1
|
Xie Y, Li Y, Lin H, Wang X, Liao W, Liu Z, Lin L. Real-Time pH Sensor in Bacterial Microenvironments Using Liquid Crystal Core-Shell Microspheres. Anal Chem 2024; 96:11472-11478. [PMID: 38957093 DOI: 10.1021/acs.analchem.4c02040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/04/2024]
Abstract
It is well-known that the bacterial microenvironment imposes restrictions on the growth and behavior of bacteria. The localized monitoring of microenvironmental factors is appreciated when consulting bacterial adaptation and behavior in the presence of chemical or mechanical stimuli. Herein, we developed a novel liquid crystal (LC) biosensor in a microsphere configuration for real-time 3D monitoring of the bacteria microenvironment, which was implemented by a microfluidic chip. As a proof of concept, a LC gel (LC-Gel) microsphere biosensor was prepared and employed in the localized pH changes of bacteria by observing the configuration change of LC under polarized optical microscopy. Briefly, the microsphere biosensor was constructed in core-shell configuration, wherein the core contained LCE7 (a nematic LC) doped with 4-pentylbiphenyl-4'-carboxylic acid (PBA), and the shell encapsulated the bacteria. The protonation of carboxyl functional groups of the PBA induced a change in charge density on the surface of LCE7 and the orientation of E7 molecules, resulting in the transitions of the LC nucleus from axial to bipolar. The developed LC-Gel microspheres pH sensor exhibited its dominant performance on localized pH real-time sensing with a resolution of 0.1. An intriguing observation from the prepared pH biosensor was that the diverse bacteria impelled distinct acidifying or alkalizing effects. Overall, the facile LC-Gel microsphere biosensor not only provides a versatile tool for label-free, localized pH monitoring but also opens avenues for investigating the effects of chemical and mechanical stimuli on cellular metabolism within bacterial microenvironments.
Collapse
Affiliation(s)
- Yaoshuang Xie
- MOE Key Laboratory of Geriatric Nutrition and Health, Department of Bioengineering, Beijing Technology and Business University, Beijing 100048, China
| | - Yuxuan Li
- Beijing Key Laboratory of Microanalytical Methods and Instrumentation, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Haifeng Lin
- MOE Key Laboratory of Geriatric Nutrition and Health, Department of Bioengineering, Beijing Technology and Business University, Beijing 100048, China
| | - Xiaorui Wang
- MOE Key Laboratory of Geriatric Nutrition and Health, Department of Bioengineering, Beijing Technology and Business University, Beijing 100048, China
| | - Wenjun Liao
- MOE Key Laboratory of Geriatric Nutrition and Health, Department of Bioengineering, Beijing Technology and Business University, Beijing 100048, China
| | - Zeyang Liu
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California 90095, United States
| | - Ling Lin
- MOE Key Laboratory of Geriatric Nutrition and Health, Department of Bioengineering, Beijing Technology and Business University, Beijing 100048, China
| |
Collapse
|
2
|
Das S, Sil S, Pal SK, Kula P, Sinha Roy S. Label-free liquid crystal-based optical detection of norfloxacin using an aptamer recognition probe in soil and lake water. Analyst 2024; 149:3828-3838. [PMID: 38855814 DOI: 10.1039/d4an00236a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2024]
Abstract
Norfloxacin (NOX), a broad spectrum fluoroquinolone (FQ) antibiotic, is commonly detected in environmental residues, potentially contributing to biological drug resistance. In this paper, an aptamer recognition probe has been used to develop a label-free liquid crystal-based biosensor for simple and robust optical detection of NOX in aqueous solutions. Stimuli-receptive liquid crystals (LCs) have been employed to report aptamer-target binding events at the LC-aqueous interface. The homeotropic alignment of LCs at the aqueous-LC interface is due to the self-assembly of the cationic surfactant cetyltrimethylammonium bromide (CTAB). In the presence of the negatively charged NOX aptamer, the ordering changes to planar/tilted. On addition of NOX, the aptamer-NOX binding causes redistribution of CTAB at the LC-aqueous interface and the homeotropic orientation is restored. This results in a bright-to-dark optical transition under a polarized optical microscope (POM). This optical transition serves as a visual indicator to mark the presence of NOX. The devised aptasensor demonstrates high specificity with a minimum detection limit of 5 nM (1.596 ppb). Moreover, the application of the developed aptasensor for the detection of NOX in freshwater and soil samples underscores its practical utility in environmental monitoring. This proposed LC-based method offers several advantages over conventional detection techniques for a rapid, feasible and convenient way to detect norfloxacin.
