1
|
Montuori P, Gioia M, Sorrentino M, Di Duca F, Pennino F, Messineo G, Maccauro ML, Riello S, Trama U, Triassi M, Nardone A. Determinants Analysis Regarding Household Chemical Indoor Pollution. TOXICS 2023; 11:264. [PMID: 36977029 PMCID: PMC10059753 DOI: 10.3390/toxics11030264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/09/2023] [Accepted: 03/12/2023] [Indexed: 06/18/2023]
Abstract
Indoor household pollution is not yet sufficiently studied in the general population. Over 4 million people die prematurely every year due to air pollution in households. This study aimed to propose quantitative data research through the administration of a KAP (Knowledge, Attitudes, and Practices) Survey Questionnaire. This cross-sectional study administered questionnaires to adults from the metropolitan city of Naples (Italy). Three Multiple Linear Regression Analyses (MLRA) were developed, including Knowledge, Attitudes, and Behavior regarding household chemical air pollution and the related risks. One thousand six hundred seventy subjects received a questionnaire to be filled out and collected anonymously. The mean age of the sample was 44.68 years, ranging from 21-78 years. Most of the people interviewed (76.13%) had good attitudes toward house cleaning, and 56.69% stated paying attention to cleaning products. Results of the regression analysis indicated that positive attitudes were significantly higher among subjects who graduated, with older age, male and non-smokers, but they were correlated with lower knowledge. In conclusion, a behavioral and attitudinal program targeted those with knowledge, such as younger subjects with high educational levels, but do not engage in correct practices towards household indoor chemical pollution.
Collapse
Affiliation(s)
- Paolo Montuori
- Department of Public Health, University “Federico II”, Via Sergio Pansini n° 5, 80131 Naples, Italy
| | - Mariagiovanna Gioia
- Department of Public Health, University “Federico II”, Via Sergio Pansini n° 5, 80131 Naples, Italy
| | - Michele Sorrentino
- Department of Public Health, University “Federico II”, Via Sergio Pansini n° 5, 80131 Naples, Italy
| | - Fabiana Di Duca
- Department of Public Health, University “Federico II”, Via Sergio Pansini n° 5, 80131 Naples, Italy
| | - Francesca Pennino
- Department of Public Health, University “Federico II”, Via Sergio Pansini n° 5, 80131 Naples, Italy
| | - Giuseppe Messineo
- Department of Public Health, University “Federico II”, Via Sergio Pansini n° 5, 80131 Naples, Italy
| | - Maria Luisa Maccauro
- Department of Public Health, University “Federico II”, Via Sergio Pansini n° 5, 80131 Naples, Italy
| | - Simonetta Riello
- Department of Public Health, University “Federico II”, Via Sergio Pansini n° 5, 80131 Naples, Italy
| | - Ugo Trama
- General Directorate of Health, Campania Region, Centro Direzionale Is. C3, 80143 Naples, Italy
| | - Maria Triassi
- Department of Public Health, University “Federico II”, Via Sergio Pansini n° 5, 80131 Naples, Italy
| | - Antonio Nardone
- Department of Public Health, University “Federico II”, Via Sergio Pansini n° 5, 80131 Naples, Italy
| |
Collapse
|
2
|
García-Hernández E, Loera-Quezada MM, Morán-Velázquez DC, López MG, Chable-Vega MA, Santillán-Fernández A, Zavaleta-Mancera HA, Tang JZ, Azadi P, Ibarra-Laclette E, Alatorre-Cobos F. Indirect organogenesis for high frequency shoot regeneration of two cultivars of Sansevieria trifasciata Prain differing in fiber production. Sci Rep 2022; 12:8507. [PMID: 35596065 PMCID: PMC9122912 DOI: 10.1038/s41598-022-12640-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 05/06/2022] [Indexed: 11/23/2022] Open
Abstract
Sansevieria trifasciata is used as an indoor plant, in traditional medicine and as a fiber source. Here we characterized fibers of two of varieties of S. trifasciata, Lorentii and Hahnii, and report a protocol for their propagation based on indirect shoot organogenesis. Structural and ribbon fibers were scattered within leaf parenchyma when viewed with confocal laser scanning microscopy. Chemical analysis of the fibers by mass spectrometry and high-performance chromatography revealed higher contents of cellulose and xylose in Lorentii than in Hahnii and significant differences for total lignin between both. A protocol for de novo shoot production was then developed using leaf explants. Time-course histological analyses showed that the first events of transdifferentiation were triggered preferentially in cells surrounding fibers and vascular bundles. Callogenesis and shoot performances were quantified for both varieties, and 2,4-D at 2 and 3 mg·L-1 yielded the best results for primary calli induction and fresh calli mass. The length, number, and mass of shoots produced did not differ significantly between the two cultivars. The fast morphogenic response of S. trifasciata to in vitro culture may be useful for mass propagation or other biotechnological purposes such as metabolite production.
