1
|
Solou K, Solou AV, Tatani I, Lakoumentas J, Tserpes K, Megas P. Increased stability of short femoral stem through customized distribution of coefficient of friction in porous coating. Sci Rep 2024; 14:12243. [PMID: 38806607 PMCID: PMC11133419 DOI: 10.1038/s41598-024-63077-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 05/24/2024] [Indexed: 05/30/2024] Open
Abstract
Stress shielding and aseptic loosening are complications of short stem total hip arthroplasty, which may lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective in reducing stress shielding, however, there is a lack of research on optimized porous distribution in stem's coating. This study aimed to optimize the distribution of the coefficient of friction of a metaphyseal femoral stem, aiming for reducing stress shielding in the proximal area. A finite element analysis model of an implanted, titanium alloy short-tapered wedge stem featuring a porous coating made of titanium was designed to simulate a static structural analysis of the femoral stem's behavior under axial loading in Analysis System Mechanical Software. For computational feasibility, 500 combinations of coefficients of friction were randomly sampled. Increased strains in proximal femur were found in 8.4% of the models, which had decreased coefficients of friction in middle medial areas of porous coating and increased in lateral proximal and lateral and medial distal areas. This study reported the importance of the interface between bone and middle medial and distal lateral areas of the porous coating in influencing the biomechanical behavior of the proximal femur, and potentially reducing stress shielding.
Collapse
Affiliation(s)
- Konstantina Solou
- Department of Orthopaedic Surgery and Traumatology, School of Medicine, University of Patras, Patras, Greece.
| | - Anna Vasiliki Solou
- Department of Mechanical Engineering & Aeronautics, University of Patras, Patras, Greece
| | - Irini Tatani
- Department of Orthopaedic Surgery and Traumatology, School of Medicine, University of Patras, Patras, Greece
| | - John Lakoumentas
- Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece
| | - Konstantinos Tserpes
- Department of Mechanical Engineering & Aeronautics, University of Patras, Patras, Greece
| | - Panagiotis Megas
- Department of Orthopaedic Surgery and Traumatology, School of Medicine, University of Patras, Patras, Greece
| |
Collapse
|
2
|
Liu H, Chen H, Han Q, Sun B, Liu Y, Zhang A, Fan D, Xia P, Wang J. Recent advancement in vascularized tissue-engineered bone based on materials design and modification. Mater Today Bio 2023; 23:100858. [PMID: 38024843 PMCID: PMC10679779 DOI: 10.1016/j.mtbio.2023.100858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 09/03/2023] [Accepted: 11/06/2023] [Indexed: 12/01/2023] Open
Abstract
Bone is one of the most vascular network-rich tissues in the body and the vascular system is essential for the development, homeostasis, and regeneration of bone. When segmental irreversible damage occurs to the bone, restoring its vascular system by means other than autogenous bone grafts with vascular pedicles is a therapeutic challenge. By pre-generating the vascular network of the scaffold in vivo or in vitro, the pre-vascularization technique enables an abundant blood supply in the scaffold after implantation. However, pre-vascularization techniques are time-consuming, and in vivo pre-vascularization techniques can be damaging to the body. Critical bone deficiencies may be filled quickly with immediate implantation of a supporting bone tissue engineered scaffold. However, bone tissue engineered scaffolds generally lack vascularization, which requires modification of the scaffold to aid in enhancing internal vascularization. In this review, we summarize the relationship between the vascular system and osteogenesis and use it as a basis to further discuss surgical and cytotechnology-based pre-vascularization strategies and to describe the preparation of vascularized bone tissue engineered scaffolds that can be implanted immediately. We anticipate that this study will serve as inspiration for future vascularized bone tissue engineered scaffold construction and will aid in the achievement of clinical vascularized bone.
