1
|
Kumar DR, Banaś A, Krukiewicz K. Challenges and Advances in Biomarker Detection for Rapid and Accurate Sepsis Diagnosis: An Electrochemical Approach. BIOSENSORS 2024; 14:309. [PMID: 38920613 PMCID: PMC11202072 DOI: 10.3390/bios14060309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 06/09/2024] [Accepted: 06/11/2024] [Indexed: 06/27/2024]
Abstract
Sepsis is a life-threatening condition with high mortality rates due to delayed treatment of patients. The conventional methodology for blood diagnosis takes several hours, which suspends treatment, limits early drug administration, and affects the patient's recovery. Thus, rapid, accurate, bedside (onsite), economical, and reliable sepsis biomarker reading of the clinical sample is an emergent need for patient lifesaving. Electrochemical label-free biosensors are specific and rapid devices that are able to perform analysis at the patient's bedside; thus, they are considered an attractive methodology in a clinical setting. To reveal their full diagnostic potential, electrode architecture strategies of fabrication are highly desirable, particularly those able to preserve specific antibody-antigen attraction, restrict non-specific adsorption, and exhibit high sensitivity with a low detection limit for a target biomarker. The aim of this review is to provide state-of-the-art methodologies allowing the fabrication of ultrasensitive and highly selective electrochemical sensors for sepsis biomarkers. This review focuses on different methods of label-free biomarker sensors and discusses their advantages and disadvantages. Then, it highlights effective ways of avoiding false results and the role of molecular labels and functionalization. Recent literature on electrode materials and antibody grafting strategies is discussed, and the most efficient methodology for overcoming the non-specific attraction issues is listed. Finally, we discuss the existing electrode architecture for specific biomarker readers and promising tactics for achieving quick and low detection limits for sepsis biomarkers.
Collapse
Affiliation(s)
- Deivasigamani Ranjith Kumar
- Centre for Organic and Nanohybrid Electronics, Silesian University of Technology, Konarskiego 22B, 44-100 Gliwice, Poland;
| | - Angelika Banaś
- Department of Physical Chemistry and Technology of Polymers, Silesian University of Technology, M. Strzody 9, 44-100 Gliwice, Poland;
| | - Katarzyna Krukiewicz
- Centre for Organic and Nanohybrid Electronics, Silesian University of Technology, Konarskiego 22B, 44-100 Gliwice, Poland;
- Department of Physical Chemistry and Technology of Polymers, Silesian University of Technology, M. Strzody 9, 44-100 Gliwice, Poland;
| |
Collapse
|
2
|
Echeverri D, Calucho E, Marrugo-Ramírez J, Álvarez-Diduk R, Orozco J, Merkoçi A. Capacitive immunosensing at gold nanoparticle-decorated reduced graphene oxide electrodes fabricated by one-step laser nanostructuration. Biosens Bioelectron 2024; 252:116142. [PMID: 38401281 DOI: 10.1016/j.bios.2024.116142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 02/01/2024] [Accepted: 02/18/2024] [Indexed: 02/26/2024]
Abstract
Nanostructured electrochemical biosensors have ushered in a new era of diagnostic precision, offering enhanced sensitivity and specificity for clinical biomarker detection. Among them, capacitive biosensing enables ultrasensitive label-free detection of multiple molecular targets. However, the complexity and cost associated with conventional fabrication methods of nanostructured platforms hinder the widespread adoption of these devices. This study introduces a capacitive biosensor that leverages laser-engraved reduced graphene oxide (rGO) electrodes decorated with gold nanoparticles (AuNPs). The fabrication involves laser-scribed GO-Au3+ films, yielding rGO-AuNP electrodes, seamlessly transferred onto a PET substrate via a press-stamping methodology. These electrodes have a remarkable affinity for biomolecular recognition after being functionalized with specific bioreceptors. For example, initial studies with human IgG antibodies confirm the detection capabilities of the biosensor using electrochemical capacitance spectroscopy. Furthermore, the biosensor can quantify CA-19-9 glycoprotein, a clinical cancer biomarker. The biosensor exhibits a dynamic range from 0 to 300 U mL-1, with a limit of detection of 8.9 U mL-1. Rigorous testing with known concentrations of a pretreated CA-19-9 antigen from human fluids confirmed their accuracy and reliability in detecting the glycoprotein. This study signifies notable progress in capacitive biosensing for clinical biomarkers, potentially leading to more accessible and cost-effective point-of-care solutions.
