Simchick G, Allen TJ, Hernando D. Reproducibility of intravoxel incoherent motion quantification in the liver across field strengths and gradient hardware. Magn Reson Med 2024. [PMID: 39119838 DOI: 10.1002/mrm.30237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 06/19/2024] [Accepted: 07/11/2024] [Indexed: 08/10/2024]
Abstract
PURPOSE To evaluate reproducibility and interlobar agreement of intravoxel incoherent motion (IVIM) quantification in the liver across field strengths and MR scanners with different gradient hardware. METHODS Cramer-Rao lower bound optimization was performed to determine optimized monopolar and motion-robust 2D (b-value and first-order motion moment [M1]) IVIM-DWI acquisitions. Eleven healthy volunteers underwent diffusion MRI of the liver, where each optimized acquisition was obtained five times across three MRI scanners. For each data set, IVIM estimates (diffusion coefficient (D), pseudo-diffusion coefficients (d 1 * $$ {d}_1^{\ast } $$ andd 2 * $$ {d}_2^{\ast } $$ ), blood velocity SDs (Vb1 and Vb2), and perfusion fractions [f1 and f2]) were obtained in the right and left liver lobes using two signal models (pseudo-diffusion and M1-dependent physical) with and without T2 correction (fc1 and fc2) and three fitting techniques (tri-exponential region of interest-based full and segmented fitting and blood velocity SD distribution fitting). Reproducibility and interlobar agreement were compared across methods using within-subject and pairwise coefficients of variation (CVw and CVp), paired sample t-tests, and Bland-Altman analysis. RESULTS Using a combination of motion-robust 2D (b-M1) data acquisition, M1-dependent physical signal modeling with T2 correction, and blood velocity SD distribution fitting, multiscanner reproducibility with median CVw = 5.09%, 11.3%, 9.20%, 14.2%, and 12.6% for D, Vb1, Vb2, fc1, and fc2, respectively, and interlobar agreement with CVp = 8.14%, 11.9%, 8.50%, 49.9%, and 42.0%, respectively, was achieved. CONCLUSION Recently proposed advanced IVIM acquisition, signal modeling, and fitting techniques may facilitate reproducible IVIM quantification in the liver, as needed for establishment of IVIM-based quantitative biomarkers for detection, staging, and treatment monitoring of diseases.
Collapse
Affiliation(s)
- Gregory Simchick
- Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Timothy J Allen
- Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Diego Hernando
- Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
2
|
Li XM, Ma FZ, Quan XY, Zhang XC, Xiao BH, Wáng YXJ. Repeatability and reproducibility comparisons of liver IVIM imaging with free-breathing or respiratory-triggered sequences. NMR IN BIOMEDICINE 2024; 37:e5080. [PMID: 38113878 DOI: 10.1002/nbm.5080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 10/26/2023] [Accepted: 11/07/2023] [Indexed: 12/21/2023]
Abstract
For liver intravoxel incoherent motion (IVIM) data acquisition, respiratory-triggering (RT) MRI is commonly used, and there are strong motivations to shorten the scan duration. For the same scan duration, more b values or higher numbers of excitations can be allowed for free-breathing (FB) imaging than for RT. We studied whether FB can be used to replace RT when careful IVIM image acquisition and image processing are conducted. MRI data of 22 healthy participants were acquired using a 3.0 T scanner. Diffusion imaging was based on a single-shot spin-echo-type echo-planar sequence and 16 b values of 0, 2, 4, 7, 10, 15, 20, 30, 46, 60, 72, 100, 150, 200, 400, and 600 s/mm2 . Each subject attended two scan sessions with an interval of 10-20 days. For each scan session, a subject was scanned twice, first with RT and then with FB. The mean image acquisition time was 5.4 min for FB and 10.8 min for RT. IVIM parameters were calculated with bi-exponential model segmented fitting with a threshold b value of 60 s/mm2 , and fitting started from b = 2 s/mm2 . There was no statistically significant difference between IVIM parameters measured with FB imaging or RT imaging. Perfusion fraction ICC (intraclass correlation coefficient) for FB imaging and RT imaging in the same scan session was 0.824. For perfusion fraction, wSD (within-subject standard deviation), BA (Bland-Altman) difference, BA 95% limit, and ICC were 0.022, 0.0001, -0.0635~0.0637, and 0.687 for FB and 0.031, 0.0122, -0.0723~0.0967, and 0.611 for RT. For Dslow (×10-3 s/mm2 ), wSD, BA difference, BA 95% limit, and ICC were 0.057, 0.0268, -0.1258~0.1793, and 0.471 for FB and 0.073, -0.0078, -0.2170-0.2014, and <0.4 for RT. The Dfast coefficient of variation was 0.20 for FB imaging and 0.28 for RT imaging. All reproducibility indicators slightly favored FB imaging.
