1
|
Juntavee N, Juntavee A, Chansathien O, Prasertcharoensuk N, Leesuraplanon B. Flexural Strength of Different Monolithic Computer-Assisted Design and Computer-Assisted Manufacturing Ceramic Materials Upon Accelerated Aging. Eur J Dent 2024. [PMID: 38744328 DOI: 10.1055/s-0044-1785185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024] Open
Abstract
OBJECTIVES The durability of ceramic is crucial, which is probably influenced by aging. This study evaluated the effect of aging on flexural strength of different ceramics. MATERIALS AND METHODS One-hundred twenty ceramic discs (Ø 12 mm, 1.5 mm thickness) were prepared from zirconia-reinforced lithium silicate (ZLS, C), lithium disilicate (LS2, E), precolored yttria-stabilized tetragonal zirconia polycrystalline (Y-TZP, Ip), and customized color Y-TZP (Ic). Samples were randomly divided into two groups for accelerated aging (A) between 5 and 55°C water baths, 30-second immersing time each, for 10,000 cycles, and nonaged group (N), serving as control. Biaxial flexural strength (σ) was evaluated utilizing the piston-on-three-balls at 0.5 mm/min speed. Analysis of variance and Tukey comparisons were determined for significant differences (α = 0.05). Weibull analysis was applied for survival probability, Weibull modulus (m), and characteristic strength (σo). Microstructures were evaluated with scanning electron microscopy and X-ray diffraction (XRD). RESULTS The highest σ and σo were seen for IcN, followed by IcA, IpN, IpA, EN, CA, CN, and EA, respectively. CN showed the highest m, while EA showed the lowest m. Significant differences of σ for each ceramic were indicated (p < 0.05). Aging caused a significant difference in σ (p < 0.05). XRD showed t→m phase transformation of Ip and Ic after aging. CONCLUSION Aging affected strength of ceramics. Comparable strength between LS2 and ZLS was evidenced, but both were less strength than Y-TZP either aging or non-aging. Comparable strength between precolored Y-TZP and customized color Y-TZP was indicated. Better resisting aging deterioration of Y-TZP than LS2 and ZLS is suggested for fabrication restorative reconstruction.
Collapse
Affiliation(s)
- Niwut Juntavee
- Department of Prosthodontics, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Apa Juntavee
- Division of Pediatric Dentistry, Department of Preventive Dentistry, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Orapun Chansathien
- Division of Biomaterials and Prosthodontics Research, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Natcha Prasertcharoensuk
- Division of Biomaterials and Prosthodontics Research, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Boonsita Leesuraplanon
- Division of Biomaterials and Prosthodontics Research, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| |
Collapse
|
2
|
Li X, Wang Y, Shi G, Lu R, Li Y. Evaluation of natural ageing responses on Burmese amber durability by FTIR spectroscopy with PLSR and ANN models. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 285:121936. [PMID: 36201871 DOI: 10.1016/j.saa.2022.121936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 09/16/2022] [Accepted: 09/26/2022] [Indexed: 06/16/2023]
Abstract
Amber ageing is an inevitable process, which is very important in precious organic gemstone relics protection. In order to explore the mechanism of amber ageing and estimate the durability of Burmese amber, this research investigates the changing spectral features of Burmese ageing amber via Fourier Transform Infrared Spectroscopy (FTIR) and solid 13C Nuclear Magnetic Resonance spectroscopy (NMR) and develops the regression models for its micro-hardness by micro-FTIR spectra. The Partial Least Squares Regression (PLSR) and Artificial Neural Networks (ANN) methods as well as Competitive Adaptive Reweighted Sampling (CARS) algorithm for wavelength variables selection have been applied to predict and assess the Vickers hardness of amber samples with different ageing degrees. As a result, the FTIR and the solid 13C NMR spectra reveal that the contents of CO groups (of esters) increase substantially, and which of the other oxygenic groups (CO (of acids), COC, COCC) increase modestly in amber ageing. When comparing with the results of four different models (PLSR, ANN, CARS-PLSR and CARS-ANN), the CARS-PLSR model obtained the optimal results as follows: the squared correlation coefficient of calibration(R2cal) is 0.9230 and the root mean square error of calibration (RMSEC) is 1.2977 HV; the squared correlation coefficient of prediction (R2pre) is 0.7762 and the root mean square error of prediction (RMSEP) is 2.2208 HV. The overall results sufficiently demonstrate that FTIR spectroscopy technique coupled with appropriate chemometrics methods are very promising tools to estimate and predict the hardness property of Burmese ageing amber.
