1
|
Mudau M, Ngobeni-Nyambi R, Momba MNB. The Fascinating Cross-Paths of Pathogenic Bacteria, Human and Animal Faecal Sources in Water-Stressed Communities of Vhembe District, South Africa. Pathogens 2023; 12:1085. [PMID: 37764893 PMCID: PMC10535812 DOI: 10.3390/pathogens12091085] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/16/2023] [Accepted: 08/24/2023] [Indexed: 09/29/2023] Open
Abstract
Access to clean and safe drinking water still remains a major challenge in the developing world, causing public health risks in terms of waterborne infections, especially in rural areas of sub-Saharan Africa. This study aimed to track and detect enteric pathogens (Salmonella enterica subsp. enterica serovar Typhimurium str. LT2, Shigella flexneri, and Campylobacter jejuni subsp. jejuni) in rural water sources. It also sought to establish a correlation between these pathogens and the sources of faecal pollution. Multiplex qPCR and specific primers and probes were used for detection and tracking. The study successfully correlated the occurrence of target pathogens with sources of human and animal faecal contamination using host-specific genetic markers (BacHum and HF183 for humans, BacCow for cows, Pig-2-Bac for pigs, Cytb for chickens, and BacCan for dogs). The study revealed that enteric pathogens were found in 47.69% and 32.80% of samples during the wet and dry seasons, respectively. These pathogens were associated with human or animal faecal contamination. Correlations between pathogens and contamination sources were significant (p ≤ 0.05), with varying strengths during the wet and dry seasons. The findings emphasize the importance of identifying faecal contamination sources to protect rural communities from waterborne infections.
Collapse
Affiliation(s)
- Mulalo Mudau
- Department of Environmental, Water and Earth Sciences, Tshwane University of Technology, Arcadia Campus, Private Bag X680, Pretoria 0001, South Africa
| | - Renay Ngobeni-Nyambi
- Department of Medicine, Division of Infectious Diseases, University of North Carolina School of Medicine, Chapel Hill, NC 27599, USA;
| | - Maggy Ndombo Benteke Momba
- Department of Environmental, Water and Earth Sciences, Tshwane University of Technology, Arcadia Campus, Private Bag X680, Pretoria 0001, South Africa
| |
Collapse
|
2
|
Gerdan Z, Saylan Y, Denizli A. Recent Advances of Optical Sensors for Copper Ion Detection. MICROMACHINES 2022; 13:1298. [PMID: 36014218 PMCID: PMC9413819 DOI: 10.3390/mi13081298] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 07/30/2022] [Accepted: 08/08/2022] [Indexed: 06/15/2023]
Abstract
A trace element copper (Cu2+) ion is the third most plentiful metal ion that necessary for all living organisms and playing a critical role in several processes. Nonetheless, according to cellular needs, deficient or excess Cu2+ ion cause various diseases. For all these reasons, optical sensors have been focused rapid Cu2+ ion detection in real-time with high selectivity and sensitivity. Optical sensors can measure fluorescence in the refractive index-adsorption from the relationships between light and matter. They have gained great attention in recent years due to the excellent advantages of simple and naked eye recognition, real-time detection, low cost, high specificity against analytes, a quick response, and the need for less complex equipment in analysis. This review aims to show the significance of Cu2+ ion detection and electively current trends in optical sensors. The integration of optical sensors with different systems, such as microfluidic systems, is mentioned, and their latest studies in medical and environmental applications also are depicted. Conclusions and future perspectives on these advances is added at the end of the review.
