Demetriou ZJ, Muñiz-Hernández J, Rosario-Ortiz G, Quiñones FM, Gonzalez-Diaz G, Ramos-Benitez MJ, Mosquera RA, De Jesús-Rojas W. Evaluation of Open-Source Ciliary Analysis Software in Primary Ciliary Dyskinesia: A Comparative Assessment. Diagnostics (Basel) 2024; 14:1814. [PMID: 39202302 PMCID: PMC11354199 DOI: 10.3390/diagnostics14161814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 08/12/2024] [Accepted: 08/19/2024] [Indexed: 09/03/2024] Open
Abstract
Primary Ciliary Dyskinesia (PCD) is a rare genetic disorder characterized by alterations in motile cilia function. The diagnosis of PCD is challenging due to the lack of standardized methods in clinical practice. High-speed video microscopy analysis (HSVA) directly evaluates ciliary beat frequency (CBF) in PCD. Recently, open-source ciliary analysis software applications have shown promise in measuring CBF accurately. However, there is limited knowledge about the performance of different software applications, creating a gap in understanding their comparative effectiveness in measuring CBF in PCD. We compared two open-source software applications, CiliarMove (v219) and Cilialyzer (v1.2.1-b3098cb), against the manual count method. We used high-speed videos of nasal ciliary brush samples from PCD RSPH4A-positive (PCD (RSPH4A)) patients and healthy controls. All three methods showed lower median CBF values for patients with PCD (RSPH4A) than in healthy controls. CiliarMove and Cilialyzer identified lower CBF in patients with PCD (RSPH4A), similarly to the manual count. Cilialyzer, CiliarMove, and manual count methods demonstrated statistical significance (p-value < 0.0001) in the difference of median CBF values between patients with PCD (RSPH4A) and healthy controls. Correlation coefficients between the manual count values against both software methods demonstrated positive linear relationships. These findings support the utility of open-source software-based analysis tools. Further studies are needed to validate these findings with other genetic variants and identify the optimal software for accurate CBF measurement in patients with PCD.
Collapse
Affiliation(s)
- Zachary J. Demetriou
- Department of Pediatrics and Basic Science, Ponce Health Sciences University, Ponce, PR 00716, USA; (Z.J.D.); (G.R.-O.); (F.M.Q.); (G.G.-D.); (M.J.R.-B.)
| | | | - Gabriel Rosario-Ortiz
- Department of Pediatrics and Basic Science, Ponce Health Sciences University, Ponce, PR 00716, USA; (Z.J.D.); (G.R.-O.); (F.M.Q.); (G.G.-D.); (M.J.R.-B.)
| | - Frances M. Quiñones
- Department of Pediatrics and Basic Science, Ponce Health Sciences University, Ponce, PR 00716, USA; (Z.J.D.); (G.R.-O.); (F.M.Q.); (G.G.-D.); (M.J.R.-B.)
| | - Gabriel Gonzalez-Diaz
- Department of Pediatrics and Basic Science, Ponce Health Sciences University, Ponce, PR 00716, USA; (Z.J.D.); (G.R.-O.); (F.M.Q.); (G.G.-D.); (M.J.R.-B.)
| | - Marcos J. Ramos-Benitez
- Department of Pediatrics and Basic Science, Ponce Health Sciences University, Ponce, PR 00716, USA; (Z.J.D.); (G.R.-O.); (F.M.Q.); (G.G.-D.); (M.J.R.-B.)
| | - Ricardo A. Mosquera
- Department of Pediatrics, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX 77030, USA;
| | - Wilfredo De Jesús-Rojas
- Department of Pediatrics and Basic Science, Ponce Health Sciences University, Ponce, PR 00716, USA; (Z.J.D.); (G.R.-O.); (F.M.Q.); (G.G.-D.); (M.J.R.-B.)
