1
|
Kurdadze T, Lamadie F, Nehme KA, Teychené S, Biscans B, Rodriguez-Ruiz I. On-Chip Photonic Detection Techniques for Non-Invasive In Situ Characterizations at the Microfluidic Scale. SENSORS (BASEL, SWITZERLAND) 2024; 24:1529. [PMID: 38475065 DOI: 10.3390/s24051529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 02/21/2024] [Accepted: 02/22/2024] [Indexed: 03/14/2024]
Abstract
Microfluidics has emerged as a robust technology for diverse applications, ranging from bio-medical diagnostics to chemical analysis. Among the different characterization techniques that can be used to analyze samples at the microfluidic scale, the coupling of photonic detection techniques and on-chip configurations is particularly advantageous due to its non-invasive nature, which permits sensitive, real-time, high throughput, and rapid analyses, taking advantage of the microfluidic special environments and reduced sample volumes. Putting a special emphasis on integrated detection schemes, this review article explores the most relevant advances in the on-chip implementation of UV-vis, near-infrared, terahertz, and X-ray-based techniques for different characterizations, ranging from punctual spectroscopic or scattering-based measurements to different types of mapping/imaging. The principles of the techniques and their interest are discussed through their application to different systems.
Collapse
Affiliation(s)
- Tamar Kurdadze
- CEA, DES, ISEC, DMRC, Univ Montpellier, 30207 Bagnols-sur-Ceze, Marcoule, France
| | - Fabrice Lamadie
- CEA, DES, ISEC, DMRC, Univ Montpellier, 30207 Bagnols-sur-Ceze, Marcoule, France
| | - Karen A Nehme
- Laboratoire de Génie Chimique, CNRS, UMR 5503, 4 Allée Emile Monso, 31432 Toulouse, France
| | - Sébastien Teychené
- Laboratoire de Génie Chimique, CNRS, UMR 5503, 4 Allée Emile Monso, 31432 Toulouse, France
| | - Béatrice Biscans
- Laboratoire de Génie Chimique, CNRS, UMR 5503, 4 Allée Emile Monso, 31432 Toulouse, France
| | - Isaac Rodriguez-Ruiz
- Laboratoire de Génie Chimique, CNRS, UMR 5503, 4 Allée Emile Monso, 31432 Toulouse, France
| |
Collapse
|
2
|
Wang Z, Wu Y, Yu W, Qi D, Bakhtiyari AN, Zheng H. Investigation into fabrication and optical characteristics of tunable optofluidic microlenses using two-photon polymerization. OPTICS EXPRESS 2024; 32:7448-7462. [PMID: 38439424 DOI: 10.1364/oe.515245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 01/25/2024] [Indexed: 03/06/2024]
Abstract
Optofluidic systems, integrating microfluidic and micro-optical technologies, have emerged as transformative tools for various applications, from molecular detection to flow cytometry. However, existing optofluidic microlenses often rely on external forces for tunability, hindering seamless integration into systems. This work presents an approach using two-photon polymerization (TPP) to fabricate inherently tunable microlens arrays, eliminating the need for supplementary equipment. The optofluidic design incorporates a three-layered structure enabling dynamic manipulation of refractive indices within microchannels, leading to tunable focusing characteristics. It is shown that the TPP fabricated optofluidic microlenses exhibit inherent tunable focal lengths, numerical apertures, and spot sizes without reliance on external forces. This work signifies some advancements in optofluidic technology, offering precise and tunable microlenses with potential applications in adaptive imaging and variable focal length microscopy.
Collapse
|
3
|
Zhu Y, Lam MY, Wang N, Zhang X. Optofluidic tunable filters using ionic liquid electrolyte capacitors. OPTICS EXPRESS 2024; 32:4698-4708. [PMID: 38297664 DOI: 10.1364/oe.515689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 01/16/2024] [Indexed: 02/02/2024]
Abstract
Tunable optical filter is a basic component for most optical systems. This study reports a unique design of Fabry-Pérot (FP) tunable filter by using an ionic liquid solution. The tunable filter consists of two neighboring regions: capacitor region and FP region. The former is in the form of electrolyte capacitor and the latter remains transparent as an FP cavity for light transmission. When the capacitor region is applied with a bias voltage, it attracts the ions from the FP region and thus reduces the ion concentration of the FP region, resulting in a change of the refractive index and eventually a shift of transmission peak of the FP cavity. Among four electrolyte solutions studied, 1-butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6) exhibits the best overall performance, such as low insertion loss (3.2 dB), large side mode suppression ratio (23 dB) and high stability (drift <0.2 nm). Additionally, a wavelength tuning of 0.17 nm/V is achieved over 0-17 V, providing a tunable range of 3 nm. This device features low bias voltage, no mechanical movement, easy fabrication and seamless integration with microfluidics systems, and may find potential applications in spectral analyzers and lab-on-a-chip biosensing systems.
