1
|
Enslin S, Kaul V. Past, Present, and Future. Gastrointest Endosc Clin N Am 2024. [DOI: 10.1016/j.giec.2024.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
2
|
Al-Otaibi S, Rehman A, Mujahid M, Alotaibi S, Saba T. Efficient-gastro: optimized EfficientNet model for the detection of gastrointestinal disorders using transfer learning and wireless capsule endoscopy images. PeerJ Comput Sci 2024; 10:e1902. [PMID: 38660212 PMCID: PMC11041956 DOI: 10.7717/peerj-cs.1902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 01/31/2024] [Indexed: 04/26/2024]
Abstract
Gastrointestinal diseases cause around two million deaths globally. Wireless capsule endoscopy is a recent advancement in medical imaging, but manual diagnosis is challenging due to the large number of images generated. This has led to research into computer-assisted methodologies for diagnosing these images. Endoscopy produces thousands of frames for each patient, making manual examination difficult, laborious, and error-prone. An automated approach is essential to speed up the diagnosis process, reduce costs, and potentially save lives. This study proposes transfer learning-based efficient deep learning methods for detecting gastrointestinal disorders from multiple modalities, aiming to detect gastrointestinal diseases with superior accuracy and reduce the efforts and costs of medical experts. The Kvasir eight-class dataset was used for the experiment, where endoscopic images were preprocessed and enriched with augmentation techniques. An EfficientNet model was optimized via transfer learning and fine tuning, and the model was compared to the most widely used pre-trained deep learning models. The model's efficacy was tested on another independent endoscopic dataset to prove its robustness and reliability.
Collapse
Affiliation(s)
- Shaha Al-Otaibi
- Department of Information Systems, College of Computer and Information Sciences, Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Amjad Rehman
- Artificial Intelligence & Data Analytics Lab CCIS, Prince Sultan University, Riyadh, Saudi Arabia
| | - Muhammad Mujahid
- Artificial Intelligence & Data Analytics Lab CCIS, Prince Sultan University, Riyadh, Saudi Arabia
| | - Sarah Alotaibi
- Department of Computer Science, College of Computer and Information Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Tanzila Saba
- Artificial Intelligence & Data Analytics Lab CCIS, Prince Sultan University, Riyadh, Saudi Arabia
| |
Collapse
|
3
|
Zaidi SF, Shaikh A, Surani S. The Pulse of AI: Implementation of Artificial Intelligence in Healthcare and its Potential Hazards. Open Respir Med J 2024; 18:e18743064289936. [PMID: 38660683 PMCID: PMC11037519 DOI: 10.2174/0118743064289936240115105057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 12/29/2023] [Accepted: 01/09/2024] [Indexed: 04/26/2024] Open
Abstract
In this editorial, we explore the existing utilization of artificial intelligence (AI) within the healthcare industry, examining both its scope and potential harms if implemented and relied upon on a broader scale. Collaboration among corporations, government bodies, policymakers, and medical experts is essential to address potential concerns, ensuring smooth AI integration into healthcare systems.
Collapse
Affiliation(s)
| | - Asim Shaikh
- Department of Medicine, The Aga Khan University, Karachi74800, Pakistan
| | - Salim Surani
- Department of Medicine & Pharmacology, Texas A & M University, College Station, Texas77840, USA
| |
Collapse
|
4
|
Gomes RSA, de Oliveira GHP, de Moura DTH, Kotinda APST, Matsubayashi CO, Hirsch BS, Veras MDO, Ribeiro Jordão Sasso JG, Trasolini RP, Bernardo WM, de Moura EGH. Endoscopic ultrasound artificial intelligence-assisted for prediction of gastrointestinal stromal tumors diagnosis: A systematic review and meta-analysis. World J Gastrointest Endosc 2023; 15:528-539. [PMID: 37663113 PMCID: PMC10473903 DOI: 10.4253/wjge.v15.i8.528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 06/15/2023] [Accepted: 07/24/2023] [Indexed: 08/10/2023] Open
Abstract
BACKGROUND Subepithelial lesions (SELs) are gastrointestinal tumors with heterogeneous malignant potential. Endoscopic ultrasonography (EUS) is the leading method for evaluation, but without histopathological analysis, precise differentiation of SEL risk is limited. Artificial intelligence (AI) is a promising aid for the diagnosis of gastrointestinal lesions in the absence of histopathology. AIM To determine the diagnostic accuracy of AI-assisted EUS in diagnosing SELs, especially lesions originating from the muscularis propria layer. METHODS Electronic databases including PubMed, EMBASE, and Cochrane Library were searched. Patients of any sex and > 18 years, with SELs assessed by EUS AI-assisted, with previous histopathological diagnosis, and