Collapse
Affiliation(s)
- Hao Liu
- Department of Orthopedic Surgery, The Second Hospital of Jilin University, Changchun 130000, Jilin, China
| | - Hao Chen
- Department of Orthopedic Surgery, The Second Hospital of Jilin University, Changchun 130000, Jilin, China
| | - Qin Han
- Department of Orthopedic Surgery, The Second Hospital of Jilin University, Changchun 130000, Jilin, China
| | - Bin Sun
- Department of Orthopedic Surgery, The Second Hospital of Jilin University, Changchun 130000, Jilin, China
| | - Yang Liu
- Department of Orthopedic Surgery, The Second Hospital of Jilin University, Changchun 130000, Jilin, China
| | - Aobo Zhang
- Department of Orthopedic Surgery, The Second Hospital of Jilin University, Changchun 130000, Jilin, China
| | - Danyang Fan
- Department of Dermatology, The Second Hospital of Jilin University, Changchun 130000, Jilin, China
| | - Peng Xia
- Department of Orthopedic Surgery, The Second Hospital of Jilin University, Changchun 130000, Jilin, China
| | - Jincheng Wang
- Department of Orthopedic Surgery, The Second Hospital of Jilin University, Changchun 130000, Jilin, China
| |
Collapse
|
3
|
Puškár M, Živčák J, Kopas M, Tarbajovský P, Lavčák M. Complex Analysis of Power Output and Emission Parameters of High-Power Motorcycles at Application of Advanced and Sustainable Fuels and Their Mixtures. ACS OMEGA 2023; 8:7085-7092. [PMID: 36844597 PMCID: PMC9947973 DOI: 10.1021/acsomega.2c07984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 01/23/2023] [Indexed: 06/18/2023]
Abstract
The presented scientific study is focused on a complex analysis of power output and emission parameters concerning an experimental motorcycle. In spite of the fact that there are at disposal considerable theoretical and experimental results, which include also matters of the L-category vehicles, there is, in general, a lack of data covering the experimental tests and power output characteristics of racing, high-power engines that represent a technological peak in the given segment. This situation is caused by an aversion of motorcycle producers to publicize their newest information, especially in the case of the latest high-tech applications. The given study is focused on all the main results obtained from the operational tests performed on the motorcycle engine in two testing cases: first with the original arrangement of the installed piston combustion engine series produced and second with the modified engine configuration proposed in order to increase the combustion process efficiency. Three kinds of engine fuel were tested and mutually compared within the performed research work: the first was the experimental top fuel used in the world motorcycle competition 4SGP, the second was the sustainable experimental fuel, the so-called superethanol e85 developed for maximum power output and minimum emission, and the third was the standard fuel, which is commonly available at gas stations. Applicable fuel mixtures were also created with the aim to analyze their power output and emission parameters. Finally, these fuel mixtures were compared with the top technological products available in the given area.
Collapse
|
4
|
Kulcsár K, Buzgo M, Costa PF, Zsoldos I. Optimal microstructure and mechanical properties of open-cell porous titanium structures produced by selective laser melting. Front Bioeng Biotechnol 2022; 10:1022310. [PMID: 36267452 PMCID: PMC9578010 DOI: 10.3389/fbioe.2022.1022310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Accepted: 09/05/2022] [Indexed: 12/04/2022] Open
Abstract
Three-dimensional printing technology enables the production of open cell porous structures. This has advantages but not only in terms of weight reduction. In implant structures, the process of osseointegration is improved, mechanical integration is better, the open cell porous structures resemble a trabecular structure that mimics bone tissue. In this work, we investigated titanium structures made porous by cutting spheres. Based on the patterns of different types of crystal models we created porosity with different strategies. We have shown that there are significant differences in mechanical properties between the porous structures formed with different strategies. We determined the structure that loses the least load-bearing capacity compared to the solid structure, with the same porosity levels and mechanical stresses. We characterized the possibility location and environment of becoming an open cell structure. We performed the calculations with mechanical simulations, which were validated experimentally. The quality of the three-dimensional printing of samples was checked by computed tomography reconstruction analysis.
Collapse
Affiliation(s)
- Klaudia Kulcsár
- Department of Materials Science and Technology, Szechenyi Istvan University, Gyor, Hungary
- Dent-Art Teknik Ltd., Gyor, Hungary
| | | | | | - Ibolya Zsoldos
- Department of Materials Science and Technology, Szechenyi Istvan University, Gyor, Hungary
- *Correspondence: Ibolya Zsoldos,
| |
Collapse
|
5
|
Surface Roughness Improvement by Sliding Friction Burnishing of Parts Produced by Selective Laser Melting of Ti6Al4V Titanium Alloy. MACHINES 2022. [DOI: 10.3390/machines10050400] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Selective laser melting is a frequently used, powder bed fusion additive manufacturing technology for producing metallic parts. However, appropriate surface quality cannot be achieved, so post-processing is often necessary. Subsequent machining of surfaces serves multiple objectives such as improvement of dimensional accuracy, changing surface roughness and modification of the residual stress state for higher surface hardness. Beyond its several advantageous properties, Ti6Al4V material has, as its weaknesses, low tribological behavior and wear resistance. Sliding friction burnishing is a conventional chipless and coolant-free environmentally conscious technology for surface modification that is appropriate for simultaneously decreasing surface roughness and increasing surface hardness. Until now, there has been a research gap regarding the diamond burnishing of selective laser melted Ti6Al4V parts. In this study, we investigated how the surface roughness of selective laser melted parts can be modified via sliding friction burnishing. 2D and 3D characteristics of surface roughness were measured by a chromatic roughness measuring device. Indices of surface roughness improvement were defined and studied as a function of selective laser melting parameters. Optimal manufacturing parameters of laser power—P = 280 W and scanning speed u = 1200 mm/s—for effective surface improvement via burnishing are proposed.