Collapse
Affiliation(s)
| | | | - Adil Denizli
- Department of Chemistry, Hacettepe University, 06800 Ankara, Turkey
| |
Collapse
|
3
|
Naseri M, Maliha M, Dehghani M, Simon GP, Batchelor W. Rapid Detection of Gram-Positive and -Negative Bacteria in Water Samples Using Mannan-Binding Lectin-Based Visual Biosensor. ACS Sens 2022; 7:951-959. [PMID: 35290028 DOI: 10.1021/acssensors.1c01748] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Waterborne bacterial infection is a health threat worldwide, making accurate and timely bacteria detection crucial to prevent waterborne disease outbreaks. Inspired by the intrinsic capability of mannan-binding lectin (MBL) in recognizing the pathogen-associated molecular patterns (PAMPs), a visual biosensor is developed here for the on-site detection of both Gram-positive and -negative bacteria. The biosensor was synthesized by immobilization of the MBL protein onto the blue carboxyl-functionalized polystyrene microparticles (PSM), which is then used in a two-step assay to detect bacterial cells in water samples. The first step involved a 20 min incubation following the MBL-PSM and calcium chloride solution addition to the samples. The second step was to add ethanol to the resultant blue mixture and observe the color change with the naked eye after 15 min. The biosensor had a binary (all-or-none) response, which in the presence of bacterial cells kept its blue color, while in their absence the color changed from blue to colorless. Testing the water samples spiked with four Gram-negative bacteria including Acinetobacter baumannii, Escherichia coli, Klebsiella pneumoniae, and Pseudomonas aeruginosa and two Gram-positive bacteria of Enterococcus faecalis and Staphylococcus aureus showed that the biosensor could detect all tested bacteria with a concentration as low as 101.5 CFU/ml. The performance of biosensor using the water samples from a water treatment plant also confirmed its capability to detect the pathogens in real-life water samples without the need for instrumentation.
Collapse
Affiliation(s)
- Mahdi Naseri
- Bioresource Processing Research Institute of Australia (BioPRIA), Department of Chemical Engineering, Monash University, Clayton, Victoria 3800, Australia
| | - Maisha Maliha
- Bioresource Processing Research Institute of Australia (BioPRIA), Department of Chemical Engineering, Monash University, Clayton, Victoria 3800, Australia
| | - Mostafa Dehghani
- Bioresource Processing Research Institute of Australia (BioPRIA), Department of Chemical Engineering, Monash University, Clayton, Victoria 3800, Australia
| | - George P Simon
- Department of Materials Science and Engineering, Monash University, Clayton, Victoria 3800, Australia
| | - Warren Batchelor
- Bioresource Processing Research Institute of Australia (BioPRIA), Department of Chemical Engineering, Monash University, Clayton, Victoria 3800, Australia
| |
Collapse
|
4
|
Péter B, Farkas E, Kurunczi S, Szittner Z, Bősze S, Ramsden JJ, Szekacs I, Horvath R. Review of Label-Free Monitoring of Bacteria: From Challenging Practical Applications to Basic Research Perspectives. BIOSENSORS 2022; 12:bios12040188. [PMID: 35448248 PMCID: PMC9026780 DOI: 10.3390/bios12040188] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/07/2022] [Accepted: 03/11/2022] [Indexed: 05/10/2023]
Abstract
Novel biosensors already provide a fast way to detect the adhesion of whole bacteria (or parts of them), biofilm formation, and the effect of antibiotics. Moreover, the detection sensitivities of recent sensor technologies are large enough to investigate molecular-scale biological processes. Usually, these measurements can be performed in real time without using labeling. Despite these excellent capabilities summarized in the present work, the application of novel, label-free sensor technologies in basic biological research is still rare; the literature is dominated by heuristic work, mostly monitoring the presence and amount of a given analyte. The aims of this review are (i) to give an overview of the present status of label-free biosensors in bacteria monitoring, and (ii) to summarize potential novel directions with biological relevancies to initiate future development. Optical, mechanical, and electrical sensing technologies are all discussed with their detailed capabilities in bacteria monitoring. In order to review potential future applications of the outlined techniques in bacteria research, we summarize the most important kinetic processes relevant to the adhesion and survival of bacterial cells. These processes are potential targets of kinetic investigations employing modern label-free technologies in order to reveal new fundamental aspects. Resistance to antibacterials and to other antimicrobial agents, the most important biological mechanisms in bacterial adhesion and strategies to control adhesion, as well as bacteria-mammalian host cell interactions are all discussed with key relevancies to the future development and applications of biosensors.
Collapse
Affiliation(s)
- Beatrix Péter
- Nanobiosensorics Laboratory, Centre for Energy Research, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (S.K.); (Z.S.); (I.S.)