Collapse
Affiliation(s)
- Xin-Ming Li
- Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Fu-Zhao Ma
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China
| | - Xian-Yue Quan
- Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Xu-Chang Zhang
- Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Ben-Heng Xiao
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China
| | - Yì Xiáng J Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China
| |
Collapse
|
3
|
Lu T, Wang YXJ. Editorial for "Two-Compartment Perfusion MR IVIM Model to Investigate Normal and Pathological Placental Tissue". J Magn Reson Imaging 2024; 59:892-893. [PMID: 37326131 DOI: 10.1002/jmri.28860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 05/09/2023] [Indexed: 06/17/2023] Open
Affiliation(s)
- Tao Lu
- Department of Radiology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China
| | - Yi Xiang J Wang
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
4
|
Vasquez JA, Brown M, Woolsey M, Abdul-Ghani M, Katabathina V, Deng S, Blangero J, Clarke GD. Reproducibility and Repeatability of Intravoxel Incoherent Motion MRI Acquisition Methods in Liver. J Magn Reson Imaging 2024:10.1002/jmri.29249. [PMID: 38240167 PMCID: PMC11258206 DOI: 10.1002/jmri.29249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 01/08/2024] [Accepted: 01/09/2024] [Indexed: 02/07/2024] Open
Abstract
BACKGROUND Intravoxel incoherent motion (IVIM) diffusion weighted MRI (DWI) has potential for evaluating hepatic fibrosis but image acquisition technique influence on diffusion parameter estimation bears investigation. PURPOSE To minimize variability and maximize repeatably in abdominal DWI in terms of IVIM parameter estimates. STUDY TYPE Prospective test-retest and image quality comparison. SUBJECTS Healthy volunteers (3F/7M, 29.9 ± 12.9 years) and Family Study subjects (18F/12M, 51.7 ± 16.7 years), without and with liver steatosis. FIELD STRENGTH/SEQUENCE Abdominal single-shot echo-planar imaging (EPI) and simultaneous multi-slice (SMS) DWI sequences with respiratory triggering (RT), breath-holding (BH), and navigator echo (NE) at 3 Tesla. ASSESSMENT SMS-BH, EPI-NE, and SMS-RT data from twice-scanned healthy volunteers were analyzed using 6 × b-values (0-800 s⋅mm-2 ) and lower (LO) and higher (HI) b-value ranges. Family Study subjects were scanned using SMS and standard EPI sequences. The biexponential IVIM model was used to estimate fast-diffusion coefficient (Df ), fraction of fast diffusion (f), and slow-diffusion coefficient (Ds ). Scan time, estimated signal-to-noise ratio (eSNR), eSNR per acquisition, and distortion ratio were compared. STATISTICAL TESTS Coefficients of variation (CoV) and Bland Altman analyses were performed for test-retest repeatability. Interclass correlation coefficient (ICC) assessed interobserver agreement with P < 0.05 deemed significant. RESULTS Within-subject CoVs among volunteers (N = 10) for f and Ds were lowest in EPI-NE-LO (11.6%) and SMS-RT-HI (11.1%). Inter-observer ICCs for f and Ds were highest for EPI-NE-LO (0.63) and SMS-RT-LO (0.76). Df could not be estimated for most subjects. Estimated eSNR (EPI = 21.9, SMS = 4.7) and eSNR time (EPI = 6.7, SMS = 16.6) were greater for SMS, with less distortion in the liver region (DR-PE: EPI = 23.6, SMS = 13.1). DATA CONCLUSION Simultaneous multislice acquisitions had significantly less variability and higher ICCs of Ds , higher eSNR, less distortion, and reduced scan time compared to EPI. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Juan A. Vasquez
- Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, TX, United States
- Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, United States
| | - Marissa Brown
- Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, TX, United States
- Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, United States
| | - Mary Woolsey
- Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, United States
| | - Mohammad Abdul-Ghani
- Diabetes Division, Department of Medicine, University of Texas Health Science Center at San Antonio, San Antonio, TX, United States
| | - Venkata Katabathina
- Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, TX, United States
| | - Shengwen Deng
- Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, United States
| | - John Blangero
- Department of Human Genetics, School of Medicine, The University of Texas Rio Grande Valley, Brownsville, TX, United States
| | - Geoffrey D. Clarke
- Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, TX, United States
- Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, United States
| |
Collapse
|
5
|
Ma FZ, Wáng YXJ. T2 relaxation time elongation of hepatocellular carcinoma relative to native liver tissue leads to an underestimation of perfusion fraction measured by standard intravoxel incoherent motion magnetic resonance imaging. Quant Imaging Med Surg 2024; 14:1316-1322. [PMID: 38223120 PMCID: PMC10784108 DOI: 10.21037/qims-23-1437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 11/14/2023] [Indexed: 01/16/2024]
