1
|
Huang Z, Zhou H, Yuan F, Wu J, Yuan S, Cai K, Tao X, Zhang X, Tang C, Chen J. Investigation on the Osteogenic and Antibacterial Properties of Silicon Nitride-Coated Titanium Dental Implants. ACS Biomater Sci Eng 2024; 10:4059-4072. [PMID: 38748565 DOI: 10.1021/acsbiomaterials.4c00427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2024]
Abstract
The silicon nitride (Si3N4) coating exhibits promising potential in oral applications due to its excellent osteogenic and antibacterial properties. However, a comprehensive investigation of Si3N4 coatings in the context of dental implants is still lacking, especially regarding their corrosion resistance and in vivo performance. In this study, Si3N4 coatings were prepared on a titanium surface using the nonequilibrium magnetron sputtering method. A systematic comparison among the titanium group (Ti), Si3N4 coating group (Si3N4-Ti), and sandblasted and acid-etched-treated titanium group (SLA-Ti) has been conducted in vitro and in vivo. The results showed that the Si3N4-Ti group had the best corrosion resistance and antibacterial properties, which were mainly attributed to the dense structure and chemical activity of Si-O and Si-N bonds on the surface. Furthermore, the Si3N4-Ti group exhibited superior cellular responses in vitro and new bone regeneration and osseointegration in vivo, respectively. In this sense, silicon nitride coating shows promising prospects in the field of dental implantology.
Collapse
Affiliation(s)
- Zhiquan Huang
- Jiangsu Key Laboratory of Advanced Metallic Materials, School of Materials Science and Engineering, Southeast University, Nanjing 211189, China
| | - Heyang Zhou
- Department of Dental Implantology, The Affiliated Stomatological Hospital of Nanjing Medical University, Nanjing 210029, China
- Jiangsu Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing 210029, China
| | - Fang Yuan
- Department of Dental Implantology, The Affiliated Stomatological Hospital of Nanjing Medical University, Nanjing 210029, China
- Jiangsu Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing 210029, China
| | - Jin Wu
- Department of Dental Implantology, The Affiliated Stomatological Hospital of Nanjing Medical University, Nanjing 210029, China
- Jiangsu Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing 210029, China
| | - Shanshan Yuan
- Department of Dental Implantology, The Affiliated Stomatological Hospital of Nanjing Medical University, Nanjing 210029, China
- Jiangsu Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing 210029, China
| | - Kunzhan Cai
- Department of Dental Implantology, The Affiliated Stomatological Hospital of Nanjing Medical University, Nanjing 210029, China
- Jiangsu Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing 210029, China
| | - Xiao Tao
- Jiangsu Key Laboratory of Advanced Metallic Materials, School of Materials Science and Engineering, Southeast University, Nanjing 211189, China
| | - Xiyu Zhang
- Jiangsu Key Laboratory of Advanced Metallic Materials, School of Materials Science and Engineering, Southeast University, Nanjing 211189, China
| | - Chunbo Tang
- Department of Dental Implantology, The Affiliated Stomatological Hospital of Nanjing Medical University, Nanjing 210029, China
- Jiangsu Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing 210029, China
| | - Jian Chen
- Jiangsu Key Laboratory of Advanced Metallic Materials, School of Materials Science and Engineering, Southeast University, Nanjing 211189, China
| |
Collapse
|
2
|
Heimann RB. Silicon Nitride Ceramics: Structure, Synthesis, Properties, and Biomedical Applications. MATERIALS (BASEL, SWITZERLAND) 2023; 16:5142. [PMID: 37512416 PMCID: PMC10383158 DOI: 10.3390/ma16145142] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 07/17/2023] [Accepted: 07/18/2023] [Indexed: 07/30/2023]
Abstract
Silicon nitride ceramics excel by superior mechanical, thermal, and chemical properties that render the material suitable for applications in several technologically challenging fields. In addition to high temperature, high stress applications have been implemented in aerospace gas turbines and internal combustion engines as well as in tools for metal manufacturing, forming, and machining. During the past few decades, extensive research has been performed to make silicon nitride suitable for use in a variety of biomedical applications. This contribution discusses the structure-property-application relations of silicon nitride. A comparison with traditional oxide-based ceramics confirms that the advantageous mechanical and biomedical properties of silicon nitride are based on a high proportion of covalent bonds. The present biomedical applications are reviewed here, which include intervertebral spacers, orthopedic and dental implants, antibacterial and antiviral applications, and photonic parts for medical diagnostics.
