1
|
Oushyani Roudsari Z, Karami Y, Khoramrooz SS, Rouhi S, Ghasem H, Khatami SH, Alizadeh M, Ahmad Khosravi N, Mansoriyan A, Ghasemi E, Movahedpour A, Dargahi Z. Electrochemical and optical biosensors for the detection of E. Coli. Clin Chim Acta 2024; 565:119984. [PMID: 39401653 DOI: 10.1016/j.cca.2024.119984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 09/30/2024] [Accepted: 09/30/2024] [Indexed: 10/18/2024]
Abstract
E. coli is a common pathogenic microorganism responsible for numerous food and waterborne illnesses. Traditional detection methods often require long, multi-step processes and specialized equipment. Electrochemical and optical biosensors offer promising alternatives due to their high sensitivity, selectivity, and real-time monitoring capabilities. Recent advancements in sensor development focus on various techniques for detecting E. coli, including optical (fluorescence, colorimetric analysis, surface-enhanced Raman spectroscopy, surface plasmon resonance, localized surface plasmon resonance, chemiluminescence) and electrochemical (amperometric, voltammetry, impedance, potentiometric). Herein, the latest advancements in optical and electrochemical biosensors created for identifying E. coli with an emphasis on surface modifications employing nanomaterials and biomolecules are outlined in this review. Electrochemical biosensors exploit the unique electrochemical properties of E. coli or its specific biomolecules to generate a measurable signal. In contrast, optical biosensors rely on interactions between E. coli and optical elements to generate a detectable response. Moreover, optical detection has been exploited in portable devices such as smart phones and paper-based sensors. Different types of electrodes, nanoparticles, antibodies, aptamers, and fluorescence-based systems have been employed to enhance the sensitivity and specificity of these biosensors. Integrating nanotechnology and biorecognition (which bind to a specific region of the E. coli) elements has enabled the development of portable and miniaturized devices for on-site and point-of-care (POC) applications. These biosensors have demonstrated high sensitivity and offer low detection limits for E. coli detection. The convergence of electrochemical and optical technologies promises excellent opportunities to revolutionize E. coli detection, improving food safety and public health.
Collapse
Affiliation(s)
- Zahra Oushyani Roudsari
- Department of Medical Biotechnology, School of Medicine, Zanjan University of Medical Sciences, Zanjan, Iran
| | - Yousof Karami
- Student of Veterinary Medicine, Faculty of Veterinary Medicine, Shahid Bahonar University of Kerman, Kerman, Iran
| | | | - Saber Rouhi
- Resident of Large Animal Internal Medicine, Department of Clinical Sciences, School of Veterinary Medicine, Shiraz University, Iran
| | - Hassan Ghasem
- Research Center for Environmental Contaminants (RCEC), Abadan University of Medical Sciences, Abadan, Iran
| | - Seyyed Hossein Khatami
- Student Research Committee, Department of Clinical Biochemistry, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mehdi Alizadeh
- Department of Clinical Biochemistry, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Nazanin Ahmad Khosravi
- Department of Microbiology, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Arezoo Mansoriyan
- Department of Microbiology, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | | | - Ahmad Movahedpour
- Cellular and Molecular Research Center, Yasuj University of Medical Sciences, Yasuj, Iran.
| | - Zahra Dargahi
- Department of Microbiology, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| |
Collapse
|
2
|
Akhtarian S, Kaur Brar S, Rezai P. Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection. BIOSENSORS 2024; 14:445. [PMID: 39329820 PMCID: PMC11429591 DOI: 10.3390/bios14090445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2024] [Revised: 09/09/2024] [Accepted: 09/14/2024] [Indexed: 09/28/2024]
Abstract
The rapid and sensitive detection of bacterial contaminants using low-cost and portable point-of-need (PoN) biosensors has gained significant interest in water quality monitoring. Cell-imprinted polymers (CIPs) are emerging as effective and inexpensive materials for bacterial detection as they provide specific binding sites designed to capture whole bacterial cells, especially when integrated into PoN microfluidic devices. However, improving the sensitivity and detection limits of these sensors remains challenging. In this study, we integrated CIP-functionalized stainless steel microwires (CIP-MWs) into a microfluidic device for the impedimetric detection of E. coli bacteria. The sensor featured two parallel microchannels with three-electrode configurations that allowed simultaneous control and electrochemical impedance spectroscopy (EIS) measurements. A CIP-MW and a non-imprinted polymer (NIP)-MW suspended perpendicular to the microchannels served as the working electrodes in the test and control channels, respectively. Electrochemical spectra were fitted with equivalent electrical circuits, and the charge transfer resistances of both cells were measured before and after incubation with target bacteria. The charge transfer resistance of the CIP-MWs after 30 min of incubation with bacteria was increased. By normalizing the change in charge transfer resistance and analyzing the dose-response curve for bacterial concentrations ranging from 0 to 107 CFU/mL, we determined the limits of detection and quantification as 2 × 102 CFU/mL and 1.4 × 104 CFU/mL, respectively. The sensor demonstrated a dynamic range of 102 to 107 CFU/mL, where bacterial counts were statistically distinguishable. The proposed sensor offers a sensitive, cost-effective, durable, and rapid solution for on-site identification of waterborne pathogens.
Collapse
Affiliation(s)
- Shiva Akhtarian
- Department of Mechanical Engineering, York University, Toronto, ON M3J 1P3, Canada;
| | - Satinder Kaur Brar
- Department of Civil Engineering, York University, Toronto, ON M3J 1P3, Canada;
| | - Pouya Rezai
- Department of Mechanical Engineering, York University, Toronto, ON M3J 1P3, Canada;
| |
Collapse
|
3
|
Wei S, Ding B, Wang G, Luo S, Zhao H, Dan X. Population characteristics of pathogenic Escherichia coli in puerperal metritis of dairy cows in Ningxia region of China: a systemic taxa distribution of virulence factors and drug resistance genes. Front Microbiol 2024; 15:1364373. [PMID: 38694808 PMCID: PMC11061491 DOI: 10.3389/fmicb.2024.1364373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Accepted: 03/28/2024] [Indexed: 05/04/2024] Open
Abstract
Escherichia coli (E. coli) is closely associated with the occurrence of puerperal metritis in dairy cows. E. coli carries some the virulence and multi-drug resistant genes, which pose a serious threat to the health of postpartum cows. In this study, E. coli was isolated and identified from the uterine contents of postpartum cows with puerperal metritis in the Ningxia region of China, and its phylogenetic subgroups were determined. Meanwhile, virulence and drug resistance genes carried by E. coli and drug sensitivity were detected, and the characteristics of virulence and drug resistance genes distribution in E. coli phylogroups were further analyzed. The results showed that the isolation rate of E. coli in puerperal metritis samples was 95.2%. E. coli was mainly divided into phylogroups B2 and D, followed by groups A and B1, and was more connected to O157:H7, O169:H4, and ECC-1470 type strains. The virulence genes were mainly dominated by ompF (100%), traT (100%), fimH (97%), papC (96%), csgA (95%), Ang43 (93.9%), and ompC (93%), and the resistance genes were dominated by TEM (99%), tetA (71.7%), aac(3)II (66.7%), and cmlA (53.5%). Additionally, it was observed that the virulence and resistance gene phenotypes could be divided into two subgroups, with subgroup B2 and D having the highest distributions. Drug sensitivity tests also revealed that the E. coli was most sensitive to the fluoroquinolones enrofloxacin, followed by macrolides, aminoglycosides, tetracyclines, β-lactams, peptides and sulfonamides, and least sensitive to lincosamides. These results imply that pathogenic E. coli, which induces puerperal metritis of dairy cows in the Ningxia region of China, primarily belongs to the group B2 and D, contains multiple virulence and drug resistance genes, Moreover, E. coli has evolved resistance to several drugs including penicillin, lincomycin, cotrimoxazole, and streptomycin. It will offer specific guidelines reference for the prevention and treatment of puerperal metritis in dairy cows with E. coli infections in the Ningxia region of China.
