1
|
Kumar P, Rajan R, Upadhyaya K, Behl G, Xiang XX, Huo P, Liu B. Metal oxide nanomaterials based electrochemical and optical biosensors for biomedical applications: Recent advances and future prospectives. ENVIRONMENTAL RESEARCH 2024; 247:118002. [PMID: 38151147 DOI: 10.1016/j.envres.2023.118002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 12/06/2023] [Accepted: 12/19/2023] [Indexed: 12/29/2023]
Abstract
The amalgamation of nanostructures with modern electrochemical and optical techniques gave rise to interesting devices, so-called biosensors. A biosensor is an analytical tool that incorporates various biomolecules with an appropriate physicochemical transducer. Over the past few years, metal oxide nanomaterials (MONMs) have significantly stimulated biosensing research due to their desired functionalities, versatile chemical stability, and low cost along with their unique optical, catalytic, electrical, and adsorption properties that provide an attractive platform for linking the biomolecules, for example, antibodies, nucleic acids, enzymes, and receptor proteins as sensing elements with the transducer for the detection of signals or signal amplifications. The signals to be measured are in direct proportionate to the concentration of the bioanalyte. Because of their simplicity, cost-effectiveness, portability, quick analysis, higher sensitivity, and selectivity against a broad range of biosamples, MONMs-based electrochemical and optical biosensing platforms are exhaustively explored as powerful early-diagnosis tools for point of care applications. Herein, we made a bibliometric analysis of past twenty years (2004-2023) on the application of MONMs as electrochemical and optical biosensing units using Web of Science database and the results of which clearly reveal the increasing number of publications since 2004. Geographical area distribution analysis of these publications shows that China tops the list followed by the United States of America and India. In this review, we first describe the electrochemical and optical properties of MONMs that are crucial for the creation of extremely stable, specific, and sensitive sensors with desirable characteristics. Then, the biomedical applications of MONMs-based bare and hybrid electrochemical and optical biosensing frameworks are highlighted in the light of recent literature. Finally, current limitations and future challenges in the field of biosensing technology are addressed.
Collapse
Affiliation(s)
- Parveen Kumar
- Laboratory of Functional Molecules and Materials, School of Physics and Optoelectronic Engineering, Shandong University of Technology, Xincun West Road 266, Zibo, 255000, China; School of Pharmacy, University College Cork, T12 K8AF, Cork, Ireland
| | - Ramachandran Rajan
- Translational Medical Center, Zibo Central Hospital, Zibo, 255036, Shandong, China
| | - Kapil Upadhyaya
- Chemical Physiology & Biochemistry Department, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Gautam Behl
- Eirgen Pharma Ltd., Westside Business Park, Waterford, Ireland
| | - Xin-Xin Xiang
- Translational Medical Center, Zibo Central Hospital, Zibo, 255036, Shandong, China
| | - Peipei Huo
- Laboratory of Functional Molecules and Materials, School of Physics and Optoelectronic Engineering, Shandong University of Technology, Xincun West Road 266, Zibo, 255000, China.
| | - Bo Liu
- Laboratory of Functional Molecules and Materials, School of Physics and Optoelectronic Engineering, Shandong University of Technology, Xincun West Road 266, Zibo, 255000, China.