presented sufficient data values which were extracted to construct a 2 × 2 table. The reference standard was histopathology. The primary outcome was the accuracy of AI for gastrointestinal stromal tumor (GIST). Secondary outcomes were AI-assisted EUS diagnosis for GIST vs gastrointestinal leiomyoma (GIL), the diagnostic performance of experienced endoscopists for GIST, and GIST vs GIL. Pooled sensitivity, specificity, positive, and negative predictive values were calculated. The corresponding summary receiver operating characteristic curve and post-test probability were also analyzed. RESULTS Eight retrospective studies with a total of 2355 patients and 44154 images were included in this meta-analysis. The AI-assisted EUS for GIST diagnosis showed a sensitivity of 92% [95% confidence interval (CI): 0.89-0.95; P < 0.01), specificity of 80% (95%CI: 0.75-0.85; P < 0.01), and area under the curve (AUC) of 0.949. For diagnosis of GIST vs GIL by AI-assisted EUS, specificity was 90% (95%CI: 0.88-0.95; P = 0.02) and AUC of 0.966. The experienced endoscopists' values were sensitivity of 72% (95%CI: 0.67-0.76; P < 0.01), specificity of 70% (95%CI: 0.64-0.76; P < 0.01), and AUC of 0.777 for GIST. Evaluating GIST vs GIL, the experts achieved a sensitivity of 73% (95%CI: 0.65-0.80; P < 0.01) and an AUC of 0.819. CONCLUSION AI-assisted EUS has high diagnostic accuracy for fourth-layer SELs, especially for GIST, demonstrating superiority compared to experienced endoscopists' and improving their diagnostic performance in the absence of invasive procedures.
Collapse
Affiliation(s)
- Rômulo Sérgio Araújo Gomes
- Department of Gastroenterology, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo 05403-010, Brazil
| | | | - Diogo Turiani Hourneaux de Moura
- Department of Gastroenterology, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo 05403-010, Brazil
| | - Ana Paula Samy Tanaka Kotinda
- Department of Gastroenterology, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo 05403-010, Brazil
| | - Carolina Ogawa Matsubayashi
- Department of Gastroenterology, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo 05403-010, Brazil
| | - Bruno Salomão Hirsch
- Department of Gastroenterology, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo 05403-010, Brazil
| | - Matheus de Oliveira Veras
- Department of Gastroenterology, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo 05403-010, Brazil
| | | | - Roberto Paolo Trasolini
- Division of Hepatology and Endoscopy, Department of Gastroenterology, Harvard Medical School, Brigham and Women’s Hospital, Boston, MA 02115, United States
| | - Wanderley Marques Bernardo
- Department of Gastroenterology, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo 05403-010, Brazil
| | | |
Collapse
|
5
|
Sivari E, Bostanci E, Guzel MS, Acici K, Asuroglu T, Ercelebi Ayyildiz T. A New Approach for Gastrointestinal Tract Findings Detection and Classification: Deep Learning-Based Hybrid Stacking Ensemble Models. Diagnostics (Basel) 2023; 13:diagnostics13040720. [PMID: 36832205 PMCID: PMC9954881 DOI: 10.3390/diagnostics13040720] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 02/06/2023] [Accepted: 02/10/2023] [Indexed: 02/17/2023] Open
Abstract
Endoscopic procedures for diagnosing gastrointestinal tract findings depend on specialist experience and inter-observer variability. This variability can cause minor lesions to be missed and prevent early diagnosis. In this study, deep learning-based hybrid stacking ensemble modeling has been proposed for detecting and classifying gastrointestinal system findings, aiming at early diagnosis with high accuracy and sensitive measurements and saving workload to help the specialist and objectivity in endoscopic diagnosis. In the first level of the proposed bi-level stacking ensemble approach, predictions are obtained by applying 5-fold cross-validation to three new CNN models. A machine learning classifier selected at the second level is trained according to the obtained predictions, and the final classification result is reached. The performances of the stacking models were compared with the performances of the deep learning models, and McNemar's statistical test was applied to support the results. According to the experimental results, stacking ensemble models performed with a significant difference with 98.42% ACC and 98.19% MCC in the KvasirV2 dataset and 98.53% ACC and 98.39% MCC in the HyperKvasir dataset. This study is the first to offer a new learning-oriented approach that efficiently evaluates CNN features and provides objective and reliable results with statistical testing compared to state-of-the-art studies on the subject. The proposed approach improves the performance of deep learning models and outperforms the state-of-the-art studies in the literature.