Collapse
Affiliation(s)
| | | | | | | | - Hongxi Zhao
- College of Animal Science and Technology, Ningxia University, Yinchuan, China
| | - Xingang Dan
- College of Animal Science and Technology, Ningxia University, Yinchuan, China
| |
Collapse
|
4
|
Du M, Ma J, Zhang Z, Wu G, Wu J, Wang H, Xie X, Wang C. Direct, ultrafast, and sensitive detection of environmental pathogenic microorganisms based on a graphene biosensor. Anal Chim Acta 2023; 1279:341810. [PMID: 37827618 DOI: 10.1016/j.aca.2023.341810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 09/06/2023] [Accepted: 09/08/2023] [Indexed: 10/14/2023]
Abstract
Pathogenic microorganisms in the environment pose a serious threat to global human health. This study developed a reduced graphene oxide (rGO)-field effect transistor (FET) biosensor to realize the rapid and sensitive detection of pathogenic microorganisms. The rGO-FET sensors were prepared by in-situ thermal reduction method, and biorecognition elements were immobilized using a crosslinking agent to realize the surface functionalization of rGO. The rGO-FET biosensors can detect Escherichia coli O157:H7 as low as 1.4 CFU mL-1 within 46 s. The normalized current response was linearly correlated with E. coli concentration in the range of 1.4-1.4 × 107 CFU mL-1. The normalized current response of E. coli O157:H7 was about an order of magnitude higher than those of other microorganisms, indicating that the biosensor has good specificity. The current loss rates of the unmodified rGO-FET sensors and the biosensors modified with anti-E. coli O157:H7 after 30 days of storage at 4 °C were approximately 8% and 15%, respectively. Most importantly, the rGO-FET biosensors can directly detect real samples without pretreatment. Compared with other technologies, the rGO-FET biosensors can detect pathogenic microorganisms with a wider linear range in a shorter time, which is of great importance for the rapid warning and control of pathogenic microorganisms in the environment.
Collapse
Affiliation(s)
- Manman Du
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China; Tianjin Key Lab of Indoor Air Environmental Quality Control, Tianjin, 300072, China; Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China
| | - Jinbiao Ma
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China; Tianjin Key Lab of Indoor Air Environmental Quality Control, Tianjin, 300072, China
| | - Zhiwei Zhang
- Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China
| | - Guangzu Wu
- Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China
| | - Jianguo Wu
- Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China; School of Electronic Information and Automation, Tianjin University of Science and Technology, Tianjin, 300222, China
| | - Hao Wang
- Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China; School of Electronic Information and Automation, Tianjin University of Science and Technology, Tianjin, 300222, China
| | - Xinwu Xie
- Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China; National Bio-Protection Engineering Center, Tianjin, 300161, China.
| | - Can Wang
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China; Tianjin Key Lab of Indoor Air Environmental Quality Control, Tianjin, 300072, China.
| |
Collapse
|
5
|
Akhtarian S, Doostmohammadi A, Archonta DE, Kraft G, Brar SK, Rezai P. Microfluidic Sensor Based on Cell-Imprinted Polymer-Coated Microwires for Conductometric Detection of Bacteria in Water. BIOSENSORS 2023; 13:943. [PMID: 37887136 PMCID: PMC10605092 DOI: 10.3390/bios13100943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 10/17/2023] [Accepted: 10/18/2023] [Indexed: 10/28/2023]
Abstract
The rapid, inexpensive, and on-site detection of bacterial contaminants using highly sensitive and specific microfluidic sensors is attracting substantial attention in water quality monitoring applications. Cell-imprinted polymers (CIPs) have emerged as robust, cost-effective, and versatile recognition materials with selective binding sites for capturing whole bacteria. However, electrochemical transduction of the binding event to a measurable signal within a microfluidic device to develop easy-to-use, compact, portable, durable, and affordable sensors remains a challenge. For this paper, we employed CIP-functionalized microwires (CIP-MWs) with an affinity towards E. coli and integrated them into a low-cost microfluidic sensor to measure the conductometric transduction of CIP-bacteria binding events. The sensor comprised two CIP-MWs suspended perpendicularly to a PDMS microchannel. The inter-wire electrical resistance of the microchannel was measured before, during, and after exposure of CIP-MWs to bacteria. A decline in the inter-wire resistance of the sensor after 30 min of incubation with bacteria was detected. Resistance change normalization and the subsequent analysis of the sensor's dose-response curve between 0 to 109 CFU/mL bacteria revealed the limits of detection and quantification of 2.1 × 105 CFU/mL and 7.3 × 105 CFU/mL, respectively. The dynamic range of the sensor was 104 to 107 CFU/mL where the bacteria counts were statistically distinguishable from each other. A linear fit in this range resulted in a sensitivity of 7.35 μS per CFU/mL. Experiments using competing Sarcina or Listeria cells showed specificity of the sensor towards the imprinted E. coli cells. The reported CIP-MW-based conductometric microfluidic sensor can provide a cost-effective, durable, portable, and real-time solution for the detection of pathogens in water.