| |
Collapse
|
2
|
Abrantes-Coutinho VE, Santos AO, Holanda BEB, Costa HRA, Oliveira TMBF. Integrating machine learning and electrochemistry to develop a glucose biosensor assembled with Ganoderma applanatum lectin. Bioelectrochemistry 2023; 151:108392. [PMID: 36753946 DOI: 10.1016/j.bioelechem.2023.108392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 01/19/2023] [Accepted: 01/27/2023] [Indexed: 02/05/2023]
Abstract
Fungal lectins have enormous biotechnological potential, but limited knowledge about their biochemical and biophysical features prevents their proper use. Herein, we report an innovative alternative to use Ganoderma applanatum lectin (GAL) as a glucose biorecognition element, after identifying the ideal electroanalytical conditions by machine learning studies performed with a homologous agglutinin from the same macrofungus. The research revealed that GAL has moderate resistance to pH (4-8) and temperature (20-60 °C) variations, but its hemagglutinating activity (376.5 HU mg-1 GAL at 20 °C) was better conserved under physiological conditions. Integrating electrochemical data and semi-empirical molecular modeling, biocompatible and electrostatically favorable conditions were found to immobilize the lectin on Prussian blue-modified glassy carbon electrode, after thermal activation of the metal-complex film. The glucose dose-response relationship obtained with the developed biosensor, defined as GAL/ta-PB/GCE, showed a typical Hill equation correlation, suggesting electrodic interactions represented by a sigmoidal mathematical function. GAL/ta-PB/GCE achieved remarkable electroanalytical performance, with emphasis on the detection limit (10.2 pM) and sensitivity (0.012 µA µM-1cm-2). The biosensor was successfully used to quantify glucose in pharmaceutical formulations, reiterating that the association of theoretical and experimental information drives important advances in bioelectrochemical studies.
Collapse
Affiliation(s)
| | - André O Santos
- Centro de Ciência e Tecnologia, Universidade Federal do Cariri, 63048-080 Juazeiro do Norte, CE, Brazil
| | - Brenna E B Holanda
- Centro de Ciência e Tecnologia, Universidade Federal do Cariri, 63048-080 Juazeiro do Norte, CE, Brazil
| | - Heryka R A Costa
- Centro de Ciência e Tecnologia, Universidade Federal do Cariri, 63048-080 Juazeiro do Norte, CE, Brazil
| | - Thiago M B F Oliveira
- Centro de Ciência e Tecnologia, Universidade Federal do Cariri, 63048-080 Juazeiro do Norte, CE, Brazil.
| |
Collapse
|
3
|
Ge S, Sang D, Zou L, Yao Y, Zhou C, Fu H, Xi H, Fan J, Meng L, Wang C. A Review on the Progress of Optoelectronic Devices Based on TiO 2 Thin Films and Nanomaterials. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1141. [PMID: 37049236 PMCID: PMC10096923 DOI: 10.3390/nano13071141] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 03/18/2023] [Accepted: 03/21/2023] [Indexed: 06/19/2023]
Abstract
Titanium dioxide (TiO2) is a kind of wide-bandgap semiconductor. Nano-TiO2 devices exhibit size-dependent and novel photoelectric performance due to their quantum limiting effect, high absorption coefficient, high surface-volume ratio, adjustable band gap, etc. Due to their excellent electronic performance, abundant presence, and high cost performance, they are widely used in various application fields such as memory, sensors, and photodiodes. This article provides an overview of the most recent developments in the application of nanostructured TiO2-based optoelectronic devices. Various complex devices are considered, such as sensors, photodetectors, light-emitting diodes (LEDs), storage applications, and field-effect transistors (FETs). This review of recent discoveries in TiO2-based optoelectronic devices, along with summary reviews and predictions, has important implications for the development of transitional metal oxides in optoelectronic applications for researchers.
