1
|
Moghtaderi S, Mandapati A, Davies G, Wahid KA, Lukong KE. Smart and low-cost fluorometer for identifying breast cancer malignancy based on lipid droplets accumulation. PLoS One 2023; 18:e0294988. [PMID: 38128020 PMCID: PMC10735024 DOI: 10.1371/journal.pone.0294988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 11/14/2023] [Indexed: 12/23/2023] Open
Abstract
The most common cause of breast cancer-related death is tumor recurrence. To develop more effective treatments, the identification of cancer cell specific malignancy indicators is therefore critical. Lipid droplets are known as an emerging hallmark in aggressive breast tumors. A common technique that can be used for observing molecules in cancer microenvironment is fluorescence microscopy. We describe the design, development and applicability of a smart fluorometer to detect lipid droplet accumulation based on the emitted fluorescence signals from highly malignant (MDA-MB-231) and mildly malignant (MCF7) breast cancer cell lines, that are stained with BODIPY dye. This device uses a visible-range light source as an excitation source and a spectral sensor as the detector. A commercial imaging system was used to examine the fluorescent cancer cell lines before being validated in a preclinical setting with the developed prototype. The outcomes indicate that this low-cost fluorometer can effectively detect the alterations levels of lipid droplets and hence distinguish between "moderately malignant" and "highly malignant" cancer cells. In comparison to prior research that used fluorescence spectroscopy techniques to detect cancer biomarkers, this study revealed enhanced capability in classifying mildly and highly malignant cancer cell lines.
Collapse
Affiliation(s)
- Shiva Moghtaderi
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Aditya Mandapati
- Department of Biochemistry, Microbiology and Immunology, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Gerald Davies
- Department of Biochemistry, Microbiology and Immunology, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Khan A. Wahid
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Kiven Erique Lukong
- Department of Biochemistry, Microbiology and Immunology, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| |
Collapse
|
2
|
Lai WQ, Chang YF, Chou FN, Yang DM. Portable FRET-Based Biosensor Device for On-Site Lead Detection. BIOSENSORS 2022; 12:bios12030157. [PMID: 35323427 PMCID: PMC8946079 DOI: 10.3390/bios12030157] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 02/24/2022] [Accepted: 02/28/2022] [Indexed: 05/31/2023]
Abstract
Most methods for measuring environmental lead (Pb) content are time consuming, expensive, hazardous, and restricted to specific analytical systems. To provide a facile, safe tool to detect Pb, we created pMet-lead, a portable fluorescence resonance energy transfer (FRET)-based Pb-biosensor. The pMet-lead device comprises a 3D-printed frame housing a 405-nm laser diode-an excitation source for fluorescence emission images (YFP and CFP)-accompanied by optical filters, a customized sample holder with a Met-lead 1.44 M1 (the most recent version)-embedded biochip, and an optical lens aligned for smartphone compatibility. Measuring the emission ratios (Y/C) of the FRET components enabled Pb detection with a dynamic range of nearly 2 (1.96), a pMet-lead/Pb dissociation constant (Kd) 45.62 nM, and a limit of detection 24 nM (0.474 μg/dL, 4.74 ppb). To mitigate earlier problems with a lack of selectivity for Pb vs. zinc, we preincubated samples with tricine, a low-affinity zinc chelator. We validated the pMet-lead measurements of the characterized laboratory samples and unknown samples from six regions in Taiwan by inductively coupled plasma mass spectrometry (ICP-MS). Notably, two unknown samples had Y/C ratios significantly higher than that of the control (3.48 ± 0.08 and 3.74 ± 0.12 vs. 2.79 ± 0.02), along with Pb concentrations (10.6 ppb and 15.24 ppb) above the WHO-permitted level of 10 ppb in tap water, while the remaining four unknowns showed no detectable Pb upon ICP-MS. These results demonstrate that pMet-lead provides a rapid, sensitive means for on-site Pb detection in water from the environment and in living/drinking supply systems to prevent potential Pb poisoning.
Collapse
Affiliation(s)
- Wei-Qun Lai
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei 11217, Taiwan; (W.-Q.L.); (F.-N.C.)
- Institute of Biophotonics, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan
| | - Yu-Fen Chang
- LumiSTAR Biotechnology, Inc., Taipei City 115, Taiwan;
| | - Fang-Ning Chou
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei 11217, Taiwan; (W.-Q.L.); (F.-N.C.)
| | - De-Ming Yang
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei 11217, Taiwan; (W.-Q.L.); (F.-N.C.)