Collapse
Affiliation(s)
- Shiva Akhtarian
- Department of Mechanical Engineering, York University, Toronto, ON M3J 1P3, Canada; (S.A.); (A.D.)
| | - Ali Doostmohammadi
- Department of Mechanical Engineering, York University, Toronto, ON M3J 1P3, Canada; (S.A.); (A.D.)
| | - Daphne-Eleni Archonta
- Department of Mechanical Engineering, York University, Toronto, ON M3J 1P3, Canada; (S.A.); (A.D.)
| | - Garrett Kraft
- Sixth Wave Innovations Inc., Halifax, NS B4A 0H3, Canada
| | - Satinder Kaur Brar
- Department of Civil Engineering, York University, Toronto, ON M3J 1P3, Canada;
| | - Pouya Rezai
- Department of Mechanical Engineering, York University, Toronto, ON M3J 1P3, Canada; (S.A.); (A.D.)
| |
Collapse
|
6
|
Duya CO, Okumu FO, Matoetoe MC. Impedimetric nano-collision Escherichia coli analysis based on Silver-Gold bimetallic nanoparticles. Bioelectrochemistry 2023; 151:108403. [PMID: 36848817 DOI: 10.1016/j.bioelechem.2023.108403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 02/13/2023] [Accepted: 02/17/2023] [Indexed: 02/24/2023]
Abstract
An impedimetric detection of E. coli was developed using chemically synthesised bimetallic Ag-Au (1:2) nanoparticles (NPs). The UV-visible spectra of the NPs had absorption bands at 470 and 580 nm for Ag NPs and Au NPs, respectively. In the presence of E. coli, a negative potential shift and a blue shift was observed in the voltammograms and spectra respectively. The complex formed had an oxidation potential at + 0.95 V. Technique choice was based on sensitivity comparison of Differential pulse voltammetry, cyclic voltammetry and impedance spectroscopy in 0.1 M PBS with Impedance being the best choice. Optimum sensing conditions of the NPs-E. coli complex for NPs concentration, incubation period, method modulation amplitude and applied potential were 5 mM, 20 min, 10 mV and + 0.5 V, respectively. The sensor's linearity range, lower limits of detection and quantification were found to be 101-107, 1.88 × 101, 2.34 × 102 cells/mL, respectively. The sensor's applicability was validated by repeatability, stability and selectivity studies showing minimum changes in signal. Potential usage of the sensor in real samples was demonstrated by standard addition analysis of sea and River water samples as well as recovery of spiked water and fruit juices with acceptable % RSD < 2%.
Collapse
Affiliation(s)
- C O Duya
- Department of Chemistry, Cape Peninsula University of Technology, P.O. Box 1906, Bellville, South Africa
| | - F O Okumu
- Department of Physical Sciences, Jaramogi Oginga Odinga University of Science and Technology, P. O. Box 210, 40601, Bondo, Kenya
| | - M C Matoetoe
- Department of Chemistry, Cape Peninsula University of Technology, P.O. Box 1906, Bellville, South Africa.
| |
Collapse
|
7
|
Zhou Q, Natarajan B, Kannan P. Nanostructured biosensing platforms for the detection of food- and water-borne pathogenic Escherichia coli. Anal Bioanal Chem 2023:10.1007/s00216-023-04731-6. [PMID: 37169938 DOI: 10.1007/s00216-023-04731-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Revised: 05/01/2023] [Accepted: 05/03/2023] [Indexed: 05/13/2023]
Abstract
Pathogenic bacterial infection is one of the principal causes affecting human health and ecosystems. The accurate identification of bacteria in food and water samples is of significant interests to maintain safety and health for humans. Culture-based tests are practically tedious and may produce false-positive results, while viable but non-culturable microorganisms (NCMs) cannot be retrieved. Thus, it requires fast, reliable, and low-cost detection strategies for on-field analysis and point-of-care (POC) monitoring. The standard detection methods such as nucleic acid analysis (RT-PCR) and enzyme-linked immunosorbent assays (ELISA) are still challenging in POC practice due to their time-consuming (several hours to days) and expensive laboratory operations. The optical (surface plasmon resonance (SPR), fluorescence, and surface-enhanced Raman scattering (SERS)) and electrochemical-based detection of microbes (early stage of infective diseases) have been considered as alternative routes in the emerging world of nanostructured biosensing since they can attain a faster and concurrent screening of several pathogens in real samples. Moreover, optical and electrochemical detection strategies are opening a new route for the ability of detecting pathogens through the integration of cellphones, which is well fitted for POC analysis. This review article covers the current state of sensitive mechanistic approaches for the screening and detection of Escherichia coli O157:H7 (E. coli) pathogens in food and water samples, which can be potentially applied in clinical and environmental monitoring.
Collapse
Affiliation(s)
- Qiang Zhou
- College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing, Zhejiang Province, 314001, People's Republic of China
| | - Bharathi Natarajan
- College of Medicine, Jiaxing University, Jiaxing, Zhejiang Province, 314001, People's Republic of China.
| | - Palanisamy Kannan
- Department of Endocrinology, First Hospital of Jiaxing (Affiliated Hospital of Jiaxing University), 1882 Zhonghuan South Road, Jiaxing, Zhejiang Province, 314001, People's Republic of China.
| |
Collapse
|
8
|
Kabiraz MP, Majumdar PR, Mahmud MC, Bhowmik S, Ali A. Conventional and advanced detection techniques of foodborne pathogens: A comprehensive review. Heliyon 2023; 9:e15482. [PMID: 37151686 PMCID: PMC10161726 DOI: 10.1016/j.heliyon.2023.e15482] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 03/13/2023] [Accepted: 04/11/2023] [Indexed: 05/09/2023] Open
Abstract
Foodborne pathogens are a major public health concern and have a significant economic impact globally. From harvesting to consumption stages, food is generally contaminated by viruses, parasites, and bacteria, which causes foodborne diseases such as hemorrhagic colitis, hemolytic uremic syndrome (HUS), typhoid, acute, gastroenteritis, diarrhea, and thrombotic thrombocytopenic purpura (TTP). Hence, early detection of foodborne pathogenic microbes is essential to ensure a safe food supply and to prevent foodborne diseases. The identification of foodborne pathogens is associated with conventional (e.g., culture-based, biochemical test-based, immunological-based, and nucleic acid-based methods) and advances (e.g., hybridization-based, array-based, spectroscopy-based, and biosensor-based process) techniques. For industrial food applications, detection methods could meet parameters such as accuracy level, efficiency, quickness, specificity, sensitivity, and non-labor intensive. This review provides an overview of conventional and advanced techniques used to detect foodborne pathogens over the years. Therefore, the scientific community, policymakers, and food and agriculture industries can choose an appropriate method for better results.