- Correspondence: (B.P.); (R.H.)
| | - Eniko Farkas
- Nanobiosensorics Laboratory, Centre for Energy Research, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (S.K.); (Z.S.); (I.S.)
| | - Sandor Kurunczi
- Nanobiosensorics Laboratory, Centre for Energy Research, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (S.K.); (Z.S.); (I.S.)
| | - Zoltán Szittner
- Nanobiosensorics Laboratory, Centre for Energy Research, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (S.K.); (Z.S.); (I.S.)
| | - Szilvia Bősze
- MTA-ELTE Research Group of Peptide Chemistry, Eötvös Loránd Research Network (ELKH), Institute of Chemistry, Eötvös Loránd University, 1120 Budapest, Hungary;
- National Public Health Center, 1097 Budapest, Hungary
| | - Jeremy J. Ramsden
- Clore Laboratory, Department of Biomedical Research, University of Buckingham, Buckingham MK18 1AD, UK;
| | - Inna Szekacs
- Nanobiosensorics Laboratory, Centre for Energy Research, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (S.K.); (Z.S.); (I.S.)
| | - Robert Horvath
- Nanobiosensorics Laboratory, Centre for Energy Research, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (S.K.); (Z.S.); (I.S.)
- Correspondence: (B.P.); (R.H.)
| |
Collapse
|
5
|
Gerdan Z, Saylan Y, Uğur M, Denizli A. Ion-Imprinted Polymer-on-a-Sensor for Copper Detection. BIOSENSORS 2022; 12:91. [PMID: 35200351 PMCID: PMC8869677 DOI: 10.3390/bios12020091] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 01/27/2022] [Accepted: 01/30/2022] [Indexed: 06/14/2023]
Abstract
The accumulation of metal ions in the body is caused by human activities and industrial uses. Among these metal ions, copper is the third most abundant ion found in the human body and is indispensable for health because it works as a catalyst in the iron absorption processes. However, high doses of copper ions have been reported to generate various diseases. Different types of sensors are used to detect metal ions for several applications. To design selective and specific recognition sites on the sensor surfaces, molecular imprinting is one of the most used alteration methods to detect targets by mimicking natural recognition molecules. In this study, an ion-imprinted polymer-integrated plasmonic sensor was prepared to selectively detect copper (Cu(II)) ions in real-time. Following different characterization experiments, the Cu(II)-imprinted plasmonic sensor was employed for kinetic, selectivity, and reusability studies. According to the results, it was observed that this sensor can measure with 96% accuracy in the Cu(II) concentration range of 0.04-5 μM in buffer solution. The limit of detection and limit of quantification values were computed as 0.027 µM and 0.089 µM. The results also showed that this plasmonic sensor works successfully not only in a buffer solution but also in complex media such as plasma and urine.
Collapse
Affiliation(s)
- Zeynep Gerdan
- Graduate School of Biomedical Engineering, Istanbul University-Cerrahpaşa, Istanbul 34320, Turkey;
| | - Yeşeren Saylan
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey;
| | - Mukden Uğur
- Department of Robotics and Intelligent Systems, Institute of Science, Turkish German University, Istanbul 34820, Turkey;
| | - Adil Denizli
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey;
| |
Collapse
|
6
|
Erbaş A, Inci F. The Role of Ligand Rebinding and Facilitated Dissociation on the Characterization of Dissociation Rates by Surface Plasmon Resonance (SPR) and Benchmarking Performance Metrics. Methods Mol Biol 2022; 2385:237-253. [PMID: 34888723 DOI: 10.1007/978-1-0716-1767-0_11] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Surface plasmon resonance (SPR) is a real-time kinetic measurement principle that can probe the kinetic interactions between ligands and their binding sites, and lies at the backbone of pharmaceutical, biosensing, and biomolecular research. The extraction of dissociation rates from SPR-response signals often relies on several commonly adopted assumptions, one of which is the exponential decay of the dissociation part of the response signal. However, certain conditions, such as high density of binding sites or high concentration fluctuations near the surface as compared to the bulk, can lead to non-exponential decays via ligand rebinding or facilitated dissociation. Consequently, fitting the data with an exponential function can underestimate or overestimate the measured dissociation rates. Here, we describe a set of alternative fit functions that can take such effects into consideration along with plasmonic sensor design principles with key performance metrics, thereby suggesting methods for error-free high-precision extraction of the dissociation rates.
