1
|
Li Y, Zhong X, Yang F. Silencing HE4 alleviates the renal fibrosis in lupus nephritis mice by regulating the C3/MMPs/prss axis. NAUNYN-SCHMIEDEBERG'S ARCHIVES OF PHARMACOLOGY 2024; 397:4823-4831. [PMID: 38157023 PMCID: PMC11166803 DOI: 10.1007/s00210-023-02883-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 11/30/2023] [Indexed: 01/03/2024]
Abstract
To explore the regulatory effect of human epididymis protein 4 (HE4) on renal fibrosis in mice with lupus nephritis (LN) and the underlying mechanism. Ten-week old MRL/LPR mice were injected with HE4 shRNA adenovirus vector through the renal pelvis for 5 days. Renal tissues were extracted for HE and Masson staining to evaluate pathological changes and fibrosis in lupus nephritis mice. The level of urine protein was measured using a biochemical analyzer, while the expression level of HE4 and p-NF-κB p65 in renal tissues was visualized using an immunofluorescence assay. The level of β2-microglobulin (β2-MG), neutrophil gelatinase-associated lipocalin (NGAL), and kidney injury molecule 1 (Kim-1) was determined by the immunohistochemical assay. Western blotting was used to determine the levels of C3, HE4, matrix metalloproteinase-2 (MMP2), MMP9, p-p65, prss23, and prss35 in renal tissues. Compared to wild-type C57BL/6 mice, MRL/LPR mice showed a marked increase in the number of glomeruli, hyperplasic basement membrane, severe infiltration of inflammatory cells in renal tubules and glomeruli, obvious necrosis in glomeruli, elevated fibrosis levels, and increased levels of urine protein, β2-MG, NGAL, Kim-1, C3, HE4, MMP2, MMP9, and p-p65; and decreased levels of prss23 and prss35 were observed in MRL/LPR mice. After the administration of the HE4 shRNA adenovirus vector, the repaired structure of renal tubules and glomeruli improved infiltration of inflammatory cells, reduced collagen fiber and urine protein, suppressed levels of C3, HE4, MMP2, MMP9, and p-P65, and facilitated the expression of prss23 and prss35 which were observed. Silencing HE4 improved renal fibrosis and inhibited inflammation in mice with lupus nephritis, which may play a role in inhibiting C3/MMPs and promoting prss-related protein expression.
Collapse
Affiliation(s)
- Yixia Li
- Department of Nephrology, Affiliated Fuzhou First Hospital of Fujian Medical University, No.190, Dadao Road, Taijiang District, Fuzhou City, Fujian, 350004, China
| | - Xiaorong Zhong
- Department of Nephrology, Affiliated Fuzhou First Hospital of Fujian Medical University, No.190, Dadao Road, Taijiang District, Fuzhou City, Fujian, 350004, China
| | - Feng Yang
- Department of Nephrology, Affiliated Fuzhou First Hospital of Fujian Medical University, No.190, Dadao Road, Taijiang District, Fuzhou City, Fujian, 350004, China.
| |
Collapse
|
2
|
Pohanka M, Zakova J. Urine Test Strip Quantitative Assay with a Smartphone Camera. Int J Anal Chem 2024; 2024:6004970. [PMID: 38529171 PMCID: PMC10963100 DOI: 10.1155/2024/6004970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 02/26/2024] [Accepted: 03/12/2024] [Indexed: 03/27/2024] Open
Abstract
Urine test strips for urinalysis are a common diagnostic tool with minimal costs and are used in various situations including homecare and hospitalization. The coloration scaled by the naked eye is simple, but it is suitable for semiquantitative analysis only. In this paper, a colorimetric assay is developed based on a smartphone digital camera and urine test strips. Assays of pH, albumin, glucose, and lipase activity were performed as a tool for the diagnosis of aciduria, alkaluria, glycosuria, proteinuria, and leukocyturia. The RGB color channels were analyzed in the colorimetric assay, and the assay exerted good sensitivity, and all the particular diagnoses proved to be reliable. The limits of detection for glucose (0.11 mmol/L), albumin (0.15 g/L), and lipase (2.50 U/μL) were low enough to cover the expected physiological concentration, and the range for pH was also satisfactory. The urine test strips with a camera as an output detector proved applicability to spiked urine samples, and the results were also well in comparison to the standard assays which confirms the practical relevance of the presented findings.