Affiliation(s)
- Fu-Zhao Ma
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Yì Xiáng J Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| |
Collapse
|
6
|
Zhang Y, Sheng R, Yang C, Dai Y, Zeng M. The Feasibility of Using Tri-Exponential Intra-Voxel Incoherent Motion DWI for Identifying the Microvascular Invasion in Hepatocellular Carcinoma. J Hepatocell Carcinoma 2023; 10:1659-1671. [PMID: 37799828 PMCID: PMC10547827 DOI: 10.2147/jhc.s433948] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 09/21/2023] [Indexed: 10/07/2023] Open
Abstract
Purpose To assess the effectiveness of tri-exponential Intra-Voxel Incoherent Motion (tri-IVIM) MRI in preoperatively identifying microvascular invasion (MVI) in hepatocellular carcinoma (HCC). Patients and Methods In this prospective study, 67 patients with HCC were included. Metrics from bi-exponential IVIM (bi-IVIM) and tri-IVIM were calculated. Subgroup comparisons were analyzed using the independent Student's t-test or Mann-Whitney U-test. Logistic regression was performed to explore clinical risk factors. Diagnostic performance was assessed using receiver operating characteristic (ROC) curves, calibration curves and decision curve analysis. Results MVI-positive HCCs exhibited significantly lower true diffusion coefficient (Dt) from bi-IVIM, as well as fast-diffusion coefficients (Df) and slow-diffusion coefficients (Ds) from tri-IVIM, compared to MVI-negative HCCs (p < 0.05). Tumor size and alpha-fetoprotein (AFP) were identified as risk factors. The combination of tri-IVIM-derived metrics (Ds and Df) yielded higher diagnostic accuracy (AUC = 0.808) compared to bi-IVIM (AUC = 0.741). A predictive model based on a nomogram was constructed using Ds, Df, tumor size, and AFP, resulting in the highest diagnostic accuracy (AUC = 0.859). Decision curve analysis indicated that the constructed model, provided the highest net benefit by accurately stratifying the risk of MVI, followed by tri-IVIM and bi-IVIM. Conclusion Tri-IVIM can provide information on perfusion and diffusion for evaluating MVI in HCC. Additionally, tri-IVIM outperformed bi-IVIM in identifying MVI-positive HCC. By integrating clinical risk factors and metrics from tri-IVIM, a predictive nomogram exhibited the highest diagnostic accuracy, potentially aiding in the noninvasive and preoperative assessment of MVI.
Collapse
Affiliation(s)
- Yunfei Zhang
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, 200032, People’s Republic of China
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, People’s Republic of China
| | - Ruofan Sheng
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, 200032, People’s Republic of China
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, People’s Republic of China
| | - Chun Yang
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, People’s Republic of China
| | - Yongming Dai
- School of Biomedical Engineering, ShanghaiTech University, Shanghai, 200032, People’s Republic of China
| | - Mengsu Zeng
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, 200032, People’s Republic of China
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, People’s Republic of China
| |
Collapse
|
7
|
Yamada S, Hiratsuka S, Otani T, Ii S, Wada S, Oshima M, Nozaki K, Watanabe Y. Usefulness of intravoxel incoherent motion MRI for visualizing slow cerebrospinal fluid motion. Fluids Barriers CNS 2023; 20:16. [PMID: 36899412 PMCID: PMC9999497 DOI: 10.1186/s12987-023-00415-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 02/15/2023] [Indexed: 03/12/2023] Open
Abstract
BACKGROUND In the cerebrospinal fluid (CSF) dynamics, the pulsations of cerebral arteries and brain is considered the main driving force for the reciprocating bidirectional CSF movements. However, measuring these complex CSF movements on conventional flow-related MRI methods is difficult. We tried to visualize and quantify the CSF motion by using intravoxel incoherent motion (IVIM) MRI with low multi-b diffusion-weighted imaging. METHODS Diffusion-weighted sequence with six b values (0, 50, 100, 250, 500, and 1000 s/mm2) was performed on 132 healthy volunteers aged ≥ 20 years and 36 patients with idiopathic normal pressure hydrocephalus (iNPH). The healthy volunteers were divided into three age groups (< 40, 40 to < 60, and ≥ 60 years). In the IVIM analysis, the bi-exponential IVIM fitting method using the Levenberg-Marquardt algorithm was adapted. The average, maximum, and minimum values of ADC, D, D*, and fraction of incoherent perfusion (f) calculated by IVIM were quantitatively measured in 45 regions of interests in the whole ventricles and subarachnoid