Collapse
Affiliation(s)
- Sayani Das
- Nanocarbon and Sensor Laboratory, Department of Physics, School of Natural Sciences, Shiv Nadar Institution of Eminence, Gautam Buddha Nagar, Greater Noida, India.
| | - Soma Sil
- Department of Chemical Sciences, Indian Institute of Science Education and Research Mohali, Mohali, India
| | - Santanu Kumar Pal
- Department of Chemical Sciences, Indian Institute of Science Education and Research Mohali, Mohali, India
| | - Przemysław Kula
- Institute of Chemistry, Military University of Technology, Warsaw, Poland
| | - Susanta Sinha Roy
- Nanocarbon and Sensor Laboratory, Department of Physics, School of Natural Sciences, Shiv Nadar Institution of Eminence, Gautam Buddha Nagar, Greater Noida, India.
| |
Collapse
|
3
|
Wang H, Fan Y, Wang H, Chen Z, Yu S, Hou X. Visual Biosensing with Specific Liquid-Based Interface Behaviors. ACS NANO 2024; 18:7327-7333. [PMID: 38407020 DOI: 10.1021/acsnano.3c08396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/27/2024]
Abstract
Liquid-based interface behaviors at micro/nano or even smaller scales induced by biomolecules take us into a fascinating realm, fostering a deeper understanding and innovation in visual biosensing. This biosensing technology, grounded in specific liquid-based interface behaviors, redefines how diseases can be detected, monitored, and diagnosed in resource-limited settings, providing rapid, cost-effective, and self-testing solutions to the current healthcare landscape. To date, the technology has witnessed significant advancements in visual sensing, driven by diverse liquid-based materials, advanced nanomanufacturing techniques, and a profound understanding of interface-material interactions. In this Perspective, we discuss and elucidate the interface biosensing mechanisms arising from three types, including liquid-solid, liquid-liquid, and liquid-gas interfaces, and we provide insights into the challenges and future development of visual biosensing applications.
Collapse
Affiliation(s)
- Huimeng Wang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, People's Republic of China
| | - Yi Fan
- State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, People's Republic of China
| | - Hui Wang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, People's Republic of China
| | - Zemin Chen
- State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, People's Republic of China
| | - Shijie Yu
- State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, People's Republic of China
| | - Xu Hou
- State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, People's Republic of China
- Department of Physics, Research Institute for Biomimetics and Soft Matter, Fujian Provincial Key Laboratory for Soft Functional Materials Research, Jiujiang Research Institute, College of Physical Science and Technology, Xiamen University, Xiamen 361005, People's Republic of China
- Innovation Laboratory for Sciences and Technologies of Energy Materials of Fujian Province (IKKEM), Xiamen 361102, People's Republic of China
| |
Collapse
|
4
|
Piven A, Darmoroz D, Skorb E, Orlova T. Machine learning methods for liquid crystal research: phases, textures, defects and physical properties. SOFT MATTER 2024; 20:1380-1391. [PMID: 38288719 DOI: 10.1039/d3sm01634j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/15/2024]
Abstract
Liquid crystal materials, with their unique properties and diverse applications, have long captured the attention of researchers and industries alike. From liquid crystal displays and electro-optical devices to advanced sensors and emerging technologies, the study and application of liquid crystals continue to be of paramount importance in the fields of materials science, chemistry and physics. With the ever-increasing complexity and diversity of liquid crystal materials, researchers face new challenges in understanding their behaviors, properties, and potential applications. On the other hand, machine learning, a rapidly evolving interdisciplinary field at the intersection of computer science and data analysis, has already become a powerful tool for unraveling implicit correlations and predicting new properties of a wide variety of physical and chemical systems and structures. Here we aim to consider how machine learning methods are suitable for solving fundamental problems in the field of liquid crystals and what are the advantages of this artificial intelligence based approach.
