1
|
Rayhan MSA, Talukder A, Rani S, Easin KB, Hossain MA, Biswas PC. Visible diffuse reflectance smartphone spectrometer with high spectral accuracy. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 326:125240. [PMID: 39378831 DOI: 10.1016/j.saa.2024.125240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 09/11/2024] [Accepted: 09/30/2024] [Indexed: 10/10/2024]
Abstract
A smartphone-based spectrometer employing principle of diffuse reflection is reported for the surface analysis of solid samples. The instrument utilizes a thin-film grating to diffract incoming light, while a diffuse reflecting surface projects the image of this diffracted light onto the detector plane. The CMOS camera of smartphone camera directly captures the diffusely reflected photons within its limited field-of-view thus eliminating the need for collection, conditioning and converging optics. The optical setup of the instrument provides facility to calibrate the spectral response considering the nonlinear distribution of the wavelength across the diffraction direction. Additional correction in the detector response at different light intensity results a reduced spectral error with a maximum wavelength resolution of δλ=0.08 nm/pixel in the camera within the spectral range Δλ = (400 - 700) nm. As a proof of the concept, the instrument demonstrates successful detection of color pigments in food samples by absorption measurement of the samples at an average spectral error < 6 %. The distinct absorption peak associated with standard food colors are compared against the absorption profile of unknown food colors used in pastry cake. This field-functional smart analysis with internet connectivity opens opportunity of identifying food adulteration by using toxic chemical colors at the point-of-test and immediate reporting to others. The overall instrument is fabricated by utilizing low-cost and light weight plastic wood to make compact (110 mm × 105 mm × 125 mm), robust, inexpensive (∼$ 50) and suitable for field-portable (∼145 gm) hand-held operation.
Collapse
Affiliation(s)
- Md Sadik Al Rayhan
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Arnab Talukder
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Saptami Rani
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Khaled Bin Easin
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Md Arafat Hossain
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Protik Chandra Biswas
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh.
| |
Collapse
|
2
|
Park J. Smartphone based lateral flow immunoassay quantifications. J Immunol Methods 2024; 533:113745. [PMID: 39173705 DOI: 10.1016/j.jim.2024.113745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Revised: 07/21/2024] [Accepted: 08/19/2024] [Indexed: 08/24/2024]
Abstract
Lateral Flow Immunoassay (LFI) is a disposable tool designed to detect target substances using minimal resources. For qualitative analysis, LFI does not require a device (i.e., reader) to interpret test results. However, various studies have been conducted to implement quantitative analysis using LFI systems, incorporating LFI along with electrical/electronic readers, to overcome the limitations associated with qualitative LFI analysis. The reader used for the quantitative analysis of LFI should ensure mobility for easy on-site diagnostics and inspections, be user-friendly in operation, and have a fast processing speed until the results are obtained. Due to these requirements, smartphones are increasingly utilized as readers in quantitative analysis of LFI. Among the various components constituting a smartphone, high-performance cameras can serve as sensors converting visual signals into electrical signals. With powerful processing units, large storage capacity, and network capabilities for transmitting analysis results, smartphones are also utilized as interfaces for quantitative analysis. Absolutely, the widespread global use of smartphones is a key advantage, leading to their utilization as diagnostic devices for acquiring, analyzing, storing, and transmitting assay test results. This paper summarizes research cases where smartphones are utilized as readers for quantitative LFI systems used in confirming contamination in food or the environment, detecting drugs, and diagnosing diseases in humans or animals. The systems are classified based on the types of label particles used in the assay, and efforts to improve the quantitative analysis performance for each are examined. Cases where smartphones were used as LFI readers for the diagnosis of the 2019 Coronavirus Disease (COVID-19), which has recently caused significant global damage, have also been investigated.