Collapse
Affiliation(s)
- Shunhao Ge
- Shandong Key Laboratory of Optical Communication Science and Technology, School of Physics Science and Information Technology, Liaocheng University, Liaocheng 252000, China
| | - Dandan Sang
- Shandong Key Laboratory of Optical Communication Science and Technology, School of Physics Science and Information Technology, Liaocheng University, Liaocheng 252000, China
| | - Liangrui Zou
- Shandong Key Laboratory of Optical Communication Science and Technology, School of Physics Science and Information Technology, Liaocheng University, Liaocheng 252000, China
| | - Yu Yao
- Shandong Key Laboratory of Optical Communication Science and Technology, School of Physics Science and Information Technology, Liaocheng University, Liaocheng 252000, China
| | - Chuandong Zhou
- Shandong Key Laboratory of Optical Communication Science and Technology, School of Physics Science and Information Technology, Liaocheng University, Liaocheng 252000, China
| | - Hailong Fu
- Zhejiang Province Key Laboratory of Quantum Technology and Device, Department of Physics, Zhejiang University, Hangzhou 310027, China
| | - Hongzhu Xi
- Anhui Huadong Photoelectric Technology Research Institute, Wuhu 241002, China
| | - Jianchao Fan
- Shandong Liaocheng Laixin Powder Materials Science and Technology Co., Ltd., Liaocheng 252000, China
| | - Lijian Meng
- Instituto Superior de Engenharia do Porto, Polytechnic of Porto, Rua António Bernardino de Almeida, 4249-015 Porto, Portugal
| | - Cong Wang
- College of Mathematics and Physics, Beijing University of Chemical Technology, Beijing 100029, China
| |
Collapse
|
4
|
Guati C, Gomez-Coma L, Fallanza M, Ortiz I. Progress on the influence of non-enzymatic electrodes characteristics on the response to glucose detection: a review (2016–2022). REV CHEM ENG 2023. [DOI: 10.1515/revce-2022-0058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
Abstract
Abstract
Glucose sensing devices have experienced significant progress in the last years in response to the demand for cost-effective monitoring. Thus, research efforts have been focused on achieving reliable, selective, and sensitive sensors able to monitor the glucose level in different biofluids. The development of enzyme-based devices is challenged by poor stability, time-consuming, and complex purification procedures, facts that have given rise to the synthesis of enzyme-free sensors. Recent advances focus on the use of different components: metal-organic frameworks (MOFs), carbon nanomaterials, or metal oxides. Motivated by this topic, several reviews have been published addressing the sensor materials and synthesis methods, gathering relevant information for the development of new nanostructures. However, the abundant information has not concluded yet in commercial devices and is not useful from an engineering point of view. The dependence of the electrode response on its physico-chemical nature, which would determine the selection and optimization of the materials and synthesis method, remains an open question. Thus, this review aims to critically analyze from an engineering vision the existing information on non-enzymatic glucose electrodes; the analysis is performed linking the response in terms of sensitivity when interferences are present, stability, and response under physiological conditions to the electrode characteristics.
Collapse
Affiliation(s)
- Carlota Guati
- Chemical and Biomolecular Engineering Department , University of Cantabria , 39005 Santander , Spain
| | - Lucía Gomez-Coma
- Chemical and Biomolecular Engineering Department , University of Cantabria , 39005 Santander , Spain
| | - Marcos Fallanza
- Chemical and Biomolecular Engineering Department , University of Cantabria , 39005 Santander , Spain
| | - Inmaculada Ortiz
- Chemical and Biomolecular Engineering Department , University of Cantabria , 39005 Santander , Spain
| |
Collapse
|
5
|
Zhang X, Tan X, Wang P, Qin J. Application of Polypyrrole-Based Electrochemical Biosensor for the Early Diagnosis of Colorectal Cancer. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:674. [PMID: 36839042 PMCID: PMC9967576 DOI: 10.3390/nano13040674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 02/06/2023] [Accepted: 02/06/2023] [Indexed: 06/18/2023]
Abstract
Although colorectal cancer (CRC) is easy to treat surgically and can be combined with postoperative chemotherapy, its five-year survival rate is still not optimistic. Therefore, developing sensitive, efficient, and compliant detection technology is essential to diagnose CRC at an early stage, providing more opportunities for effective treatment and intervention. Currently, the widely used clinical CRC detection methods include endoscopy, stool examination, imaging modalities, and tumor biomarker detection; among them, blood biomarkers, a noninvasive strategy for CRC screening, have shown significant potential for early diagnosis, prediction, prognosis, and staging of cancer. As shown by recent studies, electrochemical biosensors have attracted extensive attention for the detection of blood biomarkers because of their advantages of being cost-effective and having sound sensitivity, good versatility, high selectivity, and a fast response. Among these, nano-conductive polymer materials, especially the conductive polymer polypyrrole (PPy), have been broadly applied to improve sensing performance due to their excellent electrical properties and the flexibility of their surface properties, as well as their easy preparation and functionalization and good biocompatibility. This review mainly discusses the characteristics of PPy-based biosensors, their synthetic methods, and their application for the detection of CRC biomarkers. Finally, the opportunities and challenges related to the use of PPy-based sensors for diagnosing CRC are also discussed.