Collapse
Affiliation(s)
- Anastasiia Piven
- Infochemistry Scientific Center, ITMO University, Saint-Petersburg, Russia.
| | - Darina Darmoroz
- Infochemistry Scientific Center, ITMO University, Saint-Petersburg, Russia.
| | - Ekaterina Skorb
- Infochemistry Scientific Center, ITMO University, Saint-Petersburg, Russia.
| | - Tetiana Orlova
- Infochemistry Scientific Center, ITMO University, Saint-Petersburg, Russia.
| |
Collapse
|
5
|
Peng Z, Chen J, Liu Y, Li D, Li Y, Zhang Q, Chen C, Zhang Y, Yao J, Wang S, Lin Q, Ruan Y. Optical biosensor based on weak measurement for ultra-sensitive detection of calreticulin in human serum. BIOMEDICAL OPTICS EXPRESS 2024; 15:715-724. [PMID: 38404297 PMCID: PMC10890857 DOI: 10.1364/boe.514443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 12/27/2023] [Accepted: 01/03/2024] [Indexed: 02/27/2024]
Abstract
A novel real-time optical phase sensing method based on the Mach-Zehnder interference principle has been proposed for the detection of calreticulin (CRT) levels in human serum samples. In this approach, anti-CRT antibodies are utilized to capture CRT molecules in serum, leading to a phase shift in both the measuring and reference arms of the system. By employing the concept of weak amplification within the framework of weak measurements, it becomes feasible to continuously monitor the response of CRT in real-time, allowing for the precise determination of serum CRT content at the picomolar level. Our achievement may pave the way in establishing CRT as a diagnostic biomarker for a wide range of medical applications, including rheumatoid arthritis.
Collapse
Affiliation(s)
- Zhikang Peng
- Key Laboratory of Quantum Precision Measurement of Zhejiang Province, Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Jiali Chen
- Key Laboratory of Quantum Precision Measurement of Zhejiang Province, Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Yufei Liu
- Key Laboratory of Quantum Precision Measurement of Zhejiang Province, Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Dongmei Li
- Key Laboratory of Quantum Precision Measurement of Zhejiang Province, Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Yixiao Li
- Key Laboratory of Quantum Precision Measurement of Zhejiang Province, Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Qihao Zhang
- Key Laboratory of Quantum Precision Measurement of Zhejiang Province, Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Chaoyi Chen
- Key Laboratory of Quantum Precision Measurement of Zhejiang Province, Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Ying Zhang
- Department of Endocrinology and Metabolism, Shaoxing Second Hospital, Shaoxing 312000, China
| | - Jia Yao
- Department of Breast Surgery, the First Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 311121, China
| | - Shuqian Wang
- Department of Breast Surgery, the First Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 311121, China
| | - Qiang Lin
- Key Laboratory of Quantum Precision Measurement of Zhejiang Province, Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Yi Ruan
- Key Laboratory of Quantum Precision Measurement of Zhejiang Province, Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| |
Collapse
|
6
|
Shadkami R, Chan PK. Computational Analysis on the Performance of Elongated Liquid Crystal Biosensors. MICROMACHINES 2023; 14:1831. [PMID: 37893268 PMCID: PMC10609392 DOI: 10.3390/mi14101831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 09/18/2023] [Accepted: 09/21/2023] [Indexed: 10/29/2023]
Abstract
Elongated ellipsoidal liquid crystal microdroplet reorientation dynamics are discussed in this paper for biosensor applications. To investigate the effect of elongated droplets on nematic liquid crystal droplet biosensors, we simulated a model of a liquid crystal droplet using ellipse geometry. Director reorientation is examined in relation to the elongated droplet shape. In addition, we examined aspect ratio as a factor affecting biosensor response time in relation to surface viscosity and anchoring energy. Finally, the findings suggest that the aspect ratio should be taken into account when designing biosensors. These results can be used to develop more effective biosensors for a variety of applications. This model then predicts the director reorientation angle, which is dependent on the anchoring energy and surface viscosity. This model further suggests that both surface viscosity and homeotropic anchoring energy play an important role when it comes to the director reorientation angle. We developed and applied a nonlinear unsteady-state mathematical model utilizing torque balance and Frank free energy according to the Leslie-Ericksen continuum theory for simulating elongated nematic liquid crystal biosensor droplets with aqueous interfaces. Using the Euler-Lagrange equation, a transient liquid crystal-aqueous interface realignment is modeled by changing the easy axis when surfactant molecules are added to the interface. The realignment at the surface of the droplet is assumed to be driven by the effect of the surfactant, which causes an anchoring transition. According to the results, the response time of the biosensor depends on the aspect ratio. Therefore, the elongation has the potential to control biosensing response time. The result of our study provides a better understanding of director reorientation in elongated liquid crystal droplets in biosensing applications through the numerical results which are presented in this paper.
