Hollensteiner M, Traweger A, Augat P. Anatomic variability of the human femur and its implications for the use of artificial bones in biomechanical testing. BIOMED ENG-BIOMED TE 2024; 0:bmt-2024-0158. [PMID: 38997222 DOI: 10.1515/bmt-2024-0158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Accepted: 07/05/2024] [Indexed: 07/14/2024]
Abstract
Aside from human bones, epoxy-based synthetic bones are regarded as the gold standard for biomechanical testing os osteosyntheses. There is a significant discrepancy in biomechanical testing between the determination of fracture stability due to implant treatment in experimental methods and their ability to predict the outcome of stability and fracture healing in a patient. One possible explanation for this disparity is the absence of population-specific variables such as age, gender, and ethnicity in artificial bone, which may influence the geometry and mechanical properties of bone. The goal of this review was to determine whether commercially available artificial bones adequately represent human anatomical variability for mechanical testing of femoral osteosyntheses. To summarize, the availability of suitable bone surrogates currently limits the validity of mechanical evaluations of implant-bone constructs. The currently available synthetic bones neither accurately reflect the local mechanical properties of human bone, nor adequately represent the necessary variability between various populations, limiting their generalized clinical relevance.
Collapse
Affiliation(s)
- Marianne Hollensteiner
- Institute for Biomechanics, BG Unfallklinik Murnau, Murnau, Germany
- Paracelsus Medical University Salzburg, Salzburg, Austria
| | - Andreas Traweger
- Institute of Tendon and Bone Regeneration, Paracelsus Medical University Salzburg, Salzburg, Austria
| | - Peter Augat
- Institute for Biomechanics, BG Unfallklinik Murnau, Murnau, Germany
- Paracelsus Medical University Salzburg, Salzburg, Austria
| |
Collapse
|
2
|
Conner AA, David D, Yim EKF. The Effects of Biomimetic Surface Topography on Vascular Cells: Implications for Vascular Conduits. Adv Healthc Mater 2024:e2400335. [PMID: 38935920 DOI: 10.1002/adhm.202400335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2024] [Revised: 06/04/2024] [Indexed: 06/29/2024]
Abstract
Cardiovascular diseases (CVDs) are the leading cause of mortality worldwide and represent a pressing clinical need. Vascular occlusions are the predominant cause of CVD and necessitate surgical interventions such as bypass graft surgery to replace the damaged or obstructed blood vessel with a synthetic conduit. Synthetic small-diameter vascular grafts (sSDVGs) are desired to bypass blood vessels with an inner diameter <6 mm yet have limited use due to unacceptable patency rates. The incorporation of biophysical cues such as topography onto the sSDVG biointerface can be used to mimic the cellular microenvironment and improve outcomes. In this review, the utility of surface topography in sSDVG design is discussed. First, the primary challenges that sSDVGs face and the rationale for utilizing biomimetic topography are introduced. The current literature surrounding the effects of topographical cues on vascular cell behavior in vitro is reviewed, providing insight into which features are optimal for application in sSDVGs. The results of studies that have utilized topographically-enhanced sSDVGs in vivo are evaluated. Current challenges and barriers to clinical translation are discussed. Based on the wealth of evidence detailed here, substrate topography offers enormous potential to improve the outcome of sSDVGs and provide therapeutic solutions for CVDs.
Collapse
Affiliation(s)
- Abigail A Conner
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Dency David
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Evelyn K F Yim
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
- Center for Biotechnology and Bioengineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
3
|
Wähnert D, Miersbach M, Colcuc C, Brianza S, Vordemvenne T, Plecko M, Schwarz A. Promoting bone callus formation by taking advantage of the time-dependent fracture gap strain modulation. Front Surg 2024; 11:1376441. [PMID: 38756355 PMCID: PMC11096559 DOI: 10.3389/fsurg.2024.1376441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Accepted: 04/23/2024] [Indexed: 05/18/2024] Open
Abstract
Delayed union and non-union of fractures continue to be a major problem in trauma and orthopedic surgery. These cases are challenging for the surgeon. In addition, these patients suffer from multiple surgeries, pain and disability. Furthermore, these cases are a major burden on healthcare systems. The scientific community widely agrees that the stability of fixation plays a crucial role in determining the outcome of osteosynthesis. The extent of stabilization affects factors like fracture gap strain and fluid flow, which, in turn, influence the regenerative processes positively or negatively. Nonetheless, a growing body of literature suggests that during the fracture healing process, there exists a critical time frame where intervention can stimulate the bone's return to its original form and function. This article provides a summary of existing evidence in the literature regarding the impact of different levels of fixation stability on the strain experienced by newly forming tissues. We will also discuss the timing and nature of this "window of opportunity" and explore how current knowledge is driving the development of new technologies with design enhancements rooted in mechanobiological principles.