Collapse
Affiliation(s)
- Jongwon Park
- Department of Biomedical Engineering, Kyungil University, Gyeongsan 38428, Republic of Korea.
| |
Collapse
|
3
|
Bezinge L, Shih CJ, Richards DA, deMello AJ. Electrochemical Paper-Based Microfluidics: Harnessing Capillary Flow for Advanced Diagnostics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2401148. [PMID: 38801400 DOI: 10.1002/smll.202401148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 04/29/2024] [Indexed: 05/29/2024]
Abstract
Electrochemical paper-based microfluidics has attracted much attention due to the promise of transforming point-of-care diagnostics by facilitating quantitative analysis with low-cost and portable analyzers. Such devices harness capillary flow to transport samples and reagents, enabling bioassays to be executed passively. Despite exciting demonstrations of capillary-driven electrochemical tests, conventional methods for fabricating electrodes on paper impede capillary flow, limit fluidic pathways, and constrain accessible device architectures. This account reviews recent developments in paper-based electroanalytical devices and offers perspective by revisiting key milestones in lateral flow tests and paper-based microfluidics engineering. The study highlights the benefits associated with electrochemical sensing and discusses how the detection modality can be leveraged to unlock novel functionalities. Particular focus is given to electrofluidic platforms that embed electrodes into paper for enhanced biosensing applications. Together, these innovations pave the way for diagnostic technologies that offer portability, quantitative analysis, and seamless integration with digital healthcare, all without compromising the simplicity of commercially available rapid diagnostic tests.
Collapse
Affiliation(s)
- Léonard Bezinge
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Chih-Jen Shih
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Daniel A Richards
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Andrew J deMello
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| |
Collapse
|
4
|
Kourentzi K, Brosamer K, Vu B, Willson RC. Accelerated Development of a COVID-19 Lateral Flow Test in an Academic Setting: Lessons Learned. Acc Chem Res 2024; 57:1372-1383. [PMID: 38590049 PMCID: PMC11080997 DOI: 10.1021/acs.accounts.4c00075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 03/26/2024] [Accepted: 03/29/2024] [Indexed: 04/10/2024]
Abstract
The COVID-19 pandemic further demonstrated the need for usable, reliable, and cost-effective point-of-care diagnostics that can be broadly deployed, ideally for self-testing at home. Antigen tests using more-detectable reporter labels (usually at the cost of reader complexity) achieve better diagnostic sensitivity, supporting the value of higher-analytical-sensitivity reporter technologies in lateral flow.We developed a new approach to simple, inexpensive lateral flow assays (LFAs) of great sensitivity, based on the glow stick peroxyoxalate chemistry widely used in emergency settings and in children's toys. At the peak of the COVID-19 pandemic, we had the opportunity to participate in the pandemic-driven NIH Rapid Acceleration of Diagnostics (RADx) initiative aiming to develop a deployable lateral flow diagnostic for SARS-CoV-2 nucleoprotein based on our novel glow stick-inspired light-emitting reporter technology. During this project, we screened more than 250 antibody pairs for analytical sensitivity and specificity directly in LFA format, using recombinant nucleoprotein and then gamma-irradiated virions spiked into negative nasal swab extracts. Membranes and other LFA materials and swabs and extraction reagent components also were screened and selected. Optimization of conjugate preparation and spraying as well as pretreatment/conditioning of the sample pad led to the final optimized LFA strip. Technology development also included optimization of excitation liquid enclosed in disposable droppers, design of a custom cartridge and smartphone-based reader, and app development, even a prototype reader usable with any mobile phone. Excellent preclinical performance was first demonstrated with contrived samples and then with leftover clinical samples. Moving beyond traditional academic focus areas, we were able to establish a quality management system (QMS), produce large numbers of customized LFA cassettes by contract injection molding, build in-house facilities to assemble and store thousands of complete tests for verification and validation and usability studies, and source kitting/packaging services and quality standard reagents and build partnerships for clinical translation, regulatory guidance, scale up, and market deployment. We were not able to bring this early stage technology to the point of commercialization within the limited time and resources available, but we did achieve strong proof-of-concept and advance translational aspects of the platform including initial high-performance LFAs, reading by the iPhone app using only a $2 plastic dark box with no lens, and convenient, usable excitation liquid packaging in droppers manufacturable in very large numbers.In this Account, we aim to provide a concise overview of our 18-month sprint toward the practical development of a deployable antigen lateral flow assay under pandemic conditions and the challenges and successes experienced by our team. We highlight what it takes to coach a technically savvy but commercially inexperienced academic team through the accelerated translation of an early stage technology into a useful product. Finally, we provide a guided tutorial and workflow to empower others interested in the rapid development of translatable LFAs.