Collapse
Affiliation(s)
| | - Philip K. Chan
- Department of Chemical Engineering, Toronto Metropolitan University, 350 Victoria Street, Toronto, ON M5B 2K3, Canada;
| |
Collapse
|
7
|
Pourasl MH, Vahedi A, Tajalli H, Khalilzadeh B, Bayat F. Liquid crystal-assisted optical biosensor for early-stage diagnosis of mammary glands using HER-2. Sci Rep 2023; 13:6847. [PMID: 37100835 PMCID: PMC10133346 DOI: 10.1038/s41598-023-31668-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Accepted: 03/15/2023] [Indexed: 04/28/2023] Open
Abstract
Breast cancer (BC) is one of the most commonly diagnosed cancers and the second leading cause of cancer mortality among women around the world. The purpose of this study is to present a non-labeled liquid crystal (LC) biosensor, based on the inherent feature of nematic LCs, for the evaluation of BC using the human epidermal growth factor receptor-2 (HER-2) biomarker. The mechanism of this sensing is supported by surface modification with dimethyloctadecyl [3-(trimethoxysilyl) propyl] ammonium chloride (DMOAP) encouraging the long alkyl chains that induce a homeotropic orientation of the LC molecules at the interface. To enhance the binding efficacy of more HER-2 antibody (Ab) on LC aligning agents, a simple ultraviolet radiation-assisted method was also used to increase functional groups on the DMOAP coated slides, thereby improving binding affinity and efficiency onto HER-2 Abs. The designed biosensor makes use of the specific binding of HER-2 protein to HER-2 Ab and disruption of the orientation of LCs. This orientation change leads to a transition of the optical appearance from dark to birefringent, enabling the detection of HER-2. This novel biosensor exhibits a linear optical response to HER-2 concentration in the wide dynamic range of 10-6-102 ng/mL, with an ultra-low detection limit of 1 fg/mL. As a proof of concept, the designed LC biosensor was successfully investigated for the quantification of HER-2 protein in patients suffering from BC. Owing to the sensitivity, selectivity, and label-free detection, this biosensor may amplify the application of LC-based biosensors for the detection of most types of cancers.
Collapse
Affiliation(s)
- Mehri H Pourasl
- Department of Physics, Tabriz Branch, Islamic Azad University, Tabriz, Iran
- Biophotonic Research Center, Tabriz Branch, Islamic Azad University, Tabriz, Iran
| | - Ali Vahedi
- Department of Physics, Tabriz Branch, Islamic Azad University, Tabriz, Iran.
| | - Habib Tajalli
- Department of Physics, Tabriz Branch, Islamic Azad University, Tabriz, Iran
- Biophotonic Research Center, Tabriz Branch, Islamic Azad University, Tabriz, Iran
| | - Balal Khalilzadeh
- Stem Cell Research Center (SCRC), Tabriz University of Medical Sciences, Tabriz, 51664-14766, Iran.
| | - Farzaneh Bayat
- Department of Physics, Azarbaijan Shahid Madani University, Tabriz, Iran
| |
Collapse
|
8
|
Duong DST, Jang CH. Detection of phosphatidylserine by using liquid crystal supported on the gold-deposited waveform surfaces with the annexin V-based signal enhancement. Microchem J 2023. [DOI: 10.1016/j.microc.2022.108176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
9
|
Rouhbakhsh Z, Huang JW, Ho TY, Chen CH. Liquid crystal-based chemical sensors and biosensors: From sensing mechanisms to the variety of analytical targets. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|