1
|
Zhang C, Liu X, Hu J, Han H. Enhancing surface sensing performance of cascaded high contrast gratings using bound states in the continuum. OPTICS EXPRESS 2024; 32:6644-6657. [PMID: 38439363 DOI: 10.1364/oe.515816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 01/28/2024] [Indexed: 03/06/2024]
Abstract
We proposed the cascaded high contrast grating (CHCG) structure to enhance surface sensing capabilities through bound states in the continuum (BICs). Utilizing the finite element method (FEM) and rigorous coupled-wave analysis (RCWA), we studied the dispersion relations, far-field contribution CHCGs, and near-field distributions of BICs corresponding to resonance peaks at different wavelengths. Results demonstrate the ability to precisely control symmetry-protected BIC (SP-BIC) and Friedrich-Wintgen BIC (FW-BIC) resonance peaks by altering incident angles and structural parameters, enhancing structure robustness and tunability. Significantly, modes 1 and 2 have demonstrated substantial enhancement in surface refractive index sensing, achieving highest sensitivities at 51 nm/RIU and the figure of merit reaching 490.8 RIU-1, indicating notable advancement in detecting subtle surface changes. In contrast, mode 3 has shown robust performance in bulk refractive index sensing, achieving a sensitivity of 602 nm/RIU and a figure of merit of 5189.65 RIU-1. These findings underscore the significant potential of the structure as a high-performance integrated sensor, particularly for precise environmental and biological monitoring in surface refractive index sensing.
Collapse
|
2
|
Cu DT, Wu HW, Chen HP, Su LC, Kuo CC. Exploiting Thin-Film Properties and Guided-Mode Resonance for Designing Ultrahigh-Figure-of-Merit Refractive Index Sensors. SENSORS (BASEL, SWITZERLAND) 2024; 24:960. [PMID: 38339677 PMCID: PMC10856855 DOI: 10.3390/s24030960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 01/30/2024] [Accepted: 01/30/2024] [Indexed: 02/12/2024]
Abstract
Guided-mode resonance (GMR) gratings have emerged as a promising sensing technology, with a growing number of applications in diverse fields. This study aimed to identify the optimal design parameters of a simple-to-fabricate and high-performance one-dimensional GMR grating. The structural parameters of the GMR grating were optimized, and a high-refractive-index thin film was simulated on the grating surface, resulting in efficient confinement of the electric field energy within the waveguide. Numerical simulations demonstrated that the optimized GMR grating exhibited remarkable sensitivity (252 nm/RIU) and an extremely narrow full width at half maximum (2 × 10-4 nm), resulting in an ultra-high figure of merit (839,666) at an incident angle of 50°. This performance is several orders of magnitude higher than that of conventional GMR sensors. To broaden the scope of the study and to make it more relevant to practical applications, simulations were also conducted at incident angles of 60° and 70°. This holistic approach sought to develop a comprehensive understanding of the performance of the GMR-based sensor under diverse operational conditions.
Collapse
Affiliation(s)
- Duy Thanh Cu
- Thin Film Technology Center, Department of Optics and Photonics, National Central University, 300, Chung Da Rd., Chung Li, Taoyuan 32001, Taiwan; (D.T.C.); (H.-W.W.)
| | - Hong-Wei Wu
- Thin Film Technology Center, Department of Optics and Photonics, National Central University, 300, Chung Da Rd., Chung Li, Taoyuan 32001, Taiwan; (D.T.C.); (H.-W.W.)
| | - Hung-Pin Chen
- National Applied Research Laboratories, Taiwan Instrument Research Institute, No. 20. R&D Rd. VI, Hsinchu Science Park, Hsinchu 30076, Taiwan;
| | - Li-Chen Su
- General Education Center, Ming Chi University of Technology, New Taipei 243303, Taiwan;
- Organic Electronics Research Center, Ming Chi University of Technology, New Taipei 243303, Taiwan
| | - Chien-Cheng Kuo
- Thin Film Technology Center, Department of Optics and Photonics, National Central University, 300, Chung Da Rd., Chung Li, Taoyuan 32001, Taiwan; (D.T.C.); (H.-W.W.)
