1
|
Sukanya SD, Swamy BEK, Shashikumara JK, Sharma SC, Hariprasad SA. A novel, extreme low-cost poly (Erythrosine) modified pencil graphite electrode for determination of Adrenaline. Sci Rep 2023; 13:4523. [PMID: 36941302 PMCID: PMC10027675 DOI: 10.1038/s41598-023-31068-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 03/06/2023] [Indexed: 03/23/2023] Open
Abstract
A simple, novel, and less cost yellow (Erythrosine) modified pencil graphite electrode (Po-ERY/MGPE) was successfully fabricated via electropolymerization method using cyclic voltammetric techniques. The fabricated Po-ERY/MGPE opted as a sensor for the detection of Adrenaline (ADR) in 0.2 M PBS (7.4 pH). This reported senor displayed excellent electrocatalytic activity, increased sensitivity, high stability, superior electron transfer kinetics in the oxidation of ADR once relative to BGPE. The significance of pH, scan rate, and impact of concentration was assessed at the sensor. As per the pH and scan rate study, redox routes carry the same number of electrons and protons, and electro-oxidation of ADR was adsorption controlled respectively. The LOD of ADR was found to be 0.499 µM. The DPV data indicate that there is a significant peak divergence among ADR and uric acid (UA) which could make it easier to determine them alone and simultaneously on the sensor. The described method has been employed for the determination of ADR in injection sample. Good recovery values indicate the efficacy and applicability of the sensor in detecting ADR.
Collapse
Affiliation(s)
- S D Sukanya
- Department of P.G. Studies and Research in Analytical Chemistry, Alva's College, Moodubidire, Dakshina Kannada, Karnataka, 574227, India
| | - B E Kumara Swamy
- Department of P.G. Studies and Research in Industrial Chemistry, Kuvempu University, Jnana Sahyadri, Shankaraghatta, Shivmoga, Karnataka, 577451, India.
| | - J K Shashikumara
- Department of P.G. Studies and Research in Industrial Chemistry, Kuvempu University, Jnana Sahyadri, Shankaraghatta, Shivmoga, Karnataka, 577451, India
| | - S C Sharma
- National Assessment and Accreditation Council (Work Carried Out as Honorary Professor), Jain University, Bangalore, Karnataka, 560 069, India.
| | | |
Collapse
|
2
|
Zidarič T, Majer D, Maver T, Finšgar M, Maver U. The development of an electropolymerized, molecularly imprinted polymer (MIP) sensor for insulin determination using single-drop analysis. Analyst 2023; 148:1102-1115. [PMID: 36723087 DOI: 10.1039/d2an02025d] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
An electrochemical sensor for the detection of insulin in a single drop (50 μL) was developed based on the concept of molecularly imprinted polymers (MIP). The synthetic MIP receptors were assembled on a screen-printed carbon electrode (SPCE) by the electropolymerization of pyrrole (Py) in the presence of insulin (the protein template) using cyclic voltammetry. After electropolymerization, insulin was removed from the formed polypyrrole (Ppy) matrix to create imprinting cavities for the subsequent analysis of the insulin analyte in test samples. The surface characterization, before and after each electrosynthesis step of the MIP sensors, was performed using atomic force microscopy, scanning electron microscopy, and energy-dispersive X-ray spectroscopy. The performance of the developed MIP-SPCE sensor was evaluated using a single drop of solution containing K3Fe(CN)6 and the square-wave voltammetry technique. The MIP-SPCE showed a linear concentration range of 20.0-70.0 pM (R2 = 0.9991), a limit of detection of 1.9 pM, and a limit of quantification of 6.2 pM. The rapid response time to the protein target and the portability of the developed sensor, which is considered a disposable MIP-based system, make this MIP-SPCE sensor a promising candidate for point-of-care applications. In addition, the MIP-SPCE sensor was successfully used to detect insulin in a pharmaceutical sample. The sensor was deemed to be accurate (the average recovery was 108.46%) and precise (the relative standard deviation was 7.23%).
Collapse
Affiliation(s)
- Tanja Zidarič
- University of Maribor, Faculty of Medicine, Institute of Biomedical Sciences, Taborska ulica 8, 2000 Maribor, Slovenia
| | - David Majer
- University of Maribor, Faculty of Chemistry and Chemical Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia.
| | - Tina Maver
- University of Maribor, Faculty of Medicine, Institute of Biomedical Sciences, Taborska ulica 8, 2000 Maribor, Slovenia.,University of Maribor, Faculty of Medicine, Department of Pharmacology, Taborska ulica 8, 2000 Maribor, Slovenia
| | - Matjaž Finšgar
- University of Maribor, Faculty of Chemistry and Chemical Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia.
| | - Uroš Maver
- University of Maribor, Faculty of Medicine, Institute of Biomedical Sciences, Taborska ulica 8, 2000 Maribor, Slovenia.,University of Maribor, Faculty of Medicine, Department of Pharmacology, Taborska ulica 8, 2000 Maribor, Slovenia
| |
Collapse
|
3
|
Majer D, Finšgar M. An l-cysteic acid-modified screen-printed carbon electrode for methyl parathion determination. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
4
|
Electrochemical Sensing of Epinephrine on a Carbon Nanofibers and Gold Nanoparticle-Modified Electrode. Electrocatalysis (N Y) 2022. [DOI: 10.1007/s12678-022-00769-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|