Collapse
Affiliation(s)
- Dirk Wähnert
- Department of Trauma and Orthopedic Surgery, Protestant Hospital of Bethel Foundation, University Hospital OWL of Bielefeld University, Bielefeld, Germany
| | - Marco Miersbach
- Department of Trauma and Orthopedic Surgery, Protestant Hospital of Bethel Foundation, University Hospital OWL of Bielefeld University, Bielefeld, Germany
| | - Christian Colcuc
- Department of Trauma and Orthopedic Surgery, Protestant Hospital of Bethel Foundation, University Hospital OWL of Bielefeld University, Bielefeld, Germany
| | | | - Thomas Vordemvenne
- Department of Trauma and Orthopedic Surgery, Protestant Hospital of Bethel Foundation, University Hospital OWL of Bielefeld University, Bielefeld, Germany
| | - Michael Plecko
- Department of Orthopaedics and Traumatology, Trauma Hospital Graz (UKH), Graz, Austria
| | - Angelika Schwarz
- Department of Orthopaedics and Traumatology, Trauma Hospital Graz (UKH), Graz, Austria
| |
Collapse
|
4
|
Yadav TC, Bachhuka A. Tuning foreign body response with tailor-engineered nanoscale surface modifications: fundamentals to clinical applications. J Mater Chem B 2023; 11:7834-7854. [PMID: 37528807 DOI: 10.1039/d3tb01040f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/03/2023]
Abstract
Biomaterials are omnipresent in today's healthcare services and are employed in various applications, including implants, sensors, healthcare accessories, and drug delivery systems. Unfavorable host immunological responses frequently jeopardize the efficacy of biomaterials. As a result, surface modification has received much attention in controlling inflammatory responses since it helps camouflage the biomaterial from the host immune system, influencing the foreign body response (FBR) from protein adsorption to fibrous capsule formation. Surfaces with controlled nanotopography and chemistry, among other surface modification methodologies, have effectively altered the immune response to biomaterials. However, the field is still in its early stages, with only a few studies showing a synergistic effect of surface chemistry and nanotopography on inflammatory and wound healing pathways. Therefore, this review will concentrate on the individual and synergistic effects of surface chemistry and nanotopography on FBR modulation and the molecular processes known to modulate these responses. This review will also provide insights into crucial research gaps and advancements in various tactics for modulating FBR, opening new paths for future research. This will further aid in improving our understanding of the immune response to biomaterials, developing advanced surface modification techniques, designing immunomodulatory biomaterials, and translating discoveries into clinical applications.
Collapse
Affiliation(s)
- Tara Chand Yadav
- Department of Bioinformatics, Faculty of Engineering & Technology, Marwadi University, Gujarat, 360003, India
- Department of Electronics, Electric, and Automatic Engineering, Rovira I Virgili University (URV), Tarragona, 43003, Spain.
| | - Akash Bachhuka
- Department of Electronics, Electric, and Automatic Engineering, Rovira I Virgili University (URV), Tarragona, 43003, Spain.