Collapse
Affiliation(s)
- Aykut Erbaş
- UNAM-National Nanotechnology Research Center and Institute of Materials Science Nanotechnology, Bilkent University, Ankara, Turkey.
| | - Fatih Inci
- UNAM-National Nanotechnology Research Center and Institute of Materials Science Nanotechnology, Bilkent University, Ankara, Turkey.
| |
Collapse
|
7
|
Yasmeen N, Etienne M, Sharma PS, El-Kirat-Chatel S, Helú MB, Kutner W. Molecularly imprinted polymer as a synthetic receptor mimic for capacitive impedimetric selective recognition of Escherichia coli K-12. Anal Chim Acta 2021; 1188:339177. [PMID: 34794582 DOI: 10.1016/j.aca.2021.339177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 10/02/2021] [Accepted: 10/13/2021] [Indexed: 11/28/2022]
Abstract
We fabricated an electrochemical molecularly imprinted polymer (MIP) chemosensor for rapid identification and quantification of E. coli strain using 2-aminophenyl boronic acid as the functional monomer. This strain is a modified Gram-negative strain of Escherichia coli bacterium, an ordinary human gut component. The E. coli strongly interacts with a boronic acid because of porous and flexible polymers of the cell wall. The SEM imaging showed that the bacteria template was partially entrapped within the polymeric matrix in a single step. Moreover, this imaging confirmed E. coli K-12 cell template extraction effectiveness. The prepared MIP determined the E. coli K-12 strain up to 2.9 × 104 cells mL-1. The interference study performed in the presence of E. coli variants expressing different surface appendages (type 1 fimbriae or Antigen 43 protein) or Shewanella oneidensis MR1, another Gram-negative bacteria, demonstrated that the bacterial surface composition notably impacts sensing properties of the bacteria imprinted polymer.
Collapse
Affiliation(s)
- Nabila Yasmeen
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224, Warsaw, Poland
| | - Mathieu Etienne
- Université de Lorraine, CNRS, LCPME, F-54000, Nancy, France.
| | - Piyush Sindhu Sharma
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224, Warsaw, Poland.
| | | | | | - Wlodzimierz Kutner
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224, Warsaw, Poland; Faculty of Mathematics and Natural Sciences, School of Sciences, Institute of Chemical Sciences, Cardinal Stefan Wyszynski University in Warsaw, Wóycickiego 1/3, 01-815, Warsaw, Poland
| |
Collapse
|
8
|
A Potentiometric Electronic Tongue as a Discrimination Tool of Water-Food Indicator/Contamination Bacteria. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9060143] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Microorganism assessment plays a key role in food quality and safety control but conventional techniques are costly and/or time consuming. Alternatively, electronic tongues (E-tongues) can fulfill this critical task. Thus, a potentiometric lab-made E-tongue (40 lipid sensor membranes) was used to differentiate four common food contamination bacteria, including two Gram positive (Enterococcus faecalis, Staphylococcus aureus) and two Gram negative (Escherichia coli, Pseudomonas aeruginosa). Principal component analysis and a linear discriminant analysis-simulated annealing algorithm (LDA-SA) showed that the potentiometric signal profiles acquired during the analysis of aqueous solutions containing known amounts of each studied bacteria allowed a satisfactory differentiation of the four bacterial strains. An E-tongue-LDA-SA model (12 non-redundant sensors) correctly classified 98 ± 5% of the samples (repeated K-fold-CV), the satisfactory performance of which can be attributed to the capability of the lipid membranes to establish electrostatic interactions/hydrogen bonds with hydroxyl, amine and/or carbonyl groups, which are comprised in the bacteria outer membranes. Furthermore, multiple linear regression models, based on selected subsets of E-tongue sensors (12–15 sensors), also allowed quantifying the bacteria contents in aqueous solutions (0.993 ± 0.011 ≤ R2 ≤ 0.998 ± 0.005, for repeated K-fold-CV). In conclusion, the E-tongue could be of great value as a preliminary food quality and safety diagnosis tool.