Collapse
Affiliation(s)
- Meera Probha Kabiraz
- Department of Biotechnology, Bangladesh Agricultural University, Mymensingh, 2202, Bangladesh
| | - Priyanka Rani Majumdar
- School of Biotechnology and Biomolecular Sciences, UNSW Sydney, Kensington, NSW, 2052, Australia
- Department of Fisheries and Marine Science, Noakhali Science and Technology University, Noakhali, 3814, Bangladesh
| | - M.M. Chayan Mahmud
- CASS Food Research Centre, School of Exercise and Nutrition Sciences, Deakin University, 221 Burwood Highway, VIC, 3125, Australia
| | - Shuva Bhowmik
- Department of Fisheries and Marine Science, Noakhali Science and Technology University, Noakhali, 3814, Bangladesh
- Centre for Bioengineering and Nanomedicine, Faculty of Dentistry, Division of Health Sciences, University of Otago, Dunedin, 9054, New Zealand
- Department of Food Science, University of Otago, Dunedin, 9054, New Zealand
- Corresponding author. Centre for Bioengineering and Nanomedicine, Faculty of Dentistry, Division of Health Sciences, University of Otago, Dunedin, 9054, New Zealand.
| | - Azam Ali
- Centre for Bioengineering and Nanomedicine, Faculty of Dentistry, Division of Health Sciences, University of Otago, Dunedin, 9054, New Zealand
- Corresponding author.
| |
Collapse
|
9
|
Elbehiry A, Abalkhail A, Marzouk E, Elmanssury AE, Almuzaini AM, Alfheeaid H, Alshahrani MT, Huraysh N, Ibrahem M, Alzaben F, Alanazi F, Alzaben M, Anagreyyah SA, Bayameen AM, Draz A, Abu-Okail A. An Overview of the Public Health Challenges in Diagnosing and Controlling Human Foodborne Pathogens. Vaccines (Basel) 2023; 11:vaccines11040725. [PMID: 37112637 PMCID: PMC10143666 DOI: 10.3390/vaccines11040725] [Citation(s) in RCA: 23] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 03/19/2023] [Accepted: 03/21/2023] [Indexed: 03/29/2023] Open
Abstract
Pathogens found in food are believed to be the leading cause of foodborne illnesses; and they are considered a serious problem with global ramifications. During the last few decades, a lot of attention has been paid to determining the microorganisms that cause foodborne illnesses and developing new methods to identify them. Foodborne pathogen identification technologies have evolved rapidly over the last few decades, with the newer technologies focusing on immunoassays, genome-wide approaches, biosensors, and mass spectrometry as the primary methods of identification. Bacteriophages (phages), probiotics and prebiotics were known to have the ability to combat bacterial diseases since the turn of the 20th century. A primary focus of phage use was the development of medical therapies; however, its use quickly expanded to other applications in biotechnology and industry. A similar argument can be made with regards to the food safety industry, as diseases directly endanger the health of customers. Recently, a lot of attention has been paid to bacteriophages, probiotics and prebiotics most likely due to the exhaustion of traditional antibiotics. Reviewing a variety of current quick identification techniques is the purpose of this study. Using these techniques, we are able to quickly identify foodborne pathogenic bacteria, which forms the basis for future research advances. A review of recent studies on the use of phages, probiotics and prebiotics as a means of combating significant foodborne diseases is also presented. Furthermore, we discussed the advantages of using phages as well as the challenges they face, especially given their prevalent application in food safety.
Collapse
Affiliation(s)
- Ayman Elbehiry
- Department of Public Health, College of Public Health and Health Informatics, Qassim University, Al Bukayriyah 52741, Saudi Arabia (E.M.)
- Department of Bacteriology, Mycology and Immunology, Faculty of Veterinary Medicine, University of Sadat City, Sadat City 32511, Egypt
- Correspondence:
| | - Adil Abalkhail
- Department of Public Health, College of Public Health and Health Informatics, Qassim University, Al Bukayriyah 52741, Saudi Arabia (E.M.)
| | - Eman Marzouk
- Department of Public Health, College of Public Health and Health Informatics, Qassim University, Al Bukayriyah 52741, Saudi Arabia (E.M.)
| | - Ahmed Elnadif Elmanssury
- Department of Public Health, College of Public Health and Health Informatics, Qassim University, Al Bukayriyah 52741, Saudi Arabia (E.M.)
| | - Abdulaziz M. Almuzaini
- Department of Veterinary Medicine, College of Agriculture and Veterinary Medicine, Qassim University, Buraydah 52571, Saudi Arabia
| | - Hani Alfheeaid
- Department of Food Science and Human Nutrition, College of Agriculture and Veterinary Medicine, Qassim University, Buraydah 51452, Saudi Arabia
- Human Nutrition, School of Medicine, Nursing and Dentistry, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow G31 2ER, UK
| | - Mohammed T. Alshahrani
- Department of Neurology, Prince Sultan Military Medical City, Riyadh 12233, Saudi Arabia
| | - Nasser Huraysh
- Department of Family Medicine, King Fahad Armed Hospital, Jeddah 23311, Saudi Arabia
| | - Mai Ibrahem
- Department of Public Health, College of Applied Medical Science, King Khalid University, Abha 61421, Saudi Arabia;
- Department of Aquatic Animal Medicine and Management, Faculty of Veterinary Medicine, Cairo University, Cairo 12211, Egypt
| | - Feras Alzaben
- Department of Food Service, King Fahad Armed Hospital, Jeddah 23311, Saudi Arabia
| | - Farhan Alanazi
- Supply Administration, Armed Forces Hospital, King Abdul Aziz Naval Base in Jubail, Jubail 35517, Saudi Arabia
| | - Mohammed Alzaben
- Department of Food Factories Inspection, Operation Sector, Saudi Food and Drug Authority, Riyadh 13513, Saudi Arabia
| | | | | | - Abdelmaged Draz
- Department of Veterinary Medicine, College of Agriculture and Veterinary Medicine, Qassim University, Buraydah 52571, Saudi Arabia
| | - Akram Abu-Okail
- Department of Veterinary Medicine, College of Agriculture and Veterinary Medicine, Qassim University, Buraydah 52571, Saudi Arabia
| |
Collapse
|
10
|
Cao Z, Li C, Yang X, Wang S, Zhang X, Zhao C, Xue B, Gao C, Zhou H, Yang Y, Shen Z, Sun F, Wang J, Qiu Z. Rapid Quantitative Detection of Live Escherichia coli Based on Chronoamperometry. BIOSENSORS 2022; 12:bios12100845. [PMID: 36290982 PMCID: PMC9599875 DOI: 10.3390/bios12100845] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/27/2022] [Accepted: 09/27/2022] [Indexed: 05/31/2023]
Abstract
The rapid quantitative detection of Escherichia coli (E. coli) is of great significance for evaluating water and food safety. At present, the conventional bacteria detection methods cannot meet the requirements of rapid detection in water environments. Herein, we report a method based on chronoamperometry to rapidly and quantitatively detect live E. coli. In this study, the current indicator i0 and the electricity indicator A were used to record the cumulative effect of bacteria on an unmodified glassy carbon electrode (GCE) surface during chronoamperometric detection. Through the analysis of influencing factors and morphological characterization, it was proved that the changes of the two set electrochemical indicator signals had a good correlation with the concentration of E. coli; detection time was less than 5 min, the detection range of E. coli was 104−108 CFU/mL, and the error range was <30%. The results of parallel experiments and spiking experiments showed that this method had good repeatability, stability, and sensitivity. Humic acid and dead cells did not affect the detection results. This study not only developed a rapid quantitative detection method for E. coli in the laboratory, but also realized a bacterial detection scheme based on the theory of bacterial dissolution and adsorption for the first time, providing a new direction and theoretical basis for the development of electrochemical biosensors in the future.