| |
Collapse
|
5
|
Vilela FB, Silva ES, de Lourdes Noronha Motta Melo M, Oliveira RMP, Capellato P, Sachs D. Polymeric Orthosis with Electromagnetic Stimulator Controlled by Mobile Application for Bone Fracture Healing: Evaluation of Design Concepts for Medical Use. MATERIALS (BASEL, SWITZERLAND) 2022; 15:8141. [PMID: 36431627 PMCID: PMC9698363 DOI: 10.3390/ma15228141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 10/28/2022] [Accepted: 11/02/2022] [Indexed: 06/16/2023]
Abstract
Background: The occurrence of bone fractures is increasing worldwide, mainly due to the health problems that follow the aging population. The use of additive manufacturing and electrical stimulators can be applied for bioactive achievements in bone healing. However, such technologies are difficult to be transferred to medical practice. This work aims to develop an orthosis with a combined magnetic field (CFM) electrostimulator that demonstrates concepts and design aspects that facilitate its use in a real scenario. Methods: A 3D-printed orthosis made of two meshes was manufactured using PLA for outer mechanical stabilization mesh and TPU for inner fixation mesh to avoid mobilization. A CFM stimulator of reduced dimension controlled by a mobile application was coupled onto the orthosis. The design concepts were evaluated by health professionals and their resistance to chemical agents commonly used in daily activities were tested. Their thermal, chemical and electrical properties were also characterized. Results: No degradation was observed after exposure to chemical agents. The CMF achieved proper intensity (20-40 µT). The thermal analysis indicated its appropriate use for being modelled during clinical assessment. Conclusion: An orthosis with a coupled electrostimulator that works with a combined magnetic field and is controlled by mobile application was developed, and it has advantageous characteristics when compared to traditional techniques for application in real medical environments.
Collapse
Affiliation(s)
- Filipe Bueno Vilela
- Centre for Studies and Innovation in Biofunctional Advanced Materials, Institute of Physics and Chemistry, Unifei-Federal University of Itajubá, Av. BPS, 1303, Itajubá 37500-903, MG, Brazil
| | - Eduardo Serafim Silva
- Centre for Studies and Innovation in Biofunctional Advanced Materials, Institute of Physics and Chemistry, Unifei-Federal University of Itajubá, Av. BPS, 1303, Itajubá 37500-903, MG, Brazil
| | | | - Rochelly Mariana Pedroso Oliveira
- Centre for Studies and Innovation in Biofunctional Advanced Materials, Institute of Physics and Chemistry, Unifei-Federal University of Itajubá, Av. BPS, 1303, Itajubá 37500-903, MG, Brazil
| | - Patricia Capellato
- Centre for Studies and Innovation in Biofunctional Advanced Materials, Institute of Physics and Chemistry, Unifei-Federal University of Itajubá, Av. BPS, 1303, Itajubá 37500-903, MG, Brazil
| | - Daniela Sachs
- Centre for Studies and Innovation in Biofunctional Advanced Materials, Institute of Physics and Chemistry, Unifei-Federal University of Itajubá, Av. BPS, 1303, Itajubá 37500-903, MG, Brazil
| |
Collapse
|
6
|
Zuardi LR, de Oliveira FS, Fernandes RR, Gomes MPO, Spriano S, Nanci A, de Oliveira PT. Effects of rmBMP-7 on Osteoblastic Cells Grown on a Nanostructured Titanium Surface. Biomimetics (Basel) 2022; 7:biomimetics7030136. [PMID: 36134940 PMCID: PMC9496167 DOI: 10.3390/biomimetics7030136] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 09/06/2022] [Accepted: 09/14/2022] [Indexed: 01/23/2023] Open
Abstract
This study evaluates the effects of the availability of exogenous BMP-7 on osteoblastic cells’ differentiation on a nanotextured Ti surface obtained by chemical etching (Nano-Ti). The MC3T3-E1 and UMR-106 osteoblastic cell lines were cultured for 5 and 7 days, respectively, on a Nano-Ti surface and on a control surface (Control-Ti) in an osteogenic medium supplemented with either 40 or 200 ng/mL recombinant mouse (rm) BMP-7. The results showed that MC3T3-E1 cells exhibited distinct responsiveness when exposed to each of the two rmBMP-7 concentrations, irrespective of the surface. Even with 40 ng/mL rmBMP-7, important osteogenic effects were noticed for Control-Ti in terms of cell proliferation potential; Runx2, Osx, Alp, Bsp, Opn, and Smad1 mRNA expression; and in situ ALP activity. For Nano-Ti, the effects were limited to higher Alp, Bsp, and Opn mRNA expression and in situ ALP activity. On both surfaces, the osteogenic potential of UMR-106 cultures remained unaltered with 40 ng/mL rmBMP-7, but it was significantly reduced when the cultures were exposed to the 200 ng/mL concentration. The availability of rmBMP-7 to pre-osteoblastic cells at the concentrations used alters the expression profile of osteoblast markers, indicative of the acquisition of a more advanced stage of osteoblastic differentiation. This occurs less pronouncedly on the nanotextured Ti and without reflecting in higher mineralized matrix production by differentiated osteoblasts on both surfaces.
