1
|
Bayat A, Dondapati JS, Ahmed SR, Srinivasan S, Rajabzadeh AR. Electrochemical detection of 4(5)-methylimidazole in aqueous solutions. Food Chem 2024; 450:139320. [PMID: 38640530 DOI: 10.1016/j.foodchem.2024.139320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 03/22/2024] [Accepted: 04/08/2024] [Indexed: 04/21/2024]
Abstract
4(5)-methylimidazole (4-MeI) is a potential carcinogen widely used in food colours. EU regulations specify a maximum allowable concentration of 200 ppm for 4-MeI in caramel colours. This study reports an electrochemical determination technique for 4-MeI in caramel colours for the first time. The effect of pH and interference from air were studied to optimize the detection conditions on a glassy carbon electrode in aqueous alkaline solutions using square wave voltammetry (SWV) technique. The concentration of 4-MeI was quantitatively measured down to 10 μM (∼0.8 ppm). Traditional methods such as HPLC, GC, spectrometry and immunoassays involve either expensive instrumentation and reagents or time consuming preparation and detection processes. This study demonstrates the possibility of rapid and simple electrochemical determination of (4-MeI) in food colours with minimum workup using a portable potentiostat.
Collapse
Affiliation(s)
- Akhtar Bayat
- W. Booth School of Engineering Practice & Technology, McMaster University, Hamilton, Ontario L8S 4L8, Canada
| | - Jesse Smiles Dondapati
- W. Booth School of Engineering Practice & Technology, McMaster University, Hamilton, Ontario L8S 4L8, Canada
| | - Syed Rahin Ahmed
- W. Booth School of Engineering Practice & Technology, McMaster University, Hamilton, Ontario L8S 4L8, Canada
| | - Seshasai Srinivasan
- W. Booth School of Engineering Practice & Technology, McMaster University, Hamilton, Ontario L8S 4L8, Canada.
| | - Amin Reza Rajabzadeh
- W. Booth School of Engineering Practice & Technology, McMaster University, Hamilton, Ontario L8S 4L8, Canada.
| |
Collapse
|
2
|
Nascimento LES, Thapa B, Oliveira WDS, Rodrigues PR, Godoy HT, Anderson JL. Multivariate optimization for extraction of 2-methylimidazole and 4-methylimidazole from açaí-based food products using polymeric ionic liquid-based sorbent coatings in solid-phase microextraction coupled to gas chromatography-mass spectrometry. Food Chem 2024; 444:138593. [PMID: 38310774 DOI: 10.1016/j.foodchem.2024.138593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 01/23/2024] [Accepted: 01/24/2024] [Indexed: 02/06/2024]
Abstract
In this study, polymeric ionic liquids featuring different functional moieties were applied as sorbent coatings in direct-immersion solid-phase microextraction (DI-SPME) for the extraction of 2-methylimidazole (2-MI) and 4-methylimidazole (4-MI) from açaí-based food products followed by gas chromatography-mass spectrometry (GC-MS) analysis. The analytical method was optimized using a sequential experimental design. Variables used in GC-MS such as desorption time, as well as for SPME-DI, including extraction time, extraction temperature, incubation time of extraction, amount of NaCl in the extract, and stirring rate, were optimized. The fitness-for-purpose of the method was verified by the linearity of matrix-matched calibration curves (R2 ≥ 0.9921), adequate recoveries (81.7-89.7 %), and precision (relative standard deviations ≤11.2 %). The method was applied to twenty-five samples of açaí-based food products. 4-MI was found in four samples whereas 2-MI was not detected above the limit of detection. The method was found to be suitable for quality control analysis.