Collapse
Affiliation(s)
- Xingping Li
- Gemological Institute, China University of Geosciences, Wuhan 430074, China
| | - Yamei Wang
- Gemological Institute, China University of Geosciences, Wuhan 430074, China; Hubei Engineering Research Center of Jewelry, Wuhan 430074, China
| | - Guanghai Shi
- School of Gemology, China University of Geosciences, Beijing 100083, China
| | - Ren Lu
- Gemological Institute, China University of Geosciences, Wuhan 430074, China; Hubei Engineering Research Center of Jewelry, Wuhan 430074, China
| | - Yan Li
- Gemological Institute, China University of Geosciences, Wuhan 430074, China; Hubei Engineering Research Center of Jewelry, Wuhan 430074, China.
| |
Collapse
|
3
|
Singh RG, Lyons KM, Waddell JN, Li KC. Effect of thermocycling on the mechanical properties, inorganic particle release and low temperature degradation of glazed high translucent monolithic 3Y-TZP dental restorations. J Mech Behav Biomed Mater 2022; 136:105495. [PMID: 36208582 DOI: 10.1016/j.jmbbm.2022.105495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 09/27/2022] [Accepted: 09/27/2022] [Indexed: 11/24/2022]
Abstract
The influence of thermocycling on the surface deterioration of glazed monolithic high translucent 3Y-TZP dental restorations is still unclear. The purpose of this study therefore was to evaluate low temperature degradation (LTD), elemental release and surface degradation pattern after five years of simulated clinical time. A total of 123 specimens were prepared from second-generation high translucent 3Y-TZP as per ISO 6872:2015 standards (3 mm × 4 mm × 30 mm). They were classified as per glazing and thermocycling protocol; group CPT, DGT and IGT. Glaze materials were applied on one surface of the specimen and subjected to a thermocycling in artificial saliva, four-point bending test, inductively coupled plasma mass spectrometry (ICP-MS), scanning electron microscopy (SEM), energy dispersive x-ray spectroscopy (EDX) and x-ray diffraction (XRD). Flexural strength, characteristic strength and Weibull modulus values were derived from four-point bending test. Descriptive fractographic analysis of surfaces was conducted to observe the surface degradation characteristics and point of failure. Control/no glaze with thermocycling (CPT = 621.5, 1σ = 117.0 MPa) presented higher flexural strength values compared to glaze I with thermocycling (442.4, 1σ = 45.4 MPa) and glaze II with thermocycling (534.3, 1σ = 46.3 MPa). Characteristic strength from Weibull analysis also observed higher values (669.2 MPa) for the control specimens. XRD analysis showed that monoclinic volume fraction (Vm = 11.0, 1σ = 0.7%) was highest in control specimens. Fractographic analysis suggested that there was no correlation between the point of failure initiation and mean flexural strength values. Glazing protected the high translucent 3Y-TZP surface against LTD during thermocycling but negatively impacted on the flexural strength.
Collapse
Affiliation(s)
- Raj Gaurav Singh
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, New Zealand.
| | - Karl Michael Lyons
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, New Zealand.
| | - John Neil Waddell
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, New Zealand.
| | - Kai Chun Li
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, New Zealand.
| |
Collapse
|
4
|
Impact of thermocycling on surface roughness, microhardness and optical properties of three different lithium disilicate ceramics. Saudi Dent J 2022; 34:589-595. [PMID: 36267536 PMCID: PMC9577348 DOI: 10.1016/j.sdentj.2022.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2022] [Revised: 08/01/2022] [Accepted: 08/08/2022] [Indexed: 11/25/2022] Open
Abstract
Objectives This investigation was carried out to examine the influence of thermocycling aging on the surface roughness (Ra, µm), color parameters (L*, a*, b*), lightness change (ΔL*), chroma change (ΔC*ab), color change (ΔE), and microhardness (VH) of three lithium disilicate ceramics. Materials and methods Forty-five specimens were prepared from three lithium disilicate materials (n = 15)—e.max CAD (EC), e.max Press (EP), and GC Initial LiSi Press (LP) ceramics—with dimensions of 6.0 × 1.2 × 16.0 ± 0.2 mm following the manufacturers’ instructions. All specimens were exposed to 5000 thermal cycles with bath temperatures ranging between 5 °C and 55 °C. Data of surface roughness, color parameters, and microhardness were obtained using an optical profiler, a spectrophotometer, and a Vickers hardness tester, respectively. One-way ANOVA, a post-hoc Tukey’s test, and a paired sample t-test were implemented for statistical analysis (p ≤ 0.05). Results For surface roughness, insignificant differences were reported between the materials either before or after thermocycling (p > 0.05) while each material displayed a significant increase after being subjected to thermocycling (p < 0.05). For color parameters, LP showed significantly lower L* and b* after thermocycling while EC presented a significant reduction in a* in comparison with other materials (p < 0.05). EP showed a significant decrease in ΔL*, ΔC*ab and ΔE compared with other materials (p < 0.05). Regarding microhardness, LP showed significantly increase value in comparison with other materials (p < 0.05). Conclusions Thermocycling had a major impact on the surface roughness, microhardness and optical characteristics of the tested materials. E.max Press displayed less changes in (ΔL*), (ΔC*ab) and (ΔE), while GC LiSi Press had better behavior in terms of microhardness.
