1
|
Wenta R, Richert J, Muchlińska A, Senkus E, Suchodolska G, Łapińska-Szumczyk S, Domżalski P, Miszewski K, Matuszewski M, Dziadziuszko R, Supernat A, Żaczek A, Bednarz-Knoll N. Measurable morphological features of single circulating tumor cells in selected solid tumors-A pilot study. Cytometry A 2024; 105:883-892. [PMID: 39498617 DOI: 10.1002/cyto.a.24906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Revised: 10/16/2024] [Accepted: 10/22/2024] [Indexed: 12/15/2024]
Abstract
Liquid biopsies developed into a range of sensitive technologies aiming to analyze for example, circulating tumor cells (CTCs) in peripheral blood, which significantly deepens understanding of the metastatic process. Nevertheless, examination of CTCs is mostly limited to their enumeration and usually only 2-3 markers-based phenotyping, not offering yet sufficient insight into their biology. In contrast, quantitative analysis of their morphological details might extend our knowledge about dissemination and even improve CTC isolation or label-free identification methods dependent on their physical features such as size, and deformability. Current study was conducted to describe CTCs' and their size, shape, presence of protrusions, and micronuclei across various types of cancers (lung, n = 29; ovarian, n = 24, breast, n = 54; and prostate, n = 33). Epithelial (pan-keratins), mesenchymal (vimentin), and two exclusion markers were used to identify CTCs and classify them into four epithelial and epithelial-mesenchymal transition-related phenotypes using standardized and throughput method, imaging flow cytometry. The morphological characteristics of CTCs, including their nuclei, such as circularity, the maximum, and minimum diagonal values were determined using an open-source software QuPath. On average, detected CTCs (n = 1156) were larger, and more irregular in shape compared to leukocytes/endothelial cells (n = 400). Epithelial and mesenchymal CTCs had the largest (median = 18.2 μm) and the smallest diameter (median = 10.4 μm), respectively. In terms of cancer-specific variations, the largest CTCs were identified in lung cancer, whereas the smallest-in prostate and breast cancers. Epithelial CTCs and those negative for both epithelial and mesenchymal markers exhibited the highest degree of elongation, whereas mesenchymal CTCs were the most irregular in shape. Protrusions and micronuclei were observed extremely rarely within CTCs of breast and prostate cancer (0.6%-0.8% of CTCs). Micronuclei were observed only in epithelial and epithelial-mesenchymal CTCs. This study underscores the significant variability in the morphological features of CTCs in relation to their phenotypic classification or even the particular organ of origin, potentially influencing for example, size-dependent CTC isolation methods. It demonstrates for the first time the morphological measurements of CTCs undergoing epithelial-mesenchymal transition, and some specific morphological details (i.e., protrusions, micronuclei) within CTCs in general.
Collapse
Affiliation(s)
- Robert Wenta
- Laboratory of Translational Oncology, Intercollegiate Faculty of Biotechnology, Medical University of Gdańsk, Gdańsk, Poland
| | - Julia Richert
- Laboratory of Translational Oncology, Intercollegiate Faculty of Biotechnology, Medical University of Gdańsk, Gdańsk, Poland
| | - Anna Muchlińska
- Laboratory of Translational Oncology, Intercollegiate Faculty of Biotechnology, Medical University of Gdańsk, Gdańsk, Poland
| | - Elżbieta Senkus
- Department of Oncology and Radiotherapy, Medical University of Gdańsk, Gdańsk, Poland
| | - Grażyna Suchodolska
- Department of Oncology and Radiotherapy, Medical University of Gdańsk, Gdańsk, Poland
| | - Sylwia Łapińska-Szumczyk
- Department of Gynaecology, Gynaecological Oncology and Gynaecological Endocrinology, Medical University of Gdańsk, Gdańsk, Poland
| | - Paweł Domżalski
- Early Phase Clinical Trials Centre, Medical University of Gdańsk, Gdańsk, Poland
- Department of Histology, Medical University of Gdańsk, Gdańsk, Poland
| | - Kevin Miszewski
- Department of Urology, Medical University of Gdańsk, Gdańsk, Poland
| | | | - Rafał Dziadziuszko
- Department of Oncology and Radiotherapy, Medical University of Gdańsk, Gdańsk, Poland
| | - Anna Supernat
- Laboratory of Translational Oncology, Intercollegiate Faculty of Biotechnology, Medical University of Gdańsk, Gdańsk, Poland
| | - Anna Żaczek
- Laboratory of Translational Oncology, Intercollegiate Faculty of Biotechnology, Medical University of Gdańsk, Gdańsk, Poland
| | - Natalia Bednarz-Knoll
- Laboratory of Translational Oncology, Intercollegiate Faculty of Biotechnology, Medical University of Gdańsk, Gdańsk, Poland
| |
Collapse
|
2
|
Zhao L, Fang Y, Chen X, Meng Y, Wang F, Li C. Carbon dot-based fluorescent probe for early diagnosis of pheochromocytoma through identification of circulating tumor cells. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 310:123921. [PMID: 38271847 DOI: 10.1016/j.saa.2024.123921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 12/19/2023] [Accepted: 01/18/2024] [Indexed: 01/27/2024]
Abstract
Pheochromocytoma (PCC), as a rare neuroendocrine tumor, is often missed or misdiagnosed because of its atypical clinical manifestations. To realize the early accurate diagnosis of PCC, we have selected circulating tumor cells (CTCs) with more complete biological information as biomarkers and developed a simple and novel fluorescence cytosensor. Octreotide-2,2',2'',2'''- (1,4,7,10 -tetraazacyclododecane-1,4,7,10-tetrayl) tetraacetic acid (DOTA) modified magnetic Fe3O4 and signal amplification CDs@SiO2 nanospheres are prepared to capture and detect PCC-CTCs from peripheral blood via binding to the somatostatin receptor SSTR2 overexpressed on the surface of PCC cells. During the detection process, the target cells were separated and enriched by magnetic capture probes (Fe3O4-DOTA), and then signal probes (CDs@SiO2-DOTA) could also specifically bound to target cells to form the sandwich-like structure for fluorescence signal output. The proposed fluorescence cytosensor has revealed good sensitivity and selectivity for quantitative analysis of PCC-CTCs in the concentration of 5-1000 cells mL-1 with a LOD of 2 cells mL-1. More importantly, designed fluorescence cytosensor has shown good reliability and stability in complex serum samples. This strategy provides a new way for detection of PCC-CTCs.
Collapse
Affiliation(s)
- Liping Zhao
- Department of Chemistry, School of Science, China Pharmaceutical University, Nanjing 211198, Jiangsu, PR China
| | - Yiwei Fang
- Department of Chemistry, School of Science, China Pharmaceutical University, Nanjing 211198, Jiangsu, PR China
| | - Xinhe Chen
- Department of Chemistry, School of Science, China Pharmaceutical University, Nanjing 211198, Jiangsu, PR China
| | - Yang Meng
- Department of Chemistry, School of Science, China Pharmaceutical University, Nanjing 211198, Jiangsu, PR China
| | - Fei Wang
- Department of Chemistry, School of Science, China Pharmaceutical University, Nanjing 211198, Jiangsu, PR China; Cell and Biomolecule Recognition Research Center, School of Science, China Pharmaceutical University, Nanjing 211198, Jiangsu, PR China.
| | - Caolong Li
- Department of Chemistry, School of Science, China Pharmaceutical University, Nanjing 211198, Jiangsu, PR China; Cell and Biomolecule Recognition Research Center, School of Science, China Pharmaceutical University, Nanjing 211198, Jiangsu, PR China.
| |
Collapse
|