- Institute of Biophotonics, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan
| |
Collapse
|
3
|
Chang TJ, Lai WQ, Chang YF, Wang CL, Yang DM. Development and optimization of heavy metal lead biosensors in biomedical and environmental applications. J Chin Med Assoc 2021; 84:745-753. [PMID: 34225337 DOI: 10.1097/jcma.0000000000000574] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
The detrimental impact of the heavy metal lead (Pb) on human health has been studied for years. The fact that Pb impairs human body has been established from countless painful and sad historical events. Nowadays, World Health Organization and many developmental countries have established regulations concerning the use of Pb. Measuring the blood lead level (BLL) is so far the only way to officially evaluate the degree of Pb exposure, but the so-called safety value (10 μg/dL in adults and 5 μg/dL in children) seems unreliable to represent the security checkpoint for children through daily intake of drinking water or physical contact with a lower contaminated level of Pb contents. In general, unsolved mysteries about the Pb toxicological mechanisms still remain. In this review article, we report on the methods to prevent Pb poison for further Pb toxicological research. We establish high-sensitivity Pb monitoring, and also report on the use of fluorescent biosensors such as genetically-encoded fluorescence resonance energy transfer-based biosensors built for various large demands such as the detection of severe acute respiratory syndrome coronavirus 2. We also contribute to the development and optimization of the FRET-based Pb biosensors. Our well-performed version of Met-lead 1.44 M1 has achieved a limit of detection of 10 nM (2 ppb; 0.2 μg/dL) and almost 5-fold in dynamic range (DR) supported for the real practical applications-that is, the in-cell Pb sensing device for blood and blood-related samples, and the Pb environmental detections in vitro. The perspective of our powerful Pb biosensor incorporated with a highly sensitive bio-chip of the portable device for quick Pb measurements will be addressed for further manipulation.
Collapse
Affiliation(s)
- Tai-Jay Chang
- Laboratory of Genome Research, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
- School of Biomedical science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
| | - Wei-Qun Lai
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
- Institute of Biophotonics, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
| | - Yu-Fen Chang
- LumiSTAR Biotechnology, Inc., Taipei, Taiwan, ROC
| | - Chia-Lin Wang
- Laboratory of Genome Research, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
- School of Biomedical science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
| | - De-Ming Yang
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
- Institute of Biophotonics, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
| |
Collapse
|
4
|
Mfouo-Tynga IS, Dias LD, Inada NM, Kurachi C. Features of third generation photosensitizers used in anticancer photodynamic therapy: Review. Photodiagnosis Photodyn Ther 2021; 34:102091. [PMID: 33453423 DOI: 10.1016/j.pdpdt.2020.102091] [Citation(s) in RCA: 109] [Impact Index Per Article: 27.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 10/08/2020] [Accepted: 10/30/2020] [Indexed: 01/02/2023]
Abstract
Cancer remains a main public health issue and the second cause of mortality worldwide. Photodynamic therapy is a clinically approved therapeutic option. Effective photodynamic therapy induces cancer damage and death through a multifactorial manner including reactive oxygen species-mediated damage and killing, vasculature damage, and immune defense activation. Anticancer efficiency depends on the improvement of photosensitizers drugs used in photodynamic therapy, their selectivity, enhanced photoproduction of reactive species, absorption at near-infrared spectrum, and drug-delivery strategies. Both experimental and clinical studies using first- and second-generation photosensitizers had pointed out the need for developing improved photosensitizers for photodynamic applications and achieving better therapeutic outcomes. Bioconjugation and encapsulation with targeting moieties appear as a main strategies for the development of photosensitizers from their precursors. Factors influencing cellular biodistribution and uptake are briefly discussed, as well as their roles as cancer diagnostic and therapeutic (theranostics) agents. The two-photon photodynamic approach using third-generation photosensitizers is present as an attempt in treating deeper tumors. Although significant advances had been made over the last decade, the development of next-generation photosensitizers is still mainly in the developmental stage.
Collapse
Affiliation(s)
- Ivan S Mfouo-Tynga
- São Carlos Institute of Physics, University of São Paulo, 13566-590, São Carlos, Brazil.
| | - Lucas D Dias
- São Carlos Institute of Physics, University of São Paulo, 13566-590, São Carlos, Brazil
| | - Natalia M Inada
- São Carlos Institute of Physics, University of São Paulo, 13566-590, São Carlos, Brazil
| | - Cristina Kurachi
- São Carlos Institute of Physics, University of São Paulo, 13566-590, São Carlos, Brazil
| |
Collapse
|
5
|
Alam MW, Vedaei SS, Wahid KA. A Fluorescence-Based Wireless Capsule Endoscopy System for Detecting Colorectal Cancer. Cancers (Basel) 2020; 12:E890. [PMID: 32268557 PMCID: PMC7226276 DOI: 10.3390/cancers12040890] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 04/01/2020] [Accepted: 04/02/2020] [Indexed: 12/22/2022] Open
Abstract
Wireless capsule endoscopy (WCE) has been widely used in gastrointestinal (GI) diagnosis that allows the physicians to examine the interior wall of the human GI tract through a pain-free procedure. However, there are still several limitations of the technology, which limits its functionality, ultimately limiting its wide acceptance. Its counterpart, the wired endoscopic system is a painful procedure that demotivates patients from going through the procedure, and adversely affects early diagnosis. Furthermore, the current generation of capsules is unable to automate the detection of abnormality. As a result, physicians are required to spend longer hours to examine each image from the endoscopic capsule for abnormalities, which makes this technology tiresome and error-prone. Early detection of cancer is important to improve the survival rate in patients with colorectal cancer. Hence, a fluorescence-imaging-based endoscopic capsule that automates the detection process of colorectal cancer was designed and developed in our lab. The proof of concept of this endoscopic capsule was tested on porcine intestine and liquid phantom. The proposed WCE system offers great possibilities for future applicability in selective and specific detection of other fluorescently labelled cancers.
Collapse
Affiliation(s)
- Mohammad Wajih Alam
- Departement of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada; (S.S.V.); (K.A.W.)
| | | | | |
Collapse
|