Collapse
Affiliation(s)
- Luis Eduardo Silva Nascimento
- Department of Food Science and Nutrition, School of Food Engineering, University of Campinas (UNICAMP), Rua Monteiro Lobato, 80, 13083-862, Campinas, SP, Brazil; Department of Chemistry, Iowa State University, 2415 Osborn Drive, Ames, IA 50011, USA
| | - Bhawana Thapa
- Department of Chemistry, Iowa State University, 2415 Osborn Drive, Ames, IA 50011, USA
| | - Wellington da Silva Oliveira
- Reference Laboratory for Physical, Sensory and Statistics Analysis, Science and Food Quality Center, Institute of Food Technology (ITAL), Avenida Brasil 2880, 13070-178 Campinas, Sao Paulo, Brazil
| | - Plínio Ribeiro Rodrigues
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo (USP), Avenida Lineu Prestes, 748, 05508-000, Cidade Universitária, São Paulo, SP, Brazil
| | - Helena Teixeira Godoy
- Department of Food Science and Nutrition, School of Food Engineering, University of Campinas (UNICAMP), Rua Monteiro Lobato, 80, 13083-862, Campinas, SP, Brazil
| | - Jared L Anderson
- Department of Chemistry, Iowa State University, 2415 Osborn Drive, Ames, IA 50011, USA.
| |
Collapse
|
3
|
Zhang Z, Chen Y, Deng P, He Z, Qin F, Chen Q, Wang Z, Pan H, Chen J, Zeng M. Research progress on generation, detection and inhibition of multiple hazards - acrylamide, 5-hydroxymethylfurfural, advanced glycation end products, methylimidazole - in baked goods. Food Chem 2024; 431:137152. [PMID: 37603996 DOI: 10.1016/j.foodchem.2023.137152] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 08/04/2023] [Accepted: 08/11/2023] [Indexed: 08/23/2023]
Abstract
While baking produces attractive flavors for foods, it also generates various endogenous by-products, including acrylamide (AA), 5-hydroxymethylfurfural (5-HMF), advanced glycation end products (AGEs) and methylimidazole (MI). This review briefly presents the recent studies on the above hazards, and research progress on the formation and control of the above substances in detail. There have been more detailed studies on a single category of hazards. However, few studies and reports have considered the integrated prevention and control of multiple hazards, which is related to the difficulty of analyzing the reaction mechanisms of multiple hazards at multiple scales and under multiple phases in complex food matrices. In this regard, the sample pretreatment methods are a crucial step in achieving simultaneous detection. The coordinated implementation of various methods, including reducing precursor levels, modifying baking conditions and equipment, and incorporating exogenous additives, is necessary to achieve a synchronized reduction in multiple hazardous substances.
Collapse
Affiliation(s)
- Zening Zhang
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China
| | - Yang Chen
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China
| | - Peng Deng
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China
| | - Zhiyong He
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China
| | - Fang Qin
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China
| | - Qiuming Chen
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China
| | - Zhaojun Wang
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China
| | - Hongyang Pan
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China
| | - Jie Chen
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China
| | - Maomao Zeng
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China.
| |
Collapse
|
4
|
Su R, Xiao X, Li G. Thermosensitive poly(N-isopropylacrylamide) hydrogel/highly internal phase emulsion porous polymer tube tip solid-phase extraction for the determination of methylimidazoles in beverage. J Chromatogr A 2023; 1712:464476. [PMID: 37924617 DOI: 10.1016/j.chroma.2023.464476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 10/23/2023] [Accepted: 10/26/2023] [Indexed: 11/06/2023]
Abstract
Poly(N-isopropylacrylamide) thermosensitive hydrogel tube tip solid-phase extraction/ultra-high liquid chromatography-mass spectrometry (UPLC-MS/MS) method was developed for analysis of methylimidazoles in beverages. Thermosensitive poly(N-isopropylacrylamide) (PNIPA) hydrogel solid-phase extraction (SPE) medium was prepared on the surface of highly internal phase emulsion (HIPE) porous polymer by thermally initiated polymerization in a tube tip. The temperature sensitive SPE medium has the characteristics of high porosity and high specific surface area. When the temperature is higher than 30.0℃, it can well adsorb polar molecular, and could quickly desorb polar molecular when the temperature was less than 20.0℃. The tube tip SPE coupled with UPLC-MS/MS method was established for the determination of three polar molecules including 1-methylimidazole, 4-methylimidazole and 2-methylimidazole, with linear ranges of 2.50 - 240 μg/L, and detection limits of 1.20, 1.20 and 0.65 μg/L, respectively. The method was applied to the determination of three methylimidazoles in beverages with the spiked recoveries of 81.5%-115.5% and the RSD of 0.6%-5.0%, and the relative errors of the results with the national standard UPLC-MS/MS method were in the range of -8.5%-8.9%.