Collapse
Affiliation(s)
- Eleazar García-Hernández
- Colegio de Postgraduados Campus Campeche, Carretera Haltunchén-Edzná km 17.5, Sihochac, 24450, Campeche, México
| | - Maribel M Loera-Quezada
- Colegio de Postgraduados Campus Campeche, Carretera Haltunchén-Edzná km 17.5, Sihochac, 24450, Campeche, México
| | - Dalia C Morán-Velázquez
- Colegio de Postgraduados Campus Campeche, Carretera Haltunchén-Edzná km 17.5, Sihochac, 24450, Campeche, México
| | - Mercedes G López
- Centro de Investigación y de Estudios Avanzados del I. P. N., Unidad Irapuato, km 9.6 Libramiento Norte Carretera Irapuato-León, Irapuato, 36821, México
| | - Manuel A Chable-Vega
- Colegio de Postgraduados Campus Campeche, Carretera Haltunchén-Edzná km 17.5, Sihochac, 24450, Campeche, México
| | - Alberto Santillán-Fernández
- Conacyt-Colegio de Postgraduados Campus Campeche, Carretera Haltunchén-Edzná km 17.5, Sihochac, 24450, Campeche, México
| | - Hilda A Zavaleta-Mancera
- Colegio de Postgraduados, Programa de Posgrado en Botánica y Unidad de Microscopía Electrónica, km 36.5 Carretera México-Texcoco, Montecillo, 56230, México
| | - John Z Tang
- Complex Carbohydrate Research Center, University of Georgia, Athens, GA, 30602, USA
| | - Parastoo Azadi
- Complex Carbohydrate Research Center, University of Georgia, Athens, GA, 30602, USA
| | | | - Fulgencio Alatorre-Cobos
- Conacyt-Colegio de Postgraduados Campus Campeche, Carretera Haltunchén-Edzná km 17.5, Sihochac, 24450, Campeche, México.
| |
Collapse
|
3
|
Study on the Effect of an Intermittent Ventilation Strategy on Controlling Formaldehyde Concentrations in Office Rooms. ATMOSPHERE 2022. [DOI: 10.3390/atmos13010102] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Material emission and ventilation are two aspects influencing indoor air quality. In this study, a model predictive control (MPC) strategy is proposed for intermittent ventilation system in office buildings, to achieve a healthy indoor environment. The strategy is based on a dynamic model for predicting emissions of volatile organic compounds (VOCs) from materials. The key parameters of formaldehyde from panel furniture in the model are obtained by an improved C-history method and large-scale chamber experiments. The effectiveness of the determined key parameters is validated, which are then used to predict the formaldehyde concentration variation and the pre-ventilation time in a typical office room. In addition, the influence of some main factors (i.e., vacant time, loading ratio, air change rate) on the pre-ventilation time is analyzed. Results indicate that the pre-ventilation time of the intermittent ventilation system ranges from several minutes to several hours. The pre-ventilation time decreases exponentially with the increase in the vacant time, the air change rate, and with the decrease in the loading ratio. When the loading ratio of the furniture is 0.30 m2/m3 and the vacant time is 100 days, the required pre-ventilation time approaches zero. Results further reveal that an air change rate of 2 h−1 is the most effective means for rapid removal of indoor formaldehyde for the cases studied. The proposed strategy should be helpful for achieving effective indoor pollution control.