Collapse
Affiliation(s)
- Esra Sivari
- Department of Computer Engineering, Cankiri Karatekin University, Cankiri 18100, Turkey
| | - Erkan Bostanci
- Department of Computer Engineering, Ankara University, Ankara 06830, Turkey
| | | | - Koray Acici
- Department of Artificial Intelligence and Data Engineering, Ankara University, Ankara 06830, Turkey
| | - Tunc Asuroglu
- Faculty of Medicine and Health Technology, Tampere University, 33720 Tampere, Finland
- Correspondence:
| | | |
Collapse
|
6
|
Artificial Intelligence-The Rising Star in the Field of Gastroenterology and Hepatology. Diagnostics (Basel) 2023; 13:diagnostics13040662. [PMID: 36832150 PMCID: PMC9955763 DOI: 10.3390/diagnostics13040662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 01/31/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023] Open
Abstract
Artificial intelligence (AI) is a term that covers a multitude of techniques that are used in a manner that tries to reproduce human intelligence. AI is helpful in various medical specialties that use imaging for diagnostic purposes, and gastroenterology is no exception. In this field, AI has several applications, such as detecting and classifying polyps, detecting the malignancy in polyps, diagnosing Helicobacter pylori infection, gastritis, inflammatory bowel disease, gastric cancer, esophageal neoplasia, and pancreatic and hepatic lesions. The aim of this mini-review is to analyze the currently available studies regarding AI in the field of gastroenterology and hepatology and to discuss its main applications as well as its main limitations.
Collapse
|
7
|
Okimoto E, Ishimura N, Adachi K, Kinoshita Y, Ishihara S, Tada T. Application of Convolutional Neural Networks for Diagnosis of Eosinophilic Esophagitis Based on Endoscopic Imaging. J Clin Med 2022; 11:jcm11092529. [PMID: 35566653 PMCID: PMC9105792 DOI: 10.3390/jcm11092529] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 04/17/2022] [Accepted: 04/29/2022] [Indexed: 02/04/2023] Open
Abstract
Subjective symptoms associated with eosinophilic esophagitis (EoE), such as dysphagia, are not specific, thus the endoscopic identification of suggestive EoE findings is quite important for facilitating endoscopic biopsy sampling. However, poor inter-observer agreement among endoscopists regarding diagnosis has become a complicated issue, especially with inexperienced practitioners. Therefore, we constructed a computer-assisted diagnosis (CAD) system using a convolutional neural network (CNN) and evaluated its performance as a diagnostic utility. A CNN-based CAD system was developed based on ResNet50 architecture. The CNN was trained using a total of 1192 characteristic endoscopic images of 108 patients histologically proven to be in an active phase of EoE (≥15 eosinophils per high power field) as well as 1192 normal esophagus images. To evaluate diagnostic accuracy, an independent test set of 756 endoscopic images from 35 patients with EoE and 96 subjects with a normal esophagus was examined with the constructed CNN. The CNN correctly diagnosed EoE in 94.7% using a diagnosis per image analysis, with an overall sensitivity of 90.8% and specificity of 96.6%. For each case, the CNN correctly diagnosed 37 of 39 EoE cases with overall sensitivity and specificity of 94.9% and 99.0%, respectively. These findings indicate the usefulness of CNN for diagnosing EoE, especially for aiding inexperienced endoscopists during medical check-up screening.
Collapse
Affiliation(s)
- Eiko Okimoto
- Department of Internal Medicine II, Shimane University Faculty of Medicine, Izumo 693-8501, Japan; (E.O.); (S.I.)
| | - Norihisa Ishimura
- Department of Internal Medicine II, Shimane University Faculty of Medicine, Izumo 693-8501, Japan; (E.O.); (S.I.)