spaces. RESULTS Compared with healthy controls aged ≥ 60 years, the iNPH group had significantly lower mean f values in all the parts of the lateral and 3rd ventricles, whereas significantly higher mean f value in the bilateral foramina of Luschka. In the bilateral Sylvian fossa, which contain the middle cerebral bifurcation, the mean f values increased gradually with increasing age, whereas those were significantly lower in the iNPH group. In the 45 regions of interests, the f values in the bilateral foramina of Luschka were the most positively correlated with the ventricular size and indices specific to iNPH, whereas that in the anterior part of the 3rd ventricle was the most negatively correlated with the ventricular size and indices specific to iNPH. Other parameters of ADC, D, and D* were not significantly different between the two groups in any locations. CONCLUSIONS The f value on IVIM MRI is useful for evaluating small pulsatile complex motion of CSF throughout the intracranial CSF spaces. Patients with iNPH had significantly lower mean f values in the whole lateral ventricles and 3rd ventricles and significantly higher mean f value in the bilateral foramina of Luschka, compared with healthy controls aged ≥ 60 years.
Collapse
Affiliation(s)
- Shigeki Yamada
- Department of Neurosurgery, Nagoya City University Graduate School of Medical Science, 1 Kawasumi, Mizuho-Cho, Mizuho-Ku, Nagoya, Aichi, 467-8601, Japan. .,Department of Neurosurgery, Shiga University of Medical Science, Shiga, Japan. .,Normal Pressure Hydrocephalus Center, Rakuwakai Otowa Hospital, Kyoto, Japan. .,Interfaculty Initiative in Information Studies/Institute of Industrial Science, The University of Tokyo, Tokyo, Japan.
| | | | - Tomohiro Otani
- Department of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Osaka, Japan
| | - Satoshi Ii
- Faculty of System Design, Tokyo Metropolitan University, Tokyo, Japan
| | - Shigeo Wada
- Department of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Osaka, Japan
| | - Marie Oshima
- Interfaculty Initiative in Information Studies/Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Kazuhiko Nozaki
- Department of Neurosurgery, Shiga University of Medical Science, Shiga, Japan
| | - Yoshiyuki Watanabe
- Department of Radiology, Shiga University of Medical Science, Shiga, Japan
| |
Collapse
|
8
|
Loh M, Führes T, Stuprich C, Uder M, Saake M, Laun FB. Influence of saturation effects on biexponential liver intravoxel incoherent motion. Magn Reson Med 2023; 90:270-279. [PMID: 36861449 DOI: 10.1002/mrm.29622] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 01/20/2023] [Accepted: 02/07/2023] [Indexed: 03/03/2023]
Abstract
PURPOSE Studies on intravoxel incoherent motion (IVIM) imaging in the liver have been carried out with different acquisition protocols. The number of acquired slices and the distances between slices can influence IVIM measurements due to saturation effects, but these effects have often been disregarded. This study investigated differences in biexponential IVIM parameters between two slice settings. METHODS Fifteen healthy volunteers (21-30 years) were examined at a field strength of 3 T. Diffusion-weighted images of the abdomen were acquired with 16 b values (0-800 s/mm2 ), with four slices for the few slices setting and 24-27 slices for the many slices setting. Regions of interest were manually drawn in the liver. The data were fitted with a monoexponential signal curve and a biexponential IVIM curve, and biexponential IVIM parameters were determined. The dependence on the slice setting was assessed with Student's t test for paired samples (normally distributed IVIM parameters) and the Wilcoxon signed-rank test (non-normally distributed parameters). RESULTS None of the parameters were significantly different between the settings. For few slices and many slices, respectively, the mean values (SDs) for D $$ D $$ were 1.21 μm 2 / ms $$ 1.21{\upmu \mathrm{m}}^2/\mathrm{ms} $$ ( 0.19 μm 2 / ms $$ 0.19\kern0.3em {\upmu \mathrm{m}}^2/\mathrm{ms} $$ ) and 1.20 μm 2 / ms $$ 1.20{\upmu \mathrm{m}}^2/\mathrm{ms} $$ ( 0.11 μm 2 / ms $$ 0.11\kern0.3em {\upmu \mathrm{m}}^2/\mathrm{ms} $$ ); for f $$ f $$ they were 29.7% (6.2%) and 27.7% (3.6%); and for D * $$ {D}^{\ast } $$ they were 8.76 ⋅ 10 - 2 mm 2 / s $$ 8.76\cdot {10}^{-2}{\mathrm{mm}}^2/\mathrm{s} $$ ( 4.54 ⋅ 10 - 2 mm 2 / s $$ 4.54\cdot {10}^{-2}\kern0.3em {\mathrm{mm}}^2/\mathrm{s} $$ ) and 8.71 ⋅ 10 - 2 mm 2 / s $$ 8.71\cdot {10}^{-2}{\mathrm{mm}}^2/\mathrm{s} $$ ( 4.06 ⋅ 10 - 2 mm 2 / s $$ 4.06\cdot {10}^{-2}\kern0.3em {\mathrm{mm}}^2/\mathrm{s} $$ ). CONCLUSION Biexponential IVIM parameters in the liver are comparable among IVIM studies that use different slice settings, with mostly negligible saturation effects. However, this may not hold for studies that use much shorter TR.