Collapse
Affiliation(s)
- Zhuosong Cao
- School of Environmental and Chemical Engineering, Xi’an Polytechnic University, Xi’an 710600, China
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Chenyu Li
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Xiaobo Yang
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Shang Wang
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Xi Zhang
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Chen Zhao
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Bin Xue
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Chao Gao
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
- School of Marine Science and Technology, Tianjin University, Tianjin 300072, China
| | - Hongrui Zhou
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Yutong Yang
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Zhiqiang Shen
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Feilong Sun
- School of Environmental and Chemical Engineering, Xi’an Polytechnic University, Xi’an 710600, China
| | - Jingfeng Wang
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| | - Zhigang Qiu
- Tianjin Institute of Environmental Medicine and Operational Medicine, Tianjin 300050, China
| |
Collapse
|
11
|
Shi C, Tang Y, Yang H, Yang J, Wu Y, Sun H, Yin S, Wang G. Capture and detection of Escherichia coli with graphene aerogels. J Mater Chem B 2022; 10:8211-8217. [PMID: 36172811 DOI: 10.1039/d2tb01749k] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Some pathogenic bacteria may cause serious food poisoning as well as catastrophic infections. Thus, it is critical to identify bacteria using simple, quick, and sensitive methods. Herein, we fabricate a graphene aerogel-based biosensing system to capture and detect Escherichia coli (E. coli) with high specificity and sensitivity. A graphene aerogel is prepared by a one-step hydrothermal synthesis method without any reducing reagent. With the help of E. coli antibodies and the graphene foam with a porous structure, E. coli can be captured using the detection substrate with high specificity and selectivity. The electrical resistance and electrochemical impedance spectroscopy (EIS) results of the graphene aerogel foam changed with high sensitivity during E. coli adhesion. Moreover, the resistance change of the graphene device can still be observed when the E. coli concentration was as low as 10 cfu mL-1, while there is no obvious resistance change in the use of Staphylococcus aureus. The subsequent EIS test also found that the charge transfer resistance (Rct) of the detection substrate gradually increased during the E. coli capture process. This nanoelectronic biosensor is simple, quick, safe, and very sensitive, and it may be used as a high-throughput platform for pathogenic bacterial detection, bacterial research, and antimicrobial drug screening.
Collapse
Affiliation(s)
- Chenyang Shi
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, Jilin 130012, P. R. China.
| | - Yanan Tang
- Key Laboratory of Bionic Engineering (Ministry of Education), College of Biological and Agricultural Engineering, Jilin University, Changchun, Jilin 130022, P. R. China
| | - Hanyu Yang
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, Jilin 130012, P. R. China.
| | - Junfeng Yang
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, Jilin 130012, P. R. China.
| | - Yuyang Wu
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, Jilin 130012, P. R. China.
| | - Hang Sun
- Key Laboratory of Bionic Engineering (Ministry of Education), College of Biological and Agricultural Engineering, Jilin University, Changchun, Jilin 130022, P. R. China
| | - Shengyan Yin
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, Jilin 130012, P. R. China.
| | - Guangbin Wang
- Department of Orthopedics, Shengjing Hospital of China Medical University, Shenyang, Liaoning, 110004, P. R. China.
| |
Collapse
|
12
|
Chen Y, Liu Y, Wang D, Gao G, Zhi J. Three-Mediator Enhanced Collisions on an Ultramicroelectrode for Selective Identification of Single Saccharomyces cerevisiae. Anal Chem 2022; 94:12630-12637. [PMID: 36068505 DOI: 10.1021/acs.analchem.2c01406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Selective detection of colliding entities, especially cells and microbes, is of great challenge in single-entity electrochemistry. Herein, based on the different cellular electron transport pathways between microbes and mediators, we report a three-mediator system [K3Fe(CN)6, K4Fe(CN)6, and menadione] to achieve redox activity analysis and selective identification of single Saccharomyces cerevisiae without the usage of antibodies. K4Fe(CN)6 in the three-mediator system will oxidize near the electrode surface and increase the local concentration of K3Fe(CN)6, which will promote the redox reaction of S. cerevisiae. The hydrophobic mediator─menadione─can selectively penetrate through the S. cerevisiae membrane and get access to its intracellular redox center and can further react with K3Fe(CN)6 in the bulk solution. In contrast, the mediator can only get access to the bacterial membranes of Escherichia coli and Staphylococcus aureus, which results in different electrochemical collision signals between the above microbes. In the three-mediator system, upward step-like collision signals were observed in S. cerevisiae suspension, which are related to their microbial redox activity. In comparison, E. coli or S. aureus only generated downward current steps because the blockage effect of mediator diffusion suppresses their redox activities. When S. cerevisiae co-existed with E. coli or S. aureus, transients generated by both blockage and redox activity were observed. The approach enables us to trace the collision behaviors of different microbes and distinguish their simultaneous collisions, which is the foundation for further application of electrochemical collision technique in the specific identification of single biological entities.
Collapse
Affiliation(s)
- Yafei Chen
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, PR China.,University of Chinese Academy of Sciences, Beijing.100049, PR China
| | - Yanran Liu
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, PR China.,University of Chinese Academy of Sciences, Beijing.100049, PR China
| | - Dengchao Wang
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, PR China
| | - Guanyue Gao
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, PR China.,University of Chinese Academy of Sciences, Beijing.100049, PR China
| | - Jinfang Zhi
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, PR China.,University of Chinese Academy of Sciences, Beijing.100049, PR China
| |
Collapse
|
13
|
Sande MG, Ferreira D, Rodrigues JL, Melo LDR, Linke D, Silva CJ, Moreira FTC, Sales MGF, Rodrigues LR. Electrochemical Aptasensor for the Detection of the Key Virulence Factor YadA of Yersinia enterocolitica. BIOSENSORS 2022; 12:bios12080614. [PMID: 36005012 PMCID: PMC9405658 DOI: 10.3390/bios12080614] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 08/02/2022] [Accepted: 08/06/2022] [Indexed: 05/31/2023]
Abstract
New point-of-care (POC) diagnosis of bacterial infections are imperative to overcome the deficiencies of conventional methods, such as culture and molecular methods. In this study, we identified new aptamers that bind to the virulence factor Yersinia adhesin A (YadA) of Yersinia enterocolitica using cell-systematic evolution of ligands by exponential enrichment (cell-SELEX). Escherichia coli expressing YadA on the cell surface was used as a target cell. After eight cycles of selection, the final aptamer pool was sequenced by high throughput sequencing using the Illumina Novaseq platform. The sequencing data, analyzed using the Geneious software, was aligned, filtered and demultiplexed to obtain the key nucleotides possibly involved in the target binding. The most promising aptamer candidate, Apt1, bound specifically to YadA with a dissociation constant (Kd) of 11 nM. Apt1 was used to develop a simple electrochemical biosensor with a two-step, label-free design towards the detection of YadA. The sensor surface modifications and its ability to bind successfully and stably to YadA were confirmed by cyclic voltammetry, impedance spectroscopy and square wave voltammetry. The biosensor enabled the detection of YadA in a linear range between 7.0 × 104 and 7.0 × 107 CFU mL−1 and showed a square correlation coefficient >0.99. The standard deviation and the limit of detection was ~2.5% and 7.0 × 104 CFU mL−1, respectively. Overall, the results suggest that this novel biosensor incorporating Apt1 can potentially be used as a sensitive POC detection system to aid the diagnosis of Y. enterocolitica infections. Furthermore, this simple yet innovative approach could be replicated to select aptamers for other (bacterial) targets and to develop the corresponding biosensors for their detection.