Collapse
|
3
|
Skjöldebrand C, Tipper JL, Hatto P, Bryant M, Hall RM, Persson C. Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants. Mater Today Bio 2022; 15:100270. [PMID: 35601891 PMCID: PMC9118168 DOI: 10.1016/j.mtbio.2022.100270] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 04/09/2022] [Accepted: 04/24/2022] [Indexed: 10/29/2022] Open
Abstract
Hip and knee joint replacements are common and largely successful procedures that utilise implants to restore mobility and relieve pain for patients suffering from e.g. osteoarthritis. However, metallic ions and particles released from both the bearing surfaces and non-articulating interfaces, as in modular components, can cause hypersensitivity and local tissue necrosis, while particles originating from a polymer component have been associated with aseptic loosening and osteolysis. Implant coatings have the potential to improve properties compared to both bulk metal and ceramic alternatives. Ceramic coatings have the potential to increase scratch resistance, enhance wettability and reduce wear of the articulating surfaces compared to the metallic substrate, whilst maintaining overall toughness of the implant ensuring a lower risk of catastrophic failure of the device compared to use of a bulk ceramic. Coatings can also act as barriers to inhibit ion release from the underlying material caused by corrosion. This review aims to provide a comprehensive overview of wear-resistant coatings for joint replacements - both those that are in current clinical use as well as those under investigation for future use. While the majority of coatings belong predominantly in the latter group, a few coated implants have been successfully marketed and are available for clinical use in specific applications. Commercially available coatings for implants include titanium nitride (TiN), titanium niobium nitride (TiNbN), oxidized zirconium (OxZr) and zirconium nitride (ZrN) based coatings, whereas current research is focused not only on these, but also on diamond-like-carbon (DLC), silicon nitride (SiN), chromium nitride (CrN) and tantalum-based coatings (TaN and TaO). The coating materials referred to above that are still at the research stage have been shown to be non-cytotoxic and to reduce wear in a laboratory setting. However, the adhesion of implant coatings remains a main area of concern, as poor adhesion can cause delamination and excessive wear. In clinical applications zirconium implant surfaces treated to achieve a zirconium oxide film and TiNbN coated implants have however been proven comparable to traditional cobalt chromium implants with regards to revision numbers. In addition, the chromium ion levels measured in the plasma of patients were lower and allergy symptoms were relieved. Therefore, coated implants could be considered an alternative to uncoated metal implants, in particular for patients with metal hypersensitivity. There have also been unsuccessful introductions to the market, such as DLC coated implants, and therefore this review also attempts to summarize the lessons learnt.
Collapse
Affiliation(s)
| | - Joanne L. Tipper
- University of Technology Sydney, School of Biomedical Engineering, Sydney, Australia
| | | | - Michael Bryant
- University of Leeds, Department of Mechanical Engineering, Leeds, United Kingdom
| | - Richard M. Hall
- University of Leeds, Department of Mechanical Engineering, Leeds, United Kingdom
| | - Cecilia Persson
- Uppsala University, Department of Materials Science and Engineering, Uppsala, Sweden
| |
Collapse
|
4
|
Luo C, Jiang Y, Liu Y, Wang Y, Sun J, Qian L, Chen L. Role of Interfacial Bonding in Tribochemical Wear. Front Chem 2022; 10:852371. [PMID: 35464217 PMCID: PMC9019232 DOI: 10.3389/fchem.2022.852371] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Accepted: 03/14/2022] [Indexed: 11/13/2022] Open
Abstract
Tribochemical wear of contact materials is an important issue in science and engineering. Understanding the mechanisms of tribochemical wear at an atomic scale is favorable to avoid device failure, improve the durability of materials, and even achieve ultra-precision manufacturing. Hence, this article reviews some of the latest developments of tribochemical wear of typical materials at micro/nano-scale that are commonly used as solid lubricants, tribo-elements, or structural materials of the micro-electromechanical devices, focusing on their universal mechanisms based on the studies from experiments and numerical simulations. Particular focus is given to the fact that the friction-induced formation of interfacial bonding plays a critical role in the wear of frictional systems at the atomic scale.