Collapse
|
9
|
Quartz Crystal Microbalance (QCM) Based Biosensor Functionalized by HER2/neu Antibody for Breast Cancer Cell Detection. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9040080] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
The heterogeneity and metastatic features of cancer cells lead to a great number of casualties in the world. Additionally, its diagnosis as well as its treatment is highly expensive. Therefore, development of simple but effective diagnostic systems which detect the molecular markers of cancer is of great importance. The molecular changes on cancer cell membranes serve as targets, such as HER2/neu receptor which is detected on the surface of highly metastatic breast cancer cells. We have aimed to develop a specific and simple quartz crystal microbalance (QCM)-based system to identify HER2/neu expressing breast cancer cells via a receptor-specific monoclonal antibody. First, the QCM chip was coated with polymeric nanoparticles composed of hydroxyethylmethacrylate (HEMA) and ethylene glycol dimethacrylate (EDMA). The nanoparticle coated QCM chip was then functionalized by binding of HER2/neu antibody. The breast cancer cells with/without HER2/neu receptor expression, namely, SKBR3, MDA-MB 231 and also mouse fibroblasts were passed over the chip at a rate of 10–500 cells/mL and the mass changes (Δm) on cell/cm2 unit surface of sensor were detected in real-time. The detection limit of the system was 10 cells/mL. Thus, this QCM-based HER2/neu receptor antibody functionalized system might be used effectively in the detection of HER2/neu expressing SKBR3 breast cancer cells.
Collapse
|
10
|
Öztürk G, Saylan Y, Denizli A. Designing composite cryogel carriers for tyrosine adsorption. Sep Purif Technol 2021. [DOI: 10.1016/j.seppur.2020.117622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Saylan Y, Akgönüllü S, Denizli A. Plasmonic Sensors for Monitoring Biological and Chemical Threat Agents. BIOSENSORS-BASEL 2020; 10:bios10100142. [PMID: 33076308 PMCID: PMC7602421 DOI: 10.3390/bios10100142] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 10/09/2020] [Accepted: 10/11/2020] [Indexed: 02/07/2023]
Abstract
Sensors are excellent options owing to their ability to figure out a large number of problems and challenges in several areas, including homeland security, defense, medicine, pharmacology, industry, environment, agriculture, food safety, and so on. Plasmonic sensors are used as detection devices that have important properties, such as rapid recognition, real-time analysis, no need labels, sensitive and selective sensing, portability, and, more importantly, simplicity in identifying target analytes. This review summarizes the state-of-art molecular recognition of biological and chemical threat agents. For this purpose, the principle of the plasmonic sensor is briefly explained and then the use of plasmonic sensors in the monitoring of a broad range of biological and chemical threat agents is extensively discussed with different types of threats according to the latest literature. A conclusion and future perspectives are added at the end of the review.
Collapse
|
12
|
Saylan Y, Erdem Ö, Inci F, Denizli A. Advances in Biomimetic Systems for Molecular Recognition and Biosensing. Biomimetics (Basel) 2020; 5:biomimetics5020020. [PMID: 32408710 PMCID: PMC7345028 DOI: 10.3390/biomimetics5020020] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 04/29/2020] [Accepted: 05/04/2020] [Indexed: 12/12/2022] Open
Abstract
Understanding the fundamentals of natural design, structure, and function has pushed the limits of current knowledge and has enabled us to transfer knowledge from the bench to the market as a product. In particular, biomimicry―one of the crucial strategies in this respect―has allowed researchers to tackle major challenges in the disciplines of engineering, biology, physics, materials science, and medicine. It has an enormous impact on these fields with pivotal applications, which are not limited to the applications of biocompatible tooth implants, programmable drug delivery systems, biocompatible tissue scaffolds, organ-on-a-chip systems, wearable platforms, molecularly imprinted polymers (MIPs), and smart biosensors. Among them, MIPs provide a versatile strategy to imitate the procedure of molecular recognition precisely, creating structural fingerprint replicas of molecules for biorecognition studies. Owing to their affordability, easy-to-fabricate/use features, stability, specificity, and multiplexing capabilities, host-guest recognition systems have largely benefitted from the MIP strategy. This review article is structured with four major points: (i) determining the requirement of biomimetic systems and denoting multiple examples in this manner; (ii) introducing the molecular imprinting method and reviewing recent literature to elaborate the power and impact of MIPs on a variety of scientific and industrial fields; (iii) exemplifying the MIP-integrated systems, i.e., chromatographic systems, lab-on-a-chip systems, and sensor systems; and (iv) closing remarks.