Collapse
Affiliation(s)
- Martin Loh
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Tobit Führes
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Christoph Stuprich
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Marc Saake
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Frederik Bernd Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| |
Collapse
|
9
|
Simchick G, Hernando D. Precision of region of interest-based tri-exponential intravoxel incoherent motion quantification and the role of the Intervoxel spatial distribution of flow velocities. Magn Reson Med 2022; 88:2662-2678. [PMID: 35968580 PMCID: PMC9529845 DOI: 10.1002/mrm.29406] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 06/27/2022] [Accepted: 07/18/2022] [Indexed: 11/08/2022]
Abstract
PURPOSE The purpose of this work was to obtain precise tri-exponential intravoxel incoherent motion (IVIM) quantification in the liver using 2D (b-value and first-order motion moment [M1 ]) IVIM-DWI acquisitions and region of interest (ROI)-based fitting techniques. METHODS Diffusion MRI of the liver was performed in 10 healthy volunteers using three IVIM-DWI acquisitions: conventional monopolar, optimized monopolar, and optimized 2D (b-M1 ). For each acquisition, bi-exponential and tri-exponential full, segmented, and over-segmented ROI-based fitting and a newly proposed blood velocity SDdistribution (BVD) fitting technique were performed to obtain IVIM estimates in the right and left liver lobes. Fitting quality was evaluated using corrected Akaike information criterion. Precision metrics (test-retest repeatability, inter-reader reproducibility, and inter-lobar agreement) were evaluated using Bland-Altman analysis, repeatability/reproducibility coefficients (RPCs), and paired sample t-tests. Precision was compared across acquisitions and fitting methods. RESULTS High repeatability and reproducibility was observed in the estimations of the diffusion coefficient (Dtri = [1.03 ± 0.11] × 10-3 mm2 /s; RPCs ≤ 1.34 × 10-4 mm2 /s), perfusion fractions (F1 = 3.19 ± 1.89% and F2 = 16.4 ± 2.07%; RPCs ≤ 2.51%), and blood velocity SDs (Vb,1 = 1.44 ± 0.14 mm/s and Vb,2 = 3.62 ± 0.13 mm/s; RPCs ≤ 0.41 mm/s) in the right liver lobe using the 2D (b-M1 ) acquisition in conjunction with BVD fitting. Using these methods, significantly larger (p < 0.01) estimates of Dtri and F1 were observed in the left lobe in comparison to the right lobe, while estimates of Vb,1 and Vb,2 demonstrated high interlobar agreement (RPCs ≤ 0.45 mm/s). CONCLUSIONS The 2D (b-M1 ) IVIM-DWI data acquisition in conjunction with BVD fitting enables highly precise tri-exponential IVIM quantification in the right liver lobe.
