamie Jiangmin Hou
- The Royal College of Surgeons of Edinburgh Nicolson Street Edinburgh Scotland EH8 9DW UK
| | - Ming Sun
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology Nanjing 210094 P. R. China
| | - Bin Xu
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology Nanjing 210094 P. R. China
| | - Jichuan Xiong
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology Nanjing 210094 P. R. China
| | - Xuefeng Liu
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology Nanjing 210094 P. R. China
| |
Collapse
|
3
|
A R, Wang H, Wang W, Tan W. Summary of the Detection Kits for SARS-CoV-2 Approved by the National Medical Products Administration of China and Their Application for Diagnosis of COVID-19. Virol Sin 2020; 35:699-712. [PMID: 33351166 PMCID: PMC7754703 DOI: 10.1007/s12250-020-00331-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Accepted: 11/25/2020] [Indexed: 12/15/2022] Open
Abstract
The on-going global pandemic of coronavirus disease 2019 (COVID-19) caused by a novel coronavirus called severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been underway for about 11 months. Through November 20, 2020, 51 detection kits for SARS-CoV-2 nucleic acids (24 kits), antibodies (25 kits), or antigens (2 kits) have been approved by the National Medical Products Administration of China (NMPA). Convenient and reliable SARS-CoV-2 detection assays are urgently needed worldwide for strategic control of the pandemic. In this review, the detection kits approved in China are summarised and the three types of tests, namely nucleic acid, serological and antigen detection, which are available for the detection of COVID-19 are discussed in detail. The development of novel detection kits will lay the foundation for the control and prevention of the COVID-19 pandemic globally.
Collapse
Affiliation(s)
- Ruhan A
- NHC Key Laboratory of Biosafety, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, 102206, China
| | - Huijuan Wang
- NHC Key Laboratory of Biosafety, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, 102206, China
| | - Wenling Wang
- NHC Key Laboratory of Biosafety, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, 102206, China.
| | - Wenjie Tan
- NHC Key Laboratory of Biosafety, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, 102206, China.
| |
Collapse
|