Collapse
|
4
|
Qiu G, Zhang X, deMello AJ, Yao M, Cao J, Wang J. On-site airborne pathogen detection for infection risk mitigation. Chem Soc Rev 2023; 52:8531-8579. [PMID: 37882143 PMCID: PMC10712221 DOI: 10.1039/d3cs00417a] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Indexed: 10/27/2023]
Abstract
Human-infecting pathogens that transmit through the air pose a significant threat to public health. As a prominent instance, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that caused the COVID-19 pandemic has affected the world in an unprecedented manner over the past few years. Despite the dissipating pandemic gloom, the lessons we have learned in dealing with pathogen-laden aerosols should be thoroughly reviewed because the airborne transmission risk may have been grossly underestimated. From a bioanalytical chemistry perspective, on-site airborne pathogen detection can be an effective non-pharmaceutic intervention (NPI) strategy, with on-site airborne pathogen detection and early-stage infection risk evaluation reducing the spread of disease and enabling life-saving decisions to be made. In light of this, we summarize the recent advances in highly efficient pathogen-laden aerosol sampling approaches, bioanalytical sensing technologies, and the prospects for airborne pathogen exposure measurement and evidence-based transmission interventions. We also discuss open challenges facing general bioaerosols detection, such as handling complex aerosol samples, improving sensitivity for airborne pathogen quantification, and establishing a risk assessment system with high spatiotemporal resolution for mitigating airborne transmission risks. This review provides a multidisciplinary outlook for future opportunities to improve the on-site airborne pathogen detection techniques, thereby enhancing the preparedness for more on-site bioaerosols measurement scenarios, such as monitoring high-risk pathogens on airplanes, weaponized pathogen aerosols, influenza variants at the workplace, and pollutant correlated with sick building syndromes.
Collapse
Affiliation(s)
- Guangyu Qiu
- Institute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
- Institute of Environmental Engineering, ETH Zürich, Zürich 8093, Switzerland
- Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
| | - Xiaole Zhang
- Institute of Environmental Engineering, ETH Zürich, Zürich 8093, Switzerland
- Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
| | - Andrew J deMello
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg1, Zürich, Switzerland
| | - Maosheng Yao
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, China
| | - Junji Cao
- Institute of Atmospheric Physics, Chinese Academy of Science, China
| | - Jing Wang
- Institute of Environmental Engineering, ETH Zürich, Zürich 8093, Switzerland
- Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
| |
Collapse
|
5
|
Bodo E, Gowda HGB, Wallrabe U, Wapler MC. In-line refractive index measurement: a simple method based on image detection. APPLIED OPTICS 2023; 62:6282-6286. [PMID: 37707097 DOI: 10.1364/ao.493243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Accepted: 07/18/2023] [Indexed: 09/15/2023]
Abstract
We present a simple method to determine the refractive index of fluids that is suitable for real-time integrated measurements by imaging a collimated beam through a fluid volume and determining its diameter on a CMOS sensor. Our experimental results agree with the prediction of our analytical model, and the resulting refractive index agrees with the measurements obtained with a commercial refractometer with an RMS deviation of just ±0.003. This method requires only inexpensive components: a light source, two lenses, and a camera sensor; it is suitable for real-time monitoring, and it is essentially unlimited in the range of refractive indices.
Collapse
|
6
|
Leça JM, Magalhães Y, Antunes P, Pereira V, Ferreira MS. Real-Time Measurement of Refractive Index Using 3D-Printed Optofluidic Fiber Sensor. SENSORS (BASEL, SWITZERLAND) 2022; 22:9377. [PMID: 36502090 PMCID: PMC9739723 DOI: 10.3390/s22239377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 11/25/2022] [Accepted: 11/28/2022] [Indexed: 06/17/2023]
Abstract
This work describes a 3D-printed optofluidic fiber sensor to measure refractive index in real time, combining a microfluidic system with an optical fiber extrinsic Fabry-Perot interferometer. The microfluidic chip platform was developed for this purpose through 3D printing. The Fabry-Perot cavity was incorporated in the microfluidic chip perpendicularly to the sample flow, which was of approximately 3.7 µL/s. The optofluidic fiber sensor platform coupled with a low-cost optical power meter detector was characterized using different concentrations of glucose solutions. In the linear regression analysis, the optical power shift was correlated with the refractive index and a sensitivity of -86.6 dB/RIU (r2 = 0.996) was obtained. Good results were obtained in terms of stability with a maximum standard deviation of 0.03 dB and a sensor resolution of 5.2 × 10-4 RIU. The feasibility of the optofluidic fiber sensor for dynamic analyses of refractive index with low sample usage was confirmed through real-time measurements.