Collapse
Affiliation(s)
- Maria G. Sande
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
| | - Débora Ferreira
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
| | - Joana L. Rodrigues
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
| | - Luís D. R. Melo
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
| | - Dirk Linke
- Section for Genetics and Evolutionary Biology, Department of Biosciences, University of Oslo, 0316 Oslo, Norway
| | - Carla J. Silva
- CENTI—Center for Nanotechnology and Smart Materials, Rua Fernando Mesquita 278, 4760-034 Vila Nova de Famalicão, Portugal
- CITEVE—Technological Center for the Textile and Clothing Industries of Portugal, Rua Fernando Mesquita 2785, 4760-034 Vila Nova de Famalicão, Portugal
| | - Felismina T. C. Moreira
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
- BioMark-CINTESIS/ISEP, School of Engineering, Polytechnic Institute of Porto, 4219-015 Porto, Portugal
| | - Maria Goreti F. Sales
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
- BioMark-CINTESIS/ISEP, School of Engineering, Polytechnic Institute of Porto, 4219-015 Porto, Portugal
| | - Ligia R. Rodrigues
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
| |
Collapse
|
14
|
Liu S, Zhao K, Huang M, Zeng M, Deng Y, Li S, Chen H, Li W, Chen Z. Research progress on detection techniques for point-of-care testing of foodborne pathogens. Front Bioeng Biotechnol 2022; 10:958134. [PMID: 36003541 PMCID: PMC9393618 DOI: 10.3389/fbioe.2022.958134] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 06/30/2022] [Indexed: 11/21/2022] Open
Abstract
The global burden of foodborne disease is enormous and foodborne pathogens are the leading cause of human illnesses. The detection of foodborne pathogenic bacteria has become a research hotspot in recent years. Rapid detection methods based on immunoassay, molecular biology, microfluidic chip, metabolism, biosensor, and mass spectrometry have developed rapidly and become the main methods for the detection of foodborne pathogens. This study reviewed a variety of rapid detection methods in recent years. The research advances are introduced based on the above technical methods for the rapid detection of foodborne pathogenic bacteria. The study also discusses the limitations of existing methods and their advantages and future development direction, to form an overall understanding of the detection methods, and for point-of-care testing (POCT) applications to accurately and rapidly diagnose and control diseases.
Collapse
Affiliation(s)
- Sha Liu
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Kaixuan Zhao
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Meiyuan Huang
- Zhuzhou Hospital Affiliated to Xiangya School of Medicine, Department of Pathology, Central South University, Zhuzhou, China
| | - Meimei Zeng
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Yan Deng
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Song Li
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Hui Chen
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Wen Li
- College of Food Science and Engineering, Central South University of Forestry and Technology, Changsha, China
| | - Zhu Chen
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| |
Collapse
|
15
|
Ropero-Vega JL, Redondo-Ortega JF, Rodríguez-Caicedo JP, Rondón-Villarreal P, Flórez-Castillo JM. New PEPTIR-2.0 Peptide Designed for Use as Recognition Element in Electrochemical Biosensors with Improved Specificity towards E. coli O157:H7. Molecules 2022; 27:molecules27092704. [PMID: 35566054 PMCID: PMC9105347 DOI: 10.3390/molecules27092704] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 04/19/2022] [Accepted: 04/20/2022] [Indexed: 12/05/2022] Open
Abstract
The detection of pathogens through alternative methodologies based on electrochemical biosensors is being studied. These devices exhibit remarkable properties, such as simplicity, specificity, and high sensitivity in monitoring pathogens. However, it is necessary to continue conducting studies that adequately improve these characteristics, especially the recognition molecule. This work aims to design and evaluate a new peptide, named PEPTIR-2.0, as a recognition molecule in electrochemical biosensors to detect E. coli O157:H7 in water. PEPTIR-2.0 was obtained from modifications of the PEPTIR-1.0 peptide sequence, which was previously reported and exhibited excellent properties for detecting and quantifying this pathogenic microorganism. PEPTIR-1.0 is a peptide analogous to the TIR (Translocated Intimin Receptor) protein capable of interacting with the Intimin outer membrane. The basis of this study was to obtain, by using bioinformatics tools, a molecule analogous to PEPTIR-1.0 that maintains its three-dimensional structure but increases the hydrophobic interactions between it and Intimin, since these intermolecular forces are the predominant ones. The designed PEPTIR-2.0 peptide was immobilized on screen-printed electrodes modified with gold nanoparticles. The detection capacity of E. coli O157:H7 in water was evaluated using electrochemical impedance spectroscopy in the presence of other microorganisms, such as P. aeruginosa, S. aureus, and non-pathogenic E. coli. The results showed that PEPTIR-2.0 confers remarkable specificity to the biosensor towards detecting E. coli, even higher than PEPTIR-1.0.
Collapse
Affiliation(s)
- Jose Luis Ropero-Vega
- Universidad de Santander, Facultad de Ciencias Naturales, Ciencias Básicas y Aplicadas Para la Sostenibilidad—CIBAS, Calle 70 No. 55-210, Santander, Bucaramanga C.P. 680003, Colombia; (J.F.R.-O.); (J.P.R.-C.); (J.M.F.-C.)
- Correspondence: or ; Tel.: +57-7-6516500 (ext. 1665)
| | - Joshua Felipe Redondo-Ortega
- Universidad de Santander, Facultad de Ciencias Naturales, Ciencias Básicas y Aplicadas Para la Sostenibilidad—CIBAS, Calle 70 No. 55-210, Santander, Bucaramanga C.P. 680003, Colombia; (J.F.R.-O.); (J.P.R.-C.); (J.M.F.-C.)
| | - Juliana Paola Rodríguez-Caicedo
- Universidad de Santander, Facultad de Ciencias Naturales, Ciencias Básicas y Aplicadas Para la Sostenibilidad—CIBAS, Calle 70 No. 55-210, Santander, Bucaramanga C.P. 680003, Colombia; (J.F.R.-O.); (J.P.R.-C.); (J.M.F.-C.)