| |
Collapse
|
2
|
Abo M, Imamura K, Hosogi S, Kobayashi T, Takeda Y, Kase K, Koba H, Watanabe S, Ohkura N, Hara J, Yano S. Comparing region of interest selection and whole-field analysis for measurement of ciliary beat frequency in high-speed video analysis. Respir Investig 2024; 62:419-425. [PMID: 38489921 DOI: 10.1016/j.resinv.2024.02.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 12/05/2023] [Accepted: 02/23/2024] [Indexed: 03/17/2024]
Abstract
BACKGROUND Ciliary beat frequency (CBF) is crucial in mucociliary clearance. High-speed video analysis (HSVA) is commonly used to measure CBF but lacks standardization. We compared visual observation and computer-assisted calculation using fast Fourier transformation (FFT) in freshly collected bronchial ciliary epithelial cells and cultured cells. METHODS Bronchial epithelial cells were obtained from 12 patients who required bronchoscopic examination. Eighty-five videos of ciliary movement of freshly collected and cultured cells were recorded and used to calculate CBF using manual observation, region of interest (ROI) selection, and whole-field analysis. RESULTS CBF measured by the ROI selection method strongly correlated with that measured using manual observation, especially in freshly collected cells. However, 27.8% of the manual observation method values were doubled in the ROI selection method, probably because a round trip of cilia was calculated as two cycles and needed to be corrected to 1/2 value. Upon increasing the number of ROIs, the results of the ROI selection method came closer to that of WFA. CONCLUSIONS Computer-assisted calculation using FFT can aid in measuring CBF; however, current methods require visual confirmation. Further automated evaluation techniques are needed to establish more standardized and generalized CBF measurement methods using HSVA.
Collapse
Affiliation(s)
- Miki Abo
- Kanazawa University Health Service Center, Kakuma-machi, Kanazawa, Ishikawa, 920-1192, Japan; Department of Respiratory Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
| | - Kousuke Imamura
- Department of Electrical, Information and Communication Engineering, Kanazawa University, Kakuma-machi, Kanazawa, Ishikawa, 920-1192, Japan
| | - Shigekuni Hosogi
- Department of Clinical and Translational Physiology, Kyoto Pharmaceutical University, Kyoto, 607-8414, Japan
| | - Takafumi Kobayashi
- Division of Medical Oncology, Cancer Research Institute, Kanazawa University, Kanazawa, Ishikawa, 920-0934, Japan
| | - Yoshihiro Takeda
- Department of Respiratory Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Kazumasa Kase
- Department of Respiratory Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Hayato Koba
- Department of Respiratory Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Satoshi Watanabe
- Department of Respiratory Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Noriyuki Ohkura
- Department of Respiratory Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Johsuke Hara
- Department of Respiratory Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Seiji Yano
- Department of Respiratory Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan; Division of Medical Oncology, Cancer Research Institute, Kanazawa University, Kanazawa, Ishikawa, 920-0934, Japan; Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kanazawa, Ishikawa, 920-1192, Japan
| |
Collapse
|
3
|
Schneiter M, Tschanz SA, Escher A, Müller L, Frenz M. The Cilialyzer - A freely available open-source software for the analysis of mucociliary activity in respiratory cells. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 241:107744. [PMID: 37598471 DOI: 10.1016/j.cmpb.2023.107744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 07/12/2023] [Accepted: 08/02/2023] [Indexed: 08/22/2023]
Abstract
BACKGROUND AND OBJECTIVE Primary ciliary dyskinesia (PCD) is a rare genetic disorder causing a defective ciliary structure, which predominantly leads to an impaired mucociliary clearance and associated airway disease. As there is currently no single diagnostic gold standard test, PCD is diagnosed by a combination of several methods comprising genetic testing and the examination of the ciliary structure and function. Among the approved diagnostic methods, only high-speed video microscopy (HSVM) allows to directly observe the ciliary motion and therefore, to directly assess ciliary function. In the present work, we present our recently developed freely available open-source software - termed "Cilialyzer", which has been specifically designed to support and facilitate the analysis of the mucociliary activity in respiratory epithelial cells captured by high-speed video microscopy. METHODS In its current state, the Cilialyzer software enables clinical PCD analysts to load, preprocess and replay recorded image sequences as well as videos with a feature-rich replaying module facilitating the commonly performed qualitative visual assessment of ciliary function (including the assessment of the ciliary beat pattern). The image processing methods made accessible through an intuitive user interface allow clinical specialists to comfortably compute the ciliary beating frequency (CBF), the activity map and the "frequency correlation length" - an observable getting newly introduced. Furthermore, the Cilialyzer contains a simple-to-use particle tracking interface to determine the mucociliary transport speed. RESULTS Cilialyzer is fully written in the Python programming language and freely available under the terms of the MIT license. The proper functioning of the computational analysis methods constituting the Cilialyzer software is demonstrated by using simulated and representative sample data from clinical practice. Additionally, the software was used to analyze high-speed videos showing samples obtained from healthy controls and genetically confirmed PCD cases (DNAI1 and DNAH11 mutations) to show its clinical applicability. CONCLUSIONS Cilialyzer serves as a useful clinical tool for PCD analysts and provides new quantitative information awaiting to be clinically evaluated using cohorts of PCD. As Cilialyzer is freely available under the terms of a permissive open-source license, it serves as a ground frame for further development of computational methods aiming at the quantification and automation of the analysis of mucociliary activity captured by HSVM.