Collapse
Affiliation(s)
- Katerina Kourentzi
- William
A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77004, United States
| | - Kristen Brosamer
- Department
of Biomedical Engineering, University of
Houston, Houston, Texas 77004, United States
| | - Binh Vu
- William
A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77004, United States
| | - Richard C. Willson
- William
A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77004, United States
- Department
of Biomedical Engineering, University of
Houston, Houston, Texas 77004, United States
- Department
of Biology and Biochemistry, University
of Houston, Houston, Texas 77004, United States
- Escuela
de Medicina y Ciencias de Salud, Tecnológico
de Monterrey, 64849 Monterrey, Nuevo León, México
| |
Collapse
|
5
|
Lei R, Arain H, Wang D, Arunachalam J, Saxena R, Mohan C. Duplex Vertical-Flow Rapid Tests for Point-of-Care Detection of Anti-dsDNA and Anti-Nuclear Autoantibodies. BIOSENSORS 2024; 14:98. [PMID: 38392017 PMCID: PMC10887294 DOI: 10.3390/bios14020098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 02/08/2024] [Accepted: 02/09/2024] [Indexed: 02/24/2024]
Abstract
The goal of this study is to develop a rapid diagnostic test for rheumatic disease and systemic lupus erythematosus (SLE) screening. A novel rapid vertical flow assay (VFA) was engineered and used to assay anti-nuclear (ANA) and anti-dsDNA (αDNA) autoantibodies from systemic lupus erythematosus (SLE) patients and healthy controls (HCs). Observer scores and absolute signal intensities from the VFA were validated via ELISA. The rapid point-of-care VFA test that was engineered demonstrated a limit of detection of 0.5 IU/mL for ANA and αDNA autoantibodies in human plasma with an inter-operator CV of 19% for ANA and 12% for αDNA. Storage stability was verified over a three-month period. When testing anti-dsDNA and ANA levels in SLE and HC serum samples, the duplex VFA revealed 95% sensitivity, 72% specificity and an 84% ROC AUC value in discriminating disease groups, comparable to the gold standard, ELISA. The rapid αDNA/ANA duplex VFA can potentially be used in primary care clinics for evaluating patients or at-risk subjects for rheumatic diseases and for planning follow-up testing. Given its low cost, ease, and rapid turnaround, it can also be used to assess SLE prevalence estimates.
Collapse
Affiliation(s)
- Rongwei Lei
- Department Biomedical Engineering, University of Houston, Houston, TX 77204, USA; (R.L.); (H.A.); (J.A.)
| | - Hufsa Arain
- Department Biomedical Engineering, University of Houston, Houston, TX 77204, USA; (R.L.); (H.A.); (J.A.)
| | - David Wang
- John Sealy School of Medicine, UT Medical Branch, Galveston, TX 77555, USA;
| | - Janani Arunachalam
- Department Biomedical Engineering, University of Houston, Houston, TX 77204, USA; (R.L.); (H.A.); (J.A.)
| | - Ramesh Saxena
- UT Southwestern Medical Center, Dallas, TX 75390, USA;
| | - Chandra Mohan
- Department Biomedical Engineering, University of Houston, Houston, TX 77204, USA; (R.L.); (H.A.); (J.A.)