Collapse
Affiliation(s)
- João M. Leça
- i3N & Physics Department, University of Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro, Portugal
| | - Yannis Magalhães
- i3N & Physics Department, University of Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro, Portugal
| | - Paulo Antunes
- i3N & Physics Department, University of Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro, Portugal
| | - Vanda Pereira
- i3N & Physics Department, University of Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro, Portugal
- ISOPlexis—Sustainable Agriculture and Food Technology Center, University of Madeira, Campus da Penteada, 9020-105 Funchal, Portugal
| | - Marta S. Ferreira
- i3N & Physics Department, University of Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro, Portugal
| |
Collapse
|
7
|
Tang J, Qiu G, Cao X, deMello A, Wang J. Microfluid Switching-Induced Transient Refractive Interface. ACS Sens 2022; 7:3521-3529. [PMID: 36356161 DOI: 10.1021/acssensors.2c01901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The laminar flow interface (LFI) developed at low Reynolds numbers is one of the most prominent features of microscale flows and has been employed in a diverse range of optofluidic applications. The formation of LFIs usually requires the manipulation of multiple streams within a microchannel using a complex hydrodynamic pumping system. Herein, we present a new type of LFI that is generated by fluid switching within a three-dimensional (3D) microlens-incorporating microfluidic chip (3D-MIMC). Since Poiseuille flows exhibit a parabolic velocity profile, the LFI is cone-like in shape and acts as a transient refractive interface (TRI), which is sensitive to the refractive index (RI) and the Péclet number (Pe) of the switching fluids. In response to the TRI, the intensity of the transmitted light can be intensified or attenuated depending on the sequence of fluid switching operations. By incorporating three-dimensional (3D) microlenses and increasing the Pe values, the profile and amplitude of the intensity peak are both significantly improved. The limit of detection (LoD) for a sodium chloride (NaCl) solution at Pe = 1363 is as low as 0.001% (w/w), representing an improvement of 1-2 orders of magnitude when compared to existing optofluidic concentration sensors based on intensity modulation. Fluid switching of a variety of inorganic and organic sample fluids confirms that the specific optical response (Kor) correlates positively with both Pe and the specific RI (Knc), obeying a linear relationship. This model is further verified through cross-validations and used to estimate the molecular diffusion coefficient (D) of a range of species. Furthermore, by virtue of the TRI, we achieve a sensitive measurement of optical-equivalent total dissolved solids (OE-TDS) for environmental samples.
Collapse
Affiliation(s)
- Jiukai Tang
- Institute of Environmental Engineering, ETH Zürich, Zürich8093, Switzerland.,Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf8600, Switzerland
| | - Guangyu Qiu
- Institute of Environmental Engineering, ETH Zürich, Zürich8093, Switzerland.,Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf8600, Switzerland.,School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai200240, China
| | - Xiaobao Cao
- Institute of Chemical and Bioengineering, ETH Zürich, Zürich8093, Switzerland.,Guangzhou Lab, International Bio Island, Haizhu District, Guangzhou510005, Guangdong, China
| | - Andrew deMello
- Institute of Chemical and Bioengineering, ETH Zürich, Zürich8093, Switzerland
| | - Jing Wang
- Institute of Environmental Engineering, ETH Zürich, Zürich8093, Switzerland.,Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf8600, Switzerland
| |
Collapse
|
8
|
|
9
|
Testa G, Persichetti G, Bernini R. Planar Optofluidic Integration of Ring Resonator and Microfluidic Channels. MICROMACHINES 2022; 13:mi13071028. [PMID: 35888845 PMCID: PMC9315487 DOI: 10.3390/mi13071028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 06/15/2022] [Accepted: 06/23/2022] [Indexed: 02/01/2023]
Abstract
We report an optofluidic hybrid silicon-polymer planar ring resonator with integrated microfluidic channels for efficient liquid delivery. The device features a planar architecture of intersecting liquid-core waveguides and microfluidic channels. A low-loss integration of microfluidic channels is accomplished by exploiting the interference pattern created by the self-imaging effect in the multimode interference-based coupler waveguides. Numerical simulations have been performed in order to minimize the propagation losses along the ring loop caused by the integration of microfluidic channels. The device has been fabricated and optically characterized by measuring the quality factor, obtaining a value of 4 × 103. This result is comparable with the quality factor of an optofluidic ring with the same optical layout but without integrated microfluidic channels, thus, confirming the suitability of the proposed approach for microfluidics integration in planar optofluidic design.
Collapse
|
10
|
Optofluidic Micromachined Platform for Refractive Index Measurement. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10050197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
We present a combination of micromachined optofluidic platforms equipped with a fiber-optic sensing configuration based on a three-path Mach–Zehnder interferometer (MZI) for simultaneous measurement of the refractive index of liquids and the autocalibration in dynamic regime. The sensing principle is based on the low-coherence interferometry, characterized by a generation of Gaussian enveloped interferograms, for which the position of its maximum depends on the optical path difference (OPD) between the sensing and reference arm of the MZI. When liquid flows through the central microchannel of the optofluidic platform it crosses the light beam between the two optical fibers in the sensing arm causing the OPD change. An algorithm has been applied for the calculation of the refractive index of liquids out of the raw interference signals. We obtained a very good agreement between the experimental results and literature data of refractive indices of subjected fluids. The accuracy of refractive index measurement is approximately 1%, predominantly determined by the accuracy of reading the position of the mechanical scanner. The proposed sensor is attractive for the label-free biological, biochemical, and chemical sensing owing autocalibration and high sensitivity yet consuming a very small sample volume of 1 µL. It is capable to measure the refractive index of various liquids and/or gases simultaneously in the process.
Collapse
|