Collapse
Affiliation(s)
- Chunsheng Luo
- Tribology Research Institute, State Key Laboratory of Traction Power, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
| | - Yilong Jiang
- Tribology Research Institute, State Key Laboratory of Traction Power, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
| | - Yangqin Liu
- Tribology Research Institute, State Key Laboratory of Traction Power, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
| | - Yang Wang
- Tribology Research Institute, State Key Laboratory of Traction Power, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
| | - Junhui Sun
- Tribology Research Institute, State Key Laboratory of Traction Power, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou, China
- *Correspondence: Junhui Sun, ; Lei Chen,
| | - Linmao Qian
- Tribology Research Institute, State Key Laboratory of Traction Power, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
- Technology and Equipment of Rail Transit Operation and Maintenance Key Laboratory of Sichuan Province, Southwest Jiaotong University, Chengdu, China
| | - Lei Chen
- Tribology Research Institute, State Key Laboratory of Traction Power, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
- Technology and Equipment of Rail Transit Operation and Maintenance Key Laboratory of Sichuan Province, Southwest Jiaotong University, Chengdu, China
- *Correspondence: Junhui Sun, ; Lei Chen,
| |
Collapse
|
5
|
Tang JF, Huang PY, Lin JH, Liu TW, Yang FC, Chang CL. Microstructure and Antimicrobial Properties of Zr-Cu-Ti Thin-Film Metallic Glass Deposited Using High-Power Impulse Magnetron Sputtering. MATERIALS 2022; 15:ma15072461. [PMID: 35407795 PMCID: PMC8999468 DOI: 10.3390/ma15072461] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 03/25/2022] [Accepted: 03/25/2022] [Indexed: 02/01/2023]
Abstract
Zr-Cu based thin-film metallic glass (TFMG) has good glass-forming ability and the addition of a third element can create a chaotic system capable of inhibiting the nucleation and growth of crystals. This study focused on TFMGs made with Zr, Cu, and Ti in various compositions deposited via high-impulse magnetron sputtering on silicon and 304 stainless-steel substrates. Detailed analysis was performed on the microstructure and surface characteristics of the resulting coatings. Transmission electron microscopy revealed that the multilayer structure changed to a nanocrystalline structure similar to an amorphous coating. The excellent hydrophobicity of Zr-Cu-Ti TFMGs can be attributed to their ultra-smooth surface without any grain boundaries. The excellent antimicrobial effects can be attributed to a hydrophobic surface resisting cell adhesion and the presence of copper ions, which are lethal to microbes.
Collapse
Affiliation(s)
- Jian-Fu Tang
- Department of Electro-Optical Engineering, National Taipei University of Technology, Taipei City 106, Taiwan; (J.-F.T.); (J.-H.L.)
| | - Po-Yuan Huang
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 243, Taiwan; (P.-Y.H.); (T.-W.L.)
| | - Ja-Hon Lin
- Department of Electro-Optical Engineering, National Taipei University of Technology, Taipei City 106, Taiwan; (J.-F.T.); (J.-H.L.)
| | - Ting-Wei Liu
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 243, Taiwan; (P.-Y.H.); (T.-W.L.)
| | - Fu-Chi Yang
- Center for Plasma and Thin Film Technologies, Ming Chi University of Technology, New Taipei City 243, Taiwan;
| | - Chi-Lung Chang
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 243, Taiwan; (P.-Y.H.); (T.-W.L.)
- Center for Plasma and Thin Film Technologies, Ming Chi University of Technology, New Taipei City 243, Taiwan;
- Correspondence:
| |
Collapse
|
6
|
Haschke H, Falkenberg A, Morlock MM, Huber G. Do SiNx coatings bear the potential to reduce the risk of micromotion in modular taper junctions? Proc Inst Mech Eng H 2020; 234:897-908. [PMID: 32507037 DOI: 10.1177/0954411920930616] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Fretting corrosion is one contributor to the clinical failure of modular joint arthroplasty. It is initiated by micromotion in metal junctions exposed to fluids. Omitting metal-on-metal contacts could help to reduce the corrosion risk. The coating of one metal taper partner with a ceramic-based silicon nitride (SiNx) coating might provide this separation. The aim of the study was to identify whether a SiNx coating of the male taper component influences the micromotion within a taper junction. Hip prosthesis heads made of CoCr29Mo6 (Aesculap) and Ti6Al4V (Peter Brehm) were assembled (2000 N) to SiNx-coated and uncoated stem tapers made of Ti6Al4V and CoCr29Mo6 (2×2×2 combinations, each n = 4). Consecutive sinusoidal loading representing three daily activities was applied. Contactless relative motion in six degrees of freedom was measured using six eddy-current sensors. Micromotion in the junction was determined by compensating for the elastic deformation derived from additional monoblock measurements. After pull-off, the taper surfaces were microscopically inspected. Micromotion magnitude reached up to 8.4 ± 0.8 µm during loading that represented stumbling. Ti6Al4V stems showed significantly higher micromotion than those made of CoCr29Mo6, while taper coating had no influence. Statistical differences in pull-off forces were found for none of the taper junctions. Microscopy revealed CoCr29Mo6 abrasion from the head taper surface if combined with coated stem tapers. Higher micromotion of Ti6Al4V tapers was probably caused by the lower Young's modulus. Even in the contact areas, the coating was not damaged during loading. The mechanics of coated tapers was similar to uncoated prostheses. Thus, the separation of the two metal surfaces with the objective to reduce in vivo corrosion appears to be achievable if the coating is able to withstand in vivo conditions. However, the hard ceramic-based stem coating lead to undesirable debris from the CoCr29Mo6 heads during loading.