Collapse
|
6
|
Mohamad Nor N, Ridhuan NS, Abdul Razak K. Progress of Enzymatic and Non-Enzymatic Electrochemical Glucose Biosensor Based on Nanomaterial-Modified Electrode. BIOSENSORS 2022; 12:bios12121136. [PMID: 36551103 PMCID: PMC9775494 DOI: 10.3390/bios12121136] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 11/28/2022] [Accepted: 12/02/2022] [Indexed: 05/09/2023]
Abstract
This review covers the progress of nanomaterial-modified electrodes for enzymatic and non-enzymatic glucose biosensors. Fundamental insights into glucose biosensor components and the crucial factors controlling the electrochemical performance of glucose biosensors are discussed in detail. The metal, metal oxide, and hybrid/composite nanomaterial fabrication strategies for the modification of electrodes, mechanism of detection, and significance of the nanomaterials toward the electrochemical performance of enzymatic and non-enzymatic glucose biosensors are compared and comprehensively reviewed. This review aims to provide readers with an overview and underlying concept of producing a reliable, stable, cost-effective, and excellent electrochemical performance of a glucose biosensor.
Collapse
Affiliation(s)
- Noorhashimah Mohamad Nor
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Nibong Tebal 14300, Pulau Pinang, Malaysia
| | - Nur Syafinaz Ridhuan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Nibong Tebal 14300, Pulau Pinang, Malaysia
| | - Khairunisak Abdul Razak
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Nibong Tebal 14300, Pulau Pinang, Malaysia
- NanoBiotechnology Research & Innovation (NanoBRI), Institute for Research in Molecular Medicine, Universiti Sains Malaysia, Gelugor 11800, Pulau Pinang, Malaysia
- Correspondence:
| |
Collapse
|
7
|
Mohammadpour-Haratbar A, Mohammadpour-Haratbar S, Zare Y, Rhee KY, Park SJ. A Review on Non-Enzymatic Electrochemical Biosensors of Glucose Using Carbon Nanofiber Nanocomposites. BIOSENSORS 2022; 12:bios12111004. [PMID: 36421123 PMCID: PMC9688744 DOI: 10.3390/bios12111004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 10/30/2022] [Accepted: 11/02/2022] [Indexed: 05/09/2023]
Abstract
Diabetes mellitus has become a worldwide epidemic, and it is expected to become the seventh leading cause of death by 2030. In response to the increasing number of diabetes patients worldwide, glucose biosensors with high sensitivity and selectivity have been developed for rapid detection. The selectivity, high sensitivity, simplicity, and quick response of electrochemical biosensors have made them a popular choice in recent years. This review summarizes the recent developments in electrodes for non-enzymatic glucose detection using carbon nanofiber (CNF)-based nanocomposites. The electrochemical performance and limitations of enzymatic and non-enzymatic glucose biosensors are reviewed. Then, the recent developments in non-enzymatic glucose biosensors using CNF composites are discussed. The final section of the review provides a summary of the challenges and perspectives, for progress in non-enzymatic glucose biosensors.