| | - Paola Rondón-Villarreal
- Universidad de Santander, Facultad de Ciencias Médicas y de la Salud, Instituto de Investigación Masira, Calle 70 No. 55-210, Santander, Bucaramanga C.P. 680003, Colombia;
| | - Johanna Marcela Flórez-Castillo
- Universidad de Santander, Facultad de Ciencias Naturales, Ciencias Básicas y Aplicadas Para la Sostenibilidad—CIBAS, Calle 70 No. 55-210, Santander, Bucaramanga C.P. 680003, Colombia; (J.F.R.-O.); (J.P.R.-C.); (J.M.F.-C.)
| |
Collapse
|
16
|
Razmi N, Hasanzadeh M, Willander M, Nur O. Electrochemical genosensor based on gold nanostars for the detection of Escherichia coli O157:H7 DNA. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1562-1570. [PMID: 35357389 DOI: 10.1039/d2ay00056c] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Escherichia coli O157:H7 (E. coli O157:H7) is an enterohemorrhagic E. coli (EHEC), which has been issued as a major threat to public health worldwide due to fatal contamination of water and food. Thus, its rapid and accurate detection has tremendous importance in environmental monitoring and human health. In this regard, we report a simple and sensitive electrochemical DNA biosensor by targeting Z3276 as a genetic marker in river water. The surface of the designed gold electrode was functionalized with gold nanostars and an aminated specific sensing probe of E. coli O157:H7 to fabricate the genosensor. Cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques were applied for electrochemical characterization and detection. The synthesized gold nanostars were characterized using different characterization techniques. The fabricated DNA-based sensor exhibited a high selective ability for one, two, and three-base mismatched sequences. Regeneration, stability, selectivity, and kinetics of the bioassay were investigated. Under optimal conditions, the fabricated genosensor exhibited a linear response range of 10-5 to 10-17 μM in the standard sample and 7.3 to 1 × 10-17 μM in water samples with a low limit of quantification of 0.01 zM in water samples. The detection strategy based on silver plated gold nanostars and DNA hybridization improved the sensitivity and specificity of the assay for E. coli O157:H7 detection in real water samples without filtration. The detection assay has the advantages of high selectivity, sensitivity, low amounts of reagents, short analysis time, commercialization, and potential application for the determination of other pathogenic bacteria.
Collapse
Affiliation(s)
- Nasrin Razmi
- Physics and Electronics, Department of Science and Technology, Linköping University, SE-601 74 Norrköping, Sweden.
| | - Mohammad Hasanzadeh
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz 51664, Iran
| | - Magnus Willander
- Physics and Electronics, Department of Science and Technology, Linköping University, SE-601 74 Norrköping, Sweden.
| | - Omer Nur
- Physics and Electronics, Department of Science and Technology, Linköping University, SE-601 74 Norrköping, Sweden.
| |
Collapse
|
17
|
A Low-Cost, 3D-Printed Biosensor for Rapid Detection of Escherichia coli. SENSORS 2022; 22:s22062382. [PMID: 35336553 PMCID: PMC8953795 DOI: 10.3390/s22062382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/15/2022] [Accepted: 03/18/2022] [Indexed: 12/10/2022]
Abstract
Detection of bacterial pathogens is significant in the fields of food safety, medicine, and public health, just to name a few. If bacterial pathogens are not properly identified and treated promptly, they can lead to morbidity and mortality, also possibly contribute to antimicrobial resistance. Current bacterial detection methodologies rely solely on laboratory-based techniques, which are limited by long turnaround detection times, expensive costs, and risks of inadequate accuracy; also, the work requires trained specialists. Here, we describe a cost-effective and portable 3D-printed electrochemical biosensor that facilitates rapid detection of certain Escherichia coli (E. coli) strains (DH5α, BL21, TOP10, and JM109) within 15 min using 500 μL of sample, and costs only USD 2.50 per test. The sensor displayed an excellent limit of detection (LOD) of 53 cfu, limit of quantification (LOQ) of 270 cfu, and showed cross-reactivity with strains BL21 and JM109 due to shared epitopes. This advantageous diagnostic device is a strong candidate for frequent testing at point of care; it also has application in various fields and industries where pathogen detection is of interest.
Collapse
|
18
|
Wang A, Wu Z, Huang Y, Zhou H, Wu L, Jia C, Chen Q, Zhao J. A 3D-Printed Microfluidic Device for qPCR Detection of Macrolide-Resistant Mutations of Mycoplasma pneumoniae. BIOSENSORS 2021; 11:bios11110427. [PMID: 34821643 PMCID: PMC8615801 DOI: 10.3390/bios11110427] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/17/2021] [Accepted: 10/26/2021] [Indexed: 11/24/2022]
Abstract
Mycoplasma pneumonia (MP) is a common respiratory infection generally treated with macrolides, but resistance mutations against macrolides are often detected in mycoplasma pneumoniae in China. Rapid and accurate identification of mycoplasma pneumoniae and its mutant type is necessary for precise medication. This paper presents a 3D-printed microfluidic device to achieve this. By 3D printing, the stereoscopic structures such as microvalves, reservoirs, drainage tubes, and connectors were fabricated in one step. The device integrated commercial polymerase chain reaction (PCR) tubes as PCR chambers. The detection was a sample-to-answer procedure. First, the sample, a PCR mix, and mineral oil were respectively added to the reservoirs on the device. Next, the device automatically mixed the sample with the PCR mix and evenly dispensed the mixed solution and mineral oil into the PCR chambers, which were preloaded with the specified primers and probes. Subsequently, quantitative real-time PCR (qPCR) was carried out with the homemade instrument. Within 80 min, mycoplasma pneumoniae and its mutation type in the clinical samples were determined, which was verified by DNA sequencing. The easy-to-make and easy-to-use device provides a rapid and integrated detection approach for pathogens and antibiotic resistance mutations, which is urgently needed on the infection scene and in hospital emergency departments.
Collapse
Affiliation(s)
- Anyan Wang
- College of Metrology and Measurement Engineering, China Jiliang University, Hangzhou 310018, China;
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (Z.W.); (Y.H.); (H.Z.); (J.Z.)
| | - Zhenhua Wu
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (Z.W.); (Y.H.); (H.Z.); (J.Z.)
| | - Yuhang Huang
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (Z.W.); (Y.H.); (H.Z.); (J.Z.)
- College of Life Sciences, Shanghai Normal University, Shanghai 200233, China
| | - Hongbo Zhou
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (Z.W.); (Y.H.); (H.Z.); (J.Z.)
| | - Lei Wu
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (Z.W.); (Y.H.); (H.Z.); (J.Z.)
- Correspondence: (L.W.); (C.J.); (Q.C.)
| | - Chunping Jia
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (Z.W.); (Y.H.); (H.Z.); (J.Z.)
