1
|
Darghiasi SF, Farazin A, Ghazali HS. Design of bone scaffolds with calcium phosphate and its derivatives by 3D printing: A review. J Mech Behav Biomed Mater 2024; 151:106391. [PMID: 38211501 DOI: 10.1016/j.jmbbm.2024.106391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 01/05/2024] [Accepted: 01/07/2024] [Indexed: 01/13/2024]
Abstract
Tissue engineering is a fascinating field that combines biology, engineering, and medicine to create artificial tissues and organs. It involves using living cells, biomaterials, and bioengineering techniques to develop functional tissues that can be used to replace or repair damaged or diseased organs in the human body. The process typically starts by obtaining cells from the patient or a donor. These cells are then cultured and grown in a laboratory under controlled conditions. Scaffold materials, such as biodegradable polymers or natural extracellular matrices, are used to provide support and structure for the growing cells. 3D bone scaffolds are a fascinating application within the field of tissue engineering. These scaffolds are designed to mimic the structure and properties of natural bone tissue and serve as a temporary framework for new bone growth. The main purpose of a 3D bone scaffold is to provide mechanical support to the surrounding cells and guide their growth in a specific direction. It acts as a template, encouraging the formation of new bone tissue by providing a framework for cells to attach, proliferate, and differentiate. These scaffolds are typically fabricated using biocompatible materials like ceramics, polymers, or a combination of both. The choice of material depends on factors such as strength, biodegradability, and the ability to facilitate cell adhesion and growth. Advanced techniques like 3D printing have revolutionized the fabrication process of these scaffolds. Using precise layer-by-layer deposition, it allows for the creation of complex, patient-specific geometries, mimicking the intricacies of natural bone structure. This article offers a brief overview of the latest developments in the research and development of 3D printing techniques for creating scaffolds used in bone tissue engineering.
Collapse
Affiliation(s)
- Seyedeh Farnaz Darghiasi
- Department of Mechanical & Biomedical Engineering, Boise State University, Boise, ID, USA; Nanotechnology Department, School of Advanced Technologies, Iran University of Science and Technology (IUST), P.O. Box 16846-13114, Tehran, Iran
| | - Ashkan Farazin
- Department of Solid Mechanics, Faculty of Mechanical Engineering, University of Kashan, P.O. Box 87317-53153, Kashan, Iran; Department of Mechanical Engineering, Stevens Institute of Technology, Castle Point on Hudson, Hoboken, NJ, 07030, USA
| | - Hanieh Sadat Ghazali
- Department of Civil and Mechanical Engineering, University of Missouri-Kansas City, Kansas City, MO, 64110, USA.
| |
Collapse
|
2
|
Gabetti S, Masante B, Schiavi A, Scatena E, Zenobi E, Israel S, Sanginario A, Del Gaudio C, Audenino A, Morbiducci U, Massai D. Adaptable test bench for ASTM-compliant permeability measurement of porous scaffolds for tissue engineering. Sci Rep 2024; 14:1722. [PMID: 38242930 PMCID: PMC10799031 DOI: 10.1038/s41598-024-52159-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 01/15/2024] [Indexed: 01/21/2024] Open
Abstract
Intrinsic permeability describes the ability of a porous medium to be penetrated by a fluid. Considering porous scaffolds for tissue engineering (TE) applications, this macroscopic variable can strongly influence the transport of oxygen and nutrients, the cell seeding process, and the transmission of fluid forces to the cells, playing a crucial role in determining scaffold efficacy. Thus, accurately measuring the permeability of porous scaffolds could represent an essential step in their optimization process. In literature, several methods have been proposed to characterize scaffold permeability. Most of the currently adopted approaches to assess permeability limit their applicability to specific scaffold structures, hampering protocols standardization, and ultimately leading to incomparable results among different laboratories. The content of novelty of this study is in the proposal of an adaptable test