Collapse
|
4
|
Guard-Cell-Specific Expression of Phototropin2 C-Terminal Fragment Enhances Leaf Transpiration. PLANTS 2021; 11:plants11010065. [PMID: 35009069 PMCID: PMC8747280 DOI: 10.3390/plants11010065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Revised: 12/23/2021] [Accepted: 12/23/2021] [Indexed: 11/17/2022]
Abstract
Phototropins (phot1 and phot2) are plant-specific blue light receptors that mediate chloroplast movement, stomatal opening, and phototropism. Phototropin is composed of the N-terminus LOV1 and LOV2 domains and the C-terminus Ser/Thr kinase domain. In previous studies, 35-P2CG transgenic plants expressing the phot2 C-terminal fragment–GFP fusion protein (P2CG) under the control of 35S promoter showed constitutive phot2 responses, including chloroplast avoidance response, stomatal opening, and reduced hypocotyl phototropism regardless of blue light, and some detrimental growth phenotypes. In this study, to exclude the detrimental growth phenotypes caused by the ectopic expression of P2C and to improve leaf transpiration, we used the PHOT2 promoter for the endogenous expression of GFP-fused P2C (GP2C) (P2-GP2C) and the BLUS1 promoter for the guard-cell-specific expression of GP2C (B1-GP2C), respectively. In P2-GP2C plants, GP2C expression induced constitutive phototropin responses and a relatively dwarf phenotype as in 35-P2CG plants. In contrast, B1-GP2C plants showed the guard-cell-specific P2C expression that induced constitutive stomatal opening with normal phototropism, chloroplast movement, and growth phenotype. Interestingly, leaf transpiration was significantly improved in B1-GP2C plants compared to that in P2-GP2C plants and WT. Taken together, this transgenic approach could be applied to improve leaf transpiration in indoor plants.
Collapse
|
5
|
The Role of HVAC Design and Windows on the Indoor Airflow Pattern and ACH. SUSTAINABILITY 2021. [DOI: 10.3390/su13147931] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The purpose of heating, ventilation, and air conditioning (HVAC) systems are to create optimum thermal comfort and appropriate indoor air quality (IAQ) for occupants. Air ventilation systems can significantly affect the health risk in indoor environments, especially those by contaminated aerosols. Therefore, the main goal of the study is to analyze the indoor airflow patterns in the heating, ventilation, and air conditioning (HVAC) systems and the impact of outlets/windows. The other goal of this study is to simulate the trajectory of the aerosols from a human sneeze, investigate the impact of opening windows on the number of air changes per hour (ACH) and exhibit the role of dead zones with poor ventilation. The final goal is to show the application of computational fluid dynamics (CFD) simulation in improving the HVAC design, such as outlet locations or airflow rate, in addition to the placement of occupants. In this regard, an extensive literature review has been combined with the CFD method to analyze the indoor airflow patterns, ACH, and the role of windows. The airflow pattern analysis shows the critical impact of inflow/outflow and windows. The results show that the CFD model simulation could exhibit optimal placement and safer locations for the occupants to decrease the health risk. The results of the discrete phase simulation determined that the actual ACH could be different from the theoretical ACH as the short circuit and dead zones affect the ACH.
Collapse
|
6
|
A Model for Working Environment Monitoring in Smart Manufacturing. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11062850] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The growing application of smart manufacturing systems and the expansion of the Industry 4.0 model have created a need for new teaching platforms for education, rapid application development, and testing. This research addresses this need with a proposal for a model of working environment monitoring in smart manufacturing, based on emerging wireless sensor technologies and the message queuing telemetry transport (MQTT) protocol. In accordance with the proposed model, a testing platform was developed. The testing platform was built on open-source hardware and software components. The testing platform was used for the validation of the model within the presented experimental environment. The results showed that the proposed model could be developed by mainly using open-source components, which can then be used to simulate different scenarios, applications, and target systems. Furthermore, the presented stable and functional platform proved to be applicable in the process of rapid prototyping, and software development for the targeted systems, as well as for student teaching as part of the engineering education process.