- Correspondence: (L.W.); (C.J.); (Q.C.)
| | - Qiang Chen
- College of Metrology and Measurement Engineering, China Jiliang University, Hangzhou 310018, China;
- Correspondence: (L.W.); (C.J.); (Q.C.)
| | - Jianlong Zhao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (Z.W.); (Y.H.); (H.Z.); (J.Z.)
| |
Collapse
|
19
|
Subjakova V, Oravczova V, Tatarko M, Hianik T. Advances in electrochemical aptasensors and immunosensors for detection of bacterial pathogens in food. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138724] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
20
|
Sun F, Zhang J, Yang Q, Wu W. Quantum dot biosensor combined with antibody and aptamer for tracing food-borne pathogens. FOOD QUALITY AND SAFETY 2021. [DOI: 10.1093/fqsafe/fyab019] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Abstract
Due to the increasing number of food-borne diseases, more attention is being paid to food safety. Food-borne pathogens are the main cause of food-borne diseases, which seriously endanger human health, so it is necessary to detect and control them. Traditional detection methods cannot meet the requirements of rapid detection of food due to many shortcomings, such as being time-consuming, laborious or requiring expensive instrumentation. Quantum dots have become a promising nanotechnology in pathogens tracking and detection because of their excellent optical properties. New biosensor detection methods based on quantum dots are have been gradually developed due to their high sensitivity and high specificity. In this review, we summarize the different characteristics of quantum dots synthesized by carbon, heavy metals and composite materials firstly. Then, attention is paid to the principles, advantages and limitations of the quantum dots biosensor with antibodies and aptamers as recognition elements for recognition and capture of food-borne pathogens. Finally, the great potential of quantum dots in pathogen detection is summarized.
Collapse
|
21
|
Modern Analytical Techniques for Detection of Bacteria in Surface and Wastewaters. SUSTAINABILITY 2021. [DOI: 10.3390/su13137229] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Contamination of surface waters with pathogens as well as all diseases associated with such events are a significant concern worldwide. In recent decades, there has been a growing interest in developing analytical methods with good performance for the detection of this category of contaminants. The most important analytical methods applied for the determination of bacteria in waters are traditional ones (such as bacterial culturing methods, enzyme-linked immunoassay, polymerase chain reaction, and loop-mediated isothermal amplification) and advanced alternative methods (such as spectrometry, chromatography, capillary electrophoresis, surface-enhanced Raman scattering, and magnetic field-assisted and hyphenated techniques). In addition, optical and electrochemical sensors have gained much attention as essential alternatives for the conventional detection of bacteria. The large number of available methods have been materialized by many publications in this field aimed to ensure the control of water quality in water resources. This study represents a critical synthesis of the literature regarding the latest analytical methods covering comparative aspects of pathogen contamination of water resources. All these aspects are presented as representative examples, focusing on two important bacteria with essential implications on the health of the population, namely Pseudomonas aeruginosa and Escherichia coli.
Collapse
|
22
|
Regenerable ZnO/GaAs Bulk Acoustic Wave Biosensor for Detection of Escherichia coli in "Complex" Biological Medium. BIOSENSORS-BASEL 2021; 11:bios11050145. [PMID: 34067116 PMCID: PMC8151011 DOI: 10.3390/bios11050145] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 04/30/2021] [Accepted: 05/05/2021] [Indexed: 12/21/2022]
Abstract
A regenerable bulk acoustic wave (BAW) biosensor is developed for the rapid, label-free and selective detection of Escherichia coli in liquid media. The geometry of the biosensor consists of a GaAs membrane coated with a thin film of piezoelectric ZnO on its top surface. A pair of electrodes deposited on the ZnO film allows the generation of BAWs by lateral field excitation. The back surface of the membrane is functionalized with alkanethiol self-assembled monolayers and antibodies against E. coli. The antibody immobilization was investigated as a function of the concentration of antibody suspensions, their pH and incubation time, designed to optimize the immunocapture of bacteria. The performance of the biosensor was evaluated by detection tests in different environments for bacterial suspensions ranging between 103 and 108 CFU/mL. A linear dependence between the frequency response and the logarithm of E. coli concentration was observed for suspensions ranging between 103 and 107 CFU/mL, with the limit of detection of the biosensor estimated at 103 CFU/mL. The 5-fold regeneration and excellent selectivity towards E. coli detected at 104 CFU/mL in a suspension tinted with Bacillus subtilis at 106 CFU/mL illustrate the biosensor potential for the attractive operation in complex biological media.
Collapse
|
23
|
Sun Y, Kuo C, Lu C, Lin C. Review of recent advances in improved lateral flow immunoassay for the detection of pathogenic
Escherichia
coli
O157
:
H7
in foods. J Food Saf 2020. [DOI: 10.1111/jfs.12867] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Affiliation(s)
- Yu‐Ling Sun
- Aquatic Technology Laboratories Agricultural Technology Research Institute Hsinchu Taiwan
| | - Chiu‐Mei Kuo
- Bioresource Collection and Research Center Food Industry Research and Development Institute Hsinchu Taiwan
| | - Chung‐Lun Lu
- Aquatic Technology Laboratories Agricultural Technology Research Institute Hsinchu Taiwan
| | - Chih‐Sheng Lin
- Department of Biological Science and Technology National Chiao Tung University Hsinchu Taiwan
- Center for Intelligent Drug Systems and Smart Bio‐devices (IDS2B) National Chiao Tung University Hsinchu Taiwan
| |
Collapse
|
24
|
Gupta A, Garg M, Singh S, Deep A, Sharma AL. Highly Sensitive Optical Detection of Escherichia coli Using Terbium-Based Metal-Organic Framework. ACS APPLIED MATERIALS & INTERFACES 2020; 12:48198-48205. [PMID: 32989983 DOI: 10.1021/acsami.0c14312] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Metal-organic frameworks (MOFs) are envisaged as highly useful for the development of biosensors. Herein, for the first time, we report the optical detection of Escherichia coli using a water-dispersible terbium MOF (Tb-BTC; BTC, 1,3,5-benzenetricarboxylic acid). The successful synthesis of Tb-BTC is verified using spectroscopic and morphological techniques like UV-vis, fluorescence and FTIR spectroscopy, X-ray diffraction analysis, and electron microscopy. Tb-BTC has been bio-interfaced with anti-E. coli antibodies and then investigated as a biosensor for E. coli. The biosensor displays detection ability in an analyte concentration range of 1.3 × 102 to 1.3 × 108 cfu/mL with a detection limit of 3 cfu/mL, having a response time of 5 min and a total analysis time of about 20-25 min. The results are also found to be reproducible and specific in the presence of some other interfering bacterial species. As demonstrated, the present sensor provides highly sensitive and specific detection of E. coli in fruit juice sample. To the best of our knowledge, this is the first report to showcase the potential of the MOF-based fluorescent biosensor for the detection of E. coli.
Collapse
Affiliation(s)
- Arushi Gupta
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh -160030, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad -201002, India
| | - Mayank Garg
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh -160030, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad -201002, India
| | - Suman Singh
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh -160030, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad -201002, India
| | - Akash Deep
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh -160030, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad -201002, India
| | - Amit L Sharma
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh -160030, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad -201002, India
| |
Collapse
|