Collapse
Affiliation(s)
- Miroslav Pohanka
- Military Faculty of Medicine, University of Defence, Trebesska 1575, Hradec Kralove 50001, Czech Republic
| | - Jitka Zakova
- Military Faculty of Medicine, University of Defence, Trebesska 1575, Hradec Kralove 50001, Czech Republic
| |
Collapse
|
3
|
Divya, Darshna, Sammi A, Chandra P. Design and development of opto-electrochemical biosensing devices for diagnosing chronic kidney disease. Biotechnol Bioeng 2023; 120:3116-3136. [PMID: 37439074 DOI: 10.1002/bit.28490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 06/03/2023] [Accepted: 06/27/2023] [Indexed: 07/14/2023]
Abstract
Chronic kidney disease (CKD) is emerging as one of the major causes of the increase in mortality rate and is expected to become 5th major cause by 2050. Many studies have shown that it is majorly related to various risk factors, and thus becoming one of the major health issues around the globe. Early detection of renal disease lowers the overall burden of disease by preventing individuals from developing kidney impairment. Therefore, diagnosis and prevention of CKD are becoming the major challenges, and in this situation, biosensors have emerged as one of the best possible solutions. Biosensors are becoming one of the preferred choices for various diseases diagnosis as they provide simpler, cost-effective and precise methods for onsite detection. In this review, we have tried to discuss the globally developed biosensors for the detection of CKD, focusing on their design, pattern, and applicability in real samples. Two major classifications of biosensors based on transduction systems, that is, optical and electrochemical, for kidney disease have been discussed in detail. Also, the major focus is given to clinical biomarkers such as albumin, creatinine, and others related to kidney dysfunction. Furthermore, the globally developed sensors for the detection of CKD are discussed in tabulated form comparing their analytical performance, response time, specificity as well as performance in biological fluids.
Collapse
Affiliation(s)
- Divya
- Laboratory of Bio-Physio Sensors and Nanobioengineering School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Darshna
- Laboratory of Bio-Physio Sensors and Nanobioengineering School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Aditi Sammi
- Laboratory of Bio-Physio Sensors and Nanobioengineering School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Pranjal Chandra
- Laboratory of Bio-Physio Sensors and Nanobioengineering School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| |
Collapse
|
4
|
Liu J, Ning K, Fu Y, Sun Y, Liang J. Sulfur quantum dots as a fluorescent sensor for N-acetyl-beta-D-glucosaminidase detection. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 294:122553. [PMID: 36893676 DOI: 10.1016/j.saa.2023.122553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 02/21/2023] [Accepted: 02/23/2023] [Indexed: 06/18/2023]
Abstract
N-acetyl-beta-D-glucosaminidase (NAG) is an important biomarker for early clinical diagnosis of renal disease, suggesting the necessity to develop a fast and sensitive method for its detection. In this paper, we developed a fluorescent sensor based on polyethylene glycol (400) (PEG-400)-modified and H2O2-assisted etched sulfur quantum dots (SQDs). According to the fluorescence inner filter effect (IFE), the fluorescence of SQDs can be quenched by the p-nitrophenol (PNP) generated by NAG-catalyzed hydrolysis of p-Nitrophenyl-N-acetyl-β-D-glucosaminide (PNP-NAG). We successfully used the SQDs as a nano-fluorescent probe to detect the NAG activity from 0.4 to 7.5 U·L-1, with a detection limit of 0.1 U·L-1. Furthermore, the method is highly selective and was successfully used in the detection of NAG activity in bovine serum samples, suggesting its great application prospect in clinical detection.
Collapse
Affiliation(s)
- Jiaxin Liu
- College of Science, Huazhong Agricultural University, Wuhan 430070, China
| | - Keke Ning
- College of Science, Huazhong Agricultural University, Wuhan 430070, China
| | - Yao Fu
- College of Science, Huazhong Agricultural University, Wuhan 430070, China
| | - Yujie Sun
- College of Science, Huazhong Agricultural University, Wuhan 430070, China
| | - Jiangong Liang
- College of Science, Huazhong Agricultural University, Wuhan 430070, China.