Collapse
Affiliation(s)
- Ali Mohammadpour-Haratbar
- Biomaterials and Tissue Engineering Research Group, Department of Interdisciplinary Technologies, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, Tehran 1949635881, Iran
| | | | - Yasser Zare
- Biomaterials and Tissue Engineering Research Group, Department of Interdisciplinary Technologies, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, Tehran 1949635881, Iran
- Correspondence: (Y.Z.); (K.Y.R.); (S.-J.P.)
| | - Kyong Yop Rhee
- Department of Mechanical Engineering (BK21 Four), College of Engineering, Kyung Hee University, Yongin 17104, Korea
- Correspondence: (Y.Z.); (K.Y.R.); (S.-J.P.)
| | - Soo-Jin Park
- Department of Chemistry, Inha University, Incheon 22212, Korea
- Correspondence: (Y.Z.); (K.Y.R.); (S.-J.P.)
| |
Collapse
|
8
|
Mostafavi E, Medina-Cruz D, Truong LB, Kaushik A, Iravani S. Selenium-based nanomaterials for biosensing applications. MATERIALS ADVANCES 2022; 3:7742-7756. [PMID: 36353516 PMCID: PMC9619417 DOI: 10.1039/d2ma00756h] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 09/11/2022] [Indexed: 05/03/2023]
Abstract
The unique chemical and physical features of nanomaterials make them ideal for developing new and better sensing devices, particularly biosensors. Various types of nanoparticles, including metal, oxide, and semiconductor nanostructures, have been utilized to manufacture biosensors, and each kind of nanoparticle plays a unique role in the sensing system. Nanoparticles provide critical roles such as immobilizing biomolecules, catalyzing electrochemical processes, enhancing electron transport between electrode surfaces and proteins, identifying biomolecules, and even functioning as the reactant for the catalytic reaction. Among all the potential nanosystems to be used in biosensors, selenium nanoparticle (SeNP) features have sparked a growing interest in their use in bridging biological recognition events and signal transduction, as well as in developing biosensing devices with novel applications for identification, quantification, and study of different analytes of biological relevance. The optical, physical, and chemical characteristics of differently shaped SeNPs opened up a world of possibilities for developing biosensors of biomedical interest. The outstanding biocompatibility, conductivity, catalytic characteristics, high surface-to-volume ratio, and high density of SeNPs have enabled their widespread use in developing electrochemical biosensors with superior analytical performance compared to other designs of biosensors. This review summarizes recent and ongoing advances, current challenges, and future research perspectives on real-world applications of Se-based nanobiosensors to detect biologically relevant analytes such as hydrogen peroxide, heavy metals, or glucose. Due to the superior properties and multifunctionality of Se-NPs biosensors, these structures can open up considerable new horizons in the future of healthcare and medicine.
Collapse
Affiliation(s)
- Ebrahim Mostafavi
- Stanford Cardiovascular Institute, Stanford University School of Medicine Stanford CA 94305 USA
- Department of Medicine, Stanford University School of Medicine Stanford CA 94305 USA
| | - David Medina-Cruz
- Chemical Engineering Department, Northeastern University Boston MA 02115 USA
| | - Linh B Truong
- Chemical Engineering Department, Northeastern University Boston MA 02115 USA
| | - Ajeet Kaushik
- NanoBioTech Laboratory, Department of Environmental Engineering, Florida Polytechnic University Lakeland FL-33805 USA
- School of Engineering, University of Petroleum and Energy Studies (UPES) Dehradun Uttarakhand India
| | - Siavash Iravani
- Faculty of Pharmacy and Pharmaceutical Sciences, Isfahan University of Medical Sciences Isfahan Iran
| |
Collapse
|
9
|
Insights into the Design of An Enzyme Free Sustainable Sensing Platform for Efavirenz. Catalysts 2022. [DOI: 10.3390/catal12080830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