Collapse
Affiliation(s)
- Martin Schneiter
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland; Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland.
| | - Stefan A Tschanz
- Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
| | - Anaïs Escher
- Department of Paediatrics, Inselspital Bern, University Hospital, University of Bern, 3010 Bern, Switzerland; Department of BioMedical Research, University of Bern, 3008 Bern, Switzerland
| | - Loretta Müller
- Department of Paediatrics, Inselspital Bern, University Hospital, University of Bern, 3010 Bern, Switzerland; Department of BioMedical Research, University of Bern, 3008 Bern, Switzerland
| | - Martin Frenz
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland.
| |
Collapse
|
4
|
Bricmont N, Bonhiver R, Benchimol L, Louis B, Papon JF, Monseur J, Donneau AF, Moermans C, Schleich F, Calmès D, Poirrier AL, Louis R, Seghaye MC, Kempeneers C. Temporal Stability of Ciliary Beating Post Nasal Brushing, Modulated by Storage Temperature. Diagnostics (Basel) 2023; 13:2974. [PMID: 37761341 PMCID: PMC10527713 DOI: 10.3390/diagnostics13182974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 08/31/2023] [Accepted: 09/09/2023] [Indexed: 09/29/2023] Open
Abstract
Primary ciliary dyskinesia is a heterogeneous, inherited motile ciliopathy in which respiratory cilia beat abnormally, and some ultrastructural ciliary defects and specific genetic mutations have been associated with particular ciliary beating alterations. Ciliary beating can be evaluated using digital high-speed videomicroscopy (DHSV). However, normal reference values, essential to assess ciliary beating in patients referred for a PCD diagnostic, vary between centres, as minor variations in protocols might influence ciliary beating. Consequently, establishment of normal values is essential for each PCD diagnostic centre. We aimed to evaluate whether delay after sampling, and temperature for conservation of respiratory ciliated samples, might modify assessments of ciliary beating. In total, 37 healthy nasal brushing samples of respiratory ciliated epithelia were collected. Video sequences were recorded at 37 °C immediately using DHSV. Then, the samples were divided and conserved at 4 °C or at room temperature (RT). Ciliated beating edges were then recorded at 37 °C, at 3 h and at 9 h post sampling. In six samples, recordings were continued up to 72 h after sampling. Ciliary beating was assessed manually by ciliary beat frequency (CBFM) and ciliary beat pattern (CBP). A semi-automatic software was used for quantitative analysis. Both CBF and CBP evaluated manually and by a semi-automated method were stable 9 h after sampling. CBFM was higher when evaluated using samples stored at RT than at 4 °C. CBP and the semi-automated evaluation of ciliary beating were not affected by storage temperature. When establishing normal references values, ciliary beating can be evaluated at 37 °C up to 9 h after nasal brushing, but the storage temperature modifies ciliary beating and needs to be controlled.
Collapse
Affiliation(s)
- Noemie Bricmont
- Pneumology Laboratory, I3 Group, GIGA Research Center, University of Liège, 4000 Liège, Belgium; (R.B.); (C.M.); (F.S.); (R.L.); (C.K.)
- Division of Respirology, Department of Pediatrics, University Hospital Liège, 4000 Liège, Belgium
| | - Romane Bonhiver
- Pneumology Laboratory, I3 Group, GIGA Research Center, University of Liège, 4000 Liège, Belgium; (R.B.); (C.M.); (F.S.); (R.L.); (C.K.)
- Division of Respirology, Department of Pediatrics, University Hospital Liège, 4000 Liège, Belgium
| | - Lionel Benchimol
- Department of ENT, University Hospital Liège, 4000 Liège, Belgium; (L.B.); (A.-L.P.)
| | - Bruno Louis
- Institut Mondor de Recherche Biomédicale, INSERM-UPEC UMR 955, CNRS ERL7000, 94010 Créteil, France; (B.L.); (J.-F.P.)
| | - Jean-François Papon
- Institut Mondor de Recherche Biomédicale, INSERM-UPEC UMR 955, CNRS ERL7000, 94010 Créteil, France; (B.L.); (J.-F.P.)