Collapse
Affiliation(s)
- Yeşeren Saylan
- Department of Chemistry, Hacettepe University, 06800 Ankara, Turkey;
| | - Özgecan Erdem
- Department of Biology, Hacettepe University, 06800 Ankara, Turkey;
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara, Turkey;
| | - Fatih Inci
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara, Turkey;
- Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara, Turkey
| | - Adil Denizli
- Department of Chemistry, Hacettepe University, 06800 Ankara, Turkey;
- Correspondence:
| |
Collapse
|
13
|
The Use of Aptamers and Molecularly Imprinted Polymers in Biosensors for Environmental Monitoring: A Tale of Two Receptors. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8020032] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Effective molecular recognition remains a major challenge in the development of robust receptors for biosensing applications. Over the last three decades, aptamers and molecularly imprinted polymers (MIPs) have emerged as the receptors of choice for use in biosensors as viable alternatives to natural antibodies, due to their superior stability, comparable binding performance, and lower costs. Although both of these technologies have been developed in parallel, they both suffer from their own unique problems. In this review, we will compare and contrast both types of receptor, with a focus on the area of environmental monitoring. Firstly, we will discuss the strategies and challenges involved in their development. We will also discuss the challenges that are involved in interfacing them with the biosensors. We will then compare and contrast their performance with a focus on their use in the detection of environmental contaminants, namely, antibiotics, pesticides, heavy metals, and pathogens detection. Finally, we will discuss the future direction of these two technologies.
Collapse
|
14
|
Özgür E, Topçu AA, Yılmaz E, Denizli A. Surface plasmon resonance based biomimetic sensor for urinary tract infections. Talanta 2020; 212:120778. [PMID: 32113541 DOI: 10.1016/j.talanta.2020.120778] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 01/17/2020] [Accepted: 01/22/2020] [Indexed: 02/08/2023]
Abstract
Tailor-made Escherichia coli (E. coli) receptors were created with microcontact imprinted technique and binding events of E. coli were carried out by a surface plasmon resonance (SPR) sensor in aqueous solution and in urine mimic in real time and label-free. N-methacryloyl-(l)-histidine methyl ester (MAH) was selected as a functional monomer to design tailor-made E. coli receptors on the polymeric film and during the formation of the polymeric film on a chip surface, Ag nanoparticles (AgNPs) were entrapped into the polymer mixture in order to lower the detection limit of biomimetic SPR based sensor. The polymeric film was characterized with atomic force microscopy (AFM), scanning electron microscopy (SEM), ellipsometer and contact angle measurements. Limit of detection (LOD) was found 0.57 CFU/mL and feasibility of the biomimetic sensor was investigated in urine mimic.
Collapse
Affiliation(s)
- Erdoğan Özgür
- Advanced Technologies Application and Research Center, Hacettepe University, Ankara, Turkey
| | | | - Erkut Yılmaz
- Department of Molecular Biology and Biotechnology, Aksaray University, Aksaray, Turkey
| | - Adil Denizli
- Department of Chemistry, Hacettepe University, Ankara, Turkey.
| |
Collapse
|
15
|
Abstract
A smart city has a bright and sustainable way to integrate services together and can monitor/control them using intelligent devices called sensors to preserve the efficient utilization of resources. Sensors are distributed everywhere in smart cities. They can be employed to monitor health care, transportation, infrastructure, building, surveillance, government, etc. Especially, nanosensors hold great impact to turn the current techniques for the detection of viruses. With the facility of real-time sensing, there is no need for regular inspections for maintenance and surveying, which results in reduced costs and time wastage. Definitely, common sensing platforms need persistent updates to address increasing doubts in the detection of viruses as they modify quickly and spread from person to person, pointing the urgency of early detection. In this chapter the introduction is briefly described in Section 30.1. The fundamental of nanosensors is explained in Section 30.2. The significance and applications of nanosensors in virus detection are extensively discussed in Sections 30.3 and 30.4. Section 30.5 consists of various challenges and outlook.
Collapse
|