Collapse
Affiliation(s)
- Rihui Su
- School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China
| | - Xiaohua Xiao
- School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China.
| | - Gongke Li
- School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China.
| |
Collapse
|
5
|
Akbari N, Shafaroodi H, Jahanbakhsh M, Sabah S, Molaee- aghaee E, Sadighara P. 4-Methylimidazole, a carcinogenic component in food, amount, methods used for measurement; a systematic review. Food Chem X 2023; 18:100739. [PMID: 37397204 PMCID: PMC10314196 DOI: 10.1016/j.fochx.2023.100739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 05/25/2023] [Accepted: 06/02/2023] [Indexed: 07/04/2023] Open
Abstract
4-methylimidazole (4-MEI) is widely used industrially. This carcinogenic component has been reported in some types of food. It is usually produced by the caramelization process in food, drinks and caramel coloring. The possible mechanism for the formation of this compound in food is the Maillard reaction. In order to estimate the amount of substance 4-MEI in food, a systematic study was conducted. The selected keywords were 4-methylimidazole, 4-MEI, beverage, drink, meat, milk, and coffee. 144 articles were obtained from the initial search. The articles were evaluated and finally, the data of 15 manuscripts were extracted. Based on the data extracted from selected articles, the highest amount is reported in caramel color, coffee, and cola drinks. In 70% of the selected studies, the analytical method was based on liquid chromatography. In this method, there is no need for derivatization. SPE columns were used to extract samples in most manuscripts. According to per capita consumption, the most exposure to 4-MEI is through coffee. In high risk food products, regular monitoring with analytical methods with high sensitivity is recommended. Furthermore, most of the selected studies were about the validation method, so few samples were selected. It is recommended to design more studies with a high sample size to accurately evaluate this carcinogenic compound in food.
Collapse
Affiliation(s)
- Nader Akbari
- Department of Environmental Health, Food Safety Division, Faculty of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| | - Hamed Shafaroodi
- Department of Pharmacology, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Mahdi Jahanbakhsh
- Department of Environmental Health, Food Safety Division, Faculty of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| | - Samireh Sabah
- Food and Drug Administration, Ministry of Health and Medical Education, Tehran, Iran
| | - Ebrahim Molaee- aghaee
- Department of Environmental Health, Food Safety Division, Faculty of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| | - Parisa Sadighara
- Department of Environmental Health, Food Safety Division, Faculty of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
6
|
Development of On-Site Rapid Detection Device for Soil Macronutrients Based on Capillary Electrophoresis and Capacitively Coupled Contactless Conductivity Detection (C4D) Method. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10020084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The acquisition of nutrient data on a precise scale has played a vital role in nutrient management processes for soils. However, the lack of rapid precise and multi-index detection techniques for soil macronutrient contents hinders both rational fertilization and cost reduction. In this paper, a rapid detection method and device were devised, combining capillary electrophoresis (CE) and capacitively coupled contactless conductivity detection (C4D), and presented to detect macronutrient contents of soil. The device consisted of a capillary channel, C4D detector, high-voltage system, etc. It separated macronutrient ions using capillary electrophoresis and then measured the ion concentration based on the C4D principle. Lime concretion black soil samples from a complete field were collected and detected. NO3−, NH4+, H2PO4− and K+ in sample solutions could be detected in 5 min with relative standard deviations (RSDs) from 1.0 to 7.51%. The injection voltage was set to 10 kV for 5 s, and the separation voltage was set to 14 kV. This demonstrated the excellent performance of the C4D device on the detection of soil macronutrients, which could help to guide fertilization operations more effectively.
Collapse
|