Collapse
Affiliation(s)
- Gregory Simchick
- Radiology, University of Wisconsin-Madison, Madison, WI, United States
- Medical Physics, University of Wisconsin-Madison, Madison, WI, United States
| | - Diego Hernando
- Radiology, University of Wisconsin-Madison, Madison, WI, United States
- Medical Physics, University of Wisconsin-Madison, Madison, WI, United States
| |
Collapse
|
10
|
Troelstra MA, Van Dijk AM, Witjes JJ, Mak AL, Zwirs D, Runge JH, Verheij J, Beuers UH, Nieuwdorp M, Holleboom AG, Nederveen AJ, Gurney-Champion OJ. Self-supervised neural network improves tri-exponential intravoxel incoherent motion model fitting compared to least-squares fitting in non-alcoholic fatty liver disease. Front Physiol 2022; 13:942495. [PMID: 36148303 PMCID: PMC9485997 DOI: 10.3389/fphys.2022.942495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 07/27/2022] [Indexed: 11/13/2022] Open
Abstract
Recent literature suggests that tri-exponential models may provide additional information and fit liver intravoxel incoherent motion (IVIM) data more accurately than conventional bi-exponential models. However, voxel-wise fitting of IVIM results in noisy and unreliable parameter maps. For bi-exponential IVIM, neural networks (NN) were able to produce superior parameter maps than conventional least-squares (LSQ) generated images. Hence, to improve parameter map quality of tri-exponential IVIM, we developed an unsupervised physics-informed deep neural network (IVIM3-NET). We assessed its performance in simulations and in patients with non-alcoholic fatty liver disease (NAFLD) and compared outcomes with bi-exponential LSQ and NN fits and tri-exponential LSQ fits. Scanning was performed using a 3.0T free-breathing multi-slice diffusion-weighted single-shot echo-planar imaging sequence with 18 b-values. Images were analysed for visual quality, comparing the bi- and tri-exponential IVIM models for LSQ fits and NN fits using parameter-map signal-to-noise ratios (SNR) and adjusted R2. IVIM parameters were compared to histological fibrosis, disease activity and steatosis grades. Parameter map quality improved with bi- and tri-exponential NN approaches, with a significant increase in average parameter-map SNR from 3.38 to 5.59 and 2.45 to 4.01 for bi- and tri-exponential LSQ and NN models respectively. In 33 out of 36 patients, the tri-exponential model exhibited higher adjusted R2 values than the bi-exponential model. Correlating IVIM data to liver histology showed that the bi- and tri-exponential NN outperformed both LSQ models for the majority of IVIM parameters (10 out of 15 significant correlations). Overall, our results support the use of a tri-exponential IVIM model in NAFLD. We show that the IVIM3-NET can be used to improve image quality compared to a tri-exponential LSQ fit and provides promising correlations with histopathology similar to the bi-exponential neural network fit, while generating potentially complementary additional parameters.
Collapse
Affiliation(s)
- Marian A. Troelstra
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam, Netherlands
- *Correspondence: Marian A. Troelstra,
| | | | - Julia J. Witjes
- Department of Vascular Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | - Anne Linde Mak
- Department of Vascular Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | - Diona Zwirs
- Department of Vascular Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | - Jurgen H. Runge
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | - Joanne Verheij
- Department of Pathology, Amsterdam UMC, Amsterdam, Netherlands
| | - Ulrich H. Beuers
- Department of Gastroenterology and Hepatology, Amsterdam UMC, Amsterdam, Netherlands
| | - Max Nieuwdorp
- Department of Vascular Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | | | - Aart J. Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | | |
Collapse
|
11
|
Zheng CJ, Xiao BH, Huang H, Zhou N, Yan TY, Wáng YXJ. Bi-exponential fitting excluding b=0 data improves the scan-rescan stability of liver IVIM parameter measures and particularly so for the perfusion fraction. Quant Imaging Med Surg 2022; 12:3288-3299. [PMID: 35655827 PMCID: PMC9131351 DOI: 10.21037/qims-2022-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Accepted: 03/11/2022] [Indexed: 08/30/2023]
Abstract
BACKGROUND A prerequisite to translating intravoxel incoherent motion (IVIM) imaging into meaningful clinical applications is sufficient scan-rescan reproducibility. This study aims to confirm the hypothesis that IVIM data fitting by not using b=0 images will improve the stability of liver IVIM measurement. METHODS Healthy volunteers' liver IVIM images were prospectively acquired using a 1.5-T magnet or a 3.0 T with 16 b-values. Repeatability study subjects were scanned twice during the same session, resulted in 35 paired scans for 35 subjects (11 men, mean age: 41.82 years, range: 32-60 years; 24 women, mean age: 42.67 years, range: 20-71 years). IVIM analysis was performed with full-fitting and segmented-fitting with a threshold b-value of 60 s/mm2, and fitting started from b=0 s/mm2 or from b=2 s/mm2. Reproducibility study subjects were scanned and then rescanned with an interval of 5-18 days, resulted in 20 paired scans for 11 subjects (4 men, mean age: 26.25 years, range: 25-27 years; 7 women, mean age: 25.57 years, range: 24-27 years). IVIM analysis was performed with segmented-fitting with a threshold b-value of 50 s/mm2, and fitting started from b=0 s/mm2 or from b=3 s/mm2. RESULTS Fitting without b=0 data generally improved the repeatability and reproducibility for both PF and Dslow, and particularly so for PF. For with b=0 data segmented fitting repeatability, PF had within-subject standard deviation of 0.019, bland-Atman 75% agreement limit of -31.52% to 28.35%, and ICC of 0.647, while these values were 0.009, -20.78% to 16.86%, and 0.837 for without b=0 analysis. Though the repeatability and reproducibility for Dfast generally also improved, they remained suboptimal. Measurement stability was better for repeatability than for reproducibility. CONCLUSIONS Scan-rescan repeatability and reproducibility of liver IVIM parameters can be improved by fitting without b=0 data, which is particularly so for PF.