Collapse
|
5
|
Fractographic and Microhardness Evaluation of All-Ceramic Hot-Pressed and CAD/CAM Restorations after Hydrothermal Aging. MATERIALS 2022; 15:ma15113987. [PMID: 35683294 PMCID: PMC9182156 DOI: 10.3390/ma15113987] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 05/29/2022] [Accepted: 06/02/2022] [Indexed: 12/04/2022]
Abstract
All-ceramic dental restorations have great advantages, such as highly esthetical properties, a less complex fabrication, and a similar abrasion resistance to enamel. Despite these advantages, ceramic materials are more prone to fracture due to their brittle microstructure. The main aim of this in vitro study was to determine the difference in hot-pressed and milled glass-ceramic mechanical properties such as fracture resistance and microhardness (VHN). Four types of ceramics, two hot-pressed and two milled, feldspathic glass-ceramics and zirconia-reinforced glass-ceramics were selected in this study and tested using the static loading test and Vicker’s testing. Hydrothermal aging, consisting of different baths with temperatures between 5 degrees Celsius and 55 degrees Celsius, was chosen as the in vitro aging method. Statistical analyses are performed using SPSS Statistics software at a significance level of p < 0.05. Micro-hardness values decrease after hydrothermal aging. The static loading test reveals a significant difference between the feldspathic hot-pressed glass-ceramic, which fractures at lower forces, and milled zirconia-reinforced lithium silicate glass-ceramic, which fractures at greater forces (N). Fractographic analysis of the fractured fragments resulted in the static loading test revealing different surface features about the crack origins and propagations under a stereomicroscope.
Collapse
|
6
|
Toma FR, Bîrdeanu MI, Uțu ID, Vasiliu RD, Moleriu LC, Porojan L. Surface Characteristics of High Translucent Multilayered Dental Zirconia Related to Aging. MATERIALS (BASEL, SWITZERLAND) 2022; 15:3606. [PMID: 35629636 PMCID: PMC9144863 DOI: 10.3390/ma15103606] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 05/13/2022] [Accepted: 05/16/2022] [Indexed: 02/06/2023]
Abstract
(1) Background: The purpose of this study was to evaluate the differences in terms of surface characteristics (roughness, topography, microhardness) among layers for multi-layered high translucent and super-high translucent zirconia and the influence of finishing and aging on surface characteristics and microstructure. (2) Methods: Three types of translucent multilayer zirconia were evaluated: STML (4Y-TZP); IPS e.maxZirCAD CEREC/in Lab MT Multi (4Y-TZP + 5Y-TZP); CeramillZolidfx ML (5Y-TZP). Ninety-six plate-shaped samples (32 for a material), 16 mm × 14 mm × 1 mm size, were cut with a precision disc, polished on both sides with sand papers and sintered respecting the manufacturer’s protocol. Half of the specimens (16) were finished by polishing and the other half by glazing and then equally divided into one control group and one group subject to aging by autoclaving (1 h, 134 °C, 0.2 MPa), resulting in four groups of eight samples, for each zirconia. The specimens were evaluated in three areas: cervical, medium, incisal-of each glazed or polished surface, before and after aging. Tests were performed to determine the surface roughness using a profilometer; the surface topography by an atomic force microscope (AFM) and a scanning electron microscope (SEM). Microhardness was recorded using a microhardness tester. Statistical analyses were performed using two-way ANOVA test, unpaired sample t-Test, paired sample t-Test (α = 0.05) and Pearson’s correlation. (3) Results: Before and after autoclaving, for glazed samples significance (p < 0.05) higher surface roughness, respectively lower microhardness in comparison with the polished group was assessed. No significant differences (p > 0.05) were reported between the three areas, on glazed or polished surfaces of a material. Although, after aging an increase in surface roughness was observed both on glazed and polished samples, statistical differences were found for STML (p < 0.05). No significant differences (p> 0.05) concerning microhardness among the same areas, on glazed and polished surfaces, recorded before and after aging, except CeramillZolidfx ML glazed samples. (4) Conclusions: For tested zirconia materials no significant differences among layers were registered regarding surface characteristics. Surface treatment (glazing or polishing) has a significant impact on surface roughness and microhardness. Both before and after aging, the surface roughness values for the glazed samples were higher than for those polished. The super translucent 4Y-TZP material was more affected by aging compared to the super-high translucent 5Y-TZP material. The combined material revealed similarities for each layer corresponding to the microstructure.