Collapse
Affiliation(s)
- Henning Haschke
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| | - Adrian Falkenberg
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| | - Michael M Morlock
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| | - Gerd Huber
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| |
Collapse
|
7
|
Filho LC, Schmidt S, López A, Cogrel M, Leifer K, Engqvist H, Högberg H, Persson C. The Effect of Coating Density on Functional Properties of SiN x Coated Implants. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E3370. [PMID: 31618981 PMCID: PMC6829552 DOI: 10.3390/ma12203370] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 10/08/2019] [Accepted: 10/12/2019] [Indexed: 11/17/2022]
Abstract
Ceramic coatings may be applied onto metallic components of joint replacements for improved wear and corrosion resistance as well as enhanced biocompatibility, especially for metal-sensitive patients. Silicon nitride (SiNx) coatings have recently been developed for this purpose. To achieve a high coating density, necessary to secure a long-term performance, is however challenging, especially for sputter deposited SiNx coatings, since these coatings are insulating. This study investigates the time-dependent performance of sputter-deposited SiNx based coatings for joint applications. SiNx coatings with a thickness in the range of 4.3-6.0 µm were deposited by reactive high power impulse magnetron sputtering onto flat discs as well as hip heads made of CoCrMo. SiNx compositional analysis by X-ray photoelectron spectroscopy showed N/Si ratios between 0.8 and 1.0. Immersion of the flat disks in fetal bovine serum solution over time as well as short-term wear tests against ultra-high molecular weight polyethylene (UHMWPE) discs showed that a high coating density is required to inhibit tribocorrosion. Coatings that performed best in terms of chemical stability were deposited using a higher target power and process heating.
Collapse
Affiliation(s)
- Luimar Correa Filho
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, 75121 Uppsala, Sweden.
| | - Susann Schmidt
- Thin Film Physics Division, Department of Physics, Chemistry and Biology (IFM), Linköping University, 58183 Linköping, Sweden.
| | - Alejandro López
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, 75121 Uppsala, Sweden.
| | - Mathilde Cogrel
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, 75121 Uppsala, Sweden.
| | - Klaus Leifer
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, 75121 Uppsala, Sweden.
| | - Håkan Engqvist
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, 75121 Uppsala, Sweden.
| | - Hans Högberg
- Thin Film Physics Division, Department of Physics, Chemistry and Biology (IFM), Linköping University, 58183 Linköping, Sweden.
| | - Cecilia Persson
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, 75121 Uppsala, Sweden.
| |
Collapse
|
8
|
Abstract
The Special Issue on Tribology and Surface Engineering includes nine research articles and one review article. It concerns a very important problem of resistance to wear and shaping the properties of the surface layers of different materials by different methods and technologies. The topics of the presented research articles include reactive direct current magnetron sputtering of silicon nitrides on implants, laser surface modification of aeroengine turbine blades, laser micro-texturing of titanium alloy to increase the tribological characteristics, electroplating of Cu–Sn composite coatings incorporated with Polytetrafluoroethylene (PTFE) and TiO2 particles, arc spraying of self-lubricous coatings, high velocity oxygen fuel (HVOF) spraying and gas nitriding of stainless steel coatings, HVOF spraying composite WC-Co coatings, testing of coatings deposited by physical vapour deposition (PVD), and also analysis of material removal and surface creation in wood sanding. The special issue provides valuable knowledge based on theoretical and empirical study in the field of coating technologies, as well as characterization of coatings, and wear phenomena.
Collapse
|