In this study, a new hybrid sensor was developed using titanium oxide nanoparticles (TiO2-NPs) and nafion as an anchor agent on a glassy carbon electrode (GCE/TiO2-NPs-nafion) to detect efavirenz (EFV), an anti-HIV medication. TiO2-NPs was synthesized using Eucalyptus globulus leaf extract and characterized using ultraviolet–visible spectroscopy (UV–VIS), scanning electron microscopy (SEM), X-ray diffraction (XRD), and energy-dispersive spectroscopy (EDS). The electrochemical and sensing properties of the developed sensor for EFV were assessed using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The current response of GCE/TiO2-NPs-nafion electrode towards the oxidation of EFV was greater compared to the bare GCE and GCE/TiO2-NPs electrodes. A linear dynamic range of 4.5 to 18.7 µM with 0.01 µM limit of detection was recorded on the electrode using differential pulse voltammetry (DPV). The electrochemical sensor demonstrated good selectivity and practicality for detecting EFV in pharmaceuticals (EFV drugs) with excellent recovery rates, ranging from 92.0–103.9%. The reactive sites of EFV have been analyzed using quantum chemical calculations based on density functional theory (DFT). Monte Carlo (MC) simulations revealed a strong electrostatic interaction on the substrate-adsorbate (GCE/TiO2-NPs-nafion-EFV) system. Results show good agreement between the MC computed adsorption energies and the experimental CV results for EFV. The stronger adsorption energy of nafion onto the GCE/TiO2-NPs substrate contributed to the catalytic role in the signal amplification for sensing of EFV. Our results provide an effective way to explore the design of new 2D materials for sensing of EFV, which is highly significant in medicinal and materials chemistry.
Collapse
|
10
|
Engineered Nanoparticle-Protein Interactions Influence Protein Structural Integrity and Biological Significance. NANOMATERIALS 2022; 12:nano12071214. [PMID: 35407332 PMCID: PMC9002493 DOI: 10.3390/nano12071214] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 03/21/2022] [Accepted: 03/24/2022] [Indexed: 02/01/2023]
Abstract
Engineered nanoparticles (ENPs) are artificially synthesized particles with unique physicochemical properties. ENPs are being extensively used in several consumer items, elevating the probability of ENP exposure to biological systems. ENPs interact with various biomolecules like lipids, proteins, nucleic acids, where proteins are most susceptible. The ENP-protein interactions are mostly studied for corona formation and its effect on the bio-reactivity of ENPs, however, an in-depth understanding of subsequent interactive effects on proteins, such as alterations in their structure, conformation, free energy, and folding is still required. The present review focuses on ENP-protein interactions and the subsequent effects on protein structure and function followed by the therapeutic potential of ENPs for protein misfolding diseases.
Collapse
|
11
|
Naikoo GA, Salim H, Hassan IU, Awan T, Arshad F, Pedram MZ, Ahmed W, Qurashi A. Recent Advances in Non-Enzymatic Glucose Sensors Based on Metal and Metal Oxide Nanostructures for Diabetes Management- A Review. Front Chem 2021; 9:748957. [PMID: 34631670 PMCID: PMC8493127 DOI: 10.3389/fchem.2021.748957] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 09/09/2021] [Indexed: 01/23/2023] Open
Abstract
There is an undeniable growing number of diabetes cases worldwide that have received widespread global attention by many pharmaceutical and clinical industries to develop better functioning glucose sensing devices. This has called for an unprecedented demand to develop highly efficient, stable, selective, and sensitive non-enzymatic glucose sensors (NEGS). Interestingly, many novel materials have shown the promising potential of directly detecting glucose in the blood and fluids. This review exclusively encompasses the electrochemical detection of glucose and its mechanism based on various metal-based materials such as cobalt (Co), nickel (Ni), zinc (Zn), copper (Cu), iron (Fe), manganese (Mn), titanium (Ti), iridium (Ir), and rhodium (Rh). Multiple aspects of these metals and their oxides were explored vis-à-vis their performance in glucose detection. The direct glucose oxidation via metallic redox centres is explained by the chemisorption model and the incipient hydrous oxide/adatom mediator (IHOAM) model. The glucose electrooxidation reactions on the electrode surface were elucidated by equations. Furthermore, it was explored that an effective detection of glucose depends on the aspect ratio, surface morphology, active sites, structures, and catalytic activity of nanomaterials, which plays an indispensable role in designing efficient NEGS. The challenges and possible solutions for advancing NEGS have been summarized.