- ENT Department, Assistance Publique-Hôpitaux de Paris (AP-HP), Université Paris-Saclay, Hôpital Bicêtre, 94270 Le Kremlin-Bicêtre, France
| | - Justine Monseur
- Biostatistics and Research Method Center-Public Health Department, University of Liège, 4000 Liège, Belgium; (J.M.); (A.-F.D.)
| | - Anne-Françoise Donneau
- Biostatistics and Research Method Center-Public Health Department, University of Liège, 4000 Liège, Belgium; (J.M.); (A.-F.D.)
| | - Catherine Moermans
- Pneumology Laboratory, I3 Group, GIGA Research Center, University of Liège, 4000 Liège, Belgium; (R.B.); (C.M.); (F.S.); (R.L.); (C.K.)
- Department of Pneumology, University Hospital Liège, 4000 Liège, Belgium;
| | - Florence Schleich
- Pneumology Laboratory, I3 Group, GIGA Research Center, University of Liège, 4000 Liège, Belgium; (R.B.); (C.M.); (F.S.); (R.L.); (C.K.)
- Department of Pneumology, University Hospital Liège, 4000 Liège, Belgium;
| | - Doriane Calmès
- Department of Pneumology, University Hospital Liège, 4000 Liège, Belgium;
| | - Anne-Lise Poirrier
- Department of ENT, University Hospital Liège, 4000 Liège, Belgium; (L.B.); (A.-L.P.)
| | - Renaud Louis
- Pneumology Laboratory, I3 Group, GIGA Research Center, University of Liège, 4000 Liège, Belgium; (R.B.); (C.M.); (F.S.); (R.L.); (C.K.)
- Department of Pneumology, University Hospital Liège, 4000 Liège, Belgium;
| | - Marie-Christine Seghaye
- Division of Cardiology, Department of Pediatrics, University Hospital Liège, University of Liège, 4000 Liège, Belgium;
| | - Céline Kempeneers
- Pneumology Laboratory, I3 Group, GIGA Research Center, University of Liège, 4000 Liège, Belgium; (R.B.); (C.M.); (F.S.); (R.L.); (C.K.)
- Division of Respirology, Department of Pediatrics, University Hospital Liège, 4000 Liège, Belgium
| |
Collapse
|
5
|
Mohammadi F, Yadegar A, Mardani M, Ayati A, Abolhassani H, Rezaei N. Organ-based clues for diagnosis of inborn errors of immunity: A practical guide for clinicians. Immun Inflamm Dis 2023; 11:e833. [PMID: 37102642 PMCID: PMC10091206 DOI: 10.1002/iid3.833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Accepted: 03/24/2023] [Indexed: 04/28/2023] Open
Abstract
Inborn errors of immunity (IEI) comprise a group of about 490 genetic disorders that lead to aberrant functioning or the development of distinct immune system components. So far, a broad spectrum of IEI-related manifestations has been noted in the literature. Due to overlapping signs and symptoms of IEI, physicians face challenges in appropriately diagnosing and managing affected individuals. The last decade has witnesses improving in the molecular diagnosis of IEI patients. As a result, it can be the mainstay of diagnostic algorithms, prognosis, and possibly therapeutic interventions in patients with IEI. Furthermore, reviewing IEI clinical complications demonstrates that the manifestations and severity of the symptoms depend on the involved gene that causes the disease and its penetrance. Although several diagnostic criteria have been used for IEI, not every patient can be explored in the same way. As a result of the failure to consider IEI diagnosis and the variety of diagnostic capabilities and laboratory facilities in different regions, undiagnosed patients are increasing. On the other hand, early diagnosis is an almost essential element in improving the quality of life in IEI patients. Since there is no appropriate guideline for IEI diagnosis in different organs, focusing on the clues in the patient's chief complaint and physical exams can help physicians narrow their differential diagnosis. This article aims to provide a practical guide for IEI diagnosis based on the involved organ. We hope to assist clinicians in keeping IEI diagnosis in mind and minimizing possible related complications due to delayed diagnosis.