Collapse
|
7
|
Saini J, Dutta M, Marques G. Sensors for indoor air quality monitoring and assessment through Internet of Things: a systematic review. ENVIRONMENTAL MONITORING AND ASSESSMENT 2021; 193:66. [PMID: 33452599 DOI: 10.1007/s10661-020-08781-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 11/30/2020] [Indexed: 06/12/2023]
Abstract
The growing populations around the world are closely associated with rising levels of air pollution. The impact is not restricted to outdoor areas. Moreover, the health of building occupants is also deteriorating due to poor indoor air quality. As per the World Health Organization, indoor air pollution is a leading cause of 1.6 million premature deaths annually. Therefore, numerous companies have started the development of low-cost sensors to monitor indoor air pollution with the Internet of Things-based applications. However, due to the close association of air pollution levels to the mortality and morbidity rates, communities face several limitations while selecting sensors to address this public health challenge. The main contribution of this systematic review is to present a qualitative and quantitative evaluation of low-cost sensors while providing deep insights into the selection criteria for adequate monitoring. The authors in this paper discussed studies published after the year 2015, and it includes an analysis of papers published in the English language only. Moreover, this study highlights crucial research questions, states answers, and provides recommendations for future research studies. The outcomes of this paper will be useful for students, researchers, and industry members concerning the upcoming research and manufacturing activities. The results show that 28 studies (70%) include indoor thermal comfort assessment, 26 (65%) and 12 (30%) studies include CO2 and CO sensors, respectively. In total, 32 (45.7%) out of 71 sensors (whose prices are available) discussed in this study are available in a price below the US $20 over online marketplaces. Furthermore, the authors conclude that 77.5% of the analyzed literature does not include calibration details, and the accuracy specification is missing for 39.4% sensors.
Collapse
Affiliation(s)
- Jagriti Saini
- National Institute of Technical Teacher's Training and Research, Chandigarh, 160019, India.
| | - Maitreyee Dutta
- National Institute of Technical Teacher's Training and Research, Chandigarh, 160019, India
| | - Goncalo Marques
- Polytechnic of Coimbra, ESTGOH, 3400-124, Oliveira do Hospital, Portugal
| |
Collapse
|
8
|
Development of a Wide-Range Non-Dispersive Infrared Analyzer for the Continuous Measurement of CO2 in Indoor Environments. ATMOSPHERE 2020. [DOI: 10.3390/atmos11101024] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Carbon dioxide (CO2) is an indicator of indoor air quality. Ventilation based on the use of a CO2 indicator helps to prevent people from acquiring many diseases, especially respiratory viral infections. Therefore, the monitoring of CO2 is a pivotal issue in the control of indoor air quality. A nondispersive infrared (NDIR) analyzer with a wide range of measurements (i.e., ppmv to percentage levels) was developed for measuring carbon dioxide (CO2) in an indoor environment. The effects of optical pathlength and interfering gases were investigated. The pathlengths of the analyzer were varied at 4.8, 8, 10.4 and 16 m, and the interference gases were CO; NO2; SO2; H2O; BTEX (i.e., benzene, toluene, ethylbenzene and m-/p-xylene) and formaldehyde. The lower detection limit, selectivity and sensitivity were determined to evaluate the performance of the analyzer. It was found that different pathlengths should be used to produce linear calibration curves for CO2 from ppmv to percentage levels. As a result, a wide-range NDIR analyzer, coupled with flexible pathlengths from 4.8 to 10.4 m, was developed. In terms of interference, only H2O should be taken into account due to its high concentration in indoor air. CO should be considered in some special locations at the ppmv level. The measurement errors for ppmv and the percentage levels were 0.4 and 0.9%, respectively.
Collapse
|
9
|
The Citizens’ Views on Adaptation to Bioclimatic Housing Design: Case Study from Greece. SUSTAINABILITY 2020. [DOI: 10.3390/su12124984] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Bioclimatic housing design is regarded as an important pillar towards energy policies. Additionally, it is closely affiliated with the performance of energy efficiency of buildings. The citizens’ views and their adaptation to energy saving practices can be utilized as an important data base in order to design, improve and properly manage urbanization and environmental challenges in the residential sector. For the capitalization of the citizens’ views in Orestiada, the newest city in Greece, simple random sampling was applied on data that were collected via personal interviews and with the use of a structured questionnaire. Reliability and factor analyses were applied for the data processing along with hierarchical log-linear analysis. The latter was utilized for the statistical clustering of citizens into given distinct groups—clusters, arising by factor analysis. The main findings revealed that the citizens are merely aware of bioclimatic principles, while only a small percentage of 28.8% adopts some primary bioclimatic disciplines. Conclusively, it should be noted that there is a need for effective planning towards empowerment on energy efficiency in the residential sector of the city. Notwithstanding, it should not be disregarded the need for the incorporation of conceptual frameworks in urban planning. This is an approach that prerequisites public awareness and the stakeholders’ participation in decision making processes.
Collapse
|