Collapse
Affiliation(s)
- Cun-Jing Zheng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Ben-Heng Xiao
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Hua Huang
- Department of Radiology, The Third People’s Hospital of Shenzhen, The Second Affiliated Hospital of Southern University of Science and Technology, National Clinical Research Center for Infectious Diseases, Shenzhen, China
| | - Nan Zhou
- Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
| | - Tai-Yu Yan
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Yì Xiáng J. Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
12
|
Zhou X, Wang X, Liu E, Zhang L, Zhang H, Zhang X, Zhu Y, Kuai Z. An Unsupervised Deep Learning Approach for
Dynamic‐Exponential
Intravoxel Incoherent Motion
MRI
Modeling and Parameter Estimation in the Liver. J Magn Reson Imaging 2022; 56:848-859. [PMID: 35064945 DOI: 10.1002/jmri.28074] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 01/09/2022] [Accepted: 01/10/2022] [Indexed: 12/18/2022] Open
Affiliation(s)
- Xin‐Xiang Zhou
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Xin‐Yu Wang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - En‐Hui Liu
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Lan Zhang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Hong‐Xia Zhang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Xiu‐Shi Zhang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Yue‐Min Zhu
- CREATIS CNRS UMR 5220‐INSERM U1206‐University Lyon 1‐INSA Lyon‐University Jean Monnet Saint‐Etienne Lyon France
| | - Zi‐Xiang Kuai
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| |
Collapse
|
13
|
Usefulness of diffusion derived vessel density computed from a simplified IVIM imaging protocol: An experimental study with rat biliary duct blockage induced liver fibrosis. Magn Reson Imaging 2021; 84:115-123. [PMID: 34619291 DOI: 10.1016/j.mri.2021.09.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 08/23/2021] [Accepted: 09/30/2021] [Indexed: 01/10/2023]
Abstract
OBJECTIVES Liver vessel density can be evaluated by DDVD (diffusion derived vessel density): DDVD(b0b1) = Sb0/ROIarea0 - Sb1/ROIarea1, where Sb0 and Sb1 refer to the liver signal when b is 0 or 1 s/mm2. Sb1 and ROIarea1 may be replaced by other b-values. With a rat biliary duct ligation (BDL) model, this study assesses the usefulness of liver DDVD computed from a simplified IVIM imaging protocol using b = 25 and b = 50 to replace b = 1 s/mm2, alone and in combination with other IVIM parameters. METHODS Male Sprague-Dawley rats were used. The rat number was 5, 5, 5, and 3 respectively, for the timepoints of 7, 14, 21, 28 days post-BDL surgery. 12 rats had partial biliary duct recanalization performed after the rats had BDL for 7 days and then again followed-up for a mean of 14 days. Liver diffusion MRIs were acquired at 3.0 T with a b-value distribution of 0, 25, 50, 75, 100, 150, 300, 700, 1000 s/mm2. DDVDmean (control rats n = 6) was the mean of DDVD(b0b25) and DDVD(b0b50). IVIM fitting started from b = 0 s/mm2 with segmented fitting and a threshold b of 50 s/mm2 (n = 5 for control rats). Three 3-D spaces were constructed using a combination of the four diffusion parameters. RESULTS The control rats and BDL rats (n = 18) had a liver DDVDmean of 84.0 ± 26.2 and 44.7 ± 14.4 au/pixel (p < 0.001). All 3-D spaces totally separated healthy livers and all fibrotic livers (n = 30, BDL rats and recanalization rats). The mean relative distance between healthy liver cluster and fibrotic liver cluster was 0.331 for PF, Dslow, and Dfast; 0.381 for PF, Dfast, and DDVDmean; and 0.384 for PF, Dslow, and DDVDmean. CONCLUSION A combination of PF, Dslow, and Dfast allows total separation of healthy livers and fibrotic livers and the integration of DDVD improved the separation.