Collapse
Affiliation(s)
- Danilo Echeverri
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), CSIC and the Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193, Barcelona, Spain; Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, 050010, Medellín, Colombia
| | - Enric Calucho
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), CSIC and the Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193, Barcelona, Spain; Universitat Autònoma de Barcelona (UAB), Bellaterra, 08193, Barcelona, Spain
| | - Jose Marrugo-Ramírez
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), CSIC and the Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193, Barcelona, Spain; Universitat Autònoma de Barcelona (UAB), Bellaterra, 08193, Barcelona, Spain
| | - Ruslán Álvarez-Diduk
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), CSIC and the Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193, Barcelona, Spain.
| | - Jahir Orozco
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, 050010, Medellín, Colombia.
| | - Arben Merkoçi
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), CSIC and the Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193, Barcelona, Spain; ICREA Institució Catalana de Recerca i Estudis Avançats, Passeig de Lluís Companys, 23, 08010, Barcelona, Spain.
| |
Collapse
|
3
|
Malecka-Baturo K, Daniels M, Dehaen W, Radecka H, Radecki J, Grabowska I. Voltammetric Sensing of Chloride Based on a Redox-Active Complex: A Terpyridine-Co(II)-Dipyrromethene Functionalized Anion Receptor Deposited on a Gold Electrode. Molecules 2024; 29:2102. [PMID: 38731593 PMCID: PMC11085611 DOI: 10.3390/molecules29092102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/16/2024] [Accepted: 04/29/2024] [Indexed: 05/13/2024] Open
Abstract
A redox-active complex containing Co(II) connected to a terpyridine (TPY) and dipyrromethene functionalized anion receptor (DPM-AR) was created on a gold electrode surface. This host-guest supramolecular system based on a redox-active layer was used for voltammetric detection of chloride anions in aqueous solutions. The sensing mechanism was based on the changes in the redox activity of the complex observed upon binding of the anion to the receptor. The electron transfer coefficient (α) and electron transfer rate constant (k0) for the modified gold electrodes were calculated based on Cyclic Voltammetry (CV) experiments results. On the other hand, the sensing abilities were examined using Square Wave Voltammetry (SWV). More importantly, the anion receptor was selective to chloride, resulting in the highest change in Co(II) current intensity and allowing to distinguish chloride, sulfate and bromide. The proposed system displayed the highest sensitivity to Cl- with a limit of detection of 0.50 fM. The order of selectivity was: Cl- > SO42- > Br-, which was confirmed by the binding constants (K) and reaction coupling efficiencies (RCE).
Collapse
Affiliation(s)
- Kamila Malecka-Baturo
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Street 10, 10-748 Olsztyn, Poland; (K.M.-B.); (H.R.)
| | - Mathias Daniels
- Sustainable Chemistry for Metals and Molecules, Department of Chemistry, KU Leuven, Leuven Chem&Tech, Celestijnenlaan 200F, B-3001 Leuven, Belgium (W.D.)
| | - Wim Dehaen
- Sustainable Chemistry for Metals and Molecules, Department of Chemistry, KU Leuven, Leuven Chem&Tech, Celestijnenlaan 200F, B-3001 Leuven, Belgium (W.D.)
| | - Hanna Radecka
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Street 10, 10-748 Olsztyn, Poland; (K.M.-B.); (H.R.)
| | - Jerzy Radecki
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Street 10, 10-748 Olsztyn, Poland; (K.M.-B.); (H.R.)
| | - Iwona Grabowska
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Street 10, 10-748 Olsztyn, Poland; (K.M.-B.); (H.R.)