Collapse
Affiliation(s)
- Fatemeh Mohammadi
- School of MedicineTehran University of Medical SciencesTehranIran
- Universal Scientific Education and Research Network (USERN)Network of Immunity in Infection, Malignancy and Autoimmunity (NIIMA)TehranIran
| | - Amirhossein Yadegar
- School of MedicineTehran University of Medical SciencesTehranIran
- Universal Scientific Education and Research Network (USERN)Network of Immunity in Infection, Malignancy and Autoimmunity (NIIMA)TehranIran
| | - Mahta Mardani
- School of MedicineTehran University of Medical SciencesTehranIran
- Universal Scientific Education and Research Network (USERN)Network of Immunity in Infection, Malignancy and Autoimmunity (NIIMA)TehranIran
| | - Aryan Ayati
- Research Center for Advanced Technologies in Cardiovascular Medicine, Tehran Heart CenterTehran University of Medical ScienceTehranIran
| | - Hassan Abolhassani
- Research Center for Immunodeficiencies, Pediatrics Center of Excellence, Children's Medical CenterTehran University of Medical SciencesTehranIran
| | - Nima Rezaei
- Universal Scientific Education and Research Network (USERN)Network of Immunity in Infection, Malignancy and Autoimmunity (NIIMA)TehranIran
- Research Center for Immunodeficiencies, Pediatrics Center of Excellence, Children's Medical CenterTehran University of Medical SciencesTehranIran
- Primary Immunodeficiency Diseases Network (PIDNet)TehranIran
- Children's Medical CenterTehranIran
| |
Collapse
|
6
|
The RSPH4A Gene in Primary Ciliary Dyskinesia. Int J Mol Sci 2023; 24:ijms24031936. [PMID: 36768259 PMCID: PMC9915723 DOI: 10.3390/ijms24031936] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 12/29/2022] [Accepted: 01/16/2023] [Indexed: 01/21/2023] Open
Abstract
The radial spoke head protein 4 homolog A (RSPH4A) gene is one of more than 50 genes that cause Primary ciliary dyskinesia (PCD), a rare genetic ciliopathy. Genetic mutations in the RSPH4A gene alter an important protein structure involved in ciliary pathogenesis. Radial spoke proteins, such as RSPH4A, have been conserved across multiple species. In humans, ciliary function deficiency caused by RSPH4A pathogenic variants results in a clinical phenotype characterized by recurrent oto-sino-pulmonary infections. More than 30 pathogenic RSPH4A genetic variants have been associated with PCD. In Puerto Rican Hispanics, a founder mutation (RSPH4A (c.921+3_921+6delAAGT (intronic)) has been described. The spectrum of the RSPH4A PCD phenotype does not include laterality defects, which results in a challenging diagnosis. PCD diagnostic tools can combine transmission electron microscopy (TEM), nasal nitric oxide (nNO), High-Speed Video microscopy Analysis (HSVA), and immunofluorescence. The purpose of this review article is to provide a comprehensive overview of current knowledge about the RSPH4A gene in PCD, ranging from basic science to human clinical phenotype.
Collapse
|
7
|
Scopulovic L, Francis D, Pandzic E, Francis R. Quantifying cilia beat frequency using high-speed video microscopy: Assessing frame rate requirements when imaging different ciliated tissues. Physiol Rep 2022; 10:e15349. [PMID: 35678028 PMCID: PMC9178357 DOI: 10.14814/phy2.15349] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 05/17/2022] [Accepted: 05/22/2022] [Indexed: 11/24/2022] Open
Abstract
Motile cilia are found in numerous locations throughout our body and play a critical role in various physiological processes. The most commonly used method to assess cilia motility is to quantify cilia beat frequency (CBF) via video microscopy. However, a large heterogeneity exists within published literature regarding the framerate used to image cilia motility for calculating CBF. The aim of this study was to determine the optimal frame rate required to image cilia motility for CBF assessment, and if the Nyquist theorem may be used to set this rate. One‐second movies of cilia were collected at >600 fps from mouse airways and ependyma at room‐temperature or 37°C. Movies were then down‐sampled to 30–300 fps. CBF was quantified for identical cilia at different framerates by either manual counting or automated MATLAB script. Airway CBF was significantly impaired in 30 fps movies, while ependymal CBF was significantly impaired in both 60 and 30 fps movies. Pairwise comparison showed that video framerate should be at least 150 fps to accurately measure CBF, with minimal improvement in CBF accuracy in movies >150 fps. The automated script was also found to be less accurate for measuring CBF in lower fps movies than manual counting, however, this difference disappeared in higher framerate movies (>150 fps). In conclusion, our data suggest the Nyquist theorem is unreliable for setting sampling rate for CBF measurement. Instead, sampling rate should be 3–4 times faster than CBF for accurate CBF assessment. Especially if CBF calculation is to be automated.
Collapse
Affiliation(s)
- Luke Scopulovic
- Cilia Research Laboratory, College of Public Health Medical and Veterinary Sciences, James Cook University, Townsville, Queensland, Australia
| | - Deanne Francis
- Cilia Research Laboratory, College of Public Health Medical and Veterinary Sciences, James Cook University, Townsville, Queensland, Australia
| | - Elvis Pandzic
- Biomedical Imaging Facility, University of New South Wales, Sydney, New South Wales, Australia
| | - Richard Francis
- Cilia Research Laboratory, College of Public Health Medical and Veterinary Sciences, James Cook University, Townsville, Queensland, Australia
| |
Collapse
|