Collapse
Affiliation(s)
- Leonardo Raphael Zuardi
- Department of Basic and Oral Biology, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-904, SP, Brazil
| | - Fabíola Singaretti de Oliveira
- Department of Oral and Maxillofacial Surgery and Periodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-904, SP, Brazil
| | - Roger Rodrigo Fernandes
- Department of Oral and Maxillofacial Surgery and Periodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-904, SP, Brazil
| | - Maria Paula Oliveira Gomes
- Department of Basic and Oral Biology, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-904, SP, Brazil
| | - Silvia Spriano
- Department of Applied Science and Technology, Politecnico di Torino, 10129 Torino, Italy
| | - Antonio Nanci
- Faculté de Médecine Dentaire, Université de Montréal, Montreal, QC H3T 1J4, Canada
| | - Paulo Tambasco de Oliveira
- Department of Basic and Oral Biology, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-904, SP, Brazil
- Correspondence: ; Tel.: +55-16-99623-3663
| |
Collapse
|
7
|
Ganse B, Orth M, Roland M, Diebels S, Motzki P, Seelecke S, Kirsch SM, Welsch F, Andres A, Wickert K, Braun BJ, Pohlemann T. Concepts and clinical aspects of active implants for the treatment of bone fractures. Acta Biomater 2022; 146:1-9. [PMID: 35537678 DOI: 10.1016/j.actbio.2022.05.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 04/24/2022] [Accepted: 05/02/2022] [Indexed: 12/17/2022]
Abstract
Nonunion is a complication of long bone fractures that leads to disability, morbidity and high costs. Early detection is difficult and treatment through external stimulation and revision surgery is often a lengthy process. Therefore, alternative diagnostic and therapeutic options are currently being explored, including the use of external and internal sensors. Apart from monitoring fracture stiffness and displacement directly at the fracture site, it would be desirable if an implant could also vary its stiffness and apply an intervention to promote healing, if needed. This could be achieved either by a predetermined protocol, by remote control, or even by processing data and triggering the intervention itself (self-regulated 'intelligent' or 'smart' implant). So-called active or smart materials like shape memory alloys (SMA) have opened up opportunities to build active implants. For example, implants could stimulate fracture healing by active shortening and lengthening via SMA actuator wires; by emitting pulses, waves, or electromagnetic fields. However, it remains undefined which modes of application, forces, frequencies, force directions, time durations and periods, or other stimuli such implants should ideally deliver for the best result. The present paper reviews the literature on active implants and interventions for nonunion, discusses possible mechanisms of active implants and points out where further research and development are needed to build an active implant that applies the most ideal intervention. STATEMENT OF SIGNIFICANCE: Early detection of delays during fracture healing and timely intervention are difficult due to limitations of the current diagnostic strategies. New diagnostic options are under evaluation, including the use of external and internal sensors. In addition, it would be desirable if an implant could actively facilitate healing ('Intelligent' or 'smart' implant). Implants could stimulate fracture healing via active shortening and lengthening; by emitting pulses, waves, or electromagnetic fields. No such implants exist to date, but new composite materials and alloys have opened up opportunities to build such active implants, and several groups across the globe are currently working on their development. The present paper is the first review on this topic to date.