| |
Collapse
|
6
|
Bachir W. Diffuse transmittance visible spectroscopy using smartphone flashlight for photoplethysmography and vital signs measurements. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 303:123181. [PMID: 37506454 DOI: 10.1016/j.saa.2023.123181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 07/06/2023] [Accepted: 07/20/2023] [Indexed: 07/30/2023]
Abstract
Photoplethysmography (PPG), with its wide range of applications, has become one of the most promising modalities for healthcare monitoring technology. In this work, we present a new PPG measurement technique based on diffuse transmittance spectroscopy (DTS) with the help of a smartphone built-in flashlight as an alternative broadband light source. The blood Volume Pulse (BVP) signal was extracted from recorded transmittance spectra at 620 nm. The results were compared with the ground truth and conventional contact finger PPG sensors. A very high correlation was found between the diffuse transmittance signal and the reference PPG signals (r = 0.997, p < 0.0001). The accuracy and root mean square error (RMSE) were 99.23% and 0.8 bpm, respectively. In addition, a Bland-Altman analysis showed a good agreement between both techniques, with a very small bias between mean paired differences of heart rate observations. A simple forward model for diffuse transmittance spectra for different levels of blood oxygen saturation is developed and supported by experimental measurements. It was also found that blood oxygen saturation (SpO2) can be estimated with the aid of DTS based smartphone flash by tracking the wavelength corresponding to the oxygenation level in the visible range between orange and red regions of the visible spectrum particularly in the range between 610 and 635 nm for 26 healthy subjects. 624 nm on average seems to be the wavelength that corresponds with the normal blood oxygenation level. These findings show the potential of DTS PPG to reliably extract cardiac frequency and estimate SpO2 with adequate accuracy. The results also demonstrate the capability of smartphone flash as a miniature visible light source for recording multispectral PPG signals and quantifying vital signs in the transmission mode at the fingertip with acceptable signal quality over a wide range of wavelengths from 550 nm to 650 nm.
Collapse
Affiliation(s)
- Wesam Bachir
- Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, Św. A. Boboli 8 St., Warsaw 02-525, Poland; Biomedical Photonics Laboratory, Higher Institute for Laser Research and Applications, Damascus University, Damascus, Syria
| |
Collapse
|
7
|
Nam SW, Jeon DG, Yoon YR, Lee GH, Chang Y, Won DI. Hemagglutination Assay via Optical Density Characterization in 3D Microtrap Chips. BIOSENSORS 2023; 13:733. [PMID: 37504130 PMCID: PMC10377501 DOI: 10.3390/bios13070733] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 07/12/2023] [Accepted: 07/12/2023] [Indexed: 07/29/2023]
Abstract
Hemagglutination assay has been used for blood typing and detecting viruses, thus applicable for the diagnosis of infectious diseases, including COVID-19. Therefore, the development of microfluidic devices for fast detection of hemagglutination is on-demand for point-of-care diagnosis. Here, we present a way to detect hemagglutination in 3D microfluidic devices via optical absorbance (optical density, OD) characterization. 3D printing is a powerful way to build microfluidic structures for diagnostic devices. However, mixing liquid in microfluidic chips is difficult due to laminar flow, which hampers practical applications such as antigen-antibody mixing. To overcome the issue, we fabricated 3D microfluidic chips with embedded microchannel and microwell structures to induce hemagglutination between red blood cells (RBCs) and antibodies. We named it a 3D microtrap chip. We also established an automated measurement system which is an integral part of diagnostic devices. To do this, we developed a novel way to identify RBC agglutination and non-agglutination via the OD difference. By adapting a 3D-printed aperture to the microtrap chip, we obtained a pure absorbance signal from the microchannels by eliminating the background brightness of the microtrap chip. By investigating the underlying optical physics, we provide a 3D device platform for detecting hemagglutination.