Collapse
|
6
|
Abstract
Ti-6Al-4V (Ti64) alloy is one of the most widely used orthopedic implant materials due to its mechanical properties, corrosion resistance, and biocompatibility nature. Porous Ti64 structures are gaining more research interest as bone implants as they can help in reducing the stress-shielding effect when compared to their solid counterpart. The literature shows that porous Ti64 implants fabricated using different additive manufacturing (AM) process routes, such as laser powder bed fusion (L-PBF) and electron beam melting (EBM) can be tailored to mimic the mechanical properties of natural bone. This review paper categorizes porous implant designs into non-gradient (uniform) and gradient (non-uniform) porous structures. Gradient porous design appears to be more promising for orthopedic applications due to its closeness towards natural bone morphology and improved mechanical properties. In addition, this paper outlines the details on bone structure and its properties, mechanical properties, fatigue behavior, multifunctional porous implant designs, current challenges, and literature gaps in the research studies on porous Ti64 bone implants.
Collapse
|
7
|
Static and Fatigue Load Bearing Investigation on Porous Structure Titanium Additively Manufactured Anterior Cervical Cages. BIOMED RESEARCH INTERNATIONAL 2022; 2022:6534749. [PMID: 35355825 PMCID: PMC8959973 DOI: 10.1155/2022/6534749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 02/21/2022] [Indexed: 11/24/2022]
Abstract
This study investigates the static and fatigue behavior of porous and conventional anterior cervical cages. Porous structure titanium anterior cervical cages were manufactured using direct selective laser sintering technique. Four different types of cervical cages were designed and manufactured, among which three designs consist of porous structure (type 1, type 2, and type 3) and manufactured using metal 3D printing. Remaining one design (type 4) was manufactured using conventional machining and did not consist any porous structure. All types of manufactured cages were tested in compression under static and fatigue loading conditions as per ASTM F2077 standard. Static and fatigue subsidence testing was performed using ASTM F2267 standard. Static compression testing results of type 1 and type 4 cages reported higher yield load when compared to the type 2 and type 3 cages. Static subsidence testing results reported almost 11% less subsidence rate for additively manufactured cages than the conventional cages. Fatigue subsidence testing results showed that type 2 and type 3 cages can withstood approximately 21% higher number of cycles before subsidence as compare to the type 1 and type 4 cages. During fatigue testing, all the cages design survived 5 million cycles at the 3000 N loading. For 6000 N and 8000 N, loading rate type 2 and type 3 cages showed lower fatigue life when compared to other cages design. Since fatigue life of type 2 and type 3 cage designs were reported lower than other cages design, it is concluded that the performance of the additively manufactured porous cages can be significantly varied based upon the cage design features.
Collapse
|
8
|
Three-Dimensional Modeling and 3D Printing of Biocompatible Orthodontic Power-Arm Design with Clinical Application. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11209693] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Three-dimensional (3D) printing with biocompatible resins offers new competition to its opposition—subtractive manufacturing, which currently dominates in dentistry. Removing dental material layer-by-layer with lathes, mills or grinders faces its limits when it comes to the fabrication of detailed complex structures. The aim of this original research was to design, materialize and clinically evaluate a functional and resilient shape of the orthodontic power-arm by means of biocompatible 3D printing. To improve power-arm resiliency, we have employed finite element modelling and analyzed stress distribution to improve the original design of the power-arm. After 3D printing, we have also evaluated both designs clinically. This multidisciplinary approach is described in this paper as a feasible workflow that might inspire application other individualized biomechanical appliances in orthodontics. The design is a biocompatible power-arm, a miniature device bonded to a tooth surface, translating significant bio-mechanical force vectors to move a tooth in the bone. Its design must be also resilient and fully individualized to patient oral anatomy. Clinical evaluation of the debonding rate in 50 randomized clinical applications for each power-arm-variant showed significantly less debonding incidents in the improved power-arm design (two failures = 4%) than in the original variant (nine failures = 18%).
Collapse
|