Collapse
|
14
|
Wáng YXJ, Xiao BH, Zheng CJ, Li T, Che-Nordin N, Wang W. More promising results of liver intravoxel incoherent motion imaging analysis for the assessment of nonalcoholic steatohepatitis and fibrosis. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1283. [PMID: 34532420 PMCID: PMC8422144 DOI: 10.21037/atm-21-3442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Accepted: 07/26/2021] [Indexed: 11/29/2022]
Affiliation(s)
- Yì Xiáng J Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Ben-Heng Xiao
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Cun-Jing Zheng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Ting Li
- Department of Radiology, The Third Xiangya Hospital, Central South University, Changsha, China
| | - Nazmi Che-Nordin
- College of Health Sciences, Gulf Medical University, Ajman, United Arab Emirates
| | - Wei Wang
- Department of Radiology, The Third Xiangya Hospital, Central South University, Changsha, China
| |
Collapse
|
15
|
Führes T, Riexinger AJ, Loh M, Martin J, Wetscherek A, Kuder TA, Uder M, Hensel B, Laun FB. Echo time dependence of biexponential and triexponential intravoxel incoherent motion parameters in the liver. Magn Reson Med 2021; 87:859-871. [PMID: 34453445 DOI: 10.1002/mrm.28996] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 08/12/2021] [Accepted: 08/12/2021] [Indexed: 11/09/2022]
Abstract
PURPOSE Intravoxel incoherent motion (IVIM) studies are performed with different acquisition protocols. Comparing them requires knowledge of echo time (TE) dependencies. The TE-dependence of the biexponential perfusion fraction f is well-documented, unlike that of its triexponential counterparts f1 and f2 and the biexponential and triexponential pseudodiffusion coefficients D* , D 1 ∗ , and D 2 ∗ . The purpose was to investigate the TE-dependence of these parameters and to check whether the triexponential pseudodiffusion compartments are associated with arterial and venous blood. METHODS Fifteen healthy volunteers (19-58 y; mean: 24.7 y) underwent diffusion-weighted imaging of the abdomen with 24 b-values (0.2-800 s/mm2 ) at TEs of 45, 60, 75, and 90 ms. Regions of interest (ROIs) were manually drawn in the liver. One set of bi- and triexponential IVIM parameters per volunteer and TE was determined. The TE-dependence was assessed with the Kruskal-Wallis test. RESULTS TE-dependence was observed for f (P < .001), f1 (P = .001), and f2 (P < .001). Their median values at the four measured TEs were: f: 0.198/0.240/0.274/0.359, f1 : 0.113/0.139/0.146/0.205, f2 : 0.115/0.155/0.182/0.194. D, D* , D 1 ∗ , and D 2 ∗ showed no significant TE-dependence. Their values were: diffusion coefficient D (10-4 mm2 /s): 9.45/9.63/9.75/9.41, biexponential D* (10-2 mm2 /s): 5.26/5.52/6.13/5.82, triexponential D 1 ∗ (10-2 mm2 /s): 1.73/2.91/2.25/2.51, triexponential D 2 ∗ (mm2 /s): 0.478/1.385/0.616/0.846. CONCLUSION f1 and f2 show similar TE-dependence as f, ie, increase with rising TE; an effect that must be accounted for when comparing different studies. The diffusion and pseudodiffusion coefficients might be compared without TE correction. Because of the similar TE-dependence of f1 and f2 , the triexponential pseudodiffusion compartments are most probably not associated to venous and arterial blood.
Collapse
Affiliation(s)
- Tobit Führes
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Andreas Julian Riexinger
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Martin Loh
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | | | - Andreas Wetscherek
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Tristan Anselm Kuder
- Department of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Bernhard Hensel
- Center for Medical Physics and Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Frederik Bernd Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| |
Collapse
|
16
|
Kobayashi S. Editorial for "Using Intravoxel Incoherent Motion and Dynamic Contrast-Enhanced MR Imaging to Early Detect Tissue Injury and Microcirculation Alteration in Hepatic Injury Induced by Intestinal Ischemia Reperfusion in the Rat Model". J Magn Reson Imaging 2021; 54:761-762. [PMID: 33851479 DOI: 10.1002/jmri.27642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 03/30/2021] [Indexed: 11/09/2022] Open
Affiliation(s)
- Satoshi Kobayashi
- Department of Radiology, Kanazawa University Graduate School of Medical Sciences, Kanazawa, Japan
| |
Collapse
|