| |
Collapse
|
3
|
Chiang CC, Tseng WC, Tsai WT, Huang CS. Handheld Biosensor System Based on a Gradient Grating Period Guided-Mode Resonance Device. BIOSENSORS 2023; 14:21. [PMID: 38248398 PMCID: PMC10813047 DOI: 10.3390/bios14010021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Revised: 12/20/2023] [Accepted: 12/29/2023] [Indexed: 01/23/2024]
Abstract
Handheld biosensors have attracted substantial attention for numerous applications, including disease diagnosis, drug dosage monitoring, and environmental sensing. This study presents a novel handheld biosensor based on a gradient grating period guided-mode resonance (GGP-GMR) sensor. Unlike conventional GMR sensors, the proposed sensor's grating period varies along the device length; hence, the resonant wavelength varies linearly along the device length. If a GGP-GMR sensor is illuminated with a narrow band of light at normal incidence, the light resonates and reflects at a specific period but transmits at other periods; this can be observed as a dark band by using a complementary metal oxide semiconductor (CMOS) underneath the sensor. The concentration of a target analyte can be determined by monitoring the shift of this dark band. We designed and fabricated a handheld device incorporating a light-emitting diode (LED) light source, the necessary optics, an optofluidic chip with an embedded GGP-GMR sensor, and a CMOS. LEDs with different beam angles and bandpass filters with different full width at half maximum values were investigated to optimize the dark band quality and improve the accuracy of the subsequent image analysis. Substrate materials with different refractive indices and waveguide thicknesses were also investigated to maximize the GGP-GMR sensor's figure of merit. Experiments were performed to validate the proposed handheld biosensor, which achieved a limit of detection (LOD) of 1.09 × 10-3 RIU for bulk solution measurement. The sensor's performance in the multiplexed detection of albumin and creatinine solutions at concentrations of 0-500 μg/mL and 0-10 mg/mL, respectively, was investigated; the corresponding LODs were 0.66 and 0.61 μg/mL.
Collapse
Affiliation(s)
| | | | | | - Cheng-Sheng Huang
- Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (C.C.C.); (W.-C.T.); (W.-T.T.)
| |
Collapse
|
4
|
Liu X, Zhang C, Hu J, Han H. Dual-band refractive index sensor with cascaded asymmetric resonant compound grating based on bound states in the continuum. OPTICS EXPRESS 2023; 31:13959-13969. [PMID: 37157270 DOI: 10.1364/oe.485867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
We propose a cascaded asymmetric resonant compound grating (ARCG) for high-performance dual-band refractive index sensing. The physical mechanism of the sensor is investigated using a combination of temporal coupled-mode theory (TCMT) and ARCG eigenfrequency information, which is verified by rigorous coupled-wave analysis (RCWA). The reflection spectra can be tailored by changing the key structural parameters. And by altering the grating strip spacing, a dual-band quasi-bound state in the continuum can be achieved. The simulation results show that the highest sensitivity of the dual-band sensor is 480.1 nm/RIU, and its figure of merit is 4.01 × 105. The proposed ARCG has potential application prospects for high-performance integrated sensors.
Collapse
|
5
|
Treebupachatsakul T, Shinnakerdchoke S, Pechprasarn S. Sensing Mechanisms of Rough Plasmonic Surfaces for Protein Binding of Surface Plasmon Resonance Detection. SENSORS (BASEL, SWITZERLAND) 2023; 23:3377. [PMID: 37050437 PMCID: PMC10098771 DOI: 10.3390/s23073377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 03/05/2023] [Accepted: 03/16/2023] [Indexed: 06/19/2023]
Abstract
Surface plasmon resonance (SPR) has been utilized in various optical applications, including biosensors. The SPR-based sensor is a gold standard for protein kinetic measurement due to its ultrasensitivity on the plasmonic metal surface. However, a slight change in the surface morphology, such as roughness or pattern, can significantly impact its performance. This study proposes a theoretical framework to explain sensing mechanisms and quantify sensing performance parameters of angular surface plasmon resonance detection for binding kinetic sensing at different levels of surface roughness. The theoretical investigation utilized two models, a protein layer coating on a rough plasmonic surface with and without sidewall coatings. The two models enable us to separate and quantify the enhancement factors due to the localized surface plasmon polaritons at sharp edges of the rough surfaces and the increased surface area for protein binding due to roughness. The Gaussian random surface technique was employed to create rough metal surfaces. Reflectance spectra and quantitative performance parameters were simulated and quantified using rigorous coupled-wave analysis and Monte Carlo simulation. These parameters include sensitivity, plasmonic dip position, intensity contrast, full width at half maximum, plasmonic angle, and figure of merit. Roughness can significantly impact the intensity measurement of binding kinetics, positively or negatively, depending on the roughness levels. Due to the increased scattering loss, a tradeoff between sensitivity and increased roughness leads to a widened plasmonic reflectance dip. Some roughness profiles can give a negative and enhanced sensitivity without broadening the SPR spectra. We also discuss how the improved sensitivity of rough surfaces is predominantly due to the localized surface wave, not the increased density of the binding domain.