Collapse
Affiliation(s)
- Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, EftimieMurgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| | - Mihaela Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| | - Ion-Dragoș Uțu
- Department of Materials and Fabrication Engineering, Politehnica University Timişoara, Bd. Mihai Viteazu nr.1, 300222 Timisoara, Romania;
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, EftimieMurgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| | - Lavinia Cristina Moleriu
- Department of Functional Science, “Victor Babeș” University of Medicine and Pharmacy Timișoara, EftimieMurgu Sq. No. 2, 300041 Timisoara, Romania;
| | - Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, EftimieMurgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| |
Collapse
|
7
|
Surface Characterisation of Dental Resin Composites Related to Conditioning and Finishing. Polymers (Basel) 2021; 13:polym13234236. [PMID: 34883740 PMCID: PMC8659525 DOI: 10.3390/polym13234236] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 11/29/2021] [Accepted: 11/30/2021] [Indexed: 11/16/2022] Open
Abstract
Due to the little information related to surface processing and conditioning of resin matrix ceramic materials previous glazing, the main purpose of this in vitro study was to investigate the effect of different surface treatments on the surface morphology of different resin composite materials. Five types of resin composite CAD-CAM materials: a resin composite ceramic Vita Enamic (E) and four types of nanoparticle-filled resins, like Lava Ultimate (L), Cerasmart (C), Shofu HC (S), Hyramic (H) were taken into consideration. Specimens received the following surface treatment protocols: conventional polishing [p], polishing and glazing [pg], conditioning with CoJet [c], conditioning with CoJet and glazing [cg], sandblasting [s], sandblasting and glazing [sg], etching [e], etching and glazing [eg]. Surface roughness was analyzed for all samples and nanosurface topographic characterization was made by Atomic Force Microscopy. The highest roughness was registered for sandblasted surfaces [s], followed by tribochemical silica airborne particle abrasion [c], and etching [e]. A very strong correlated conditioning behavior of resin nanoceramic materials, like L, C and S samples was found. The microroughness decreased thus [s] > [c] > [e]. These are moderate correlated with H, and are moderate negative correlated to E, where e is more efficient. Three-dimensional images indicated visible grain boundaries after conditioning, for all materials. After polishing and glazing, surfaces became smoother. For all tested conditioning and finishing methods, surface roughness values were within clinically acceptable limits. Finishing by polishing was proved to be a good choice for all materials taken into consideration, polishing and glazing likewise, excepting Hyramic. For Enamic and Shofu HC sandblasting or tribochemical conditioning and glazing and for Hyramic polishing and glazing are not the best options, related to nanoroughness values. Referring to the nanosurface topography, for Enamic, Cerasmart and Hyramic, glazing would be the method of choice, associated with the adequate conditioning method for each material.