Collapse
Affiliation(s)
- Gowhar A. Naikoo
- Department of Mathematics and Sciences, College of Arts and Applied Sciences, Dhofar University, Salalah, Oman
| | - Hiba Salim
- Department of Mathematics and Sciences, College of Arts and Applied Sciences, Dhofar University, Salalah, Oman
| | | | - Tasbiha Awan
- Department of Mathematics and Sciences, College of Arts and Applied Sciences, Dhofar University, Salalah, Oman
| | - Fareeha Arshad
- Department of Biochemistry, Aligarh Muslim University, Aligarh, India
| | - Mona Z. Pedram
- Mechanical Engineering-Energy Division, K. N. Toosi University of Technology, Tehran, Iran
| | - Waqar Ahmed
- School of Mathematics and Physics, College of Science, University of Lincoln, Lincoln, United Kingdom
| | - Ahsanulhaq Qurashi
- Department of Chemistry, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
| |
Collapse
|
12
|
Jamil S, Nasir M, Ali Y, Nadeem S, Rashid S, Javed MY, Hayat A. Cr 2O 3-TiO 2-Modified Filter Paper-Based Portable Nanosensors for Optical and Colorimetric Detection of Hydrogen Peroxide. ACS OMEGA 2021; 6:23368-23377. [PMID: 34549136 PMCID: PMC8444288 DOI: 10.1021/acsomega.1c03119] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 08/23/2021] [Indexed: 05/11/2023]
Abstract
In the present approach, a Cr2O3-TiO2-modified, portable, and biomimetic nanosensor was designed to meet the requirement of a robust and colorimetric sensing of hydrogen peroxide. Cr2O3-TiO2 nanocomposites prepared via the hydrothermal method were fabricated as a transducer surface on the filter paper using the sol-gel matrix. The color on the filter paper sensor changed from green to blue upon the addition of hydrogen peroxide in the presence of TMB. This change in the color intensity was linear with the concentration of H2O2. RGB software was used as a color analyzing model to evaluate the optical signals. This paper-based colorimetric platform provided us with an improved analytical figure of merit with a linear range of 0.005-100 μM with 0.003 μM limit of detection. The real sample analysis and excellent anti-interference potential results proved the good analytical performance of the proposed design, providing a more promising tool for colorimetric H2O2 detection. Introducing Cr2O3-TiO2 nanocomposite-based paper sensors, being a novel method for optical and colorimetric detection, can pave the way for the development of other sensing devices for the detection of different analytes.
Collapse
Affiliation(s)
- Sundas Jamil
- Department
of Chemistry, School of Science, University
of Management and Technology, Lahore 54000, Pakistan
- Interdisciplinary
Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad Lahore Campus, Lahore 54000, Pakistan
| | - Muhammad Nasir
- Interdisciplinary
Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad Lahore Campus, Lahore 54000, Pakistan
| | - Yaqeen Ali
- Computer
Science Department, COMSATS University Islamabad
Lahore Campus, Lahore 54000, Pakistan
| | - Sohail Nadeem
- Department
of Chemistry, School of Science, University
of Management and Technology, Lahore 54000, Pakistan
| | - Sidra Rashid
- Interdisciplinary
Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad Lahore Campus, Lahore 54000, Pakistan
| | - Muhammad Yaqoob Javed
- Department
of Electrical Engineering, COMSATS University
Islamabad Lahore Campus, Lahore 54000, Pakistan
| | - Akhtar Hayat
- Interdisciplinary
Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad Lahore Campus, Lahore 54000, Pakistan
| |
Collapse
|