bench and in defining a specific testing protocol, compliant with the ASTM International F2952-22 guidelines, for reliable and repeatable measurements of the intrinsic permeability of TE porous scaffolds. The developed permeability test bench (PTB) exploits the pump-based method, and it is composed of a modular permeability chamber integrated within a closed-loop hydraulic circuit, which includes a peristaltic pump and pressure sensors, recirculating demineralized water. A specific testing protocol was defined for characterizing the pressure drop associated with the scaffold under test, while minimizing the effects of uncertainty sources. To assess the operational capabilities and performance of the proposed test bench, permeability measurements were conducted on PLA scaffolds with regular (PS) and random (RS) micro-architecture and on commercial bovine bone matrix-derived scaffolds (CS) for bone TE. To validate the proposed approach, the scaffolds were as well characterized using an alternative test bench (ATB) based on acoustic measurements, implementing a blind randomized testing procedure. The consistency of the permeability values measured using both the test benches demonstrated the reliability of the proposed approach. A further validation of the PTB's measurement reliability was provided by the agreement between the measured permeability values of the PS scaffolds and the theory-based predicted permeability value. Once validated the proposed PTB, the performed measurements allowed the investigation of the scaffolds' transport properties. Samples with the same structure (guaranteed by the fused-deposition modeling technique) were characterized by similar permeability values, and CS and RS scaffolds showed permeability values in agreement with the values reported in the literature for bovine trabecular bone. In conclusion, the developed PTB and the proposed testing protocol allow the characterization of the intrinsic permeability of porous scaffolds of different types and dimensions under controlled flow regimes, representing a powerful tool in view of providing a reliable and repeatable framework for characterizing and optimizing scaffolds for TE applications.
Collapse
Affiliation(s)
- Stefano Gabetti
- Department of Mechanical and Aerospace Engineering and PolitoBIOMed Lab, Politecnico di Torino, Corso Duca Degli Abruzzi, 24, 10129, Turin, Italy
- Centro 3R, Interuniversity Center for the Promotion of the 3Rs Principles in Teaching and Research, Turin, Italy
| | - Beatrice Masante
- Department of Mechanical and Aerospace Engineering and PolitoBIOMed Lab, Politecnico di Torino, Corso Duca Degli Abruzzi, 24, 10129, Turin, Italy
- Centro 3R, Interuniversity Center for the Promotion of the 3Rs Principles in Teaching and Research, Turin, Italy
- Department of Surgical Sciences, CIR-Dental School, University of Turin, Turin, Italy
| | - Alessandro Schiavi
- Applied Metrology and Engineering Division, INRiM-National Institute of Metrological Research, Turin, Italy
| | | | | | - Simone Israel
- Department of Mechanical and Aerospace Engineering and PolitoBIOMed Lab, Politecnico di Torino, Corso Duca Degli Abruzzi, 24, 10129, Turin, Italy
- Centro 3R, Interuniversity Center for the Promotion of the 3Rs Principles in Teaching and Research, Turin, Italy
| | - Alessandro Sanginario
- Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy
| | | | - Alberto Audenino
- Department of Mechanical and Aerospace Engineering and PolitoBIOMed Lab, Politecnico di Torino, Corso Duca Degli Abruzzi, 24, 10129, Turin, Italy
- Centro 3R, Interuniversity Center for the Promotion of the 3Rs Principles in Teaching and Research, Turin, Italy
| | - Umberto Morbiducci
- Department of Mechanical and Aerospace Engineering and PolitoBIOMed Lab, Politecnico di Torino, Corso Duca Degli Abruzzi, 24, 10129, Turin, Italy
- Centro 3R, Interuniversity Center for the Promotion of the 3Rs Principles in Teaching and Research, Turin, Italy
| | - Diana Massai
- Department of Mechanical and Aerospace Engineering and PolitoBIOMed Lab, Politecnico di Torino, Corso Duca Degli Abruzzi, 24, 10129, Turin, Italy.
- Centro 3R, Interuniversity Center for the Promotion of the 3Rs Principles in Teaching and Research, Turin, Italy.
| |
Collapse
|