Collapse
|
8
|
Porojan L, Toma FR, Vasiliu RD, Topală FI, Porojan SD, Matichescu A. Optical Properties and Color Stability of Dental PEEK Related to Artificial Ageing and Staining. Polymers (Basel) 2021; 13:polym13234102. [PMID: 34883606 PMCID: PMC8658820 DOI: 10.3390/polym13234102] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 11/20/2021] [Accepted: 11/21/2021] [Indexed: 12/11/2022] Open
Abstract
Considering that the processes of PEEK discoloration caused by either intrinsic or extrinsic factors require elucidation, the aim of this study was to investigate the long-term effect of the combined action of ageing and immersing solutions on the optical properties and color stability of PEEK material, related to surface processing (polishing or glazing). (2) Methods: This study aims to determine the influence of different ageing and staining protocols on optical properties, color changes, and surface roughness of a reinforced PEEK material (bioHPP, Bredent, Senden, Germany). For ageing, specimens were submitted to 5000 cycles in a 55 °C bath and a 5 °C bath filled with distilled water. For staining, thermal cycling was performed in a hot coffee bath (55 °C) and a bath filled with distilled water (37 °C) and in a cold juice bath (5 °C) and a bath filled with distilled water (37 °C). Translucency (TP) and opalescence (OP) parameters were determined, the total color change value (ΔΕ*) was calculated, specimens’ surface roughness was analyzed, and statistical analyses were performed. (3) Results: The mean TP values of the studied samples were in the interval of 1.25–3.60, which is lower than those reported for natural teeth or other aesthetic restoration materials. The OP values of PEEK were registered in the range of 0.27–0.75, being also lower than those of natural teeth or other aesthetic restoration materials. OP has a very strong positive relationship with TP. The mean registered Ra values for all subgroups were below 0.13 µm. Artificial ageing and staining in hot coffee proved to increase the roughness values. (4) Conclusions: The glazing of PEEK has a favorable effect on surface roughness and opalescence, irrespective of the artificial ageing or staining protocols. Artificial ageing damages the color stability and roughness of PEEK, regardless of surface processing, and decreases the translucency and opalescence of glazed surfaces. Immersion in hot coffee leads to perceivable discolorations.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania; (L.P.); (F.R.T.)
| | - Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania; (L.P.); (F.R.T.)
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania; (L.P.); (F.R.T.)
- Correspondence:
| | - Florin-Ionel Topală
- Department of Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania;
| | - Sorin Daniel Porojan
- Department of Oral Rehabilitation (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania;
| | - Anamaria Matichescu
- Department of Preventive, Community Dentistry and Oral Health, Faculty of Dental Medicine, “Victor Babes” University of Medicine and Pharmacy Timișoara, 14A Tudor Vladimirescu Ave., 300173 Timisoara, Romania;
| |
Collapse
|
9
|
In Vitro Effect of Acidic Solutions and Sodium Fluoride on Surface Roughness of Two Types of CAD-CAM Dental Ceramics. Int J Dent 2021; 2021:9977993. [PMID: 34341664 PMCID: PMC8325578 DOI: 10.1155/2021/9977993] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 06/12/2021] [Accepted: 07/10/2021] [Indexed: 11/17/2022] Open
Abstract
Objectives This study assessed the effect of immersion in acidic solutions and sodium fluoride on surface roughness of dental ceramics. Materials and Methods 40 blocks of Vitablocs Mark II and IPS e.max CAD (5 × 5 × 3) were prepared. The samples were divided into five groups (n = 8) for immersion in artificial saliva (control), artificially prepared gastric acid, acetic acid, 0.02% sodium fluoride + gastric acid, and 0.02% sodium fluoride + acetic acid. The samples were immersed for 168 hours in the respective solutions except for sodium fluoride, in which the samples were immersed for 69 hours. The surface roughness of samples was measured before and after immersion using a profilometer. The surface roughness changes of three specimens of each group were evaluated by scanning electron microscopy (SEM). Data were analyzed using one-way and two-way ANOVA, Tukey's test, and independent t-test. Results Significant changes were noted in Ra (P=0.002) and Rq (P < 0.0001) in both types of ceramics. The lowest changes in Ra and Rq parameters were seen in artificial saliva and gastric acid and highest changes occurred following immersion in 0.02% sodium fluoride + acetic acid and 0.02% sodium fluoride + gastric acid, respectively. Changes in Rz were also significant following immersion in Vitablocs Mark II (P < 0.05). Immersion in 0.02% sodium fluoride + gastric acid and 0.02% sodium fluoride + acetic acid produced a rougher surface on both types of ceramics (SEM). Conclusion Exposure of Vitablocs Mark II CAD and IPS e.max CAD to 0.02% sodium fluoride + gastric acid and 0.02% sodium fluoride + acetic acid significantly increased their surface roughness, while for Vitablocs Mark II, lager defects were seen on its surface.