| |
Collapse
|
5
|
Bíró E, Szegedi I, Kiss C, Oláh AV, Dockrell M, Price RG, Szabó T. The role of urinary N-acetyl-β-D-glucosaminidase in early detection of acute kidney injury among pediatric patients with neoplastic disorders in a retrospective study. BMC Pediatr 2022; 22:429. [PMID: 35854249 PMCID: PMC9297588 DOI: 10.1186/s12887-022-03416-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 06/10/2022] [Indexed: 12/02/2022] Open
Abstract
Background The 1-year cumulative incidence of AKI reportedly is high (52%) in pediatric neoplastic disorders. About half of these events occur within 2 weeks. However, subclinical AKI episodes may remain unrecognized by the conventional creatinine-based approaches. We investigated the diagnostic value of urinary N-acetyl-β-D-glucosaminidase (uNAG) as an early marker of acute kidney injury (AKI). Methods In our retrospective study, 33 children with neoplastic disorders were inculded who had serial uNAG tests (at least 5 samples/patient) with a total of 367 uNAG measurements. Renal function was determined by cystatin-C and creatinine based GFR, and relative increase of uNAG index (uNAGRI). We focused on detecting both clinical and subclinical AKI episodes (according to Biomarker-Guided Risk Assessment using pRIFLE criteria and /or elevated uNAG levels) and the incidence of chronic kidney damage. Results Sixty episodes in 26 patients, with positivity at least in one parameter of kidney panel, were identified during the observation period. We detected 18/60 clinical and 12/60 subclinical renal episodes. In 27/60 episodes only uNAG values was elevated with no therapeutic consequence at presentation. Two patients were detected with decreased initial creatinine levels with 3 „silent” AKI. In 13 patients, modest elevation of uNAG persisted suggesting mild, reversible tubular damage, while chronic tubuloglomerular injury occurred in 5 patients. Based on ROC analysis for the occurence of AKI, uNAGRI significantly indicated the presence of AKI, the sensitivity and specificity are higher than the changes of GFRCreat. Serial uNAG measurements are recommended for the reduction of the great amount of false positive uNAG results, often due to overhydratation. Conclusion Use of Biomarker-guided Risk Assessment for AKI identified 1.5 × more clinical and subclinical AKI episodes than with creatinine alone in our pediatric cancer patients. Based on the ROC curve for the occurence of AKI, uNAGRI has relatively high sensitivity and specificity comparable to changes of GFRCysC. The advantage of serial uNAG measurements is to decrease the number of false positive results. Trial registration The consent to participate is not applicable because it was not reqired for ethical approval and it is a retrospectiv study. Supplementary Information The online version contains supplementary material available at 10.1186/s12887-022-03416-w.
Collapse
Affiliation(s)
- Erika Bíró
- Department of Pediatrics, University of Debrecen, Faculty of Medicine, Nagyerdei krt 98, 4028, Debrecen, Hungary
| | - István Szegedi
- Department of Pediatrics, University of Debrecen, Faculty of Medicine, Nagyerdei krt 98, 4028, Debrecen, Hungary
| | - Csongor Kiss
- Department of Pediatrics, University of Debrecen, Faculty of Medicine, Nagyerdei krt 98, 4028, Debrecen, Hungary
| | - Anna V Oláh
- Department of Laboratory Medicine, University of Debrecen, Faculty of Medicine, Nagyerdei krt 98, 4028, Debrecen, Hungary
| | - Mark Dockrell
- SWT Institute for Renal Research, Epsom and St Helier University Hospitals NHS Trust, Wrythe Lane, Carshalton, SM5 1AA, London, United Kingdom
| | - Robert G Price
- King's College London, Stamford Street, SE1 9NH, London, United Kingdom
| | - Tamás Szabó
- Department of Pediatrics, University of Debrecen, Faculty of Medicine, Nagyerdei krt 98, 4028, Debrecen, Hungary.
| |
Collapse
|
6
|
Morsby JJ, Smith BD. Advances in Optical Sensors of N-Acetyl-β-d-hexosaminidase ( N-Acetyl-β-d-glucosaminidase). Bioconjug Chem 2022; 33:544-554. [PMID: 35302753 PMCID: PMC9870670 DOI: 10.1021/acs.bioconjchem.2c00057] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
N-Acetyl-β-d-hexosaminidases (EC 3.2.1.52) are exo-acting glycosyl hydrolases that remove N-acetyl-β-d-glucosamine (Glc-NAc) or N-acetyl-β-d-galactosamine (Gal-NAc) from the nonreducing ends of various biomolecules including oligosaccharides, glycoproteins, and glycolipids. The same enzymes are sometimes called N-acetyl-β-d-glucosaminidases, and this review article employs the shorthand descriptor HEX(NAG) to indicate that the terms HEX or NAG are used interchangeably in the literature. The wide distribution of HEX(NAG) throughout the biosphere and its intracellular location in lysosomes combine to make it an important enzyme in food science, agriculture, cell biology, medical diagnostics, and chemotherapy. For more than 50 years, researchers have employed chromogenic derivatives of N-acetyl-β-d-glucosaminide in basic assays for biomedical research and clinical chemistry. Recent conceptual and synthetic innovations in molecular fluorescence sensors, along with concurrent technical improvements in instrumentation, have produced a growing number of new fluorescent imaging and diagnostics methods. A systematic summary of the recent advances in optical sensors for HEX(NAG) is provided under the following headings: assessing kidney health, detection and treatment of infectious disease, fluorescence imaging of cancer, treatment of lysosomal disorders, and reactive probes for chemical biology. The article concludes with some comments on likely future directions.
Collapse
Affiliation(s)
| | - Bradley D. Smith
- Corresponding Author: Bradley D. Smith - Department of Chemistry and Biochemistry, 251 Nieuwland Science Hall, University of Notre Dame, IN 46556, USA.
| |
Collapse
|