- Correspondence: ; Tel.: +81-853-20-2190
| | - Kyoichi Adachi
- Health Center, Shimane Environment and Health Public Corporation, Matsue 690-0012, Japan;
| | - Yoshikazu Kinoshita
- Department of Medicine, Hyogo Prefectural Harima-Himeji General Medical Center, Himeji 670-8560, Japan;
| | - Shunji Ishihara
- Department of Internal Medicine II, Shimane University Faculty of Medicine, Izumo 693-8501, Japan; (E.O.); (S.I.)
| | - Tomohiro Tada
- AI Medical Service Inc., Toshima, Tokyo 170-0013, Japan;
| |
Collapse
|
8
|
Ishimura N, Okimoto E, Shibagaki K, Ishihara S. Endoscopic diagnosis and screening of Barrett's esophagus: Inconsistency of diagnostic criteria between Japan and Western countries. DEN OPEN 2022; 2:e73. [PMID: 35310704 PMCID: PMC8828243 DOI: 10.1002/deo2.73] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 10/10/2021] [Accepted: 10/16/2021] [Indexed: 11/11/2022]
Abstract
Barrett's esophagus (BE) is an endoscopically identifiable premalignant condition for esophageal adenocarcinoma (EAC). To diagnose BE precisely, careful inspection of the anatomic landmarks, including the esophagogastric junction and the squamocolumnar junction is important. The distal end of the palisade vessels and the proximal end of the gastric folds are used as the landmark of the esophagogastric junction in endoscopic diagnosis, with the latter solely used internationally, except in some Asian countries, including Japan. In addition, the diagnostic criteria adopted internationally for BE are inconsistent, particularly between Japan and Western countries. Recently updated guidelines in Western countries have included length criteria, with a 1‐cm threshold of columnar epithelium by endoscopic observation and/or histologic confirmation of the presence of specialized intestinal metaplasia. Since BE is endoscopically diagnosed at any length without histologic assessment in Japan, the reported prevalence of short‐segment BE is very high in Japan compared with that in Western countries. Although guidelines on screening exist for BE, the current strategies based on the presence of chronic gastroesophageal reflux disease with multiple risk factors may miss the opportunity for early detection of EAC. Indeed, up to 40% of patients with EAC have no history of chronic gastroesophageal reflux disease. To discuss BE on the same footing worldwide, standardization of diagnostic criteria, screening indication, and establishment of effective techniques for detecting dysplastic lesions are eagerly awaited. Japanese guidelines for BE should be revised regarding the length criteria, including the minimum length and long‐segment BE, in line with the recently updated Western guidelines.
Collapse
Affiliation(s)
- Norihisa Ishimura
- Second Department of Internal Medicine Shimane University Faculty of Medicine Shimane Japan
| | - Eiko Okimoto
- Second Department of Internal Medicine Shimane University Faculty of Medicine Shimane Japan
| | - Kotaro Shibagaki
- Division of Gastrointestinal Endoscopy Shimane University Hospital Shimane Japan
| | - Shunji Ishihara
- Second Department of Internal Medicine Shimane University Faculty of Medicine Shimane Japan
| |
Collapse
|
9
|
Special Issue “The Next Generation of Upper Gastrointestinal Endoscopy”. Diagnostics (Basel) 2022; 12:diagnostics12010152. [PMID: 35054319 PMCID: PMC8775017 DOI: 10.3390/diagnostics12010152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 12/30/2021] [Indexed: 11/17/2022] Open
|
10
|
Medical Applications of Artificial Intelligence (Legal Aspects and Future Prospects). LAWS 2021. [DOI: 10.3390/laws11010003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Background: Cutting-edge digital technologies are being actively introduced into healthcare. The recent successful efforts of artificial intelligence in diagnosing, predicting and studying diseases, as well as in surgical assisting demonstrate its high efficiency. The AI’s ability to promptly take decisions and learn independently has motivated large corporations to focus on its development and gradual introduction into everyday life. Legal aspects of medical activities are of particular importance, yet the legal regulation of AI’s performance in healthcare is still in its infancy. The state is to a considerable extent responsible for the formation of a legal regime that would meet the needs of modern society (digital society). Objective: This study aims to determine the possible modes of AI’s functioning, to identify the participants in medical-legal relations, to define the legal personality of AI and circumscribe the scope of its competencies. Of importance is the issue of determining the grounds for imposing legal liability on persons responsible for the performance of an AI system. Results: The present study identifies the prospects for a legal assessment of AI applications in medicine. The article reviews the sources of legal regulation of AI, including the unique sources of law sanctioned by the state. Particular focus is placed on medical-legal customs and medical practices. Conclusions: The presented analysis has allowed formulating the approaches to the legal regulation of AI in healthcare.
Collapse
|