| |
Collapse
|
4
|
Li S, Zhang Y, Guo M, Yi Z, Hu M, Xiong C, Huang G, Zhang J. Rapid detection of Salmonella in milk by labeling-free electrochemical immunosensor based on an Fe 3O 4-ionic liquid-modified electrode. Talanta 2024; 270:125576. [PMID: 38147723 DOI: 10.1016/j.talanta.2023.125576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Revised: 12/15/2023] [Accepted: 12/19/2023] [Indexed: 12/28/2023]
Abstract
Electrochemical sensors show distinct advantages over other types of sensors in the rapid detection of microorganisms. Here, we attempted to construct a label-free electrochemical immunosensor based on an Fe3O4-ionic liquid (IL)-modified electrode to rapidly detect Salmonella in milk. The excellent ionic conductivity of the IL facilitated sensor construction, and the large surface area of nano-Fe3O4 provided numerous sites for subsequent experiments. An antibody was fixed on the Fe3O4-IL complex with polyglutamic acid modification by a simple infusion method. The microstructure of the Fe3O4-IL composites was investigated by scanning electron microscopy, and the elements and structures of the composites were analyzed by energy dispersive X-ray and Fourier transform infrared spectroscopy. Under optimized experimental conditions, the detection range of the constructed sensor was 3.65 × 102-3.65 × 108 CFU mL-1, and the LOD was 1.12 × 102 CFU mL-1 (S/N = 3). In addition, the prepared electrochemical immunosensor is convenient for detecting foodborne pathogens because of its outstanding stability, good selectivity, and repeatability.
Collapse
Affiliation(s)
- Shuang Li
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Yu Zhang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Mengdi Guo
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Zhibin Yi
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Mengna Hu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Chunhong Xiong
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Ganhui Huang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Jinsheng Zhang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China.
| |
Collapse
|
5
|
Mobed A, Darvishi M, Tahavvori A, Alipourfard I, Kohansal F, Ghazi F, Alivirdiloo V. Nanobiosensors for procalcitonin (PCT) analysis. J Clin Lab Anal 2024; 38:e25006. [PMID: 38268233 PMCID: PMC10873684 DOI: 10.1002/jcla.25006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Revised: 12/18/2023] [Accepted: 01/07/2024] [Indexed: 01/26/2024] Open
Abstract
BACKGROUND Procalcitonin (PCT) is a critical biomarker that is released in response to bacterial infections and can be used to differentiate the pathogenesis of the infectious process. OBJECTIVE In this article, we provide an overview of recent advances in PCT biosensors, highlighting different approaches for biosensor construction, different immobilization methods, advantages and roles of different matrices used, analytical performance, and PCT biosensor construction. Also, we will explain PCT biosensors sensible limits of detection (LOD), linearity, and other analytical characteristics. Future prospects for the development of better PCT biosensor systems are also discussed. METHODS Traditional methods such as capillary electrophoresis, high-performance liquid chromatography, and mass spectrometry are effective in analyzing PCT in the medical field, but they are complicated, time-consuming sample preparation, and require expensive equipment and skilled personnel. RESULTS In the past decades, PCT biosensors have emerged as simple, fast, and sensitive tools for PCT analysis in various fields, especially medical fields. CONCLUSION These biosensors have the potential to accompany or replace traditional analytical methods by simplifying or reducing sample preparation and making field testing easier and faster, while significantly reducing the cost per analysis.
Collapse
Affiliation(s)
- Ahmad Mobed
- Infectious and Tropical Diseases Research Center, Clinical Research InstituteTabriz University of Medical SciencesTabrizIran
| | - Mohammad Darvishi
- Infectious Diseases and Tropical Medicine Research Center (IDTMRC), Department of Aerospace and Subaquatic MedicineAJA University of Medical SciencesTehranIran
| | - Amir Tahavvori
- Internal Department, Medical FacultyUrmia University of Medical SciencesUrmiaIran
| | - Iraj Alipourfard
- Institute of Biology, Biotechnology and Environmental Protection, Faculty of Natural SciencesTehran University of Medical SciencesTehranIran
| | - Fereshteh Kohansal
- Infectious and Tropical Diseases Research Center, Clinical Research InstituteTabriz University of Medical SciencesTabrizIran
- Stem Cell Research CenterTabriz University of Medical SciencesTabrizIran
| | - Farhood Ghazi
- Ramsar CampusMazandaran University of Medical SciencesRamsarIran
| | | |
Collapse
|
6
|
A Sensitive and Selective Electrochemical Aptasensor Based On Gold Nanoflower/Polyethyleneimine (Pei)-Functionalized Metal Organic Framework Nanocomposites for Label-Free Determination of Streptomycin in Milk Samples. FOOD ANAL METHOD 2023. [DOI: 10.1007/s12161-023-02446-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|