Collapse
Affiliation(s)
- Sung-Wook Nam
- Department of Molecular Medicine, School of Medicine, Kyungpook National University, Daegu 41405, Republic of Korea
- DanielBio Research Center, Daegu 42694, Republic of Korea
- Bio-Medical Research Institute, Kyungpook National University Hospital, Daegu 41940, Republic of Korea
| | - Dong-Gyu Jeon
- Department of Molecular Medicine, School of Medicine, Kyungpook National University, Daegu 41405, Republic of Korea
- Cell & Matrix Research Institute, Kyungpook National University, Daegu 41944, Republic of Korea
| | - Young-Ran Yoon
- Department of Molecular Medicine, School of Medicine, Kyungpook National University, Daegu 41405, Republic of Korea
| | - Gang Ho Lee
- Department of Chemistry, College of Natural Sciences, Kyungpook National University, Daegu 41566, Republic of Korea
| | - Yongmin Chang
- Department of Molecular Medicine, School of Medicine, Kyungpook National University, Daegu 41405, Republic of Korea
| | - Dong Il Won
- Bio-Medical Research Institute, Kyungpook National University Hospital, Daegu 41940, Republic of Korea
- Department of Clinical Pathology, School of Medicine, Kyungpook National University, Daegu 41940, Republic of Korea
| |
Collapse
|
8
|
Danthanarayana AN, Nandy S, Kourentzi K, Vu B, Shelite TR, Travi BL, Brgoch J, Willson RC. Smartphone-readable RPA-LFA for the high-sensitivity detection of Leishmania kDNA using nanophosphor reporters. PLoS Negl Trop Dis 2023; 17:e0011436. [PMID: 37399214 PMCID: PMC10353800 DOI: 10.1371/journal.pntd.0011436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2022] [Accepted: 06/05/2023] [Indexed: 07/05/2023] Open
Abstract
Early diagnosis of infectious diseases improves outcomes by enabling earlier delivery of effective treatment, and helps prevent further transmission by undiagnosed persons. We demonstrated a proof-of-concept assay combining isothermal amplification and lateral flow assay (LFA) for early diagnosis of cutaneous leishmaniasis, a vector-borne infectious disease that affects ca. 700,000 to 1.2 million people annually. Conventional molecular diagnostic techniques based on polymerase chain reaction (PCR) require complex apparatus for temperature cycling. Recombinase polymerase amplification (RPA) is an isothermal DNA amplification method that has shown promise for use in low-resource settings. Combined with lateral flow assay as the readout, RPA-LFA can be used as a point-of-care diagnostic tool with high sensitivity and specificity, but reagent costs can be problematic. In this work, we developed a highly-sensitive smartphone-based RPA-LFA for the detection of Leishmania panamensis DNA using blue-emitting [(Sr0.625Ba0.375)1.96Eu0.01Dy0.03]MgSi2O7 (SBMSO) persistent luminescent nanophosphors as LFA reporters. The greater detectability of nanophosphors allows the use of a reduced volume of RPA reagents, potentially reducing the cost of RPA-LFA. The limit of detection (LOD) of RPA with gold nanoparticle-based LFA readout is estimated at 1 parasite per reaction, but LOD can be 100-fold better, 0.01 parasites per reaction, for LFA based on SBMSO. This approach may be useful for sensitive and cost-effective point-of-care diagnosis and contribute to improved clinical and economic outcomes, especially in resource-limited settings.
Collapse
Affiliation(s)
| | - Suman Nandy
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, United States of America
| | - Katerina Kourentzi
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, United States of America
| | - Binh Vu
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, United States of America
| | - Thomas R Shelite
- Department of Biosafety, University of Texas Medical Branch, Galveston, Texas, United States of America
| | - Bruno L Travi
- Department of Biosafety, University of Texas Medical Branch, Galveston, Texas, United States of America
- Department of Internal Medicine, University of Texas Medical Branch, Galveston, Texas, United States of America
| | - Jakoah Brgoch
- Department of Chemistry, University of Houston, Houston, Texas, United States of America
| | - Richard C Willson
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, United States of America
- Department of Biology and Biochemistry, University of Houston, Houston, Texas, United States of America
| |
Collapse
|