Collapse
|
10
|
Porojan L, Vasiliu RD, Porojan SD, Bîrdeanu MI. Surface Quality Evaluation of Removable Thermoplastic Dental Appliances Related to Staining Beverages and Cleaning Agents. Polymers (Basel) 2020; 12:polym12081736. [PMID: 32756439 PMCID: PMC7464035 DOI: 10.3390/polym12081736] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 07/30/2020] [Accepted: 08/01/2020] [Indexed: 01/04/2023] Open
Abstract
(1) Background: Thermoplastic materials are not inert and subject to changes in the oral environment, which affect their surface quality. Color stability and topographic characteristics of clear thermoplastic appliances are critical considerations. The study aimed to evaluate the optical changes and surface topography of different thermoplastic materials related to staining beverages and cleaning agents. (2) Methods: Thermoplastic polyethylene terephthalate glycol (PET-G) material specimens were selected for the study: S (Duran, Scheu-Dental GmbH, Iserlohn, Germany), D (Biolon, Dreve Dentamid GmbH, Unna, Germany), and B (Crystal, Bio Art Dental Equipment, Sao Carlos, Brazil). Four different media were involved for immersion: coffee (C) and black tea (T) at 55 °C, Coca-Cola (K) at 5 °C, and distilled water (W) at 22 °C. As for cleaning, chemical options and mechanical brushing were selected (P-powder, T-tablets, and X-brushing). Color changes, and mean surface roughness were measured at 24 h, 48 h, and after 7 days. Statistical analysis was performed. After the testing period, atomic force microscopy (AFM) analyses and SEM images were registered in order to characterize the surface topography. (3) Results: Quantitative color change evaluations revealed a slight change in color after 24 h and an extremely marked change after 48 h, respective 7 days. Mean roughness values are kept below the clinically acceptable limit of 0.20 µm for all samples. Related to mean nanoroughness values Sa, and 3D evaluations of the surface quality, Biolon samples have demonstrated the most constant behavior, while Crystal samples are visibly influenced by water immersion. Related to the cleaning method, the topography of Duran samples was influenced by mechanical brushing. (4) Conclusions: Nanoscale investigations provided high accuracy and more realistic surface quality examinations of the examined samples compared to profilometry. Both SEM and AFM should be used for a more detailed description of the surface topography.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| | - Roxana-Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
- Correspondence: ; Tel.: +40-745225523
| | - Sorin-Daniel Porojan
- Department of Oral Rehabilitation (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| | - Mihaela-Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| |
Collapse
|
11
|
Porojan L, Vasiliu RD, Bîrdeanu MI, Porojan SD. Surface Characterization and Optical Properties of Reinforced Dental Glass-Ceramics Related to Artificial Aging. Molecules 2020; 25:molecules25153407. [PMID: 32731378 PMCID: PMC7435760 DOI: 10.3390/molecules25153407] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 07/24/2020] [Accepted: 07/26/2020] [Indexed: 11/16/2022] Open
Abstract
The development of various dental glass-ceramic materials and the evolution of novel processing technologies lead to an essential change in the clinical and technical workflow. The long-term success of a dental restoration treatment is defined by its durability, which is directly influenced by the oral environment. This study's purpose was to evaluate the artificial aging behavior of nanostructured, respective microstructured ceramics related to surface topography, roughness, and optical properties. Six monolithic restoration materials were selected: milled lithium disilicate glass-ceramic (LDS-M) MT (medium translucency), hot-pressed lithium disilicate glass-ceramic (LDS-P) MT and HT (high translucency), milled zirconia-reinforced lithium silicate ceramic (ZLS-M) MT and hot-pressed zirconia-reinforced lithium silicate ceramic (ZLS-P) MT and HT, resulting n = 96 surfaces. All the samples were artificially aged by thermal cycling, and all investigations were made before and after thermal cycling. In terms of optical properties, differences recorded between ZLS and LDS ceramics are not significant. Thermal cycling increases the translucency of ZLS and LDS glass-ceramic materials significantly, with the most harmful effect on the pressed and polished samples. Micro- and nano roughness are significantly influenced by in vitro aging and a negative correlation was recorded. Glazed samples are characterized by significant rougher surfaces for all types of materials. On nanolevel, ZLS materials are significantly smoothed by thermal cycling.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| | - Roxana-Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
- Correspondence: ; Tel.: +40-745225523
| | - Mihaela-Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| | - Sorin-Daniel Porojan
- Department of Oral Rehabilitation (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| |
Collapse
|