Collapse
|
8
|
Quantitative Assessment of the Restoration of Original Anatomy after 3D Virtual Reduction of Long Bone Fractures. Diagnostics (Basel) 2022; 12:diagnostics12061372. [PMID: 35741182 PMCID: PMC9222009 DOI: 10.3390/diagnostics12061372] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 05/27/2022] [Accepted: 05/30/2022] [Indexed: 02/04/2023] Open
Abstract
Background: The purpose of this study was to demonstrate the usefulness of 3D image-based virtual reduction by validating the evaluation criteria according to guidelines suggested by the AO Surgery Reference. Methods: For this experiment, 19 intact radial ORTHObones (ORTHObones radius, 3B Scientific, Germany, Hamburg) without any fractures were prepared. All ORTHObones with six cortical marking holes (three points on the distal part and three points on the proximal part) were scanned using a CT scanner twice (before/after intentional fracture of the ORTHObone). After the virtual reduction of all 19 ORTHObones, accuracy evaluations using the four criteria (length variation, apposition variation, alignment variation, Rotation Variation) suggested in the AO Surgery Reference were performed. Results: The mean (M) length variation was 0.42 mm, with 0.01 mm standard deviation (SD). The M apposition variation was 0.48 mm, with 0.40 mm SD. The M AP angulation variation (for alignment variation) was 3.24°, with 2.95° SD. The M lateral angulation variation (for alignment variation) was 0.09°, with 0.13° SD. The M angle of axial rotation was 1.27° with SD: 1.19°. Conclusions: The method of accuracy evaluation used in this study can be helpful in establishing a reliable plan.
Collapse
|
9
|
Inacio JV, Schwarzenberg P, Yoon R, Kantzos A, Malige A, Nwachuku C, Dailey H. Boundary Conditions Matter - Impact of Test Setup On Inferred Construct Mechanics in Plated Distal Femur Osteotomies. J Biomech Eng 2022; 144:1136733. [PMID: 35171212 DOI: 10.1115/1.4053875] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Indexed: 11/08/2022]
Abstract
The mechanics of distal femur fracture fixation has been widely studied in bench tests that employ a variety of approaches for holding and constraining femurs to apply loads. No standard test methods have been adopted for these tests and the impact of test setup on inferred construct mechanics has not been reported. Accordingly, the purpose of this study was to use finite element models to compare the mechanical performance of a supracondylar osteotomy with lateral plating under conditions that replicate several common bench test methods. A literature review was used to define a parameterized virtual model of a plated distal femur osteotomy in axial compression loading with four boundary condition sets ranging from minimally to highly constrained. Axial stiffness, longitudinal motion, and shear motion at the fracture line were recorded for a range of applied loads and bridge spans. The results showed that construct mechanical performance was highly sensitive to boundary conditions imposed by the mechanical test fixtures. Increasing the degrees of constraint, for example by potting and rigidly clamping one or more ends of the specimen, caused up to a 25x increase in axial stiffness of the construct. Shear motion and longitudinal motion at the fracture line, which is an important driver of interfragmentary strain, was also largely influenced by the constraint test setup. These results suggest that caution should be used when comparing reported results between bench tests that use different fixtures and that standardization of testing methods is needed in this field.
Collapse
Affiliation(s)
- Jordan V Inacio
- Department of Mechanical Engineering & Mechanics, Lehigh University, Packard Laboratory, 19 Memorial Drive West, Bethlehem, PA 18015, USA
| | - Peter Schwarzenberg
- Department of Mechanical Engineering & Mechanics, Lehigh University, Packard Laboratory, 19 Memorial Drive West, Bethlehem, PA 18015, USA
| | - Richard Yoon
- Division of Orthopaedic Trauma, Department of Orthopaedic Surgery, Jersey City Medical Center - RWJBarnabas Health, 377 Jersey Ave, Suite 130, Jersey City, NJ 07302, USA
| | - Andrew Kantzos
- Department of Orthopaedic Surgery, St. Luke's University Health Network, 801 Ostrum, 12 Street, Bethlehem, PA 18015, USA
| | - Ajith Malige
- Department of Orthopaedic Surgery, St. Luke's University Health Network, 801 Ostrum, 12 Street, Bethlehem, PA 18015, USA
| | - Chinenye Nwachuku
- Department of Orthopaedic Surgery, St. Luke's University Health Network, 801 Ostrum, 12 Street, Bethlehem, PA 18015, USA
| | - Hannah Dailey
- Department of Mechanical Engineering & Mechanics, Lehigh University, Packard Laboratory, 19 Memorial Drive West, Bethlehem, PA 18015, USA
| |
Collapse
|