Collapse
Affiliation(s)
- Treesukon Treebupachatsakul
- Department of Biomedical Engineering, School of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
| | - Siratchakrit Shinnakerdchoke
- Department of Biomedical Engineering, School of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
| | - Suejit Pechprasarn
- College of Biomedical Engineering, Rangsit University, Pathum Thani 12000, Thailand
| |
Collapse
|
6
|
Qian L, Gu T, Xu S, Zhang X, Wang K. Guided-mode resonance sensors with ultrahigh bulk sensitivity and figure of merit assisted by a metallic layer and structural symmetry-breaking. OPTICS EXPRESS 2023; 31:1844-1857. [PMID: 36785210 DOI: 10.1364/oe.479110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 12/10/2022] [Indexed: 06/18/2023]
Abstract
We propose a refractive index sensor with both high bulk sensitivity and figure of merit (FOM) that engages the guided-mode resonance (GMR) effect with the assistance of a metallic layer and structural symmetry-breaking in the grating layer. Owing to the existence of the metallic layer, the electric field at resonance can be reflected to the sensing environment, and enhanced bulk sensitivity is realized. Meanwhile, the full width at half maximum of the GMR mode can be decreased by increasing the asymmetrical degree of the grating, thus obtaining a high FOM which benefits the sensing resolution. A bulk refractive index sensitivity of 1076.7 nm/RIU and an FOM up to 35889 RIU-1 are achieved simultaneously. Other structural parameters such as the refractive index and fill factor of the grating are systematically discussed to optimize the sensing performance. The proposed GMR sensor with both high bulk sensitivity and FOM value has potential uses in applications with more stringent sensing requirements.
Collapse
|
7
|
Luo M, Zhou Y, Zhao X, Li Y, Guo Z, Yang X, Zhang M, Wang Y, Wu X. Label-Free Bound-States-in-the-Continuum Biosensors. BIOSENSORS 2022; 12:1120. [PMID: 36551087 PMCID: PMC9775062 DOI: 10.3390/bios12121120] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 11/29/2022] [Accepted: 11/30/2022] [Indexed: 06/03/2023]
Abstract
Bound states in the continuum (BICs) have attracted considerable attentions for biological and chemical sensing due to their infinite quality (Q)-factors in theory. Such high-Q devices with enhanced light-matter interaction ability are very sensitive to the local refractive index changes, opening a new horizon for advanced biosensing. In this review, we focus on the latest developments of label-free optical biosensors governed by BICs. These BICs biosensors are summarized from the perspective of constituent materials (i.e., dielectric, metal, and hybrid) and structures (i.e., grating, metasurfaces, and photonic crystals). Finally, the current challenges are discussed and an outlook is also presented for BICs inspired biosensors.
Collapse
Affiliation(s)
- Man Luo
- The Key Laboratory of Micro and Nano Photonic Structures, Department of Optical Science and Engineering, Fudan University, Shanghai 200438, China
| | - Yi Zhou
- The Key Laboratory of Micro and Nano Photonic Structures, Department of Optical Science and Engineering, Fudan University, Shanghai 200438, China
| | - Xuyang Zhao
- The Key Laboratory of Micro and Nano Photonic Structures, Department of Optical Science and Engineering, Fudan University, Shanghai 200438, China
| | - Yuxiang Li
- The Key Laboratory of Micro and Nano Photonic Structures, Department of Optical Science and Engineering, Fudan University, Shanghai 200438, China
| | - Zhihe Guo
- The Key Laboratory of Micro and Nano Photonic Structures, Department of Optical Science and Engineering, Fudan University, Shanghai 200438, China
| | - Xi Yang
- The Key Laboratory of Laser Device Technology, China North Industries Group Corporation Limited, Southwest Institute of Technical Physics, Chengdu 640041, China
| | - Meng Zhang
- The Key Laboratory of Laser Device Technology, China North Industries Group Corporation Limited, Southwest Institute of Technical Physics, Chengdu 640041, China
| | - You Wang
- The Key Laboratory of Laser Device Technology, China North Industries Group Corporation Limited, Southwest Institute of Technical Physics, Chengdu 640041, China
| | - Xiang Wu
- The Key Laboratory of Micro and Nano Photonic Structures, Department of Optical Science and Engineering, Fudan University, Shanghai 200438, China
| |
Collapse
|